Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
J Affect Disord ; 115(3): 386-94, 2009 Jun.
Article in English | MEDLINE | ID: mdl-19027962

ABSTRACT

BACKGROUND: Optimal parameters of rTMS for antidepressant efficacy in general, or within patients, have not been adequately delineated. METHODS: Using a double-blind, sham-controlled, cross-over design, 22 adult patients with treatment refractory major depression (n=9; bipolar disorder, depressed phase) were randomized to active rTMS (20-Hz or 1-Hz) or sham rTMS conditions and given 5 rTMS treatments per week for two weeks. Repetitive TMS was administered at 100% of motor threshold for 1600 pulses over the left prefrontal cortex using a figure-eight coil. Patients initially randomized to sham rTMS were then exposed to two weeks of active rTMS with each frequency under blinded conditions. Those who received active 20-Hz and 1-Hz rTMS were crossed over to the opposite frequency for two weeks. Improvement in Hamilton Depression ratings were assessed after each two-week treatment phase. PET imaging was used to evaluate the patient's baseline absolute regional cerebral activity (blood flow and metabolism) as potential predictor of clinical response. RESULTS: Changes in depression severity on 1-Hz and 20-Hz rTMS were inversely correlated. PET scans with baseline hypoperfusion (but not hypometabolism) were associated with better improvement on 20-Hz rTMS as predicted. LIMITATIONS: The magnitude of the clinical change with either frequency at 100% motor threshold was not robust, and larger studies with higher intensities of rTMS for longer durations of time should be explored. CONCLUSIONS: High and low frequency rTMS exerts differential effects on depressed mood within individual subjects. The brain activity predictors and correlates of an optimal antidepressant response to rTMS remain to be better defined.


Subject(s)
Bipolar Disorder/therapy , Brain/blood supply , Depression/therapy , Depressive Disorder, Major/therapy , Electric Stimulation Therapy/methods , Positron-Emission Tomography , Adult , Bipolar Disorder/diagnostic imaging , Bipolar Disorder/physiopathology , Brain/diagnostic imaging , Brain/physiopathology , Cross-Over Studies , Depression/diagnostic imaging , Depression/physiopathology , Depressive Disorder, Major/diagnostic imaging , Depressive Disorder, Major/physiopathology , Dose-Response Relationship, Radiation , Double-Blind Method , Electromagnetic Phenomena , Female , Fluorodeoxyglucose F18/metabolism , Humans , Magnetoencephalography , Male , Positron-Emission Tomography/methods , Prefrontal Cortex/blood supply , Psychiatric Status Rating Scales , Research Design , Severity of Illness Index , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...