Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 90
Filter
1.
Materials (Basel) ; 15(23)2022 Nov 27.
Article in English | MEDLINE | ID: mdl-36499950

ABSTRACT

In typical color-by-blue mode-based quantum dot (QD) display devices, only part of the blue excitation light is absorbed by QD emitters, thus it is accompanied by the leakage of blue light through the devices. To address this issue, we offer, for the first time, the applicability of AuAg alloy nanoparticles (NPs) as effective blue light absorbers in InP QD-based color-by-blue platforms. For this, high-quality fluorescent green and red InP QDs with a double shell scheme of ZnSe/ZnS were synthesized and embedded in a transparent polymer film. Separately, a series of Au/Ag ratio-varied AuAg NPs with tunable plasmonic absorption peaks were synthesized. Among them, AuAg NPs possessing the most appropriate absorption peak with respect to spectral overlap with blue emission are chosen for the subsequent preparation of AuAg NP polymeric films with varied NP concentrations. A stack of AuAg NP polymeric film on top of InP QD film is then placed remotely on a blue light-emitting diode, successfully resulting in systematically progressive suppression of blue light leakage with increasing AuAg NP concentration. Furthermore, the beneficial function of the AuAg NP polymeric overlayer in mitigating undesirable QD excitation upon exposure to ambient lights was further examined.

2.
Sci Adv ; 8(21): eabm6310, 2022 May 27.
Article in English | MEDLINE | ID: mdl-35613258

ABSTRACT

The mass production of precise three-dimensional (3D) nanopatterns has long been the ultimate goal of fabrication technology. While interference lithography and proximity-field nanopatterning (PnP) may provide partial solutions, their setup complexity and limited range of realizable structures, respectively, remain the main problems. Here, we tackle these challenges by applying an inverse design to the PnP process. Our inverse design platform based on the adjoint method can efficiently find optimal phase masks for diverse target lattices and motifs. We fabricate a 2D rectangular array of nanochannels, which has not been reported for conventional PnP with normally incident light, as a proof of concept. With further demonstration of material conversion, our work provides versatile platforms for nanomaterial fabrication.

3.
J Pediatr Urol ; 18(1): 90.e1-90.e8, 2022 02.
Article in English | MEDLINE | ID: mdl-34862129

ABSTRACT

INTRODUCTION: This study aimed to describe the clinical and imaging findings, including ultrasonography (US) findings, and long-term follow-up results in pediatric patients with localized cystic disease of the kidney (LCDK). MATERIAL AND METHODS: Retrospective review of pediatric patients diagnosed with LCDK based on imaging findings showing multiple localized renal cysts with intervening normal renal parenchyma from January 2002 to August 2020. Clinical presentations and US features of the affected and contralateral kidneys were reviewed and compared with computed tomography or magnetic resonance imaging findings, if available. RESULTS: A total of 18 patients (male:female = 11:7; median age, 8 years) were included. Initial clinical presentations were incidental findings (n = 5), abdominal pain (n = 5), or hematuria (n = 5). Of the seven patients (7/18, 39%) who showed multiple hyperechoic foci with ring-down artifacts within the cystic lesions on US, six patients showed focal calcification of the cysts on CT. Two patients (2/18, 11%) had milimetric cysts in the contralateral kidney. During follow-up (range, 2-122 months), there was an increase in lesion size, with ipsilateral renal growth in four patients (4/18, 22%). There was no renal function impairment at the initial presentation or during follow-up in all patients. CONCLUSIONS: LCDK can present with milimetric calcifications (39%), contralateral milimetric renal cysts (11%), and mild size increase during renal growth (22%) in children without renal function impairment. Follow-up US is recommended without surgical intervention in these typical cases.


Subject(s)
Kidney Diseases, Cystic , Kidney Neoplasms , Child , Female , Follow-Up Studies , Humans , Kidney/diagnostic imaging , Kidney/pathology , Kidney/physiology , Kidney Diseases, Cystic/diagnostic imaging , Kidney Neoplasms/pathology , Male , Retrospective Studies , Ultrasonography
4.
ACS Nano ; 15(3): 3971-3995, 2021 Mar 23.
Article in English | MEDLINE | ID: mdl-33577296

ABSTRACT

Multiscale and multimodal imaging of material structures and properties provides solid ground on which materials theory and design can flourish. Recently, KAIST announced 10 flagship research fields, which include KAIST Materials Revolution: Materials and Molecular Modeling, Imaging, Informatics and Integration (M3I3). The M3I3 initiative aims to reduce the time for the discovery, design and development of materials based on elucidating multiscale processing-structure-property relationship and materials hierarchy, which are to be quantified and understood through a combination of machine learning and scientific insights. In this review, we begin by introducing recent progress on related initiatives around the globe, such as the Materials Genome Initiative (U.S.), Materials Informatics (U.S.), the Materials Project (U.S.), the Open Quantum Materials Database (U.S.), Materials Research by Information Integration Initiative (Japan), Novel Materials Discovery (E.U.), the NOMAD repository (E.U.), Materials Scientific Data Sharing Network (China), Vom Materials Zur Innovation (Germany), and Creative Materials Discovery (Korea), and discuss the role of multiscale materials and molecular imaging combined with machine learning in realizing the vision of M3I3. Specifically, microscopies using photons, electrons, and physical probes will be revisited with a focus on the multiscale structural hierarchy, as well as structure-property relationships. Additionally, data mining from the literature combined with machine learning will be shown to be more efficient in finding the future direction of materials structures with improved properties than the classical approach. Examples of materials for applications in energy and information will be reviewed and discussed. A case study on the development of a Ni-Co-Mn cathode materials illustrates M3I3's approach to creating libraries of multiscale structure-property-processing relationships. We end with a future outlook toward recent developments in the field of M3I3.

5.
Ultrasonography ; 39(4): 367-375, 2020 Oct.
Article in English | MEDLINE | ID: mdl-32962332

ABSTRACT

PURPOSE: The purpose of this study was to identify the optimal timing for screening spinal cord ultrasonography (US) to detect filum terminale lipoma in infants. METHODS: We retrospectively reviewed infants (<12 months old) who underwent repeated spinal cord US between April 2011 and January 2019. We excluded infants if they only had one US examination, or if they had lesions other than filum terminale lipoma. Infants with filum terminale lipoma on magnetic resonance imaging were included in the lipoma group and the others in the control group. A linear mixed model was used to assess differences in the growth pattern of filum terminale thickness by age and group. The cutoff thickness on US and its diagnostic performance were assessed according to age. RESULTS: Among 442 infants with 901 US examinations, 46 were included in the lipoma group and 58 in the control group. Sixty-seven infants had unmeasurable filum terminale thickness on initial US, including 55 neonates (82.1%) before 1 month of age. The lipoma group had significantly greater filum terminale thickness than the control group (P<0.001). Thickness increased with age in the lipoma group (P=0.027). The sensitivity of US was 87.5% and the area under the receiver operating characteristic curve was 0.949 (95% confidence interval, 0.849 to 0.991) with a cutoff value of 1.1 mm in 4- to 6-month-old infants. CONCLUSION: Screening spinal cord US could effectively diagnose filum terminale lipoma in 4- to 6-month-old infants with a cutoff thickness of 1.1 mm. Spinal cord US can be used to screen young infants with intraspinal abnormalities.

6.
Opt Express ; 28(15): 22121-22134, 2020 Jul 20.
Article in English | MEDLINE | ID: mdl-32752479

ABSTRACT

In optical nanostructures used as artificial resonance-based color filters, there is unfortunate universal trade-off between spectral sharpness and angular tolerance as well as maximum extinction. We rigorously derive the maximum performance bounds of wavelength-rejection filters realized by single-layer plasmonic metasurfaces with a dominant resonance and weak near-field coupling, and propose a multi-layer approach to overcome these single-layer limits and trade-offs. We also present a realistic example that has a narrow full-width-at-half-maximum bandwidth of 24 nm with 10 dB extinction at 532 nm with good angular tolerance up to 60°. The performance of the proposed metasurface is close to the general theoretical bound.

7.
World J Gastroenterol ; 26(7): 706-716, 2020 Feb 21.
Article in English | MEDLINE | ID: mdl-32116418

ABSTRACT

BACKGROUND: Hepatic sinusoidal obstruction syndrome (SOS) is caused by damage to hepatic sinusoidal endothelial cells that results in fibrous obliteration of intrahepatic venules and necrosis of hepatocytes. Currently the diagnosis is primarily based on nonspecific clinical features and invasive liver biopsy. Therefore, noninvasive imaging methods are required for the early diagnosis and severity assessment of hepatic SOS. AIM: To determine the effectiveness of supersonic shear wave imaging (SSI) and dual energy computed tomography (DECT) for diagnosing hepatic SOS using a rabbit model. METHODS: Among nine New Zealand white rabbits (3-4 kg, male), three in control group ingested normal saline for 20 d and six in the SOS group ingested 6-thioguanine (5 mg/kg/d) for 20 d. Liver stiffness was measured using SSI on days 0, 3, 10, and 20. On the same days, liver perfusion was evaluated from virtual monochromatic images of 55 keV and iodine map using DECT. Morphologic changes in the liver were assessed using CT. Final pathology scores were compared between the two groups. Liver stiffness and perfusion parameters were compared according to the groups, days, and pathology scores. RESULTS: Final pathology scores were significantly higher in the SOS than the control group (median 22 vs 2, P = 0.024). No gross morphologic changes were seen in livers. Liver stiffness, Hounsfield Unit values, and iodine concentrations were higher in the SOS compared to the control group on days 10 and 20 (all, P ≤ 0.007). Compared to day 0, liver stiffness and perfusion parameters were higher on day 20 in the SOS group (all, P ≤ 0.001). Correlation coefficients for liver stiffness (r = 0.635), Hounsfield Unit values (r = 0.587), and iodine concentration (r = 0.611) with final pathology scores were positive without significance (all, P > 0.05). CONCLUSION: Liver stiffness and perfusion parameters were significantly increased in the livers of a rabbit SOS model. SSI and DECT might aid in early diagnosis of hepatic SOS.


Subject(s)
Elasticity Imaging Techniques/methods , Hepatic Veno-Occlusive Disease/diagnostic imaging , Liver/diagnostic imaging , Perfusion Imaging/methods , Tomography, X-Ray Computed/methods , Animals , Disease Models, Animal , Endothelial Cells/pathology , Hepatic Veins/diagnostic imaging , Hepatic Veno-Occlusive Disease/pathology , Hepatocytes/pathology , Liver/blood supply , Liver/pathology , Male , Pulsatile Flow , Rabbits , Vascular Stiffness
8.
Eur Radiol ; 30(6): 3161-3167, 2020 Jun.
Article in English | MEDLINE | ID: mdl-32048036

ABSTRACT

OBJECTIVES: To evaluate the implications of hepatic subcapsular and capsular flows using ultrasonography (US) in children after Kasai operation. METHODS: Children who underwent liver US including color Doppler US and microvascular imaging (MVI) from May 2017 to October 2017 were retrospectively included. Children who underwent the Kasai operation for biliary atresia were included in the Kasai group and children with normal liver were included in the control group. Using US results, the number of intrahepatic biliary cysts and the maximum diameter of the spleen were evaluated in the Kasai group. Liver stiffness values were included when patients in the Kasai group had transient elastography (TE) or shear wave elastography (SWE) results. Hepatic subcapsular and capsular flows on color Doppler US and MVI were compared between the two groups using the following scores: 0, no flow reaching the hepatic capsule; 1, any flow reaching the hepatic capsule; and 2, contiguous hepatic capsular flow. The logistic regression test was used to identify associations between age, intrahepatic biliary cysts, spleen size, SWV, TE results, and flow scores measured on Doppler US and MVI in the Kasai group using the odds ratio (OR) and 95% confidence interval (CI). RESULT: A total of 65 children (mean 7.6 ± 5.3 years), 44 in the Kasai group and 21 in the control group, were included. In the control group, one child had score 1 on MVI and others had score 0 on both Doppler US and MVI. Among the Kasai group, 28 children (63.6%) had score 1, while others had score 0 using Doppler US. Using MVI, 24 children (54.5%) had score 2, 18 children had score 1, and one child had score 0. In the Kasai group, increased liver stiffness on TE was the only factor significantly associated with the presence of subcapsular flow on color Doppler US (OR 1.225, 95% CI 1.020-1.470) and increased spleen size was the only factor significantly associated with increased flow scores on MVI (OR 1.397, 95% CI 1.002-2.724). CONCLUSION: Detection of hepatic subcapsular, capsular flows on US would be meaningful for children after receiving the Kasai operation. KEY POINTS: • Hepatic subcapsular or capsular flows can be useful not only for the diagnosis but also for the postoperative follow-up in patients with biliary atresia. • Increased liver stiffness and splenomegaly after the Kasai operation were associated with presence of subcapsular or capsular flow on ultrasonography. • Evaluation of hepatic subcapsular and capsular flows could be needed to assess disease progression after receiving the Kasai operation.


Subject(s)
Biliary Atresia/physiopathology , Biliary Atresia/surgery , Liver Circulation , Microcirculation , Bile Duct Diseases/complications , Bile Duct Diseases/diagnostic imaging , Biliary Atresia/complications , Biliary Tract Surgical Procedures/adverse effects , Child , Child, Preschool , Cysts/complications , Cysts/diagnostic imaging , Elasticity Imaging Techniques/methods , Female , Humans , Liver/diagnostic imaging , Male , Postoperative Complications , Retrospective Studies , Spleen/diagnostic imaging , Splenomegaly , Ultrasonography, Doppler, Color
9.
Eur Radiol ; 30(4): 1986-1996, 2020 Apr.
Article in English | MEDLINE | ID: mdl-31858205

ABSTRACT

PURPOSE: To evaluate elasticity and perfusion change associated with fibrosis in a rabbit model of unilateral ureter obstruction using shear wave elastography (SWE) and contrast-enhanced ultrasonography (CEUS). METHODS: Complete unilateral ureter obstruction by ligation was performed in the left kidney of 15 rabbits. Renal elasticity on SWE and perfusion change on CEUS at the renal cortex were measured before and after the operation. Histopathological renal fibrosis was quantified by the stained area ratio with Masson trichrome and Picrosirius red using ImageJ analysis. Renal elasticity and perfusion values were compared by the Mann-Whitney U test and Proc Mixed as a function of time. Spearman's correlation was used to analyze differences between imaging values and fibrosis. RESULTS: The duration of imaging follow-up was up to 49 days, with interval imaging performed 1-3 times. Renal elasticity values were higher in obstructed kidneys compared to contralateral kidneys (31.0 kPa vs 16.4 kPa, p < 0.001) and increased according to postoperative time (0.46 kPa/day). With respect to renal fibrosis, SWE values were positively correlated with Masson trichrome (ρ = 0.651, p < 0.001) and Picrosirius red (ρ = 0.514, p = 0.007). Among CEUS parameters, mean transit time was negatively correlated with renal fibrosis by Masson trichrome (ρ = - 0.639, p = 0.001) and Picrosirius red (ρ = - 0.625, p = 0.001). Rise time and time to peak were positively correlated with renal fibrosis. CONCLUSION: Obstructive uropathy resulted in changes to both renal elasticity and perfusion. Renal fibrosis was moderately associated with increased renal cortical stiffness and both delayed and decreased cortical perfusion. KEY POINTS: • Obstructive uropathy causes changes in elasticity and perfusion in a rabbit model. • Renal fibrosis from obstructive uropathy increases renal cortical stiffness, and both delay and decrease cortical perfusion.


Subject(s)
Fibrosis/diagnosis , Kidney Diseases/diagnosis , Kidney/diagnostic imaging , Ultrasonography/methods , Ureteral Obstruction/diagnosis , Animals , Disease Models, Animal , Elasticity , Fibrosis/etiology , Humans , Kidney/physiopathology , Kidney Diseases/etiology , Kidney Diseases/physiopathology , Rabbits , Ureteral Obstruction/complications
10.
PLoS One ; 14(12): e0226627, 2019.
Article in English | MEDLINE | ID: mdl-31852012

ABSTRACT

PURPOSE: To investigate the clinical utility of mono-exponential model diffusion weighted imaging (DWI) using two b-values compared to the bi- or stretched exponential model to differentiate biliary atresia (BA) from non-BA in pediatric liver magnetic resonance imaging (MRI). METHODS: Patients who underwent liver MRI with DWI for suspected BA from November 2017 to September 2018 were retrospectively included and divided into BA and non-BA groups. Laboratory results including γ-glutamyl transferase (γGT) were compared between the two groups using the Mann-Whitney U test and Fisher's exact test. The hepatic apparent diffusion coefficient (ADC) 10 using ten b-values and ADC 2 using two b-values were obtained from the mono-exponential model. The slow diffusion coefficient (D), fast diffusion coefficient (D*), and perfusion fraction (f) were obtained from the bi-exponential model. The distributed diffusion coefficient (DDC) and heterogeneity index (α) were measured from the stretched exponential model. Parameters were compared between the two groups using a linear mixed model and diagnostic performance was assessed using the area under the curve (AUC) analysis. RESULTS: For 12 patients in the BA and five patients in the non-BA group, the ADC 10 (median 0.985 ×10-3 mm2/s vs. 1.332 ×10-3 mm2/s, p = 0.008), ADC 2 (median 0.987 ×10-3 mm2/s vs. 1.335 ×10-3 mm2/s, p = 0.017), D* (median 33.2 ×10-3 mm2/s vs. 55.3 ×10-3 mm2/s, p = 0.021), f (median 13.4%, vs. 22.1%, p = 0.009), and DDC (median 0.889 ×10-3 mm2/s vs. 1.323 ×10-3 mm2/s, p = 0.009) values were lower and the γGT (median 368.0 IU/L vs. 93.5 IU/L, p = 0.02) and α (median 0.699 vs. 0.556, p = 0.023) values were higher in the BA group. The AUC values for γGT (AUC 0.867 95% confidence interval [CI] 0.616-0.984), ADC 10 (AUC 0.963, 95% CI 0.834-0.998), ADC 2 (AUC 0.925, 95% CI 0.781-0.987), f (AUC 0.850, 95% CI 0.686-0.949), and DDC (AUC 0.925, 95% CI 0.781-0.987) were not significantly different, except for the D* and α values. CONCLUSION: Patients with BA had lower ADC 10, ADC 2, D*, f, and DDC values and higher γGT and α values than those in the non-BA group. The diagnostic performance of ADC 2 using only two b-values showed excellent diagnostic performance and was not significantly different from that of γGT, ADC 10, f, and DDC for diagnosing BA.


Subject(s)
Biliary Atresia/diagnostic imaging , Diagnostic Techniques, Digestive System/standards , Diffusion Magnetic Resonance Imaging/methods , Liver/diagnostic imaging , Models, Theoretical , Area Under Curve , Case-Control Studies , Humans , Infant , Retrospective Studies
11.
Sci Rep ; 9(1): 19420, 2019 12 19.
Article in English | MEDLINE | ID: mdl-31857641

ABSTRACT

The purpose of this study was to develop and test the performance of a deep learning-based algorithm to detect ileocolic intussusception using abdominal radiographs of young children. For the training set, children (≤5 years old) who underwent abdominal radiograph and ultrasonography (US) for suspicion of intussusception from March 2005 to December 2017 were retrospectively included and divided into control and intussusception groups according to the US results. A YOLOv3-based algorithm was developed to recognize the rectangular area of the right abdomen and to diagnose intussusception. For the validation set, children (≤5 years old) who underwent both radiograph and US from January to August 2018 with the suspicion of intussusception were included. Diagnostic performances of an algorithm and radiologists were compared. Total 681 children including 242 children in intussusception group were included in the training set and 75 children including 25 children in intussusception group were included in the validation set. The sensitivity of the algorithm was higher compared with that of the radiologists (0.76 vs. 0.46, p = 0.013), while specificity was not different between the algorithm and the radiologists (0.96 vs. 0.92, p = 0.32). Deep learning-based algorithm can aid screening of intussusception using abdominal radiography in young children.


Subject(s)
Algorithms , Deep Learning , Ileal Diseases/diagnostic imaging , Ileal Diseases/diagnosis , Intussusception/diagnostic imaging , Intussusception/diagnosis , Radiography, Abdominal , Humans , Image Processing, Computer-Assisted , Infant , Retrospective Studies
12.
Ultrasound Med Biol ; 45(8): 2205-2212, 2019 08.
Article in English | MEDLINE | ID: mdl-31076232

ABSTRACT

We assessed the feasibility of texture analysis to differentiate Wilms tumor, clear cell sarcoma and rhabdoid tumor of the kidney in children using gray-scale ultrasonography images. Children who had pre-operative renal ultrasonography images of the three tumors from January 2002 to February 2017 were retrospectively included as the test set, and children with the same criteria from March 2017 to December 2018 were included as the validation set. From histogram and second-order statistics, features were compared between the tumors, and diagnostic performances were assessed. Among a total of 32 children (24 children with Wilms tumors, five children with clear cell sarcomas and three children with rhabdoid tumors) from the test set, features from the second-order statistics showed an area under the curve greater than 0.89 for differentiating Wilms tumor from the others. These features aided in the differentiation of tumor type in the two children with Wilms tumors in the validation set. Therefore, texture analysis from gray-scale ultrasonography images can be used to differentiate Wilms tumors from clear cell sarcomas and rhabdoid tumors in children.


Subject(s)
Kidney Neoplasms/diagnostic imaging , Rhabdoid Tumor/diagnostic imaging , Sarcoma, Clear Cell/diagnostic imaging , Ultrasonography/methods , Wilms Tumor/diagnostic imaging , Child, Preschool , Diagnosis, Differential , Feasibility Studies , Female , Humans , Infant , Kidney/diagnostic imaging , Male , Reproducibility of Results , Retrospective Studies
13.
BMC Pediatr ; 19(1): 112, 2019 04 15.
Article in English | MEDLINE | ID: mdl-30987634

ABSTRACT

BACKGROUND: Controlled attenuation parameter (CAP) is a recently introduced, non-invasive and quantitative method to evaluate hepatic steatosis demonstrated in adults, but limited in obesity and not well evaluated in children. The aim of this study was to investigate the diagnostic performance for assessing hepatic steatosis grades using CAP in children based on MR proton density fat fraction (PDFF). METHODS: Children evaluated for non-alcoholic fatty liver disease (NAFLD) who were assessed for PDFF and CAP were enrolled retrospectively. Hepatic steatosis grades 0-3 were classified according to PDFF using cutoff values of 6, 17.5, and 23.3%. Subgroup analyses were performed in non-obese and obese groups using the 95th percentile body mass index (BMI) as a cutoff and BMI30 group when BMI > 30 kg/m2. Pearson's correlations between variables were also analyzed. RESULTS: In a total of 86 children, there were 53 in the obese group including 17 of the BMI30 group. CAP demonstrated 98.7% sensitivity and 80% specificity for diagnosing grades 1-3 vs. grade 0 using a cutoff value of 241 dB/m (area under the curve = 0.941, p < 0.001). The diagnostic performance for higher steatosis grades was suboptimal. CAP correlated with abdominal wall thickness in both obese (r = 0.549, p = 0.001) and non-obese (r = 0.386, p = 0.004) groups and did not correlate with PDFF in BMI30 group. CONCLUSION: In children with NAFLD, CAP showed excellent diagnostic performance for differentiating presence and absence of hepatic steatosis using a cutoff value of 241 dB/m. However, CAP was limited in evaluating grades of steatosis, especially in children with BMI > 30 kg/m2.


Subject(s)
Adipose Tissue/diagnostic imaging , Body Mass Index , Fatty Liver/diagnosis , Liver/diagnostic imaging , Magnetic Resonance Imaging/standards , Adolescent , Child , Female , Follow-Up Studies , Humans , Male , Prognosis , ROC Curve , Retrospective Studies , Severity of Illness Index
14.
PLoS One ; 14(4): e0214647, 2019.
Article in English | MEDLINE | ID: mdl-30934017

ABSTRACT

OBJECTIVE: To investigate the feasibility of CT-based quantitative airway and air-trapping measurements and to assess their correlation with pulmonary function in children with post-infectious bronchiolitis obliterans (PIBO). MATERIALS AND METHODS: This retrospective study approved by the institutional review board included chest CT scans and pulmonary function tests (PFT) completed between January 2005 and December 2016 in children diagnosed with PIBO. The quantitative analysis of segmental and subsegmental bronchi was performed on each chest CT scan, measuring the areas or diameters of lumens, walls, or the entire airway. The air-trapping volume (ATV), the volume of lung area exhibiting lower attenuation than the mean attenuation of normal and air-trapping areas, was also measured in each lobe. Comparison analyses between CT parameters and PFT results were performed with Pearson or Spearman correlation. RESULTS: In total, 23 patients were enrolled (mean age 7.0 ± 3.3 years; range, 4-15 years). We successfully measured 89.6% of all segmental bronchi. In the airway analysis, wall area showed a negative correlation with forced expiratory volume in one second (FEV1) in the majority of the pulmonary lobes. Air-trapping analyses demonstrated that ATV was negatively correlated with FEV1 and positively correlated with reactance at 5 Hz. CONCLUSION: Quantitative airway and air-trapping measurements from chest CT are feasible and correlate with pulmonary function in pediatric PIBO patients.


Subject(s)
Bronchiolitis Obliterans/diagnosis , Bronchiolitis Obliterans/etiology , Lung/physiology , Respiratory Tract Infections/complications , Tomography, X-Ray Computed/methods , Adolescent , Bronchiolitis Obliterans/physiopathology , Child , Child, Preschool , Feasibility Studies , Female , Humans , Lung/diagnostic imaging , Male , Predictive Value of Tests , Radiography, Thoracic/methods , Respiratory Function Tests/methods , Respiratory Tract Infections/diagnosis , Respiratory Tract Infections/physiopathology , Retrospective Studies
15.
Ultrasound Med Biol ; 45(7): 1638-1643, 2019 07.
Article in English | MEDLINE | ID: mdl-31006495

ABSTRACT

To determine normal ranges for pediatric testicular volume and stiffness values (SV) on ultrasonography (US) and shear wave elastography (SWE) with respect to age and weight, testicular US scans (including SWE) of children (<10 y old) performed from February 2015 to January 2017 were retrospectively reviewed; grossly normal testes or testes with small hydroceles were included. Correlations between age weight, and testicular volume or SV were evaluated. Among a total of 52 boys (1-92 mo, median = 23.5 mo), there were positive correlations between testicular volume and age (R2 = 0.451, p < 0.001) and weight (R2 = 0.515, p < 0.001). Testicular SV was negatively correlated with age (R2 = 0.166, p = 0.051) and weight (R2 = 0.372, p = 0.049). Therefore, SV decreases while volume increases with increasing weight in testes of healthy children. Normal ranges for testicular volume and SV in children younger than 10 y are reported.


Subject(s)
Elasticity Imaging Techniques/methods , Testis/anatomy & histology , Child , Child, Preschool , Humans , Infant , Male , Organ Size , Reference Values , Retrospective Studies , Testis/diagnostic imaging
16.
World J Gastroenterol ; 25(3): 367-377, 2019 Jan 21.
Article in English | MEDLINE | ID: mdl-30686904

ABSTRACT

BACKGROUND: A recent retrospective study confirmed that hepatic stiffness and splenic stiffness measured with magnetic resonance elastography (MRE) are strongly associated with the presence of esophageal varices. In addition, strong correlations have been reported between splenic stiffness values measured with MRE and hepatic venous pressure gradients in animal models. However, most studies have been conducted on adult populations, and previous pediatric MRE studies have only demonstrated the feasibility of MRE in pediatric populations, while the actual clinical application of spleen MRE has been limited. AIM: To assess the utility of splenic stiffness measurements by MRE to predict gastroesophageal varices in children. METHODS: We retrospectively reviewed abdominal MRE images taken on a 3T system in pediatric patients. Patients who had undergone Kasai operations for biliary atresia were selected for the Kasai group, and patients with normal livers and spleens were selected for the control group. Two-dimensional spin-echo echo-planar MRE acquisition centered on the liver, with a pneumatic driver at 60 Hz and a low amplitude, was performed to obtain hepatic and splenic stiffness values. Laboratory results for aspartate aminotransferase to platelet ratio index (APRI) were evaluated within six months of MRE, and the normalized spleen size ratio was determined with the upper normal size limit. All Kasai group patients underwent gastroesophageal endoscopy during routine follow-up. The Mann-Whitney U test, Kendall's tau b correlation and diagnostic performance analysis using the area under the curve (AUC) were performed for statistical analysis. RESULTS: The median spleen MRE value was 5.5 kPa in the control group (n = 9, age 9-18 years, range 4.7-6.4 kPa) and 8.6 kPa in the Kasai group (n = 22, age 4-18 years, range 5.0-17.8 kPa). In the Kasai group, the APRI, spleen size ratio and spleen MRE values were higher in patients with portal hypertension (n = 11) than in patients without (n = 11) (all P < 0.001) and in patients with gastroesophageal varices (n = 6) than in patients without (n = 16) (all P < 0.05), even though their liver MRE values were not different. The APRI (τ = 0.477, P = 0.007), spleen size ratio (τ = 0.401, P = 0.024) and spleen MRE values (τ = 0.426, P = 0.016) also correlated with varices grades. The AUC in predicting gastroesophageal varices was 0.844 at a cut-off of 0.65 (100% sensitivity and 75% specificity) for the APRI, and 0.844 at a cut-off of 9.9 kPa (83.3% sensitivity and 81.3% specificity) for spleen MRE values. CONCLUSION: At a cut-off of 9.9 kPa, spleen MRE values predicted gastroesophageal varices as well as the APRI and spleen size ratio in biliary atresia patients after the Kasai operation. However, liver MRE values were not useful for this purpose.


Subject(s)
Biliary Atresia/complications , Echo-Planar Imaging/methods , Elasticity Imaging Techniques/methods , Esophageal and Gastric Varices/diagnosis , Liver Cirrhosis/etiology , Spleen/diagnostic imaging , Adolescent , Aspartate Aminotransferases/blood , Biliary Atresia/surgery , Case-Control Studies , Child , Child, Preschool , Esophageal and Gastric Varices/blood , Esophageal and Gastric Varices/etiology , Female , Humans , Liver/blood supply , Liver/diagnostic imaging , Liver/pathology , Liver Cirrhosis/blood , Liver Cirrhosis/pathology , Male , Organ Size , Platelet Count , Prognosis , ROC Curve , Retrospective Studies , Spleen/pathology
17.
J Clin Med ; 8(1)2019 Jan 21.
Article in English | MEDLINE | ID: mdl-30669562

ABSTRACT

While multiple studies show that simulation methods help in educating surgical trainees, few studies have focused on developing systems that help trainees to adopt the most effective body motions. This is the first study to use a Perception Neuron® system to evaluate the relationship between body motions and simulation scores. Ten medical students participated in this study. All completed two standard tasks with da Vinci Skills Simulator (dVSS) and five standard tasks with thyroidectomy training model. This was repeated. Thyroidectomy training was conducted while participants wore a perception neuron. Motion capture (MC) score that indicated how long the tasks took to complete and each participant's economy-of-motion that was used was calculated. Correlations between the three scores were assessed by Pearson's correlation analyses. The 20 trials were categorized as low, moderate, and high overall-proficiency by summing the training model, dVSS, and MC scores. The difference between the low and high overall-proficiency trials in terms of economy-of-motion of the left or right hand was assessed by two-tailed t-test. Relative to cycle 1, the training model, dVSS, and MC scores all increased significantly in cycle 2. Three scores correlated significantly with each other. Six, eight, and six trials were classified as low, moderate, and high overall-proficiency, respectively. Low- and high-scoring trials differed significantly in terms of right (dominant) hand economy-of-motion (675.2 mm and 369.4 mm, respectively) (p = 0.043). Perception Neuron® system can be applied to simulation-based training of surgical trainees. The motion analysis score is related to the traditional scoring system.

18.
Med Biol Eng Comput ; 57(3): 601-614, 2019 Mar.
Article in English | MEDLINE | ID: mdl-30280331

ABSTRACT

Although robot-assisted surgeries offer various advantages, the discontinuous surgical operation flow resulting from switching the control between the patient-side manipulators and the endoscopic robot arm can be improved to enhance the efficiency further. Therefore, in this study, a head-mounted master interface (HMI) that can be implemented to an existing surgical robot system and allows continuous surgical operation flow using the head motion is proposed. The proposed system includes an HMI, a four degrees of freedom endoscope control system, a simple three-dimensional endoscope, and a da Vinci Research Kit. Eight volunteers performed seven head movements and their data from HMI was collected to perform support vector machine (SVM) classification. Further, ten-fold cross-validation was performed to optimize its parameters. Using the ten-fold cross-validation result, the SVM classifier with the Gaussian kernel (σ = 0.85) was chosen, which had an accuracy of 92.28%. An endoscopic control algorithm was developed using the SVM classification result. A peg transfer task was conducted to check the time-related effect of HMI's usability on the system, and the paired t test result showed that the task completion time was reduced. Further, the time delay of the system was measured to be 0.72 s. Graphical abstract A head-mounted master interface (HMI), which can be implemented to an existing surgical robot system, was developed to allow simultaneous surgical operation flow. The surgeon's head motion is detected through the proposed HMI and classified using a support vector machine to manipulate the endoscopic robotic arm. A classification accuracy of 92.28% was achieved.


Subject(s)
Endoscopy/instrumentation , Laparoscopy/methods , Robotic Surgical Procedures/instrumentation , Robotic Surgical Procedures/methods , Surgeons , Endoscopy/methods , Equipment Design , Head , Humans , Laparoscopy/instrumentation , Minimally Invasive Surgical Procedures/instrumentation , Motion , Reproducibility of Results , Time Factors , Vision, Ocular
19.
Opt Express ; 26(21): 27403-27417, 2018 Oct 15.
Article in English | MEDLINE | ID: mdl-30469809

ABSTRACT

The mode orthogonality fundamentally influences the scattering spectra of multi-resonance systems, such as plasmonic color filters. We show that planar arrays of silver nanostructures with dual localized surface plasmon resonances and the right mode orthogonality can function as transmissive RGB color filters with peak transmittances higher than 70%, and color gamut areas larger than 90% of the sRGB space. These are the brightest and most saturated of all designs proposed thus far. We present the Pareto frontier from designs with more than 80% peak transmittance, to designs that achieve a color gamut larger than 120% of the sRGB space.

20.
World J Gastroenterol ; 24(27): 3013-3020, 2018 Jul 21.
Article in English | MEDLINE | ID: mdl-30038468

ABSTRACT

AIM: To evaluate the correlation between intravoxel incoherent motion (IVIM) diffusion-weighted imaging (DWI) parameters and the degree of hepatic steatosis and fibrosis in children. METHODS: This retrospective study was approved by the institutional review board. The children (≤ 18 years) who underwent liver IVIM DWI with 8 b-values under the suspicion of hepatic steatosis or fibrosis from February 2013 to November 2016 were included. Subjects were divided into normal, fatty liver (FAT), and fibrotic liver (FIB) groups. The slow diffusion coefficient (D), fast diffusion coefficient (D*), perfusion fraction (f), and apparent diffusion coefficient (ADC) were measured. MR proton density fat fraction (PDFF), MR elastography (MRE), and IVIM values were compared. RESULTS: A total of 123 children (median age of 12 years old, range: 6-18 years) were included, with 8 in the normal group, 93 in the FAT group, and 22 in the FIB group. The D* values were lower in the FIB group compared with those of the normal (P = 0.015) and FAT (P = 0.003) groups. The f values were lower in the FIB group compared with the FAT group (P = 0.001). In multivariate analyses, PDFF value was positively correlated with f value (ß = 3.194, P < 0.001), and MRE value was negatively correlated with D* value (ß = -7.031, P = 0.032). The D and ADC values were not influenced by PDFF or MRE value. CONCLUSION: In liver IVIM DWI with multiple b-values in children, there was a positive correlation between hepatic fat and blood volume, and a negative correlation between hepatic stiffness and endovascular blood flow velocity, while diffusion-related parameters were not affected.


Subject(s)
Diffusion Magnetic Resonance Imaging/methods , Elasticity Imaging Techniques/methods , Fatty Liver/diagnostic imaging , Liver Cirrhosis/diagnostic imaging , Adolescent , Child , Feasibility Studies , Female , Humans , Image Interpretation, Computer-Assisted/methods , Liver/diagnostic imaging , Liver/pathology , Male , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...