Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
J Metab Bariatr Surg ; 10(1): 42-45, 2021 Jun.
Article in English | MEDLINE | ID: mdl-36687751

ABSTRACT

Acute leakage after sleeve gastrectomy progresses into chronic leakage by 10-28.1%, which causes the surgeon to be disturbed. The main treatment for chronic leakage is surgery, but the authors report successful care with endoscopic septotomy. Forty-one year old female patient with a BMI of 42.8 (161.6 cm/111.8 kg) underwent a laparoscopic sleeve gastrectomy. The leakage of the proximal part of the staple resection line was verified in the abdominal CT on the fourth day after the procedure due to pain in the left shoulder that could not be clarified. After appropriate treatment including stent, the patient ended the acute leakage treatment 150 days after surgery. However, the patient was visited for 10 months after removed percutaneous catheter drainage due to fever and pain in the left shoulder. Afterwards, chronic leakage was confirmed from the CT and endoscopy at POD 15 months. We performed endoscopic treatment in the operating room under general anesthesia. At the gastroesophageal junction, we could find chronic leak orifice and bridging fold between stomach lumen and abscess pocket. Endoscopic septotomy was performed with the endoscopic knife and electrosurgical surgical unit, until the stomach lumen and abscess pockets were fully in communication. After the patient was discharged without any complications and is currently under close observation. Endoscopic septotomy as a treatment for chronic leak is feasible and safe. Herein, we report this case with video clip.

2.
J Bone Joint Surg Am ; 96(19): e168, 2014 Oct 01.
Article in English | MEDLINE | ID: mdl-25274796

ABSTRACT

BACKGROUND: We are aware of no study that has compared press-fit condylar Sigma fixed-bearing and mobile-bearing total knee prostheses in the same patients after more than ten years of follow-up. The purpose of the current study was to compare these two implants with respect to the functional and radiographic results, prevalence of osteolysis, and overall revision rates at a mean of 12.1 years of follow-up. METHODS: The study consisted of a consecutive series of 444 patients (mean age [and standard deviation], 66.5 ± 7.4 years) who underwent simultaneous bilateral total knee arthroplasty, with one side treated immediately after the other. All of the patients received a press-fit condylar Sigma mobile-bearing prosthesis on one side and a press-fit condylar Sigma fixed-bearing prosthesis on the contralateral side. The minimum duration of follow-up was ten years (mean, 12.1 years; range, ten to thirteen years). At the time of each follow-up visit, the patients were assessed clinically and radiographically. RESULTS: Postoperative total knee scores (95 and 94 points), Western Ontario and McMaster Universities Osteoarthritis Index (19 and 18 points), University of California, Los Angeles activity score (both prostheses, 5 points), range of motion (129° ± 6.3° and 127° ± 6.8°), and radiographic findings did not differ significantly between the press-fit condylar Sigma mobile and fixed-bearing designs at the final follow-up. The prevalence of aseptic loosening (1.4% and 1.8%) did not differ significantly between the mobile and fixed-bearing implant designs. No knee in either group had osteolysis. The estimated survival rate with revision as the end point was 98.2% (95% confidence interval, 91% to 99%) and 97.5% (95% confidence interval, 91% to 99%) at 12.1 years for the mobile and fixed-bearing implant groups, respectively. CONCLUSIONS: The results of the present long-term clinical study suggest that excellent clinical and radiographic results were achieved with both the press-fit condylar Sigma mobile and fixed-bearing cruciate-retaining total knee designs. We found no significant clinical advantage for a mobile-bearing over a fixed-bearing total knee prosthesis. LEVEL OF EVIDENCE: Therapeutic Level II. See Instructions for Authors for a complete description of levels of evidence.


Subject(s)
Knee Prosthesis , Prosthesis Design , Aged , Arthroplasty, Replacement, Knee/instrumentation , Female , Follow-Up Studies , Humans , Male , Prosthesis Failure , Range of Motion, Articular , Reoperation/statistics & numerical data , Treatment Outcome
3.
Int Orthop ; 37(11): 2131-7, 2013 Nov.
Article in English | MEDLINE | ID: mdl-23912267

ABSTRACT

PURPOSE: Very few studies have compared alumina-on-alumina ceramic and alumina-on-highly cross-linked polyethylene bearings in the same patient. The purpose of this prospective randomised study was to compare the clinical and radiographic results and the prevalence of osteolysis in cementless total hip arthroplasty using an alumina-on-alumina and alumina-on-highly cross-linked polyethylene bearings in young active patients. METHODS: We prospectively compared the results of 100 patients (200 hips) who had undergone a cementless total hip arthroplasty with an alumina-on-alumina ceramic bearing in one hip and an alumina-on-highly cross-linked polyethylene in the other. There were 66 men and 34 women with a mean age of 45.3 years (range, 21-49 years) at the time of surgery. The mean follow-up was 12.4 years (range, 11-13 years). The patients were assessed clinically and radiographically at three months, one year, and annually thereafter. RESULTS: Harris hip, Western Ontario and McMaster Universities Osteoarthritis Index, and University of California, Los Angeles activity scores did not show statistically significant differences between the two groups of bearings preoperatively or at the time of final follow-up. Radiographic findings of the component were not significantly different between the two groups. The mean polyethylene linear penetration was 0.031 ± 0.004 mm per year. No hips in either group displayed osteolysis. The Kaplan-Meier survivorship with revision as the end point at 12.4 years was 100% (95% confidence interval [CI], 94-100%) for the femoral component in both groups and 99% (95%CI, 93-100%) for the acetabular component. CONCLUSION: The clinical and radiographic results of using an alumina-on-alumina ceramic and alumina-on-highly cross-linked polyethylene bearings were similar.


Subject(s)
Ceramics , Hip Prosthesis , Osteoarthritis, Hip/surgery , Polyethylene , Adult , Arthroplasty, Replacement, Hip/instrumentation , Female , Follow-Up Studies , Hip Joint/diagnostic imaging , Hip Joint/surgery , Humans , Male , Middle Aged , Osteolysis/epidemiology , Prevalence , Prospective Studies , Radiography , Treatment Outcome
4.
Taehan Kan Hakhoe Chi ; 8(2): 132-8, 2002 Jun.
Article in Korean | MEDLINE | ID: mdl-12499798

ABSTRACT

BACKGROUND/AIMS: Hepatic glucuronidating activity, essential for efficient biliary excretion of bilirubin, is reduced to about 30 percent of normal in patients with Gilbert's syndrome. Patients with Gilbert's syndrome have an additional TA insertion in the A(TA)TAA of UDP-glucuronosyltransferase 1 (UGT-1A1) promoter gene. This results in reduced frequency and accuracy of transcription initiation and enzyme activity. The frequency and location of the mutation vary according to races. This study was done to determine the UGT-1A1 promoter gene mutation in Korean cases of Gilbert's syndrome. METHODS: Promoter regions of the gene for bilirubin UGT-1A1 in twelve patients with Gilbert's syndrome and twenty healthy subjects (controls) were sequenced. RESULTS: 1) Among twelve Gilbert's syndrome five patients were homozygous for A(TA)6/6TAA, two were homozygous for A(TA)7/7TAA, and the other five were heterozygous for A(TA)6/7TAA. The prevalence of A(TA)TAA mutation was 58.3 percent. 2) Among twenty healthy subjects seventeen were homozygous for A(TA)6/6TAA, one was homozygous for A(TA)7/7TAA, and two were heterozygous for A(TA)6/7TAA. The prevalence of A(TA)TAA mutation was 15 percent. 3) The prevalence of A(TA)TAA mutation in Gilbert's syndrome patients was significantly higher than in the controls (p=0.018). CONCLUSION: Although the prevalence of A(TA)TAA mutation in Korean patients with Gilbert's syndrome is significantly higher than in the controls, the mutations of the promoter region of UGT-1A1 gene appear not to be the main or sole cause in Gilbert's syndrome in Korea since the prevalence of A(TA)TAA mutation is not so high. Further studies to determine the relationship between other UGT-1A1 gene mutation and Gilbert's syndrome in Korea are needed.


Subject(s)
Gilbert Disease/genetics , Glucuronosyltransferase/genetics , Mutation , Polymorphism, Genetic , Promoter Regions, Genetic/genetics , Adult , Female , Gilbert Disease/enzymology , Humans , Korea , Male
SELECTION OF CITATIONS
SEARCH DETAIL
...