Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Pancreas ; 43(1): 22-7, 2014 Jan.
Article in English | MEDLINE | ID: mdl-24326364

ABSTRACT

OBJECTIVES: We evaluated whether pancreatic main duct fluid can provide protein biomarkers with prognostic value. METHODS: Mass spectrometry proteomics was applied to as little as 20µL of fluid collected at the time of tumor surgical resection. Biomarker proteins identified for 27 patients were correlated with clinical outcomes. RESULTS: Thirteen patients had pancreatic ductal adenocarcinomas, 4 had intraductal papillary mucinous neoplasm with in situ adenocarcinoma, 5 had ampullary adenocarcinomas, 2 had intraductal papillary mucinous neoplasms, and 3 had benign diseases. In pathologic stage II or higher pancreatic ductal adenocarcinoma, moderate or high expression of S100A8 or S100A9 proteins was associated with a median disease recurrence-free survival of 5.8 months compared with 17.3 months in patients with low expression (P = 0.002). Median overall survival was 12.6 versus 27 months for patients with moderate to high versus low S100A8 and A9 expression (P = 0.02). CONCLUSIONS: This analysis suggests distinct proteomic signatures for pancreatic cancer. Patients in our study with elevated levels of S100A8 or A9 in the ductal fluid, a near absence of pancreatic enzymes, and high levels of mucins were found to have significantly worse prognosis. Although further validation is needed to corroborate these findings, analysis of pancreatic ductal fluid is a promising tool for identifying biomarkers of interest.


Subject(s)
Biomarkers, Tumor/metabolism , Calgranulin A/metabolism , Calgranulin B/metabolism , Mucins/metabolism , Pancreatic Neoplasms/metabolism , Adenocarcinoma, Mucinous/metabolism , Adenocarcinoma, Mucinous/pathology , Carcinoma in Situ/metabolism , Carcinoma in Situ/pathology , Carcinoma, Pancreatic Ductal/metabolism , Carcinoma, Pancreatic Ductal/pathology , Carcinoma, Papillary/metabolism , Carcinoma, Papillary/pathology , Humans , Kaplan-Meier Estimate , Mass Spectrometry/methods , Neoplasm Recurrence, Local , Pancreatic Juice/metabolism , Pancreatic Neoplasms/pathology , Prognosis , Proteome/metabolism , Proteomics/methods
2.
J Proteome Res ; 12(10): 4351-65, 2013 Oct 04.
Article in English | MEDLINE | ID: mdl-24004147

ABSTRACT

Plasma proteomic experiments performed rapidly and economically using several of the latest high-resolution mass spectrometers were compared. Four quantitative hyperfractionated plasma proteomics experiments were analyzed in replicates by two AB SCIEX TripleTOF 5600 and three Thermo Scientific Orbitrap (Elite/LTQ-Orbitrap Velos/Q Exactive) instruments. Each experiment compared two iTRAQ isobaric-labeled immunodepleted plasma proteomes, provided as 30 labeled peptide fractions, and 480 LC-MS/MS runs delivered >250 GB of data in 2 months. Several analysis algorithms were compared. At 1% false discovery rate, the relative comparative findings concluded that the Thermo Scientific Q Exactive Mass Spectrometer resulted in the highest number of identified proteins and unique sequences with iTRAQ quantitation. The confidence of iTRAQ fold-change for each protein is dependent on the overall ion statistics (Mascot Protein Score) attainable by each instrument. The benchmarking also suggested how to further improve the mass spectrometry parameters and HPLC conditions. Our findings highlight the special challenges presented by the low abundance peptide ions of iTRAQ plasma proteome because the dynamic range of plasma protein abundance is uniquely high compared with cell lysates, necessitating high instrument sensitivity.


Subject(s)
Blood Proteins/chemistry , Tandem Mass Spectrometry/methods , Blood Proteins/isolation & purification , Blood Proteins/metabolism , Humans , Immunoprecipitation , Peptide Mapping , Proteomics , Reference Standards , Reproducibility of Results , Sensitivity and Specificity , Tandem Mass Spectrometry/instrumentation , Tandem Mass Spectrometry/standards
3.
J Proteome Res ; 11(12): 5947-58, 2012 Dec 07.
Article in English | MEDLINE | ID: mdl-23082855

ABSTRACT

Immunodepletion of abundant plasma proteins increases the depth of proteome penetration by mass spectrometry. However, the nature and extent of immunodepletion and the effect of off-target depletion on the quantitative comparison of the residual proteins have not been critically addressed. We performed mass spectrometry label-free quantitation to determine which proteins were immunodepleted and by how much. Two immunodepletion resins were compared: Qproteome (Qiagen) which removes albumin+immunoglobulins and Seppro IgY14+SuperMix (Sigma-Aldrich) which removes 14 target proteins plus a number of unidentified proteins. Plasma collected by P100 proteomic plasma collection tubes (BD) from 20 human subjects was individually immunodepleted to minimize potential variability, prior to pooling. The abundant proteins were quantified better when using only albumin+immunoglobulins removal (Qproteome), while lower abundance proteins were evaluated better using exhaustive immunodepletion (Seppro IgY14+SuperMix). The latter resin removed at least 155 proteins, 38% of the plasma proteome in protein number and 94% of plasma protein in mass. The depth of immunodepletion likely accounts for the effectiveness of this resin in revealing low abundance proteins. However, the more profound immunodepletion achieved with the IgY14+SuperMix may lead to false-positive fold-changes between comparison groups if the reproducibility and efficiency of the depletion of a given protein are not considered.


Subject(s)
Blood Proteins/analysis , Immunoassay/methods , Mass Spectrometry/methods , Proteomics/methods , Albumins/chemistry , Blood Proteins/chemistry , Humans , Immunoglobulin G/chemistry , Isoelectric Focusing , Male , Peptides/analysis , Peptides/chemistry , Pulmonary Disease, Chronic Obstructive/blood , Reproducibility of Results , Sensitivity and Specificity
4.
J Biomol Tech ; 23(1): 11-23, 2012 Apr.
Article in English | MEDLINE | ID: mdl-22468137

ABSTRACT

Isobaric multiplexed quantitative proteomics can complement high-resolution sample isolation techniques. Here, we report a simple workflow exponentially modified protein abundance index (emPAI)-MW deconvolution (EMMOL) for normalizing isobaric reporter ratios within and between experiments, where small or unknown amounts of protein are used. EMMOL deconvolutes the isobaric tags for relative and absolute quantification (iTRAQ) data to yield the quantity of each protein of each sample in the pool, a new approach that enables the comparison of many samples without including a channel of reference standard. Moreover, EMMOL allows using a sufficient quantity of control sample to facilitate the peptide fractionation (isoelectric-focusing was used in this report), and mass spectrometry MS/MS sequencing yet relies on the broad dynamic range of iTRAQ quantitation to compare relative protein abundance. We demonstrated EMMOL by comparing four pooled samples with 20-fold range differences in protein abundance and performed data normalization without using prior knowledge of the amounts of proteins in each sample, simulating an iTRAQ experiment without protein quantitation prior to labeling. We used emPAI, the target protein MW, and the iTRAQ reporter ratios to calculate the amount of each protein in each of the four channels. Importantly, the EMMOL-delineated proteomes from separate iTRAQ experiments can be assorted for comparison without using a reference sample. We observed no compression of expression in iTRAQ ratios over a 20-fold range for all protein abundances. To complement this ability to analyze minute samples, we report an optimized iTRAQ labeling protocol for using 5 µg protein as the starting material.


Subject(s)
Escherichia coli Proteins/chemistry , Peptide Fragments/chemistry , Proteome/chemistry , Staining and Labeling/methods , Calibration , Escherichia coli Proteins/isolation & purification , Isoelectric Focusing/methods , Isoelectric Focusing/standards , Molecular Weight , Peptide Fragments/isolation & purification , Proteolysis , Proteome/isolation & purification , Proteomics , Reference Standards , Tandem Mass Spectrometry/methods , Tandem Mass Spectrometry/standards , Trypsin
SELECTION OF CITATIONS
SEARCH DETAIL
...