ABSTRACT
This study quantitatively analyzed the gain of the six-dimensional (6D) cone-beam CT (CBCT) correction method compared with the conventional set-up method in 60 patients who underwent radiation treatment of head and neck and brain tumors. The correction gain of CBCT was calculated for the translational and rotational motion components separately and in combination to evaluate the individual and overall effects of these motion components. Using a statistical simulation mimicking the actual set-up correction process, the effective gain of periodic CBCT correction during the entire treatment fraction was analyzed by target size and CBCT correction period under two different correction scenarios: translation alone and full 6D corrections. From the analyses performed in this study, the gain of CBCT correction was quantitatively determined for each situation, and the appropriate CBCT correction strategy was suggested based on treatment purpose and target size.
Subject(s)
Brain Neoplasms , Cone-Beam Computed Tomography , Humans , Head/diagnostic imaging , Radiotherapy Planning, Computer-Assisted/methods , Brain Neoplasms/diagnostic imaging , Brain Neoplasms/radiotherapyABSTRACT
An alternative pseudo CT generation method for magnetic resonance image (MRI)-based radiotherapy planning was investigated in the work. A pseudo CT was initially generated using the rigid image registration between the planning MRI and previously acquired diagnostic CT scan. The pseudo CT generated was then refined to have the same morphology with that of the referenced planning image scan by applying the outer body correction scheme. This method was applied to some sample of brain image data and the feasibility of the method was assessed by comparing dosimetry results with those from the current gold standard CT-based calculations. Validation showed that nearly the entire pixel doses calculated from pseudo CT were agreed well with those from actual planning CT within 2% in dosimetric and 1mm in geometric uncertainty ranges. The results demonstrated that the method suggested in the study was sufficiently accurate, and thus could be applicable to MRI-based brain radiotherapy planning.
ABSTRACT
We evaluated the changes in the dose distribution of radiation during volumetric arc radiotherapy (VMAT), to determine the right time for adaptive replanning in prostate cancer patients with progressive weight (WT) changes. Five prostate cancer patients treated with VMAT were selected for dosimetric analysis. On the original computed tomography images, nine artificial body contours were created to reflect progressive WT changes. Combined with three different photon energies (6, 10, and 15-MV), 27 comparable virtual VMAT plans were created per patient. The dosimetric analysis included evaluation of target coverage (D95%, Dmax), conformity index, homogeneity index, and organs at risk doses. The dose differences among the plans were determined using the gamma index analysis and were compared with the dosimetric analysis. Mean D95% became lower than 98% when body contour expanded by 2.0 cm or more and Dmax became higher than 107% when body contour contracted by 1.5 cm or more in 10-MV plans. This cut-off values correlated well with gamma index analysis results. Adaptive replanning should, therefore, be considered if the depth of body contour becomes 1.5 cm smaller (WT loss) or 2.0 cm larger (WT gain) in patients treated by VMAT with 10-MV photons.