J Clin Microbiol ; 39(5): 1788-90, 2001 May.
Article in English | MEDLINE | ID: mdl-11325991

ABSTRACT

In this study, we compared serum hepatitis C virus (HCV) RNA concentrations with HCV RNA concentrations in whole blood collection tubes, including two different types of EDTA tubes and nucleic acid stabilization tubes (NASTs). We also investigated the impact of a processing delay on HCV RNA concentration in these tubes. In NASTs, the mean HCV RNA concentration was comparable to the mean serum HCV RNA concentration at "date zero." In EDTA tubes, mean baseline HCV RNA concentrations were higher. Storage at room temperature up to 96 h did not result in a decline of HCV RNA concentration in any of the whole blood collection tubes. In NASTs, HCV RNA concentrations remained stable during the whole study period, whereas a significant increase of HCV RNA was observed in both types of EDTA tubes at 96 h compared to date zero. We concluded that HCV RNA remains stable in NASTs at room temperature for at least 96 h, allowing greater flexibility in sample collection and transport.


Subject(s)
Blood Specimen Collection , Blood/virology , Hepacivirus/isolation & purification , Hepatitis C/virology , RNA, Viral/blood , Adult , Blood Specimen Collection/instrumentation , Blood Specimen Collection/methods , Female , Humans , Male , Middle Aged