Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 32
Filter
Add more filters










Publication year range
1.
J Am Soc Mass Spectrom ; 34(5): 847-856, 2023 May 03.
Article in English | MEDLINE | ID: mdl-36976861

ABSTRACT

α-Synuclein (αSyn), a 140-residue intrinsically disordered protein, comprises the primary proteinaceous component of pathology-associated Lewy body inclusions in Parkinson's disease (PD). Due to its association with PD, αSyn is studied extensively; however, the endogenous structure and physiological roles of this protein are yet to be fully understood. Here, ion mobility-mass spectrometry and native top-down electron capture dissociation fragmentation have been used to elucidate the structural properties associated with a stable, naturally occurring dimeric species of αSyn. This stable dimer appears in both wild-type (WT) αSyn and the PD-associated variant A53E. Furthermore, we integrated a novel method for generating isotopically depleted protein into our native top-down workflow. Isotope depletion increases signal-to-noise ratio and reduces the spectral complexity of fragmentation data, enabling the monoisotopic peak of low abundant fragment ions to be observed. This enables the accurate and confident assignment of fragments unique to the αSyn dimer to be assigned and structural information about this species to be inferred. Using this approach, we were able to identify fragments unique to the dimer, which demonstrates a C-terminal to C-terminal interaction between the monomer subunits. The approach in this study holds promise for further investigation into the structural properties of endogenous multimeric species of αSyn.


Subject(s)
Intrinsically Disordered Proteins , Parkinson Disease , Humans , alpha-Synuclein/chemistry , Parkinson Disease/metabolism , Mass Spectrometry , Intrinsically Disordered Proteins/metabolism
2.
Environ Sci Process Impacts ; 25(3): 351-363, 2023 Mar 22.
Article in English | MEDLINE | ID: mdl-36723022

ABSTRACT

Mercury is considered to be one of the most toxic elements to humans. Due to pollution from industry and artisanal gold mining, mercury species are present globally in waters used for agriculture, aquaculture, and drinking water. This review summarises methods reported for preserving mercury species in water samples and highlights the associated hazards and issues with each. This includes the handling of acids in an uncontrolled environment, breakage of sample containers, and the collection and transport of sample volumes in excess of 1 L, all of which pose difficulties for both in situ collection and transportation. Literature related to aqueous mercury preservation from 2000-2021 was reviewed, as well as any commonly cited and relevant references. Amongst others, solid-phase extraction techniques were explored for preservation and preconcentration of total and speciated mercury in water samples. Additionally, the potential as a safe, in situ preservation and storage method for mercury species were summarised. The review highlighted that the stability of mercury is increased when adsorbed on a solid-phase and therefore the metal and its species can be preserved without the need for hazardous reagents or materials in the field. The mercury species can then be eluted upon return to a laboratory, where sensitive analytical detection and speciation methods can be better applied. Developments in solid phase extraction as a preservation method for unstable metals such as mercury will improve the quality of representative environmental data, and further improve toxicology and environmental monitoring studies.


Subject(s)
Mercury , Water Pollutants, Chemical , Humans , Mercury/analysis , Environmental Monitoring/methods , Water Pollutants, Chemical/analysis , Water , Gold
3.
Anal Chem ; 93(12): 5046-5053, 2021 03 30.
Article in English | MEDLINE | ID: mdl-33728904

ABSTRACT

Bottom-up mass spectrometry-based protein analysis methods employing protease digestion are routinely used to identify and characterize proteins with high specificity and sensitivity. Method performance is generally measured by sequence coverage capability and the total number of characteristic peptides identified, when compared to predicted databases. Limitations to commonly used solvent-based digestion methods currently employed include long digestion times (18-24 h or more), leading to protease autolysis, which also precludes automation, decreases sensitivity, and increases both intra- and inter-day performance variability. This report describes the development and validation of a simple, 5 min tryptic denaturing organic digestion (DOD) method for use with tandem mass spectrometry in bottom-up protein identification and characterization. It has been evaluated across select protein toxins and diagnostic clinical protein targets, substantially improving digestion performance when compared to other solution-based and enzyme-immobilized methods. The method was compared to two currently used bottom-up methods, the 24 h filter-aided sample prep (FASP) and Flash Digest (1 and 4 h) methods. Single proteins used to compare the methods included the ricin light chain, ricin heavy chain, ricin holotoxin, serotype A Clostridium botulinum toxin, Staphylococcus enterotoxin B, ribonuclease A, and thyroglobulin. In tests, across the proteins investigated, the 5 min DOD digestion method resulted in sequence coverages ranging from 55 to 100%, with relatively high reproducibility and precision; results were better than or equal to FASP method results and were greatly enhanced when compared to Flash method results. Importantly, DOD method intra- and inter-day precision was much improved as compared to results for both FASP and Flash digestions. These data indicated that the DOD method, when compared to the FASP and Flash Digest methods, dramatically reduced digestion time, while maintaining or improving the ability to detect and characterize targeted proteins, and reduced analytical variability for tryptic digestion, resulting in markedly faster and more precise analyses.


Subject(s)
Proteomics , Tandem Mass Spectrometry , Digestion , Proteins , Reproducibility of Results , Trypsin
4.
Anal Chem ; 92(18): 12429-12436, 2020 09 15.
Article in English | MEDLINE | ID: mdl-32803948

ABSTRACT

The development of various ionization and fragmentation techniques has been of key importance for establishing mass spectrometry (MS) as a powerful tool for protein characterization. One example of this is matrix-assisted laser desorption/ionization (MALDI) combined with in-source decay (ISD) fragmentation that allows mapping of N- and C-terminal regions of large proteins without the need for proteolysis. Positive ion mode ISD fragments are commonly assigned in the mass region above m/z 1000, while MALDI matrix ions generally hamper the detection of smaller singly charged fragments. The ultrahigh resolving power provided by Fourier transform ion cyclotron resonance (FT-ICR) MS partially overcomes this limitation, but to further increase the detection of smaller fragments we have revisited the application of negative ion mode MALDI-ISD and found good coverage of the peptide chain termini starting from c'2 and z'2 fragment ions. For the first time, we demonstrate that the combination of negative and positive ion MALDI FT-ICR MS is a useful tool to improve the characterization of mAbs. The different specificities of the two ion modes allowed us to selectively cover the sequence of the light and heavy chains of mAbs at increased sensitivity. A comprehensive evaluation of positive and negative ion mode MALDI-ISD FT-ICR MS in the m/z range 46-13 500 showed an increased sequence coverage for three standard proteins, namely, myoglobin, SiLuLite mAb, and NIST mAb. The data obtained in the two ion modes were, in part, complementary.


Subject(s)
Antibodies, Monoclonal/analysis , Myoglobin/analysis , Animals , Horses , Protein Conformation , Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization
5.
Anal Chem ; 92(8): 5871-5881, 2020 04 21.
Article in English | MEDLINE | ID: mdl-32212639

ABSTRACT

Comprehensive determination of primary sequence and identification of post-translational modifications (PTMs) are key elements in protein structural analysis. Various mass spectrometry (MS) based fragmentation techniques are powerful approaches for mapping both the amino acid sequence and PTMs; one of these techniques is matrix-assisted laser desorption/ionization (MALDI), combined with in-source decay (ISD) fragmentation and Fourier-transform ion cyclotron resonance (FT-ICR) MS. MALDI-ISD MS protein analysis involves only minimal sample preparation and does not require spectral deconvolution. The resulting MALDI-ISD MS data is complementary to electrospray ionization-based MS/MS sequencing readouts, providing knowledge on the types of fragment ions is available. In this study, we evaluate the isotopic distributions of z' ions in protein top-down MALDI-ISD FT-ICR mass spectra and show why these distributions can deviate from theoretical profiles as a result of co-occurring and isomeric z and y-NH3 ions. Two synthetic peptides, containing either normal or deuterated alanine residues, were used to confirm the presence and unravel the identity of isomeric z and y-NH3 fragment ions ("twins"). Furthermore, two reducing MALDI matrices, namely 1,5-diaminonaphthalene and N-phenyl-p-phenylenediamine were applied that yield ISD mass spectra with different fragment ion distributions. This study demonstrates that the relative abundance of isomeric z and y-NH3 ions requires consideration for accurate and confident assignments of z' ions in MALDI-ISD FT-ICR mass spectra.


Subject(s)
Ammonia/chemistry , Insulin/analysis , Myoglobin/analysis , 2-Naphthylamine/analogs & derivatives , 2-Naphthylamine/chemistry , 2-Naphthylamine/metabolism , Ammonia/metabolism , Animals , Horses , Humans , Insulin/metabolism , Ions/chemistry , Ions/metabolism , Molecular Structure , Myoglobin/metabolism , Phenylenediamines/chemistry , Phenylenediamines/metabolism , Protein Processing, Post-Translational , Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization , Tandem Mass Spectrometry
6.
J Am Soc Mass Spectrom ; 31(3): 700-710, 2020 Mar 04.
Article in English | MEDLINE | ID: mdl-32003978

ABSTRACT

Top-down mass spectrometry (MS) is an increasingly important technique for protein characterization. However, in many biological MS experiments, the practicality of applying top-down methodologies is still limited at higher molecular mass. In large part, this is due to the detrimental effect resulting from the partitioning of the mass spectral signal into an increasing number of isotopic peaks as molecular mass increases. Reducing the isotopologue distribution of proteins via depletion of heavy stable isotopes was first reported over 20 years ago (Marshall, A. G.; Senko, M. W.; Li, W.; Li, M.; Dillon, S., Guan, S.; Logan, T. M.. Protein Molecular Mass to 1 Da by 13C, 15N Double-Depletion and FT-ICR Mass Spectrometry. J. Am. Chem. Soc. 1997, 119, 433-434.) and has been demonstrated for several small proteins. Here we extend this approach, introducing a new highly efficient method for the production of recombinant proteins depleted in 13C and 15N and demonstrating its advantages for top-down analysis of larger proteins (up to ∼50 kDa). FT-ICR MS of isotopically depleted proteins reveals dramatically reduced isotope distributions with monoisotopic signal observed up to 50 kDa. In top-down fragmentation experiments, the reduced spectral complexity alleviates fragment-ion signal overlap, the presence of monoisotopic signals allows assignment with higher mass accuracy, and the dramatic increase in signal-to-noise ratio (up to 7-fold) permits vastly reduced acquisition times. These compounding benefits allow the assignment of ∼3-fold more fragment ions than comparable analyses of proteins with natural isotopic abundances. Finally, we demonstrate greatly increased sequence coverage in time-limited top-down experiments-highlighting advantages for top-down LC-MS/MS workflows and top-down proteomics.


Subject(s)
Mass Spectrometry/methods , Proteins/chemistry , Sequence Analysis, Protein/methods , Amino Acid Sequence , Animals , Bacterial Proteins/chemistry , Carbonic Anhydrases/chemistry , Cattle , Ferritins/chemistry , Fourier Analysis , Models, Molecular , Proteomics , Rhodospirillum rubrum/chemistry , Sphingomonas/chemistry
7.
MAbs ; 12(1): 1682403, 2020.
Article in English | MEDLINE | ID: mdl-31630606

ABSTRACT

Bispecific monoclonal antibodies (BsAbs) are engineered proteins with multiple functionalities and properties. The "bi-specificity" of these complex biopharmaceuticals is a key characteristic for the development of novel and more effective therapeutic strategies. The high structural complexity of BsAbs poses a challenge to the analytical methods needed for their characterization. Modifications of the BsAb structure, resulting from enzymatic and non-enzymatic processes, further complicate the analysis. An important example of the latter type of modification is glycation, which can occur in the manufacturing process, during storage in the formulation or in vivo after application of the drug. Glycation affects the structure, function, and stability of monoclonal antibodies, and consequently, a detailed analysis of glycation levels is required. Mass spectrometry (MS) plays a key role in the structural characterization of monoclonal antibodies and top-down, middle-up and middle-down MS approaches are increasingly used for the analysis of modifications. Here, we apply a novel middle-up strategy, based on IdeS digestion and matrix-assisted laser desorption ionization (MALDI) Fourier transform ion cyclotron resonance (FT-ICR) MS, to analyze all six different BsAb subunits in a single high-resolution mass spectrum, namely two light chains, two half fragment crystallizable regions and two Fd' regions, thus avoiding upfront chromatography. This method was used to monitor glycation changes during a 168 h forced-glycation experiment. In addition, hot spot glycation sites were localized using top-down and middle-down MALDI-in-source decay FT-ICR MS, which provided complementary information compared to standard bottom-up MS.


Subject(s)
Antibodies, Bispecific/chemistry , Antineoplastic Agents, Immunological/chemistry , Bioengineering/methods , Immunoglobulin Subunits/chemistry , Angiotensins/immunology , Animals , Cyclotrons , Fourier Analysis , Glycosylation , Humans , Mice , Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization , Vascular Endothelial Growth Factor A/immunology
8.
J Am Soc Mass Spectrom ; 30(12): 2594-2607, 2019 Dec.
Article in English | MEDLINE | ID: mdl-31617086

ABSTRACT

Two-dimensional mass spectrometry (2D MS) is a data-independent tandem mass spectrometry technique in which precursor and fragment ion species can be correlated without the need for prior ion isolation. The behavior of phase in 2D Fourier transform mass spectrometry is investigated with respect to the calculation of phase-corrected absorption-mode 2D mass spectra. 2D MS datasets have a phase that is defined differently in each dimension. In both dimensions, the phase behavior of precursor and fragment ions is found to be different. The dependence of the phase for both precursor and fragment ion signals on various parameters (e.g., modulation frequency, shape of the fragmentation zone) is discussed. Experimental data confirms the theoretical calculations of the phase in each dimension. Understanding the phase relationships in a 2D mass spectrum is beneficial to the development of possible algorithms for phase correction, which may improve both the signal-to-noise ratio and the resolving power of peaks in 2D mass spectra.

9.
Chemistry ; 25(72): 16515-16518, 2019 Dec 20.
Article in English | MEDLINE | ID: mdl-31596972

ABSTRACT

A discrete acyl carrier protein (ACP) bearing a photolabile nonhydrolysable carba(dethia) malonyl pantetheine cofactor was chemoenzymatically prepared and utilised for the trapping of biosynthetic polyketide intermediates following light activation. From the in vitro assembly of the polyketides SEK4 and SEK4b, by the type II actinorhodin "minimal" polyketide synthase (PKS), a range of putative ACP-bound diketides, tetraketides, pentaketides and hexaketides were identified and characterised by FT-ICR-MS, providing direct insights on active site accessibility and substrate processing for this enzyme class.

10.
Sci Rep ; 9(1): 8, 2019 01 09.
Article in English | MEDLINE | ID: mdl-30626890

ABSTRACT

Desorption electrospray ionisation-mass spectrometry imaging (DESI-MSI) is a powerful imaging technique for the analysis of complex surfaces. However, the often highly complex nature of biological samples is particularly challenging for MSI approaches, as options to appropriately address molecular complexity are limited. Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) offers superior mass accuracy and mass resolving power, but its moderate throughput inhibits broader application. Here we demonstrate the dramatic gains in mass resolution and/or throughput of DESI-MSI on an FT-ICR MS by developing and implementing a sophisticated data acquisition and data processing pipeline. The presented pipeline integrates, for the first time, parallel ion accumulation and detection, post-processing absorption mode Fourier transform and pixel-by-pixel internal re-calibration. To achieve that, first, we developed and coupled an external high-performance data acquisition system to an FT-ICR MS instrument to record the time-domain signals (transients) in parallel with the instrument's built-in electronics. The recorded transients were then processed by the in-house developed computationally-efficient data processing and data analysis software. Importantly, the described pipeline is shown to be applicable even to extremely large, up to 1 TB, imaging datasets. Overall, this approach provides improved analytical figures of merits such as: (i) enhanced mass resolution at no cost in experimental time; and (ii) up to 4-fold higher throughput while maintaining a constant mass resolution. Using this approach, we not only demonstrate the record 1 million mass resolution for lipid imaging from brain tissue, but explicitly show such mass resolution is required to resolve the complexity of the lipidome.

11.
Rapid Commun Mass Spectrom ; 33 Suppl 3: 1-2, 2019 07.
Article in English | MEDLINE | ID: mdl-30414208
12.
Anal Chem ; 91(3): 2079-2085, 2019 02 05.
Article in English | MEDLINE | ID: mdl-30571088

ABSTRACT

The emergence of complex protein therapeutics in general and monoclonal antibodies (mAbs) in particular have stimulated analytical chemists to develop new methods and strategies for their structural characterization. Mass spectrometry plays a key role in providing information on the primary amino acid sequence, post-translational modifications, and other structure characteristics that must be monitored during the manufacturing process and subsequent quality control assessment. In this study, we present a novel method that allows structural characterization of mAbs based on MALDI in-source decay (ISD) fragmentation, coupled with Fourier transform ion cyclotron resonance (FT-ICR) MS. The method benefits from higher resolution of absorption mode FT mass spectra, compared to magnitude mode, which enables simultaneous identification of ISD fragments from both the heavy and light chains with a higher confidence in a wide mass range up to m/ z 13 500. This method was applied to two standard mAbs, namely NIST mAb and trastuzumab, in preparation for method application in an interlaboratory study on mAbs structural analysis coordinated by the Consortium for Top-Down Proteomics. Extensive sequence coverage was obtained from the middle-down analysis (IdeS- and GingisKHAN-digested mAbs) that complemented the top-down analysis of intact mAbs. In addition, MALDI FT-ICR MS of IdeS-digested mAbs allowed isotopic-level profiling of proteoforms with regard to heavy chain N-glycosylation.


Subject(s)
Antibodies, Monoclonal/analysis , Fourier Analysis , Protein Conformation , Protein Processing, Post-Translational , Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization
13.
Food Anal Methods ; 11(9): 2447-2454, 2018 Sep.
Article in English | MEDLINE | ID: mdl-30271524

ABSTRACT

Rapid food product analysis is of great interest for quality control and assurance during the production process. Conventional quality control protocols require time and labor intensive sample preparation for analysis by state-of-the-art analytical methods. To reduce overall cost and facilitate rapid qualitative assessments, food products need to be tested with minimal sample preparation. We present a novel and simple method for assessing food product compositions by mass spectrometry using a novel surface acoustic wave nebulization method. This method provides significant advantages over conventional methods requiring no pumps, capillaries, or additional chemicals to enhance ionization for mass spectrometric analysis. In addition, the surface acoustic wave nebulization - mass spectrometry method is ideal for rapid analysis and to investigate certain compounds by using the mass spectra as a type of species-specific fingerprint analysis. We present for the first time surface acoustic wave nebulization generated mass spectra of a variety of fermented food products from a small selection of vinegars, wines, and beers.

14.
J Am Soc Mass Spectrom ; 29(6): 1230, 2018 06.
Article in English | MEDLINE | ID: mdl-29687418

ABSTRACT

In the preceding article "Top Down Tandem Mass Spectrometric Analysis of a Chemically Modified Rough-Type Lipopolysaccharide Vaccine Candidate" by Oyler et al., an error in the J5 E. coli LPS chemical structure (Figs. 2 and 4) was introduced and propagated into the final revision.

15.
J Am Soc Mass Spectrom ; 29(6): 1221-1229, 2018 06.
Article in English | MEDLINE | ID: mdl-29464544

ABSTRACT

Recent advances in lipopolysaccharide (LPS) biology have led to its use in drug discovery pipelines, including vaccine and vaccine adjuvant discovery. Desirable characteristics for LPS vaccine candidates include both the ability to produce a specific antibody titer in patients and a minimal host inflammatory response directed by the innate immune system. However, in-depth chemical characterization of most LPS extracts has not been performed; hence, biological activities of these extracts are unpredictable. Additionally, the most widely adopted workflow for LPS structure elucidation includes nonspecific chemical decomposition steps before analyses, making structures inferred and not necessarily biologically relevant. In this work, several different mass spectrometry workflows that have not been previously explored were employed to show proof-of-principle for top down LPS primary structure elucidation, specifically for a rough-type mutant (J5) E. coli-derived LPS component of a vaccine candidate. First, ion mobility filtered precursor ions were subjected to collision induced dissociation (CID) to define differences in native J5 LPS v. chemically detoxified J5 LPS (dLPS). Next, ultra-high mass resolving power, accurate mass spectrometry was employed for unequivocal precursor and product ion empirical formulae generation. Finally, MS3 analyses in an ion trap instrument showed that previous knowledge about dissociation of LPS components can be used to reconstruct and sequence LPS in a top down fashion. A structural rationale is also explained for differential inflammatory dose-response curves, in vitro, when HEK-Blue hTLR4 cells were administered increasing concentrations of native J5 LPS v. dLPS, which will be useful in future drug discovery efforts. Graphical Abstract ᅟ.


Subject(s)
Escherichia coli Vaccines/chemistry , Escherichia coli/chemistry , Lipopolysaccharides/chemistry , Tandem Mass Spectrometry/methods , Cell Line , Escherichia coli/immunology , Escherichia coli Infections/immunology , Escherichia coli Infections/prevention & control , Escherichia coli Vaccines/immunology , Humans , Lipopolysaccharides/immunology
16.
Anal Chem ; 90(1): 745-751, 2018 01 02.
Article in English | MEDLINE | ID: mdl-29193956

ABSTRACT

Antibody-drug conjugates (ADCs) are an important class of therapeutic molecule currently being used to treat HER2-positive metastatic breast cancer, relapsed or refractory Hodgkin lymphoma, systemic anaplastic large cell lymphoma, relapsed or refractory B-cell precursor acute lymphoblastic leukemia, and acute myeloid leukemia. An ADC typically consists of a small molecule or peptide-based cytotoxic moiety covalently linked, via lysine or cysteine residues, to a monoclonal antibody (mAb) scaffold. Mass spectrometric (MS) characterization of these molecules affords highly accurate molecular weight (MW) and drug-to-antibody ratio (DAR) determination and is typically performed using orthogonal acceleration time-of-flight (oa-ToF) analyzers and more recently, Orbitrap instruments. Herein we describe for the first time the use of a 15 T solariX Fourier transform ion cyclotron mass spectrometer to characterize an IgG1 mAb molecule conjugated with biotin via native lysine and cysteine residues, under native-MS and solution conditions. The cysteine-biotin conjugates remained fully intact, demonstrating the ability of the FT-ICR to maintain the noncovalent interactions and efficiently transmit labile protein complexes. Native-MS was acquired and is displayed in magnitude mode using a symmetric Hann apodization function. Baseline separation is achieved on all covalent biotin additions, for each charge state, for both the lysine- and cysteine-biotin conjugates. Average DAR values obtained by native-MS for the lysine conjugate are compared to those derived by denaturing reversed phase liquid chromatography using an oa-ToF MS system (1.56 ± 0.02 versus 2.24 ± 0.02 for the 5 equivalent and 3.99 ± 0.09 versus 4.43 ± 0.01 for the 10 equivalent, respectively). Increased DAR value accuracy can be obtained for the higher biotin-load when using standard ESI conditions as opposed to nanoESI native-MS conditions.


Subject(s)
Antibodies, Monoclonal/analysis , Biotin/analysis , Immunoconjugates/analysis , Immunoglobulin G/analysis , Mass Spectrometry/methods , Antibodies, Monoclonal/chemistry , Biotin/chemistry , Cysteine/chemistry , Immunoconjugates/chemistry , Immunoglobulin G/chemistry , Lysine/chemistry
17.
J Am Soc Mass Spectrom ; 28(2): 253-262, 2017 Feb.
Article in English | MEDLINE | ID: mdl-27924495

ABSTRACT

We present a simple algorithm for robust and unsupervised peak detection by determining a noise threshold in isotopically resolved mass spectrometry data. Solving this problem will greatly reduce the subjective and time-consuming manual picking of mass spectral peaks and so will prove beneficial in many research applications. The Autopiquer approach uses autocorrelation to test for the presence of (isotopic) structure in overlapping windows across the spectrum. Within each window, a noise threshold is optimized to remove the most unstructured data, whilst keeping as much of the (isotopic) structure as possible. This algorithm has been successfully demonstrated for both peak detection and spectral compression on data from many different classes of mass spectrometer and for different sample types, and this approach should also be extendible to other types of data that contain regularly spaced discrete peaks. Graphical Abstract ᅟ.

18.
Pathog Dis ; 74(8)2016 11.
Article in English | MEDLINE | ID: mdl-27650574

ABSTRACT

The discovery of novel pathogenic mechanisms engaged during bacterial infections requires the evolution of advanced techniques. Here, we evaluate the dual polarity matrix norharmane (NRM) to improve detection of bacterial lipid A (endotoxin), from host and vector tissues infected with Francisella novicida (Fn). We evaluated NRM for improved detection and characterization of a wide range of lipids in both positive and negative polarities, including lipid A and phospholipids across a range of matrix assisted laser desorption-ionization (MALDI)-coupled applications. NRM matrix improved the limit of detection (LOD) for monophosphoryl lipid A (MPLA) down to picogram-level representing a ten-fold improvement of LOD versus 2,5-dihydroxybenzoic acid (DHB) and 100-fold improvement of LOD versus 9-aminoacridine (9-AA). Improved LOD for lipid A subsequently facilitated detection of the Fn lipid A major ion (m/z 1665) from extracts of infected mouse spleen and the temperature-modified Fn lipid A at m/z 1637 from infected D. variabilis ticks. Finally, we simultaneously mapped bacterial phospholipid signatures within an Fn infected spleen along with exclusively host-derived inositol-based phospholipid (m/z 933) demonstrating co-profiling for the host-pathogen interaction. Expanded use of NRM matrix in other infection models and endotoxin-targeting imaging experiments will improve our understanding of the lipid interactions at the host-pathogen interface.

19.
J Mass Spectrom ; 51(6): 424-9, 2016 Jun.
Article in English | MEDLINE | ID: mdl-27270865

ABSTRACT

We compared mass spectrometric (MS) performance of surface acoustic wave nebulization (SAWN) generated by a single interdigitated transducer (IDT) designed to produce a progressive wave (PW) to one with a dual IDT that can in theory generate standing waves (SW). Given that devices using dual IDTs had been shown to produce fewer large size droplets on average, we hypothesized they would improve MS performance by improving the efficiency of desolvation. Indeed, the SW-SAWN chip provided an improved limit of detection of 1 femtomole of peptide placed on chip making it 100× more sensitive than the PW design. However, as measured by high-speed image recording and phase Doppler particle analyzer measurements, there was only a 26% increase in the small diameter (1-10 µm) droplets produced from the new device, precluding a conclusion that the decrease in droplet size was solely responsible for the improvement in MS signal/noise. Given that the dual IDT design produced a more instantaneous plume than the PW design, the more likely contributor to improved MS signal/noise was concluded to be a higher ion flux entering the mass spectrometer for the dual IDT designs. Notably, the dual IDT device allowed production of much higher quality protein mass spectra up to about 20 kDa, compared with the single IDT device. Copyright © 2016 John Wiley & Sons, Ltd.

20.
Data Brief ; 6: 68-76, 2016 Mar.
Article in English | MEDLINE | ID: mdl-26793758

ABSTRACT

A reference monoclonal antibody IgG1 and a fusion IgG protein were analyzed by top- and middle-down mass spectrometry with multiple fragmentation techniques including electron transfer dissociation (ETD) and matrix-assisted laser desorption ionization in-source decay (MALDI-ISD) to investigate heterogeneity of glycosylated protein species. Specifically, glycan structure, sites, relative abundance levels, and termini structural conformation were investigated by use of Fourier transform ion cyclotron resonance (FT-ICR) or high performance liquid chromatography electrospray ionization (HPLC-ESI) linked to an Orbitrap. Incorporating a limited enzymatic digestion by immunoglobulin G-degrading enzyme Streptococcus pyogenes (IdeS) with MALDI-ISD analysis extended sequence coverage of the internal region of the proteins without pre-fractionation. The data in this article is associated with the research article published in Journal of Proteomics (Tran et al., 2015) [1].

SELECTION OF CITATIONS
SEARCH DETAIL
...