Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Heart Lung Circ ; 27(6): 702-707, 2018 Jun.
Article in English | MEDLINE | ID: mdl-28784571

ABSTRACT

BACKGROUND: An aberrant coronary artery is a rare clinical occurrence with an incidence of 0.05-1.2%. Often it is an incidental finding detected on coronary angiography or at autopsy. However, symptomatic patients can experience angina, arrhythmia, sudden death or non-specific symptoms such as dyspnoea and syncope. At present, there are no guidelines or dedicated studies assessing the treatment of an aberrant coronary artery leaving management options for these patients controversial. METHODS: Selected international cardiothoracic surgeons were surveyed electronically in November 2016 to determine whether consensus exists on different management aspects for patients with an aberrant coronary artery arising from the contralateral sinus with an interarterial course. RESULTS: For asymptomatic patients with either an aberrant left main coronary artery (ALMCA) arising from the contralateral sinus or an aberrant right main coronary artery (ARMCA) arising from the contralateral sinus, there was no consensus on surgical correction of the anomaly. If myocardial ischaemia was demonstrated on either coronary angiography with fractional flow reserve measurements and/or stress myocardial perfusion scan, surgical correction was the consensus between the surveyed surgeons. If surgery was deemed appropriate, coronary artery bypass surgery utilising the internal mammary artery was marginally preferred by the respondents in patients with an ALMCA whilst unroofing of the coronary ostium was preferred in patients with an ARMCA. Although no consensus was reached, a large proportion of respondents would not treat a patient over the age of 30 years differently compared to those under 30 years old. CONCLUSIONS: For symptomatic patients or if myocardial ischaemia is demonstrated on either coronary angiography with fractional flow reserve measurements and/or stress myocardial perfusion scan, surgical correction is indicated.


Subject(s)
Coronary Artery Bypass/methods , Coronary Vessel Anomalies/surgery , Coronary Vessels/surgery , Disease Management , Fractional Flow Reserve, Myocardial/physiology , Myocardial Ischemia/etiology , Adult , Coronary Angiography , Coronary Vessel Anomalies/complications , Coronary Vessel Anomalies/diagnosis , Coronary Vessels/diagnostic imaging , Female , Follow-Up Studies , Humans , Male , Myocardial Ischemia/diagnosis , Myocardial Ischemia/surgery , Retrospective Studies , Treatment Outcome
2.
Plast Reconstr Surg ; 139(5): 1084-1089, 2017 May.
Article in English | MEDLINE | ID: mdl-28445356

ABSTRACT

BACKGROUND: Breast augmentation surgery poses many challenges, and meeting the patient's expectations is one of the most important. Previous reports equate 100 cc to a one-cup-size increase; however, no studies have confirmed this between commercially available bras. The aim of this study was to identify the volume increase between cup sizes across different brands and the relationship with implant selection. METHODS: Five bra cup sizes from three different companies were analyzed for their volume capacity. Three methods were used to calculate the volume of the bras: (1) linear measurements; (2) volume measurement by means of water displacement; and (3) volume calculation after three-dimensional reconstruction of serial radiographic data (computed tomography). The clinical arm consisted of 79 patients who underwent breast augmentation surgery from February 1, 2014, to June 30, 2016. Answers from a short questionnaire in combination with the implant volume were analyzed. RESULTS: Across all three brands, the interval volume increase varied between sizes, but not all were above 100 cc. There was some variation in the volume capacity of the same cup size among the different brands. The average incremental increase in bra cup size across all three brands in the laboratory arm was 135 cc. The mean volume increase per cup size was 138.23 cc in the clinical arm. CONCLUSIONS: This article confirms that there is no standardization within the bra manufacturing industry. On the basis of this study, patients should be advised that 130 to 150 cc equates to a one-cup-size increase. Bras with narrower band widths need 130 cc and wider band widths require 150 cc to increase one cup size.


Subject(s)
Breast Implants , Clothing , Imaging, Three-Dimensional , Mammaplasty/methods , Tomography, X-Ray Computed , Breast/anatomy & histology , Female , Humans , Organ Size , Prosthesis Design
SELECTION OF CITATIONS
SEARCH DETAIL
...