1.
J Med Phys ; 48(3): 259-267, 2023.
Article in English | MEDLINE | ID: mdl-37969146

ABSTRACT

Aim: This article aimed to present the salient features of the in-house developed Java program for the determination of inflection point and dosimetric parameters of flattening filter-free (FFF) photon beam. Reference levels for the dosimetric parameters of the FFF photon beams were also presented. Materials and Methods: Beam profiles of 6 MV FFF and 10 MV FFF photon beams for a collimator setting of 20 cm × 20 cm measured at 10 cm depth in an isocentric setup acquired from various institutions were analyzed using an in-house developed Java program and manual method. The values of reference dose value (RDV), field size, penumbra, and degree of un-flatness (defined as the lateral separation between 90% [X90%], 75% [X75%], and 60% [X60%] dose points on the profile) were calculated and compared. The reference values of field size, penumbra, and degree of un-flatness were also determined for Varian and Elekta medical electron linear accelerators (LINACs). Results: The maximum differences for RDV determined using the Java method and manual method are 2.4% and 2.7% for 6 and 10 MV FFF photon beams, respectively. The maximum difference between the values of field size, penumbra, and degree of un-flatness determined using Java and manual methods is within 1.3 mm. The reference values of field size and penumbra for Varian LINACs are 19.94 ± 0.10 cm and 0.83 ± 0.08 cm (6 MV FFF) and 19.95 ± 0.10 cm and 0.83 ± 0.08 cm (10 MV FFF). Similarly, the reference values of field size and penumbra for Elekta LINACs are 20.02 ± 0.09 cm and 0.94 ± 0.12 cm (6 MV FFF) and 20.03 ± 0.11 cm and 0.97 ± 0.16 cm (10 MV FFF). Conclusions: A software program was developed in Java for analyzing the beam profiles of FFF photon beams. The results of Java-derived values of dosimetric parameters of FFF photon beams were found in good agreement with the values determined using the manual method. The reference values of these parameters were also derived and quoted using a large cohort of the data.

2.
Clin Oncol (R Coll Radiol) ; 31(1): e67-e74, 2019 01.
Article in English | MEDLINE | ID: mdl-30322681

ABSTRACT

AIMS: To report the findings of an audit for radiotherapy errors from a low-middle-income country (LMICs) centre. This would serve as baseline data for radiotherapy error rates, their severity and causes, in such centres where modern error reporting and learning processes still do not exist. MATERIALS AND METHODS: A planned cross-sectional weekly audit of electronic radiotherapy charts at the radiotherapy planning and delivery step for all patients treated with curative intent was conducted. Detailed analysis was carried out to determine the step of origin of error, time and contributing factors. They were graded as per indigenous institutional (TMC) radiotherapy error grading (TREG) system and the contributing factors identified were prioritised using the product of frequency, severity and ease of detection. RESULTS: In total, 1005 consecutive radically treated patients' charts were audited, 67 radiotherapy errors affecting 60 patients, including 42 incidents and 25 near-misses were identified. Transcriptional errors (29%) were the most common type. Most errors occurred at the time of treatment planning (59.7%), with "plan information transfer to the radiation oncology information system" being the most frequently affected sub-step of the radiotherapy process (47.8%). More errors were noted at cobalt units (52/67; 77.6%) than at linear accelerators. Trend analysis showed an increased number of radiotherapy incidents on Fridays and near-misses on Mondays. Trend for increased radiotherapy errors noted in the evening over other shifts. On severity grading, most of the errors (54/60; 90%) were clinically insignificant (grade I/II). Inadequacies and non-adherence towards standard operating procedures, poor documentation and lack of continuing education were the three most prominent causes. CONCLUSION: Preliminary data suggest a vulnerability of LMIC set-up to radiotherapy errors and emphasises the need for the development of longitudinal prospective processes, such as voluntary reporting and a continued education system, to ensure robust and comprehensive safe practises on par with centres in developed countries.


Subject(s)
Medical Errors/trends , Radiotherapy/methods , Commission on Professional and Hospital Activities , Cross-Sectional Studies , Humans , Poverty , Prospective Studies , Social Class
3.
J Med Phys ; 38(3): 139-42, 2013 Jul.
Article in English | MEDLINE | ID: mdl-24049321

ABSTRACT

The objective of this work was to investigate and quantify the effect of sharp edges of the phantom on the point dose measurement during patient-specific dosimetry with Rapid Arc (RA). Ten patients with carcinoma of prostate were randomly selected for this dosimetric study. Rapid Arc plans were generated with 6 MV X-rays in the Eclipse (v 8.6.14) with single arc (clockwise). Dosimetry verification plans were generated for two phantoms (cylindrical and rectangular). The cylindrical phantom was solid water (diameter 34 cm) and the rectangular phantom was a water phantom (25 cm × 25 cm × 10 cm). These phantoms were pre-scanned in computed tomography (CT) machine with cylindrical ionization chamber (FC65) in place. The plans were delivered with Novalis Tx linear accelerator with 6 MV X-rays for both the phantoms separately. The measured dose was compared with the planned dose for both the phantoms. Mean percentage deviation between measured and planned doses was found to be 4.19 (SD 0.82) and 3.63 (SD 0.89) for cylindrical and rectangular phantoms, respectively. No significant dosimetric variation was found due to the geometry (sharp edges) of the phantom. The sharp edges of the phantom do not perturb the patient specific Rapid Arc dosimetry significantly.

4.
Australas Phys Eng Sci Med ; 31(2): 139-45, 2008 Jun.
Article in English | MEDLINE | ID: mdl-18697705

ABSTRACT

Two-dimensional (2D) treatment verifications were performed for fifty patients planned and treated with helical tomotherapy (HT). The treatment verification consisted of an extended dose range (EDR2) film measurement as well as point dose measurements made with an A1SL ion chamber. The agreement between the calculated and the measured film dose distributions was evaluated with the gamma parameter calculated (3 mm and 3%). Good agreement was found between measured and calculated distributions with dose parameter registration using reference marks. The mean percent discrepancy for the point dose measurements was -0.4 (SD 1.4) for the high dose, low dose-gradient region. Thus the treatment verification results confirmed the safe delivery of the planned dose to the patient with helical tomotherapy.


Subject(s)
Body Burden , Delivery of Health Care/trends , Neoplasms/radiotherapy , Radiometry/methods , Radiotherapy, Conformal/methods , Radiotherapy, Conformal/trends , Female , Humans , India , Male , Radiotherapy Dosage , Relative Biological Effectiveness , Treatment Outcome
5.
Australas Phys Eng Sci Med ; 30(2): 127-34, 2007 Jun.
Article in English | MEDLINE | ID: mdl-17682402

ABSTRACT

A new model of the telecobalt unit (TCU), Theratron Equinox-80, (MDS Nordion, Canada) equipped with a single 60 degree motorized wedge (MW), four universal wedges (UW) for 15 degrees, 30 degrees, 45 degrees and 60 degrees have been evaluated. MW was commissioned in Eclipse (Varian, Palo Alto, USA) 3D treatment planning system (TPS). The profiles and central axis depth doses (CADD) were measured with Wellhofer blue water phantom for MW and the measured data was commissioned in Eclipse. These profiles and CADD for MW were compared with UW in a homogeneous phantom generated in Eclipse for various field sizes. The dose was also calculated in the same phantom at 10 cm depth. For the particular MW angle and the respective open and MW beam weights, the dose was measured for a field size of 10 cm x 10 cm in a MEDTEC water phantom at 10 cm depth with a 0.13 cc thimble ion chamber (Scanditronix Wellhofer, Uppsala, Sweden) and a NE electrometer (Nuclear Enterprises, UK). Measured dose with ion chamber was compared with the TPS calculated dose. MW angle verification was also done on the Equinox for four angles (15 degrees, 30 degrees, 45 degrees and 60 degrees). The variation in measured and calculated dose at 10 cm depth was within 2%. The measured and the calculated wedge angles were in good agreement within 2 degrees. The motorized wedges were successfully commissioned in Eclipse for four wedge angles.


Subject(s)
Cobalt , Phantoms, Imaging , Radiotherapy Planning, Computer-Assisted/instrumentation , Radiotherapy Dosage , Time Factors
6.
Australas Phys Eng Sci Med ; 30(1): 25-32, 2007 Mar.
Article in English | MEDLINE | ID: mdl-17508598

ABSTRACT

Purpose of this study was to report in a together our experience of using ion chambers, TLD, MOSFET and EDR2 film for dosimetric verification of IMRT plans delivered with dynamic multileaf collimator (DMLC). Two ion chambers (0.6 and 0.13 CC) were used. All measurements were performed with a 6MV photon beam on a Varian Clinac 6EX LINAC equipped with a Millennium MLC. All measurements were additionally carried out with (LiF:Mg,TI) TLD chips. Five MOSFET detectors were also irradiated. EDR2 films were used to measure coronal planar dose for 10 patients. Measurements were carried out simultaneously for cumulative fields at central axis and at off-axis at isocenter plane (+/- 1, and +/- 2 cm). The mean percentage variation between measured cumulative central axis dose with 0.6 cc ion chamber and calculated dose with TPS was -1.4% (SD 3.2). The mean percentage variation between measured cumulative absolute central axis dose with 0.13 cc ion chamber and calculated dose with TPS was -0.6% (SD 1.9). The mean percentage variation between measured central axis dose with TLD and calculated dose with TPS was -1.8% (SD 2.9). A variation of less than 5% was found between measured off-axis doses with TLD and calculated dose with TPS. For all the cases, MOSFET agreed within +/- 5%. A good agreement was found between measured and calculated isodoses. Both ion chambers (0.6 CC and 0.13 CC) were found in good agreement with calculated dose with TPS.


Subject(s)
Radiometry/instrumentation , Radiotherapy Planning, Computer-Assisted/instrumentation , Radiotherapy, Conformal/instrumentation , Equipment Design , Equipment Failure Analysis , Humans , Radiometry/methods , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Conformal/methods , Reproducibility of Results , Sensitivity and Specificity