Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Am J Ophthalmol ; 184: 19-27, 2017 Dec.
Article in English | MEDLINE | ID: mdl-28947074

ABSTRACT

PURPOSE: To determine what percentage of normal eyes follow the ISNT rule, and whether ISNT rule variants may be more generalizable to the normal population. DESIGN: Cross-sectional study. METHODS: Setting: Institutional setting. STUDY POPULATION: Total of 110 normal subjects. OBSERVATION PROCEDURES: Neuroretinal rim assessments from disc photographs and retinal nerve fiber layer (RNFL) thickness measurements from spectral-domain optical coherence tomography. MAIN OUTCOME MEASURES: The percentages of subjects that obeyed the ISNT rule and its variants. RESULTS: The ISNT rule is only valid for 37.0% of disc photograph rim assessments and 43.8% of RNFL measurements. Deviation of the nasal sector from the expected ISNT pattern was a major cause for the ISNT rule not being obeyed for both rim and RNFL assessments. Specifically, 10.9% of subjects had wider nasal rims than the inferior rims, 29.4% had wider nasal rims than the superior rims, 14.7% had narrower nasal rims than the temporal rims, and 42.9% had thinner nasal RNFLs compared to the temporal quadrant. Exclusion of the nasal quadrant from the ISNT rule significantly increased the validity of ISNT variant rules, with 70.9% and 76.4% of disc photographs following the IST rule and the IS rule, respectively. Similarly, for RNFL thickness, 70.9% and 71.8% of patients followed the IST and IS rule, respectively. CONCLUSIONS: The ISNT rule is only valid for about a third of disc photographs and less than half of RNFL measurements in normal patients. ISNT rule variants, such as the IST and IS rule, may be considered, as they are valid in more than 70% of patients.


Subject(s)
Optic Disk/anatomy & histology , Photography/methods , Retinal Ganglion Cells/cytology , Cross-Sectional Studies , Female , Healthy Volunteers , Humans , Male , Middle Aged , Nerve Fibers , Prospective Studies , Tomography, Optical Coherence
3.
Semin Ophthalmol ; 26(4-5): 290-4, 2011.
Article in English | MEDLINE | ID: mdl-21958177

ABSTRACT

Glaucoma drainage devices are being used with increasing frequency for patients. Sterile endophthalmitis after implantation has been reported. Unlike traditional trabeculectomy surgery, the persistence of an implant may be contributory. As glaucoma specialists consider emerging technologies in implantable glaucoma drainage devices, it is important to understand that sterile endophthalmitis may be associated with these devices.


Subject(s)
Endophthalmitis/etiology , Glaucoma Drainage Implants/adverse effects , Glaucoma/surgery , Endophthalmitis/diagnosis , Humans , Postoperative Complications
SELECTION OF CITATIONS
SEARCH DETAIL
...