Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Korean J Radiol ; 16(6): 1353-63, 2015.
Article in English | MEDLINE | ID: mdl-26576127

ABSTRACT

OBJECTIVE: To evaluate the image characteristics of subtraction magnetic resonance venography (SMRV) from time-resolved contrast-enhanced MR angiography (TRMRA) compared with phase-contrast MR venography (PCMRV) and single-phase contrast-enhanced MR venography (CEMRV). MATERIALS AND METHODS: Twenty-one patients who underwent brain MR venography (MRV) using standard protocols (PCMRV, CEMRV, and TRMRA) were included. SMRV was made by subtracting the arterial phase data from the venous phase data in TRMRA. Co-registration and subtraction of the two volume data was done using commercially available software. Image quality and the degree of arterial contamination of the three MRVs were compared. In the three MRVs, 19 pre-defined venous structures (14 dural sinuses and 5 cerebral veins) were evaluated. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of the three MRVs were also compared. RESULTS: Single-phase contrast-enhanced MR venography showed better image quality (median score 4 in both reviewers) than did the other two MRVs (p < 0.001), whereas SMRV (median score 3 in both reviewers) and PCMRV (median score 3 in both reviewers) had similar image quality (p ≥ 0.951). SMRV (median score 0 in both reviewers) suppressed arterial signal better than did the other MRVs (median score 1 in CEMRV, median score 2 in PCMRV, both reviewers) (p < 0.001). The dural sinus score of SMRV (median and interquartile range [IQR] 48, 43-50 for reviewer 1, 47, 43-49 for reviewer 2) was significantly higher than for PCMRV (median and IQR 31, 25-34 for reviewer 1, 30, 23-32 for reviewer 2) (p < 0.01) and did not differ from that of CEMRV (median and IQR 50, 47-52 for reviewer 1, 49, 45-51 for reviewer 2) (p = 0.146 in reviewer 1 and 0.123 in reviewer 2). The SNR and CNR of SMRV (median and IQR 104.5, 83.1-121.2 and 104.1, 74.9-120.5, respectively) were between those of CEMRV (median and IQR 150.3, 111-182.6 and 148.4, 108-178.2) and PCMRV (median and IQR 59.4, 49.2-74.9 and 53.6, 43.8-69.2). CONCLUSION: Subtraction magnetic resonance venography is a promising MRV method, with acceptable image quality and good arterial suppression.


Subject(s)
Magnetic Resonance Angiography/methods , Adult , Aged , Cerebral Veins/diagnostic imaging , Cranial Sinuses/diagnostic imaging , Female , Humans , Magnetic Resonance Angiography/instrumentation , Male , Middle Aged , Radiography , Signal-To-Noise Ratio
3.
Acta Radiol ; 56(6): 673-80, 2015 Jun.
Article in English | MEDLINE | ID: mdl-24951617

ABSTRACT

BACKGROUND: Low-dose, time-resolved, contrast-enhanced, magnetic resonance angiography (TR-CEMRA) has been described previously; however, a comparative study between low dose TR-CEMRA and time-of-flight MRA (TOF-MRA) in the diagnosis of supra-aortic arterial stenosis has not yet been published. PURPOSE: To demonstrate the feasibility and effectiveness of low-dose TR-CEMRA compared with TOF-MRA, using high-resolution contrast-enhanced MRA (HR-CEMRA) as the reference standard. MATERIAL AND METHODS: This prospective study consisted of 30 consecutive patients. All patients underwent TOF-MRA of the neck and circle of Willis and supra-aortic HR-CEMRA, followed by supra-aortic low-dose TR-CEMRA. Gadoterate meglumine (Gd-DOTA, Dotarem(®), Guerbet, Roissy CdG Cedex, France) was injected at a dose of 0.1 mmol/kg for HR-CEMRA, followed by a 0.03 mmol/kg bolus for low-dose TR-CEMRA. Three readers evaluated the assessibility and image quality, and then two readers classified each stenosis into the following categories: normal (0-30%), mild stenosis (31-50%), moderate (51-70%), severe (71-99%), and occlusion. RESULTS: TR-CEMRA and HR-CEMRA showed a greater number of assessable arterial segments than TOF-MRA (P < 0.01). For TR-CEMRA, 29 cases showed within or better than the diagnostic range, whereas all 30 cases were in the diagnostic range for TOF-MRA and HR-CEMRA. For evaluation of stenosis in a total of 743 arterial segments, both TR-CEMRA and TOF-MRA results agreed with those of HR-CEMRA in 729 segments (98.1%), with excellent inter-observer agreement of TR-CEMRA; stenosis was overestimated in nine segments (1.2%) and underestimated in five segments (0.7%). For diagnosis of stenosis using 30% as the cut-off value on HR-CEMRA, the sensitivity and specificity were 88.2% and 99.3%, respectively, for the TR-CEMRA procedure, versus 94.1% and 99.6%, respectively, for TOF-MRA. CONCLUSION: Low-dose TR-CEMRA is feasible and effective in the diagnosis of supra-aortic arterial stenosis, and could be more useful option than TOF-MRA.


Subject(s)
Aortic Diseases/diagnosis , Aortography/methods , Contrast Media/administration & dosage , Magnetic Resonance Angiography/methods , Adult , Aged , Arteries , Constriction, Pathologic , Female , Humans , Magnetic Resonance Spectroscopy , Male , Middle Aged , Prospective Studies , Time Factors
4.
Neuroradiology ; 56(4): 305-14, 2014 Apr.
Article in English | MEDLINE | ID: mdl-24526141

ABSTRACT

INTRODUCTION: This study aimed to evaluate the feasibility of non-contrast-enhanced 4D magnetic resonance angiography (NCE 4D MRA) with signal targeting with alternative radiofrequency (STAR) spin labeling and variable flip angle (VFA) sampling in the assessment of dural arteriovenous fistula (DAVF) in the transverse sinus. METHODS: Nine patients underwent NCE 4D MRA for the evaluation of DAVF in the transverse sinus at 3 T. One patient was examined twice, once before and once after the interventional treatment. All patients also underwent digital subtraction angiography (DSA) and/or contrast-enhanced magnetic resonance angiography (CEMRA). For the acquisition of NCE 4D MRA, a STAR spin tagging method was used, and a VFA sampling was applied in the data readout module instead of a constant flip angle. Two readers evaluated the NCE 4D MRA data for the diagnosis of DAVF and its type with consensus. The results were compared with those from DSA and/or CEMRA. RESULTS: All patients underwent NCE 4D MRA without any difficulty. Among seven patients with patent DAVFs, all cases showed an early visualization of the transverse sinus on NCE 4D MRA. Except for one case, the type of DAVF of NCE 4D MRA was agreed with that of reference standard study. Cortical venous reflux (CVR) was demonstrated in two cases out of three patients with CVR. CONCLUSION: NCE 4D MRA with STAR tagging and VFA sampling is technically and clinically feasible and represents a promising technique for assessment of DAVF in the transverse sinus. Further technical developments should aim at improvements of spatial and temporal coverage.


Subject(s)
Arteriovenous Fistula/pathology , Cardiac-Gated Imaging Techniques/methods , Image Interpretation, Computer-Assisted/methods , Imaging, Three-Dimensional/methods , Intracranial Arteriovenous Malformations/pathology , Magnetic Resonance Angiography/methods , Transverse Sinuses/pathology , Adult , Aged , Aged, 80 and over , Algorithms , Contrast Media , Feasibility Studies , Female , Humans , Image Enhancement/methods , Male , Middle Aged , Reproducibility of Results , Sample Size , Sensitivity and Specificity , Spin Labels
5.
Neuroradiology ; 55(10): 1205-11, 2013 Oct.
Article in English | MEDLINE | ID: mdl-23868180

ABSTRACT

INTRODUCTION: Reflux venous signal on the brain and neck time-of-flight magnetic resonance angiography (TOF MRA) is thought to be related to a compressed left brachiocephalic vein. This study is aimed to assess the prevalence of venous reflux flow in internal jugular vein (IJV), sigmoid sinus/transverse sinus (SS/TS), and inferior petrosal sinus (IPS) on the brain and neck TOF MRA and its pattern. METHODS: From the radiology database, 3,475 patients (1,526 men, 1,949 women, age range 19-94, median age 62 years) with brain and neck standard 3D TOF MRA at 3 T and 1.5 T were identified. Rotational maximal intensity projection images of 3D TOF MRA were assessed for the presence of reflux flow in IJV, IPS, and SS/TS. RESULTS: Fifty-five patients (1.6%) had reflux flow, all in the left side. It was more prevalent in females (n = 43/1,949, 2.2%) than in males (n = 12/1,526, 0.8%) (p = 0.001). The mean age of patients with reflux flow (66 years old) was older than those (60 years old) without reflux flow (p = 0.001). Three patients had arteriovenous shunt in the left arm for hemodialysis. Of the remaining 52 patients, reflux was seen on IJV in 35 patients (67.3%). There were more patients with reflux flow seen on SS/TS (n = 34) than on IPS (n = 25). CONCLUSION: Venous reflux flow on TOF MRA is infrequently observed, and reflux pattern is variable. Because it is exclusively located in the left side, the reflux signal on TOF MRA could be an alarm for an undesirable candidate for a contrast injection on the left side for contrast-enhanced imaging study.


Subject(s)
Cerebral Angiography/methods , Cerebrovascular Circulation , Cranial Sinuses/physiopathology , Jugular Veins/physiopathology , Magnetic Resonance Angiography/methods , Phlebography/methods , Vascular Diseases/physiopathology , Adult , Aged , Aged, 80 and over , Blood Flow Velocity , Cranial Sinuses/pathology , Female , Humans , Jugular Veins/pathology , Male , Middle Aged , Prevalence , Republic of Korea/epidemiology , Vascular Diseases/epidemiology , Vascular Diseases/pathology , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...