Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 62
Filter
1.
Cardiol Young ; 34(4): 914-918, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37981864

ABSTRACT

BACKGROUNDS AND OBJECTIVES: The "Fast track" protocol is an early extubation strategy to reduce ventilator-associated complications and induce early recovery after open-heart surgery. This study compared clinical outcomes between operating room extubation and ICU extubation after open-heart surgery in patients with CHD. METHODS: We retrospectively reviewed 215 patients who underwent open-heart surgery for CHDs under the scheduled "Fast track" protocol between September 2016 and April 2022. The clinical endpoints were post-operative complications, including bleeding, respiratory and neurological complications, and hospital/ICU stays. RESULTS: The patients were divided into operating room extubation (group O, n = 124) and ICU extubation (group I, n=91) groups. The most frequently performed procedures were patch closures of the atrial septal (107/215, 49.8%) and ventricular septal (89/215, 41.4%) defects. There were no significant differences in major post-operative complications or ICU and hospital stay duration between the two groups; however, patients in group I showed longer mechanical ventilatory support (0.0 min vs. 59.0 min (interquartile range: 17.0-169.0), p < 0.001). Patients in Group O showed higher initial lactate levels (3.2 ± 1.7 mg/dL versus 2.5 ± 2.0 mg/dL, p = 0.007) and more frequently used additional sedatives and opioid analgesics (33.1% versus 19.8%, p = 0.031). CONCLUSIONS: Extubation in the operating room was not beneficial for patients during post-operative ICU or hospital stay. Early extubation in the ICU resulted in more stable hemodynamics in the immediate post-operative period and required less use of sedatives and analgesics.


Subject(s)
Cardiac Surgical Procedures , Operating Rooms , Humans , Retrospective Studies , Airway Extubation/methods , Hypnotics and Sedatives , Intensive Care Units , Length of Stay
2.
Med Phys ; 51(3): 1985-1996, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37722712

ABSTRACT

BACKGROUND: In proton therapy, a highly steep distal dose penumbra can be utilized for dose conformity, given the Bragg peak characteristic of protons. However, the location of the Bragg peak in patients (i.e., the beam range) is very sensitive to range uncertainty. Even a small shift of beam range can produce a significant variation of delivered dose to tumor and normal tissues, thus degrading treatment quality and threatening patient safety. This range uncertainty issue, therefore, is one of the important aspects to be managed in proton therapy. PURPOSE: For better management of range uncertainty, range verification has been widely studied, and prompt gamma imaging (PGI) is considered one of the promising methods in that effort. In this context, a PGI system named the gamma electron vertex imaging (GEVI) system was developed and recently upgraded for application to pencil-beam scanning (PBS) proton therapy. Here, we report the first experimental results using the therapeutic spot scanning proton beams. METHODS: A homogeneous slab phantom and an anthropomorphic phantom were employed. Spherical and cubic planning target volumes (PTVs) were defined. Various range shift scenarios were introduced. Prompt gamma (PG) measurement was synchronized with beam irradiation. The measured PG distributions were aggregated to improve the PG statistics. The range shift was estimated based on the relative change of the centroid in the measured PG distribution. The estimated range shifts were analyzed by range shift mapping, confidence interval (CI) estimation, and statistical hypothesis testing. RESULTS: The range shift mapping results showed an obvious measured range shift tendency following the true shift values. However, some fluctuations were found for spots that had still-low PG statistics after spot aggregation. The 99% CI distributions showed clearly distributed range shift measurement data. The overall accuracy and precision for all investigated scenarios were 0.36 and 0.20 mm, respectively. The results of one-sample t-tests confirmed that every shift scenario could be observed up to 1 mm of shift. The ANOVA results proved that the measured range shift data could be discriminated from one another, except for 16 (of 138) comparison cases having 1-2 mm shift differences. CONCLUSIONS: This study demonstrated the feasibility of the GEVI system for measurement of range shift in spot scanning proton therapy. Our experimental results showed that the proton beam can be measured up to 1 mm of range shift with high accuracy and precision. We believe that the GEVI system is one of the most promising PGI systems for in vivo range verification. Further research for application to more various cases and patient treatments is planned.


Subject(s)
Proton Therapy , Humans , Proton Therapy/methods , Electrons , Protons , Radiotherapy Planning, Computer-Assisted/methods , Diagnostic Imaging , Phantoms, Imaging , Radiotherapy Dosage
3.
Health Phys ; 125(6): 434-445, 2023 12 01.
Article in English | MEDLINE | ID: mdl-37823824

ABSTRACT

ABSTRACT: As part of the activities of the International Commission on Radiological Protection (ICRP) Task Group 103, the present study developed a new set of respiratory tract organs consisting of the extrathoracic, bronchial, bronchiolar, and alveolar-interstitial regions for newborn, 1-, 5-, 10-, and 15-y-old males and females for use in pediatric mesh-type reference computational phantoms. The developed respiratory tract organs, while preserving the original topologies of those of the pediatric voxel-type reference computational phantoms of ICRP Publication 143, have improved anatomy and detailed structure and also include µm-thick target and source regions prescribed in ICRP Publication 66. The dosimetric impact of the developed respiratory tract organs was investigated by calculating the specific absorbed fraction for internal electron exposures, which were then compared with the ICRP Task Group 96 values. The results showed that except for the alveolar-interstitial region as a source region, the pediatric mesh phantoms showed larger specific absorbed fractions than the Task Group 96 values. The maximum difference was a factor of ~3.5 for the extrathoracic-2 basal cell and surface as target and source regions, respectively. These results reflect the differences in the target masses and geometry caused by the anatomical enhancement of the pediatric mesh phantoms. For the alveolar-interstitial region as a source region, the pediatric mesh phantoms showed larger values for low energy ranges and lower values with increasing energies, owing to the differences in the size and shape of the alveolar-interstitial region.


Subject(s)
Radiometry , Respiratory System , Humans , Male , Female , Child , Infant, Newborn , Radiation Dosage , Radiometry/methods , Electrons , Phantoms, Imaging , Monte Carlo Method
4.
J Chest Surg ; 56(6): 445-448, 2023 Nov 05.
Article in English | MEDLINE | ID: mdl-37574885

ABSTRACT

A 25-year-old man returned to Seoul National University Children's Hospital with mild dyspnea on exertion. He had undergone an arterial switch operation at 1 month after birth to correct a complete transposition of the great arteries and a ventricular septal defect. When the patient was 15 years old, dilatation of the neo-aortic sinus and annulus was first identified; since then, it had gradually increased. Given the young age of the patient and the degree of aortic regurgitation (AR), which was mild to moderate, we opted to perform a valve-sparing neo-aortic root replacement with aortic valve repair. Postoperative echocardiography showed successful reductions in the sizes of the aortic sinus and annulus, with only mild AR remaining.

5.
Health Phys ; 125(2): 137-146, 2023 Aug 01.
Article in English | MEDLINE | ID: mdl-37195207

ABSTRACT

ABSTRACT: Current practice in reference internal dosimetry assumes a fixed upright standing posture is maintained throughout the dose-integration period. Recently, the mesh-type ICRP adult reference computational phantoms were transformed into different body postures (e.g., sitting, squatting) for use in occupational dose reconstruction applications. Here, for the first time, we apply this phantom series to the study of organ dose estimates following radionuclide intake. We consider the specific cases of 137 Cs and 134 Cs ingestion (accidental/occupational intake) with attention to variability in absorbed dose as a function of posture. The ICRP Publication 137 systemic biokinetic model for soluble cesium ingestion was used to compute organ-level time-integrated activity coefficients for reference adults, over a 50-y dose-integration period, for 134 Cs and 137 Cs (and its radioactive progeny 137m Ba). Mean posture time-allocations (h d -1 for standing, sitting, and lying) were taken from published survey data. In accord with modern dosimetry formalisms (e.g., MIRD, ICRP), a posture weighting factor was introduced that accounts for the fraction of time spent within each independent posture. Absorbed dose coefficients were computed using PHITS Monte Carlo simulations. ICRP 103 tissue weighting factors were applied along with the posture weighting factors to obtain committed effective dose per unit intake (Sv Bq -1 ). For 137 Cs ingestion, most organ absorbed dose coefficients were negligibly to marginally higher (< ~3%) for sitting or crouched (lying fetal/semi-fetal) postures maintained over the dose commitment period, relative to the upright standing posture. The committed effective dose coefficients were 1.3 × 10 -8 Sv Bq -1 137 Cs for standing, sitting, or crouched postures; thus, the posture-weighted committed effective dose was not significantly different than the committed effective dose for a maintained upright standing posture. For 134 Cs ingestion, most organ absorbed dose coefficients for the sitting and crouched postures were significantly larger than the standing posture, but the differences were still considered minor (< ~8% for most organs). The committed effective dose coefficients were 1.2 × 10 -8 Sv Bq -1 134 Cs for the standing posture and 1.3 × 10 -8 Sv Bq -1 134 Cs for the sitting or crouched posture. The posture-weighted committed effective dose was 1.3 × 10 -8 Sv Bq -1 134 Cs. Body posture has minor influence on organ-level absorbed dose coefficients and committed effective dose for ingestion of soluble 137 Cs or 134 Cs.


Subject(s)
Posture , Radiometry , Cesium Radioisotopes , Phantoms, Imaging , Monte Carlo Method , Radiation Dosage
6.
Health Phys ; 124(4): 316-325, 2023 04 01.
Article in English | MEDLINE | ID: mdl-36696362

ABSTRACT

ABSTRACT: In a recent study, a comprehensive library composed of 212 phantoms with different body sizes was established by deforming the adult male and female mesh-type reference computational phantoms (MRCPs) of ICRP Publication 145 and the next-generation ICRP reference phantoms over the current voxel-type reference phantoms of ICRP Publication 110. In this study, as an application of the MRCP-based phantom library, we investigated dosimetric impacts due to the different body sizes for neutron external exposures. A comprehensive dataset of organ/tissue dose coefficients (DCs) for idealized external neutron beams with four phantoms for each sex representatively selected from the phantom library were produced by performing Monte Carlo simulations using the Geant4 code. The body size-dependent DCs produced in this study were systematically analyzed, observing that the variation of the body weights overall played a more important role in organ/tissue dose calculations than the variation of the body heights. We also observed that the reference body-size DCs based on the MRCPs indeed significantly under- or overestimated the DCs produced using the phantoms, especially for those much heavier (male: 175 cm and 140 kg; female: 165 cm and 140 kg) than the reference body sizes (male: 176 cm and 73 kg; female: 163 cm and 60 kg) by up to 1.6 or 3.3 times, respectively. We believe that the use of the body size-dependent DCs, together with the reference body-size DCs, should be beneficial for more reliable organ/tissue dose estimates of individuals considering their body sizes rather than the most common conventional approach, i.e., the sole use of the reference body size DCs.


Subject(s)
Cholangiopancreatography, Magnetic Resonance , Radiometry , Humans , Adult , Male , Female , Body Size , Body Weight , Phantoms, Imaging , Neutrons , Monte Carlo Method , Radiation Dosage
7.
Phys Med Biol ; 67(18)2022 09 12.
Article in English | MEDLINE | ID: mdl-35981551

ABSTRACT

Objective.The red bone marrow (RBM) and bone endosteum (BE), which are required for effective dose calculation, are macroscopically modeled in the reference phantoms of the international commission on radiological protection (ICRP) due to their microscopic and complex histology. In the present study, the detailed bone models were developed to simplify the dose calculation process for skeletal dosimetry.Approach.The detailed bone models were developed based on the bone models developed at the University of Florida. A new method was used to update the definition of BE region by storing the BE location indices using virtual sub-voxels. The detailed bone models were then installed in the spongiosa regions of the ICRP mesh-type reference computational phantoms (MRCPs) via the parallel geometry feature of the Geant4 code.Main results.Comparing the results between the detailed-bone-installed MRCPs and the original MRCPs with the absorbed dose to spongiosa and fluence-to-dose response function (DRF)-based methods, the DRF-based method showed much smaller but still significant differences. Compared with the values given in ICRPPublications116 and 133, the differences were very large (i.e. several orders of magnitudes), due mainly to the anatomical improvement of the skeletal system in the MRCPs; that is, spongiosa and medullary cavity are fully enclosed by cortical bone in the MRCPs but not in the ICRP-110 phantoms.Significance.The detailed bone models enable the direct calculation of the absorbed doses to the RBM and BE, simplifying the dose calculation process and potentially improving the consistency and accuracy of skeletal dosimetry.


Subject(s)
Radiation Protection , Adult , Humans , Monte Carlo Method , Phantoms, Imaging , Radiation Dosage , Radiometry/methods , X-Ray Microtomography
8.
J Radiol Prot ; 42(3)2022 08 19.
Article in English | MEDLINE | ID: mdl-35921807

ABSTRACT

In line with the activities of Task Group 103 under the International Commission on Radiological Protection (ICRP), the present study was conducted to develop a new set of alimentary tract organs consisting of the oral cavity, oesophagus, stomach, small intestine, and colon for the newborn, 1 year-old, 5 year-old, 10 year-old, and 15 year-old males and females for use in the pediatric mesh-type reference computational phantoms (MRCPs). The developed alimentary tract organs of the pediatric MRCPs, while nearly preserving the original topology and shape of those of the pediatric voxel-type reference computational phantoms (VRCPs) of ICRPPublication 143, present considerable anatomical improvement and include all micrometre-scale target and source regions as prescribed in ICRPPublication 100. To investigate the dosimetric impact of the developed alimentary tract organs, organ doses and specific absorbed fractions were computed for certain external exposures to photons and electrons and internal exposures to electrons, respectively, which were then compared with the values computed using the current ICRP models (i.e. pediatric VRCPs and ICRP-100 stylised models). The results showed that for external exposures to penetrating radiations (i.e. photons >0.04 MeV), there was generally good agreement between the compared values, within a 10% difference, except for the oral mucosa. For external exposures to weakly penetrating radiations (i.e. low-energy photons and electrons), there were significant differences, up to a factor of ∼8300, owing to the geometric difference caused by the anatomical enhancement in the MRCPs. For internal exposures of electrons, there were significant differences, the maximum of which reached a factor of ∼73 000. This was attributed not only to the geometric difference but also to the target mass difference caused by the different luminal content mass and organ shape.


Subject(s)
Radiation Protection , Surgical Mesh , Child , Child, Preschool , Computer Simulation , Female , Humans , Infant , Infant, Newborn , Male , Monte Carlo Method , Phantoms, Imaging , Photons , Radiation Dosage , Radiation Protection/methods , Radiometry/methods
9.
Phys Med Biol ; 67(18)2022 09 12.
Article in English | MEDLINE | ID: mdl-35944528

ABSTRACT

Objective.CT-mesh hybrid phantoms (or 'hybrid(s)') made from integrated patient CT data and mesh-type reference computational phantoms (MRCPs) can be beneficial for patient-specific whole-body dose evaluation, but this benefit has yet to be evaluated for second cancer risk prediction. The purpose of this study is to compare the hybrid's ability to predict risk throughout the body with a patient-scaled MRCP against ground truth whole-body CTs (WBCTs).Approach.Head and neck active scanning proton treatment plans were created for and simulated on seven hybrids and the corresponding scaled MRCPs and WBCTs. Equivalent dose throughout the body was calculated and input into five second cancer risk models for both excess absolute and excess relative risk (EAR and ERR). The hybrid phantom was evaluated by comparing equivalent dose and risk predictions against the WBCT.Main results.The hybrid most frequently provides whole-body second cancer risk predictions which are closer to the ground truth when compared to a scaled MRCP alone. The performance of the hybrid relative to the scaled MRCP was consistent across ERR, EAR, and all risk models. For all in-field organs, where the hybrid shares the WBCT anatomy, the hybrid was better than or equal to the scaled MRCP for both equivalent dose and risk prediction. For out-of-field organs across all patients, the hybrid's equivalent dose prediction was superior than the scaled MRCP in 48% of all comparisons, equivalent for 34%, and inferior for 18%. For risk assessment in the same organs, the hybrid's prediction was superior than the scaled MRCP in 51.8% of all comparisons, equivalent in 28.6%, and inferior in 19.6%.Significance.Whole-body risk predictions from the CT-mesh hybrid have shown to be more accurate than those from a reference phantom alone. These hybrids could aid in risk-optimized treatment planning and individual risk assessment to minimize second cancer incidence.


Subject(s)
Neoplasms, Second Primary , Radiometry , Humans , Phantoms, Imaging , Radiometry/methods , Risk , Tomography, X-Ray Computed
10.
J Chest Surg ; 55(3): 189-196, 2022 Jun 05.
Article in English | MEDLINE | ID: mdl-35440518

ABSTRACT

Background: This study investigated the predictive value of the frailty index calculated using laboratory data and vital signs (FI-L) in patients who underwent coronary artery bypass grafting (CABG). Methods: This study included 508 patients (age 67.3±9.7 years, male 78.0%) who underwent CABG between 2018 and 2021. The FI-L, which estimates patients' frailty based on laboratory data and vital signs, was calculated as the ratio of variables outside the normal range for 32 preoperative parameters. The primary endpoints were operative and medium-term all-cause mortality. The secondary endpoints were early postoperative complications and major adverse cardiac and cerebrovascular events (MACCEs). Results: The mean FI-L was 20.9%±10.9%. The early mortality rate was 1.6% (n=8). Postoperative complications were atrial fibrillation (n=148, 29.1%), respiratory complications (n=38, 7.5%), and acute kidney injury (n=15, 3.0%). The 1- and 3-year survival rates were 96.0% and 88.7%, and the 1- and 3-year cumulative incidence rates of MACCEs were 4.87% and 8.98%. In multivariable analyses, the FI-L showed statistically significant associations with medium-term all-cause mortality (hazard ratio [HR], 1.042; 95% confidence interval [CI], 1.010-1.076), MACCEs (subdistribution HR, 1.054; 95% CI, 1.030-1.078), atrial fibrillation (odds ratio [OR], 1.02; 95% CI, 1.002-1.039), acute kidney injury (OR, 1.06; 95% CI, 1.014-1.108), and re-operation for bleeding (OR, 1.09; 95% CI, 1.032-1.152). The minimal p-value approach showed that 32% was the best cutoff for the FI-L as a predictor of all-cause mortality post-CABG. Conclusion: The FI-L was a significant prognostic factor related to all-cause mortality and postoperative complications in patients who underwent CABG.

11.
Phys Med Biol ; 67(3)2022 02 04.
Article in English | MEDLINE | ID: mdl-34969024

ABSTRACT

Objective. As cancer survivorship increases, there is growing interest in minimizing the late effects of radiation therapy such as radiogenic second cancer, which may occur anywhere in the body. Assessing the risk of late effects requires knowledge of the dose distribution throughout the whole body, including regions far from the treatment field, beyond the typical anatomical extent of clinical computed tomography (CT) scans.Approach. A hybrid phantom was developed which consists of in-field patient CT images extracted from ground truth whole-body CT scans, out-of-field mesh phantoms scaled to basic patient measurements, and a blended transition region. Four of these hybrid phantoms were created, representing male and female patients receiving proton therapy treatment in pelvic and cranial sites. To assess the performance of the hybrid approach, we simulated treatments using the hybrid phantoms, the scaled and unscaled mesh phantoms, and the ground truth whole-body CTs. We calculated absorbed dose and equivalent dose in and outside of the treatment field, with a focus on neutrons induced in the patient by proton therapy. Proton and neutron dose was calculated using a general purpose Monte Carlo code.Main results. The hybrid phantom provided equal or superior accuracy in calculated organ dose and equivalent dose values relative to those obtained using the mesh phantoms in 78% in all selected organs and calculated dose quantities. Comparatively the default mesh and scaled mesh were equal or superior to the other phantoms in 21% and 28% of cases respectively.Significance. The proposed methodology for hybrid synthesis provides a tool for whole-body organ dose estimation for individual patients without requiring CT scans of their entire body. Such a capability would be useful for personalized assessment of late effects and risk-optimization of treatment plans.


Subject(s)
Neutrons , Proton Therapy , Female , Humans , Male , Monte Carlo Method , Phantoms, Imaging , Proton Therapy/adverse effects , Radiation Dosage , Radiometry/methods
12.
J Appl Clin Med Phys ; 23(1): e13448, 2022 Jan.
Article in English | MEDLINE | ID: mdl-34633736

ABSTRACT

PURPOSE: Tetrahedral mesh (TM)-based computational human phantoms have recently been developed for evaluation of exposure dose with the merit of precisely representing human anatomy and the changing posture freely. However, conversion of recently developed TM phantoms to the Digital Imaging and Communications in Medicine (DICOM) file format, which can be utilized in the clinic, has not been attempted. The aim of this study was to develop a technique, called TET2DICOM, to convert the TM phantoms to DICOM datasets for accurate treatment planning. MATERIALS AND METHODS: The TM phantoms were sampled in voxel form to generate the DICOM computed tomography images. The DICOM-radiotherapy structure was defined based on the contour data. To evaluate TET2DICOM, the shape distortion of the TM phantoms during the conversion process was assessed, and the converted DICOM dataset was implemented in a commercial treatment planning system (TPS). RESULTS: The volume difference between the TM phantoms and the converted DICOM dataset was evaluated as less than about 0.1% in each organ. Subsequently, the converted DICOM dataset was successfully implemented in MIM (MIM Software Inc., Cleveland, USA, version 6.5.6) and RayStation (RaySearch Laboratories, Stockholm, Sweden, version 5.0). Additionally, the various possibilities of clinical application of the program were confirmed using a deformed TM phantom in various postures. CONCLUSION: In conclusion, the TM phantom, currently the most advanced computational phantom, can be implemented in a commercial TPS and this technique can enable various TM-based applications, such as evaluation of secondary cancer risk in radiotherapy.


Subject(s)
Radiotherapy Planning, Computer-Assisted , Tomography, X-Ray Computed , Humans , Phantoms, Imaging , Software , Sweden
13.
J Radiol Prot ; 41(3)2021 Aug 19.
Article in English | MEDLINE | ID: mdl-34082408

ABSTRACT

Very recently, Task Group 103 of the International Commission on Radiological Protection (ICRP) completed the development of the paediatric mesh-type reference computational phantoms (MRCPs) comprising ten phantoms (newborn, one year-old, five year-old, ten year-old, and fifteen year-old males and females). The paediatric MRCPs address the limitations of ICRPPublication 143's paediatric reference computational phantoms, which are in voxel format, stemming from the nature of the voxel geometry and the limited voxel resolutions. The paediatric MRCPs were constructed by converting the voxel-type reference phantoms to a high-quality mesh format with substantial enhancements in the detailed anatomy of the small and complex organs and tissues (e.g. bones, lymphatic nodes, and extra-thoracic region). Besides, the paediatric MRCPs were developed in consideration of the intra-organ blood contents and by modelling the micron-thick target and source regions of the skin, lens, urinary bladder, alimentary tract organs, and respiratory tract organs prescribed by the ICRP. For external idealised exposures, the paediatric MRCPs provide very similar effective dose coefficients (DCEs) to those from the ICRP-143 phantoms but significantly different values for weakly penetrating radiations (e.g. the difference of ∼20 000 times for 10 keV electron beams). This paper introduces the developed paediatric MRCPs with a brief explanation of the construction process. Then, it discusses their computational performance in Geant4, PHITS, and MCNP6 in terms of memory usage and computation speed and their impact on dose calculations by comparing their calculated values of DCEs for external exposures with those of the voxel-type reference phantoms.


Subject(s)
Radiation Protection , Surgical Mesh , Child , Child, Preschool , Female , Humans , Infant , Infant, Newborn , Male , Monte Carlo Method , Phantoms, Imaging , Radiation Dosage
14.
J Radiol Prot ; 41(2)2021 06 01.
Article in English | MEDLINE | ID: mdl-33882468

ABSTRACT

The International Commission on Radiological Protection (ICRP) recently reduced the dose limit for the eye lens for occupational exposure from 150 mSv yr-1to 20 mSv yr-1, as averaged over defined periods of five years, with no annual dose in a single year exceeding 50 mSv, emphasizing the importance of the accurate estimation of lens dose. In the present study, for more accurate lens dosimetry, detailed eye models were developed for children and adolescents (newborns and 1, 5, 10, and 15 year olds), which were then incorporated into the pediatric mesh-type reference computational phantoms (MRCPs) and used to calculate lens dose coefficients (DCs) for photon and electron exposures. Finally, the calculated values were compared with those calculated with the adult MRCPs in order to determine the age dependence of the lens DCs. For photon exposures, the lens DCs of the pediatric MRCPs showed some sizable differences from those of the adult MRCPs at very low energies (10 and 15 keV), but the differences were all less than 35%, except for the posterior-anterior irradiation geometry, for which the lens dose is not of primary concern. For electron exposures, much larger differences were found. For the anterior-posterior (AP) and isotropic irradiation geometries, the largest differences between the lens DCs of the pediatric and adult phantoms were found in the energy range of 0.6-1 MeV, where the newborn lens DCs were larger by up to a factor of ∼5 than the adult. The lens DCs of the present study, which were calculated for the radiosensitive region of the lens, also were compared with those for the entire lens in the AP irradiation geometry. Our results showed that the DCs of the entire lens were similar to those of the radiosensitive region for 0.02-2 MeV photons and >2 MeV electrons, but that for the other energy ranges, significant differences were noticeable, i.e. 10%-40% for photons and up to a factor of ∼5 for electrons.


Subject(s)
Lens, Crystalline , Radiometry , Adolescent , Adult , Child , Humans , Infant, Newborn , Monte Carlo Method , Phantoms, Imaging , Photons , Radiation Dosage
15.
J Nucl Med ; 2021 Apr 16.
Article in English | MEDLINE | ID: mdl-33863823

ABSTRACT

Despite the known influence of anatomic variability on internal dosimetry, dosimetry for 18F-FDG and other diagnostic radiopharmaceuticals is routinely derived using reference phantoms, which embody population-averaged morphometry for a given age and sex. Moreover, phantom format affects dosimetry estimates to varying extent. Here, we applied newly developed mesh format reference phantoms and a patient-dependent phantom library to assess the impact of height, weight, and body contour variation on dosimetry of 18F-FDG. We compared the mesh reference phantom dosimetry estimates with corresponding estimates from common software to identify differences related to phantom format or software implementation. Our study serves as an example of how more precise patient size-dependent dosimetry methodology could be performed. Methods: Absorbed dose coefficients were computed for the adult mesh reference phantoms and derivative patient-dependent phantom series by Monte Carlo simulation using the PHITS radiation transport code within PARaDIM software. The dose coefficients were compared with reference absorbed dose coefficients obtained from ICRP Publication 128, or generated using software including OLINDA 2.1, OLINDA 1.1, and IDAC-dose 2.1. Results: Differences in dosimetry arising from anatomical variations were shown to be significant, with detriment-weighted dose coefficients for the percentile-specific phantoms varying by up to ±40% relative to the corresponding reference phantom effective dose coefficients, irrespective of phantom format. Similar variations were seen in the individual organ absorbed dose coefficients for the percentile-specific phantoms relative to the reference phantoms. The effective dose coefficient for the mesh reference adult was 0.017 mSv/MBq, which was 5% higher than estimated by a corresponding voxel phantom, and 10% lower than estimated by the stylized phantom format. Conclusion: We observed notable variability in 18F-FDG dosimetry across morphometrically different patients, supporting the use of patient-dependent phantoms for more accurate dosimetric estimations relative to standard reference dosimetry. These data may help in optimizing imaging protocols and research studies, in particular when longer-lived isotopes are employed.

16.
Radiat Environ Biophys ; 60(2): 317-328, 2021 05.
Article in English | MEDLINE | ID: mdl-33704559

ABSTRACT

In a previous study, posture-dependent dose coefficients (DCs) for photon external exposures were calculated using the adult male and female mesh-type reference computational phantoms (MRCPs) of the International Commission on Radiological Protection (ICRP) that had been transformed into five non-standing postures (i.e. walking, sitting, bending, kneeling, and squatting). As an extension, the present study was conducted to establish another DC dataset for external exposures to neutrons by performing Monte Carlo radiation transport simulations with the adult male and female MRCPs in the five non-standing postures. The resulting dataset included the DCs for absorbed doses (i.e., organ/tissue-averaged absorbed doses) delivered to 29 individual organs/tissues, and for effective doses for neutron energies ranging from 10-9 to 104 MeV in six irradiation geometries: antero-posterior (AP), posteroanterior (PA), left-lateral (LLAT), right-lateral (RLAT), rotational (ROT), and isotropic (ISO) geometries. The comparison of DCs for the non-standing MRCPs with those of the standing MRCPs showed significant differences. In the lateral irradiation geometries, for example, the standing MRCPs overestimate the breast DCs of the squatting MRCPs by up to a factor of 4 due to the different arm positions but underestimate the gonad DCs by up to about 17 times due to the different leg positions. The impact of different postures on effective doses was generally less than that on organ doses but still significant; for example, the standing MRCPs overestimate the effective doses of the bending MRCPs only by 20% in the AP geometry at neutron energies less than 50 MeV, but underestimate those of the kneeling MRCPs by up to 40% in the lateral geometries at energies less than 0.1 MeV.


Subject(s)
Neutrons , Posture , Radiation Dosage , Adult , Computer Simulation , Female , Humans , Male , Models, Theoretical , Monte Carlo Method , Phantoms, Imaging , Radiation Exposure
17.
J Radiol Prot ; 41(4)2021 Sep 30.
Article in English | MEDLINE | ID: mdl-33647886

ABSTRACT

For use in electron paramagnetic resonance dosimetry with tooth enamel, in the present study, very detailed mesh-type tooth models composed of 198 individual tooth models (i.e. newborn: 20; 1 year: 28; 5 years: 48; 10 years: 38; 15 years: 32; and adult: 32) were developed for each sex. The developed tooth models were then implanted in the International Commission on Radiological Protection pediatric and adult mesh-type reference computational phantoms and used to calculate tooth enamel doses, by Monte Carlo simulations with Geant4, for external photon exposures in several idealized irradiation geometries. The calculated dose values were then compared to investigate the dependency of the enamel dose on the age and sex of the phantom and the sites of the teeth. The results of the present study generally show that, if the photon energy is low (i.e. <0.1 MeV), the enamel dose is significantly affected by the age and sex of the phantom and also the sites of the teeth used for dose calculation; the differences are frequently greater than a few times or even orders of magnitude. However, with a few exceptions, the enamel dose was hardly affected by these parameters for energies between 0.1 and 3 MeV. For energies >3 MeV, moderate differences were observed (i.e., up to a factor of two), due to the existence of dose build-up in the head of the phantom for high-energy photons. The calculated dose values were also compared with those of the previous studies where voxel and mathematical models were used to calculate the enamel doses. The results again show significant differences at low energies, e.g., up to ∼3500 times at 0.015 MeV, which are mainly due to the differences in the level of tooth-modeling detailedness.


Subject(s)
Radiometry , Surgical Mesh , Adult , Child , Humans , Infant, Newborn , Monte Carlo Method , Phantoms, Imaging , Radiation Dosage
18.
J Radiol Prot ; 41(2)2021 Jun 01.
Article in English | MEDLINE | ID: mdl-33401263

ABSTRACT

In 2016, the International Commission on Radiological Protection (ICRP) launched Task Group 103 (TG 103) for the explicit purpose of developing a new generation of adult and pediatric reference computational phantoms, named 'mesh-type reference computational phantoms (MRCPs)', that can overcome the limitations of voxel-type reference computational phantoms (VRCPs) of ICRPPublications 110and143due to their finite voxel resolutions and the nature of voxel geometry. After completing the development of the adult MRCPs, TG 103 has started the development of pediatric MRCPs comprising 10 phantoms (male and female versions of the reference newborn, 1-year-old, 5-year-old, 10-year-old, and 15-year-old). As part of the TG 103 project, within the present study, the skeletal systems, one of the most important and complex organ systems of the body, were developed for each phantom age and sex. The developed skeletal systems, while closely preserving the original bone topology of the pediatric VRCPs, present substantial improvements in the anatomy of complex and/or small bones. In order to investigate the dosimetric impact of the developed skeletons, the average absorbed doses and the specific absorbed fractions for radiosensitive skeletal tissues (i.e. active marrow and bone endosteum) were computed for some selected external and internal exposure cases, which were then compared with those calculated with the skeletons of pediatric VRCPs. The comparison result showed that the dose values of the pediatric MRCPs were generally similar to those of the pediatric VRCPs for highly penetrating radiations (e.g. photons >200 keV); however, for weakly penetrating radiations (e.g. photons ⩽200 keV and electrons), significant differences up to a factor of 140 were observed.


Subject(s)
Radiation Protection , Surgical Mesh , Adult , Child , Child, Preschool , Female , Humans , Infant , Infant, Newborn , Male , Monte Carlo Method , Phantoms, Imaging , Photons , Radiation Dosage , Radiometry
19.
Phys Med Biol ; 65(23): 235025, 2020 12 02.
Article in English | MEDLINE | ID: mdl-33263312

ABSTRACT

Skeletal scintigraphy is most performed in pediatric patients using the radiopharmaceutical 99mTc labelled methylene diphosphonate (99mTc-MDP). Reference biokinetic models for 99mTc-MDP indicate 50% of the administered activity is uniformly localized to the interior bone surfaces (trabecular and cortical regions), yet imaging data clearly show some preferential uptake to the epiphyseal growth plates of the long bones. To explore the dosimetric consequences of these regional activity concentrations, we have modified mesh-type computational phantoms of the International Commission on Radiological Protection (ICRP) reference pediatric series to explicitly include geometric models of the epiphyseal growth plates (2 mm in thickness) within the left/right, distal/proximal ends of the humeri, radii, ulnae, femora, tibia, and fibulae. Bone mineral activity from the ICRP Publication 128 biokinetic model for 99mTc-MDP (ICRP 2015) was then partitioned to the growth plates at values of 0.5%, 4.4%, 8.3%, 12.2%, 16.1%, and 20%. Radiation transport simulations were performed to compute 99mTc S-values and organ dose coefficients to the soft tissues and to bone site-specific regions of spongiosa. As the percentage of bone activity assigned to the growth plates was increased (from 0.5% to 20%), absorbed doses to the soft tissue organs, active bone marrow, bone endosteum (BE), as well as the detriment-weighted dose, were shown to decrease from their nominal values (no substantial growth plate activity), while epiphyseal plate self-doses increased. In the 15 year old male phantom, moving from 0.5% to 20% relative bone activity within the epiphyseal plates resulted in a 15% reduction in active marrow (AM) and BE dose, a 10% reduction in mean soft tissue and detriment-weighted dose, and a 6.3-fold increase in epiphyseal plate self-dose. In the newborn female phantom, we observed a 18% decrease in AM and BE dose, a 10% decrease in mean soft tissue dose, a 15% decrease in detriment-weighted dose, and 12.8-fold increase in epiphyseal plate self-dose. Increases (to 3 mm) and decreases (to 1 mm) in the assumed growth plate thickness of our models were shown to impact only the growth plate self-dose. Future work in differential quantification of 99mTc-MDP activity-growth plates versus other bone surfaces-is required to provide clinically realistic data on activity partitioning as a function of patient age, and perhaps skeletal site. The phantom series presented here may be used to develop more optimized age-related guidance on 99mTc-MDP administered activities to children.


Subject(s)
Bone and Bones/diagnostic imaging , Growth Plate/metabolism , Technetium Tc 99m Medronate/metabolism , Adolescent , Biological Transport , Bone and Bones/metabolism , Child , Child, Preschool , Female , Growth Plate/diagnostic imaging , Humans , Infant, Newborn , Male , Radiometry , Radionuclide Imaging , Tomography, X-Ray Computed
20.
J Radiol Prot ; 40(4): 962-979, 2020 Sep 23.
Article in English | MEDLINE | ID: mdl-32964861

ABSTRACT

As a geometrical format for computational human phantoms, tetrahedral mesh (TM) is known to have significant advantages over polygonal mesh (PM), including higher compatibility with Monte Carlo radiation transport codes, higher computation speed, and the capability of modeling heterogeneous density variation in an organ of the phantom. In the present study, a computer program named POLY2TET was developed to convert the format of computational human phantoms from PM to TM and generate a sample source code or input file, as applicable, for the converted phantom to be used in some general-purpose Monte Carlo radiation transport codes (i.e. Geant4, PHITS, and MCNP6). The developed program was then tested using four existing high-fidelity PM phantoms. The computation speed, memory requirement, and initialisation time of the generated TM phantoms were also measured and compared with those of the original PM phantoms in Geant4. From the results of our test, it was concluded that the developed program successfully converts PM phantoms into the TM format. The organ doses calculated using the generated TM phantom for the three Monte Carlo codes all produced essentially identical dose values to those for the original PM phantoms in Geant4. The comparison of computation speed showed that compared to the original PM phantoms in Geant4, the TM phantoms in the three Monte Carlo codes were much faster in transporting the particles considered in the present study, i.e. by up to ∼2600 times for electron beams simulated in PHITS. The comparison of the memory requirement showed that the TM phantoms required more memory than the original PM phantoms, but, except for MCNP6, the memory required for the TM phantoms was still less than 12 GB, which typically is available in personal computers these days. For MCNP6, the required memory was much higher, i.e. 60-70 GB.

SELECTION OF CITATIONS
SEARCH DETAIL
...