Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Sensors (Basel) ; 15(2): 3426-34, 2015 Feb 03.
Article in English | MEDLINE | ID: mdl-25690547

ABSTRACT

The phospholipid fatty acid (PLFA) content was determined in samples of Paracoccus denitrificans encapsulated in silica hydrogel films prepared from prepolymerized tetramethoxysilane (TMOS). Immediately after encapsulation the total PLFA concentration was linearly proportional to the optical density (600 nm) of the input microbial suspension (R2 = 0.99). After 7 days this relationship remained linear, but with significantly decreased slope, indicating a higher extinction of bacteria in suspensions of input concentration 108 cells/mL and higher. trans-Fatty acids, indicators of cytoplasmatic membrane disturbances, were below the detection limit. The cy/pre ratio (i.e., ratio of cyclopropylated fatty acids (cy17:0 + cy19:0) to their metabolic precursors (16:1ω7 + 18:1ω7)), an indicator of the transition of the culture to a stationary growth-phase, decreased depending on co-immobilization of nutrients in the order phosphate buffer > mineral medium > Luria Broth rich medium. The ratio, too, was logarithmically proportional to cell concentration. These results confirm the applicability of total PLFA as an indicator for the determination of living biomass and cy/pre ratio for determination of nutrient limitation of microorganisms encapsulated in sol-gel matrices. This may be of interest for monitoring of sol-gel encapsulated bacteria proposed as optical recognition elements in biosensor construction, as well as other biotechnological applications.


Subject(s)
Fatty Acids/chemistry , Hydrogels/chemistry , Paracoccus denitrificans/metabolism , Phospholipids/chemistry , Biosensing Techniques
2.
Microvasc Res ; 95: 53-9, 2014 Sep.
Article in English | MEDLINE | ID: mdl-25026413

ABSTRACT

The wavelet phase coherence of oscillations in the peripheral blood flow of contralateral skin sites was studied in 20 healthy subjects. Skin perfusion was registered simultaneously on similar regions of the outer sides of the right and left forearms by the laser Doppler flowmetry technique. To estimate the reliability of the obtained wavelet phase coherence values we applied the comparative method using amplitude-adjusted Fourier transform surrogates. High median values (0.63 and 0.59) of the wavelet phase coherence were obtained for the frequency intervals of respiratory (0.145-0.6Hz) and cardiac (0.6-2Hz) rhythms in 18 and 20 participants, respectively. In all the 20 participants we detected high and reliable values (Ме=0.72) of the wavelet phase coherence for skin blood flow oscillations in the myogenic interval (0.052-0.145Hz). Additionally, we demonstrated high wavelet phase coherence in the neurogenic (0.021-0.052Hz) and endothelial (0.0095-0.021Hz) intervals in 8 and 7 participants, respectively. The corresponding medians of the reliable wavelet phase coherence values for these intervals were 0.74 and 0.82. The obtained results suggest that the microvascular blood flow possesses not only the local mechanisms of generating low-frequency blood flow oscillations, but also a central mechanism, which is likely to synchronize low-frequency oscillations throughout the whole cardiovascular system.


Subject(s)
Laser-Doppler Flowmetry , Microcirculation , Periodicity , Skin/blood supply , Wavelet Analysis , Adolescent , Blood Flow Velocity , Female , Fourier Analysis , Healthy Volunteers , Humans , Oscillometry , Predictive Value of Tests , Regional Blood Flow , Reproducibility of Results , Time Factors , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...