Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 33
Filter
1.
Ann Vasc Surg ; 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38960094

ABSTRACT

Vascular access for hemodialysis is the lifeline for patients with end-stage renal disease (ESRD); therefore, maintenance of the vascular access is of the utmost importance. The dialysis circuit can be complicated by stenosis or thrombosis. In particular, central venous stenosis is frequently encountered in the vascular access of patients with ESRD, and this complication may require endovascular management. Conventional catheter-based venography may be inadequate for identifying dynamic forms of extrinsic compression and intravascular webs associated with these lesions. For these types of access complications, balloon angioplasty remains the first-line intervention, with stenting reserved for select scenarios. Accurate assessment of the venous configuration is therefore important to ensure an adequate treatment response. Intravascular ultrasound (IVUS) has been shown to be beneficial in lower extremity venous interventions. The use of IVUS in dialysis access interventions is currently limited but may be indicated in select challenging clinical situations. In this article, we discuss the potential uses of IVUS in the ESRD population based on our institutional experience and on the current literature.

2.
J Clin Med ; 13(10)2024 May 07.
Article in English | MEDLINE | ID: mdl-38792273

ABSTRACT

Background/Objectives: To evaluate radiation exposure in standard interventional radiology procedures using a twin robotic X-ray system compared to a state-of-the-art conventional angiography system. Methods: Standard interventional radiology procedures (port implantation, SIRT, and pelvic angiography) were simulated using an anthropomorphic Alderson RANDO phantom (Alderson Research Laboratories Inc. Stamford, CT, USA) on an above-the-table twin robotic X-ray scanner (Multitom Rax, Siemens Healthineers, Forchheim, Germany) and a conventional below-the-table angiography system (Artis Zeego, Siemens Healthineers, Forchheim, Germany). The phantom's radiation exposure (representing the potential patient on the procedure table) was measured with thermoluminescent dosimeters. Height-dependent dose curves were generated for examiners and radiation technologists in representative positions using a RaySafe X2 system (RaySafe, Billdal, Sweden). Results: For all scenarios, the device-specific dose distribution differs depending on the imaging chain, with specific advantages and disadvantages. Radiation exposure for the patient is significantly increased when using the Multitom Rax for pelvic angiography compared to the Artis Zeego, which is evident in the dose progression through the phantom's body as well as in the organ-related radiation exposure. In line with these findings, there is an increased radiation exposure for the performing proceduralist, especially at eye level, which can be significantly minimized by using protective equipment (p < 0.001). Conclusions: In this study, the state-of-the-art conventional below-the-table angiography system is associated with lower radiation dose exposures for both the patient and the interventional radiology physician compared to an above-the-table twin robotic X-ray system for pelvic angiographies. However, in other clinical scenarios (port implantation or SIRT), both devices are suitable options with acceptable radiation exposure.

3.
Ann Vasc Surg ; 98: 131-136, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37356655

ABSTRACT

BACKGROUND: Acute type B aortic dissections (TBADs) can become complicated at any time point, necessitating surgical repair. We sought to investigate the effect of interhospital transfer on the development of delayed complications in acute type B aortic dissection (dcTBAD). METHODS: All patients who presented with acute TBAD to a tertiary aortic center from 2015 to 2019 were analyzed. Patients were divided into initially complicated type B aortic dissection (icTBAD) (0-24 hours from symptom onset), dcTBAD (25 hours to 14 days), and uncomplicated type B aortic dissection (ucTBAD) groups. Criteria for complicated dissection were aortic rupture, malperfusion, or rapid aortic growth. Demographics, patient history, the timing of presentation, imaging findings, and clinical outcomes were compared between groups. RESULTS: Of 120 acute TBADs included, 27 (22%) were initially complicated (aortic rupture, n = 9; malperfusion, n = 18). Twenty-one (18%) developed delayed complications (aortic rupture, n = 3; malperfusion, n = 14; rapid growth, n = 4) at a median of 7.0 [4.0, 9.0] days from symptom onset. Seventy-two (60%) remained uncomplicated. Overall, 111 (93%) presented as transfers from outside hospitals (icTBAD, n = 25; dcTBAD, n = 21; ucTBAD, n = 65). Of those, dcTBADs were more likely to have a prolonged delay between presentation to the outside hospital and referral to the tertiary center compared to ucTBADs (median = 1.00 [0.0, 5.0] days delayed vs. 0.00 [0.0, 0.0] days delayed; P < 0.001). Initially uncomplicated patients referred for transfer ≥24 hours from presentation went on to develop dcTBAD more often than those transferred in <24 hours (73% vs 13%; P < 0.001). Of dcTBADs, 38% had no high-risk features on initial imaging. Patients with dcTBAD had significantly longer length of stay (median = 12 vs 7 days; P = 0.006). In-hospital mortality was significantly higher in dcTBADs than ucTBADs (9.5% vs 0%; P = 0.047). In-hospital mortality was not significantly different between dcTBADs and icTBADs (9.5% vs. 11%; P > 0.05). CONCLUSIONS: The incidence and consequence of dcTBADsare not insignificant. Late referral and transfer to a tertiary aortic center (≥24 hours from initial presentation) was associated with dcTBADsrequiring surgical intervention. The development of dcTBADwas associated with increased length of stay and increased in-hospital mortality.


Subject(s)
Aortic Aneurysm, Thoracic , Aortic Dissection , Aortic Rupture , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Humans , Aortic Rupture/diagnostic imaging , Aortic Rupture/surgery , Aortic Rupture/etiology , Patient Transfer , Acute Disease , Treatment Outcome , Aortic Dissection/diagnostic imaging , Aortic Dissection/surgery , Referral and Consultation , Retrospective Studies , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/surgery , Aortic Aneurysm, Thoracic/etiology , Risk Factors , Blood Vessel Prosthesis Implantation/adverse effects
4.
Ann Vasc Surg ; 98: 102-107, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37423328

ABSTRACT

BACKGROUND: Complex open abdominal aortic aneurysm (AAA) repair often necessitates revascularization of renal arteries by either renal artery reimplantation or bypass. This study aims to evaluate the perioperative and short term outcomes between these 2 strategies of renal artery revascularization. METHODS: We performed a retrospective review of patients who underwent open AAA repair from 2004 to 2020 at our own institution. Patients who underwent elective suprarenal, juxtarenal, or type 4 thoracoabdominal aneurysm repair were identified using current procedural terminology (CPT) codes and a retrospectively maintained database of AAA patients. Patients who had symptomatic aneurysm or significant renal artery stenosis before AAA repair were excluded. Patient demographics, intraoperative conditions, renal function, bypass patency, and perioperative and postoperative outcomes at 30 days and 1 year were compared. RESULTS: One hundred and forty-three patients underwent either renal artery reimplantation (n = 86) or bypass (n = 57) during this time period. The mean age was 69.7 years and 76.2% of the patients were male. Median preoperative creatinine was 1.2 mg/dL for the renal bypass group versus 1.06 mg/dL for reimplantation (P = 0.088). Both groups had similar median preoperative glomerular filtration rate (GFR) of >60 mL/min (P = 0.13). Bypass and reimplantation groups had similar perioperative complications including acute kidney injury (51.8% vs. 49.4% P = 0.78), inpatient dialysis (3.6% vs. 1.2% P = 0.56), myocardial infarction (1.8% vs. 2.4% P = 0.99), and death (3.5% vs. 4.7% P = 0.99), respectively. During the 30-day follow-up period, renal artery stenosis was identified in 9.8% of bypasses and 6.7% of reimplantations (P = 0.71). Six point one percent of patients in the bypass group had renal failure requiring dialysis (both acute and permanent) compared to 1.3% in reimplantation group (P = 0.3). For those who had 1-year follow-up, the reimplantation group had higher new incidence of renal artery stenosis compared to bypass group (6 vs. 0 P = 0.16). CONCLUSIONS: Given that there is no significant difference in outcomes between renal artery reimplantation and bypass within 30 days or at 1-year follow-up, both bypass and reimplantation are acceptable means for renal artery revascularization during elective AAA repair.


Subject(s)
Acute Kidney Injury , Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Renal Artery Obstruction , Humans , Male , Aged , Female , Renal Artery/diagnostic imaging , Renal Artery/surgery , Retrospective Studies , Treatment Outcome , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/surgery , Aortic Aneurysm, Abdominal/complications , Acute Kidney Injury/diagnosis , Acute Kidney Injury/etiology , Replantation/adverse effects , Blood Vessel Prosthesis Implantation/adverse effects , Risk Factors , Postoperative Complications/etiology
5.
Vasc Med ; 28(6): 592-603, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37792749

ABSTRACT

The spectrum of venous thromboembolic (VTE) disease encompasses both acute deep venous thrombosis (DVT) and chronic postthrombotic changes (CPC). A large percentage of acute DVT patients experience recurrent VTE despite adequate anticoagulation, and may progress to CPC. Further, the role of iliocaval venous obstruction (ICVO) in lower-extremity VTE has been increasingly recognized in recent years. Imaging continues to play an important role in both acute and chronic venous disease. Venous duplex ultrasound remains the gold standard for diagnosing acute VTE. However, imaging of CPC is more complex and may involve computed tomography, magnetic resonance, contrast-enhanced ultrasound, or intravascular ultrasound. In this narrative review, we aim to discuss the full spectrum of venous disease imaging for both acute and chronic venous thrombotic disease.


Subject(s)
Postthrombotic Syndrome , Venous Thromboembolism , Venous Thrombosis , Humans , Venous Thromboembolism/diagnostic imaging , Veins , Venous Thrombosis/diagnostic imaging , Lower Extremity/blood supply , Chronic Disease , Acute Disease
7.
J Vasc Surg ; 78(3): 633-637, 2023 09.
Article in English | MEDLINE | ID: mdl-37182816

ABSTRACT

OBJECTIVE: Aneurysmal pathology of the aorta is well-defined in the Marfan syndrome (MFS) population. Owing in part to the rarity of pathologies, the prevalence of intracranial aneurysms (IA) in MFS is poorly defined. There is debate as to whether or not there is an association between the two. The aim of this study was to evaluate the prevalence of IA in a population of patients with MFS who underwent intracranial imaging. METHODS: This was a single-center retrospective review of patients with MFS. Between 1995 and 2021, 983 patients were reviewed. We identified 198 patients with MFS who had intracranial imaging. Imaging consisted of CTA and/or MRA, and was read by an attending radiologist. Details of the aneurysm, patient demographics, and aortic characteristics were collected. RESULTS: The prevalence of IA was 7.1% (14/198). Age of patients with IA (55.0 ± 15.1 years) was not significantly different than those without IA (52.6 ± 16.0 years) (P = .58). The most common location of IA was the internal carotid artery. The mean diameter of the IA was 7 ± 5.8 mm. No ruptures of the internal carotid artery were identified. One patient (0.5%) underwent intervention for the IA. There were no significant differences found in aortic characteristic including dimensions, history of dissection, or aneurysm. CONCLUSIONS: In a large, single-center experience over 20 years, we identified patients with confirmed MFS who underwent intracranial imaging. The prevalence of IA in our experience was 7.1%. There were no patient or aortic characteristics found to be significantly associated with IA; however, this finding may be due to the small number of aneurysms. Although this number is higher than the historically reported prevalence in the general population, a collection of experiences from multiple institutions will likely be required to truly define the risk of IA in MFS and to determine whether screening is warranted.


Subject(s)
Intracranial Aneurysm , Marfan Syndrome , Humans , Adult , Middle Aged , Aged , Marfan Syndrome/complications , Marfan Syndrome/diagnosis , Marfan Syndrome/epidemiology , Intracranial Aneurysm/diagnostic imaging , Intracranial Aneurysm/epidemiology , Intracranial Aneurysm/etiology , Prevalence , Aorta , Retrospective Studies
8.
Ann Vasc Surg ; 96: 166-175, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37169247

ABSTRACT

BACKGROUND: Cardiovascular complications are a major cause of morbidity and mortality in the postoperative period after major vascular surgery. Depending on the study population, up to 25% of patients have troponin elevation after noncardiac surgery, yet many do not meet the diagnosis of myocardial infarction (MI). Although outcomes of routine troponin elevation in patients undergoing mixed major vascular surgery have been evaluated, this has not been studied exclusively in elective, open abdominal aortic aneurysm repair (oAAA), especially regarding perioperative and overall mortality. METHODS: We conducted a single-center, retrospective review of routine troponin surveillance for consecutive, oAAA from 2014 to 2019. A total of 319 patients were identified and analyzed for management patterns and interventions. The cohort was stratified into groups for comparison based on those in whom troponin was routinely checked (RC) as part of a care strategy during the study period, not routinely checked (NRC), elevated troponin (ET) >0.001 ng/mL, and not elevated. The median follow-up was 21.5 ± 23.8 months. Groups were compared on demographic data, cardiac comorbidities, 30-day and 3-year outcomes for MI and death using two-sample t-tests, Wilcoxon rank sum tests, Pearson chi-square tests, and Fisher exact tests when appropriate. RESULTS: Troponin was measured in 83.7% (267/319) of patients who underwent elective oAAA repair. Routine troponin checks were obtained in 79.9% (255/319) of patients. ET was identified in 16.5% of those with RC (42/255) and 4.7% of those with NRC (3/64). Of patients with ET, 37.8% (17/45) had a cardiology consultation, 4.4% (2/45) had a percutaneous coronary intervention (PCI), and 4.4% (2/45) had another cardiac intervention. All 4 patients undergoing PCI or other cardiac intervention had received routine troponin checks. Patients with ET were older (71.2 vs. 68.6; P = 0.04), more likely to receive intraoperative blood products (P = 0.003), had longer operative times (P = 0.011), higher length of stay (9 vs. 7 days; P < 0.01), and higher 30-day MI rate (3 vs. 0; P = 0.04). They had neither longer aortic clamp times nor worse preoperative cardiac function, and the proximal clamp position during oAAA repair did not impact troponin detection. Additionally, 3-year overall mortality was increased in patients who had ET but there was not a significant difference in 3-year mortality between groups receiving routine troponin checks versus not. CONCLUSIONS: ET, identified after elective oAAA repair, was associated with a higher risk of 30-day MI and lower overall survival. However, it was not demonstrated that routine assessment of troponin levels postoperatively leads to decreased 3-year mortality in this setting.


Subject(s)
Aortic Aneurysm, Abdominal , Myocardial Infarction , Percutaneous Coronary Intervention , Plastic Surgery Procedures , Humans , Treatment Outcome , Vascular Surgical Procedures/adverse effects , Myocardial Infarction/diagnosis , Myocardial Infarction/etiology , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/surgery
9.
Cardiovasc Diagn Ther ; 13(1): 190-195, 2023 Feb 28.
Article in English | MEDLINE | ID: mdl-36864960

ABSTRACT

The rise in prevalence of end stage renal disease (ESRD) and the impact on health care resulted in increasing focus on delivery of vascular access. Hemodialysis vascular access is the most common renal replacement therapy method. The vascular access types include arteriovenous fistula, arteriovenous graft, and tunneled central venous catheters. Vascular access function remains an important outcome measure with significant impact on morbidity and health care cost. The survival and quality of life of patients on hemodialysis is dependent on the adequacy of dialysis through proper vascular access. Early detection of failure to mature vascular access, stenosis, thrombosis, and aneurysm or pseudoaneurysm formation remains crucial. Ultrasound can help identify complications, even though ultrasound evaluation of the arteriovenous access is less well defined. Some published vascular access guidelines support ultrasound for detecting stenosis. The evolution of ultrasound has improved throughout the years, both multi parametric top-line systems and hand-held systems. Ultrasound evaluation is inexpensive, rapid, noninvasive, and repeatable, it is a powerful tool used for early diagnosis. The ultrasound image quality still depends on the skill of the operator. Careful attention to technical details is needed and avoidance of several diagnostic pitfalls is necessary. This review is focused on the role of ultrasound for hemodialysis access surveillance, evaluation of maturation, detection of access complications, and aid with cannulation.

11.
Vascular ; : 17085381221141737, 2023 Feb 19.
Article in English | MEDLINE | ID: mdl-36802992

ABSTRACT

OBJECTIVE: Hypogastric coverage may be required for occlusive disease at the iliac arterial bifurcation. In this study, we sought to determine patency rates of common-external iliac artery (C-EIA) bare metal stents (BMS) spanning the hypogastric origin in patients with aortoiliac occlusive disease (AIOD). In addition, we sought to identify predictors of C-EIA BMS patency loss and major adverse limb events (MALE) in patients requiring hypogastric coverage. We hypothesized that worsening stenosis of the hypogastric origin would negatively influence C-EIA stent patency and freedom from MALE. METHODS: This is a single center, retrospective review of consecutive patients undergoing elective, endovascular treatment of aortoiliac disease (AIOD) between 2010 and 2018. Only patients with C-EIA BMS coverage of a patent IIA origin were included in the study. Hypogastric luminal diameter was determined from preoperative CT angiography. Analysis was performed using Kaplan-Meier survival analysis, univariable and multivariable logistic regression, and receiver operator characteristics (ROC). RESULTS: There were 236 patients (318 limbs) who were included in the study. AIOD was TASC C/D in 236/318 (74.2%) of cases. C-EIA stent primary patency was 86.5% (95% confidence interval: 81.1, 91.9) at 2 years and 79.7% (72.8, 86.7) at 4 years. Freedom from ipsilateral MALE was 77.0% (71.1, 82.9) at 2 years and 68.7% (61.3, 76.2) at 4 years. Luminal diameter of the hypogastric origin was most strongly associated with loss of C-EIA BMS primary patency in multivariable analysis (hazard ratio: 0.81, p = .02). Insulin-dependent diabetes, Rutherford's class IV or above, and stenosis of the hypogastric origin were significantly predictive of MALE in both univariable and multivariable analyses. In ROC analysis, luminal diameter of the hypogastric origin was superior to chance in prediction of C-EIA primary patency loss and MALE. Hypogastric diameter >4.5 mm had a negative predictive value of 0.94 for C-EIA primary patency loss and 0.83 for MALE. CONCLUSIONS: Patency rates of C-EIA BMS are high. Hypogastric luminal diameter is an important and potentially modifiable predictor of C-EIA BMS patency and MALE in patients with AIOD.

12.
J Vasc Surg ; 77(5): 1322-1329, 2023 05.
Article in English | MEDLINE | ID: mdl-36791895

ABSTRACT

OBJECTIVES: The precise number of actively practicing vascular surgeons who self-identify as Black American and the historical race composition trends within the overall profession of vascular surgery are unknown. Limited demographic data have been collected and maintained at the societal or national board level. Vascular surgery societal reports suggest that less than 2% of vascular surgeons identify as Black American. Black Americans comprise 13.4% of the U.S. population yet for disorders such as peripheral artery disease and end-stage renal disease, Black communities are disproportionately impacted, and the prevalence of disease is greater on an age-adjusted basis. A significant body of research shows that clinical outcomes such as medication adherence, shared decision-making, and research trial participation are positively impacted by racial concordance especially for communities in whom distrust is high as a consequence of historic experiences. This survey aims to characterize practice and career variables within a network of Black American vascular surgeons. METHODS: A cross-sectional survey was conducted via a questionnaire sent to all participants of the Society of Black Vascular Surgeons that began to convene monthly during the COVID-19 pandemic and experienced subsequent organic growth. The survey included 20 questions with variables quantified including the surgeon's demographics, clinical experience, practice setting, patient demographics, and professional society engagement. RESULTS: Fifty-nine percent of the Society of Black Vascular Surgeons members completed the survey. Males comprised 81% of the responding vascular surgeons. The majority (62%) of respondents were involved in academic practice. Less than 25% of the total medical staff were Black American in 77% of the respondents' current work practice. The patient racial composition within their respective practice settings was as follows: White (47%), Black (34%), Hispanic (13%), Asian (3%), Middle Eastern or North African (2%), and American Indian and Alaskan Natives (0.4%). Forty-three percent of respondents had a current active membership in the Society for Vascular Surgery, and 24% had a regional society membership. Fifty-eight percent of respondents reported that they experienced a workplace event that they felt was racially or ethically driven in the 12 months before the survey. CONCLUSIONS: This survey describes an under-represented in medicine vascular surgeon subgroup that has not heretofore been characterized. Racial and ethnic demographic data are essential to better understand the current demographic makeup of our specialty and to develop benchmark goals of race composition that mirrors our society at large. The patients of this group of Black American vascular surgeons were more likely to represent a racial minority. Efforts to increase race diversity in vascular surgery have the potential benefit of enhancing care of patients with vascular disease.


Subject(s)
COVID-19 , Surgeons , Male , Humans , United States/epidemiology , Female , Cross-Sectional Studies , Pandemics , Workforce , Vascular Surgical Procedures
13.
Ann Vasc Surg ; 93: 300-307, 2023 Jul.
Article in English | MEDLINE | ID: mdl-36641088

ABSTRACT

BACKGROUND: Strategies for embolization of type 2 endoleaks include translumbar, transgraft, transarterial, and transcaval approaches. The transcaval approach is limited by an inconsistent ability to access the aortic sac and the risk of puncturing and damaging the endograft or adjacent structures. We describe a novel technique for caval to aortic aneurysm sac access and report early outcomes. METHODS: A retrospective review of all patients who underwent transcaval embolization (TCE) at a tertiary referral center. From March 2019 to June 2021, 12 patients were identified to have undergone a novel approach to transcaval aortic sac access using a 0.014″ heavy weight tip wire guide and continuous current electrocautery to create the connection between the inferior vena cava and aortic aneurysm sac. The endoleak outflow vessel is then selectively embolized with coils or liquid embolic agents. When selective embolization was not possible, the aneurysm sac was instilled with liquid embolic agents to induce thrombosis. RESULTS: Twelve patients underwent transcaval embolization using this method over the 3-year period. The average patient age was 79.2 ± 6.2 years and 10/12 (83.3%) were male. A high rate of comorbidities was noted in the cohort. Transcaval access into the aortic sac was achieved in all patients, while selective cannulation of outflow vessels was accomplished in 2/12 (16%) target vessels. Of these, both cases had vessels embolized using detachable coils and liquid embolic agents. Nonselective embolization was performed using liquid embolic and thrombotic agents in the other 10/12 cases. There was one perioperative complication of minor bleeding (1/12, 8.3%). Two patients were observed in intensive care unit for back pain. A persistent endoleak was identified on postoperative imaging performed at 30 days in 4/12 (33.3%) patients. Sac enlargement > 5 mm following TCE was observed in 3/12 (25%) patients. Three patients underwent open conversion with endovascular aneurysm repair explant. One patient was explanted at 1 month after failure to embolize the endoleak flow channel using TCE. A second was explanted for persistent endoleak found to be a Type IIIb with aortic diameter growth > 5 mm at 15-month follow-up. The third explant was performed for aortic sac infection at 4 months postprocedure without endoleak. CONCLUSIONS: TCE is an adjunctive technique to treat endoleaks in patients who have either failed transarterial or translumbar access. An electrified 0.014″ chronic total occlusion wire technique for transcaval access to the aortic sac for endoleak embolization can be successful in all cases without significant acute morbidity or mortality. The transcaval approach is still limited by ability to steer catheters and microcatheters into the outflow vessels with a resultant persistent endoleak and eventual need for explant.


Subject(s)
Aortic Aneurysm, Abdominal , Aortic Aneurysm , Blood Vessel Prosthesis Implantation , Embolization, Therapeutic , Endovascular Procedures , Humans , Male , Aged , Aged, 80 and over , Female , Endoleak/diagnostic imaging , Endoleak/etiology , Endoleak/therapy , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/surgery , Aortic Aneurysm, Abdominal/complications , Blood Vessel Prosthesis Implantation/adverse effects , Treatment Outcome , Endovascular Procedures/adverse effects , Aortic Aneurysm/surgery , Embolization, Therapeutic/adverse effects , Embolization, Therapeutic/methods , Retrospective Studies
14.
J Vasc Surg ; 77(2): 625-631.e8, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36007844

ABSTRACT

OBJECTIVES: Vascular surgery integrated residency (VSIR) programs are highly competitive; however, criteria for resident selection remain opaque and non-standardized. The already unclear selection criteria will be further impacted by the impending transition of the United States Medical Licensing Examination (USMLE) Step 1 from numeric scores to a binary pass/fail outcome. The purpose of this study was to investigate the historical and anticipated selection criteria of VSIR applicants. METHODS: This was a cross-sectional, nationwide, 59-item survey that was sent to all VSIR program directors (PDs). Data was analyzed using the Fisher exact test if categorical and the Mann-Whitney U test and the Kruskal-Wallis test if ordinal. RESULTS: Forty of 69 PDs (58%) responded to the survey. University-based programs constituted 85% of responders. Most VSIR PDs (65%) reported reviewing between 101 to 150 applications for 1 to 2 positions annually. Forty-two percent of the responding PDs reported sole responsibility for inviting applicants to interview, whereas 50% had a team of faculty responsible for reviewing applications. On a five-point Likert scale, letters of recommendation (LOR) from vascular surgeons or colleagues (a person the PD knows) were the most important objective criteria. Work within a team structure was rated highest among subjective criteria. The majority of respondents (72%) currently use the Step 1 score as a primary method to screen applicants. Regional differences in use of Step 1 score as a primary screening method were: Midwest (100%), Northeast (76%), South (43%), and West (40%) (P = .01). PDs responded that that they will use USMLE Step 2 score (42%) and LOR (10%) to replace USMLE Step 1 score. The current top ranked selection criteria are letters from a vascular surgeon, USMLE Step 1 score and overall LOR. The proposed top ranked selection criteria after transition of USMLE Step 1 to pass/fail include LOR overall followed by Step 2 score. CONCLUSIONS: This is the first study to evaluate the selection criteria used by PDs for VSIR. The landscape of VSIR selection criteria is shifting and increasing transparency is essential to applicants' understanding of the selection process. The transition of USMLE Step 1 to a pass/fail report will shift the attention to Step 2 scores and elevate the importance of other relatively more subjective criteria. Defining VSIR program selection criteria is an important first step toward establishing holistic review processes that are transparent and equitable.


Subject(s)
Internship and Residency , Specialties, Surgical , Humans , United States , Patient Selection , Cross-Sectional Studies , Vascular Surgical Procedures , Educational Measurement
15.
J Vasc Surg ; 77(2): 446-453.e3, 2023 02.
Article in English | MEDLINE | ID: mdl-36028158

ABSTRACT

OBJECTIVE: This study reports the results of a prospective, multicenter trial designed to evaluate the safety and effectiveness of the polymer based Endologix Alto Stent Graft System in treating abdominal aortic aneurysms (AAAs), with sealing 7 mm below the top of the fabric in aortic neck diameters from 16 to 30 mm. METHODS: Seventy-five patients were treated with Alto devices between March 2017 and February 2018 in 16 centers in the United States for infrarenal AAAs (max diameter ≥5.0 cm in diameter or size increase by 0.5 cm in 6 months or diameter ≥1.5 times the adjacent normal aorta). Patients were followed for 30 days, 6 months, and 1 year by clinical evaluation and computed tomography and abdominal x-ray imaging. Treatment success was defined as technical success and freedom from AAA enlargement, migration, type I or III endoleak, AAA rupture or surgical conversion, stent graft stenosis, occlusion, kink, thromboembolic events, and stent fracture attributable to the device requiring secondary intervention through 12 months. Preoperative characteristics, perioperative variables, follow-up clinical evaluations, and radiographic examination results through the first 1 year were analyzed. RESULTS: The mean patient age was 73 years, with 93% of patients being male. The 30-day major adverse event rate was 5.3%. At 1 year, the primary endpoint was met with a treatment success rate of 96.7%. Through 1-year post-treatment, all-cause mortality was 4.0%. No AAA-related mortality occurred. AAA enlargement was 1.6%, type I endoleak rate was 1.4%, with 100% freedom from type III endoleaks, device migration, device fracture, stent occlusion, or AAA rupture. The device-related secondary intervention rate was 2.7%. CONCLUSIONS: This prospective study demonstrates the Endologix Alto is safe and effective in treating AAAs with appropriate anatomy at 1 year. The safety endpoint is met by a 5.3% 30-day major adverse event rate, whereas the effectiveness endpoint is met by a treatment success rate of 96%.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Humans , Male , United States , Aged , Female , Blood Vessel Prosthesis/adverse effects , Prospective Studies , Endoleak/diagnostic imaging , Endoleak/etiology , Endoleak/therapy , Prosthesis Design , Stents/adverse effects , Treatment Outcome , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/surgery , Aortic Aneurysm, Abdominal/complications
16.
Wounds ; 34(4): E22-E28, 2022 04.
Article in English | MEDLINE | ID: mdl-35797556

ABSTRACT

INTRODUCTION: Surgical site infection (SSI) of groin incisions after vascular surgery is a significant source of morbidity and is associated with high rates of readmission and reoperation, as well as longer hospital length of stay. The patient-reported health care experiences are diminished for those in whom SSI complications occur. Previous studies have analyzed patients undergoing all types of surgery requiring groin incision. The role of closed incision negative pressure therapy (CiNPT) as an adjunct to the primarily closed femoral incision after vascular surgery is unclear. MATERIALS AND METHODS: This retrospective single-center study focuses on complex iliofemoral reconstruction with extensive dissection, including profundoplasty. The role of CiNPT and short-term outcomes are analyzed. Multivariable logistic regression was used to identify factors that place patients at high risk for SSI. A prediction model was performed to predict high-risk patients. RESULTS: A total of 337 patients who underwent 422 femoral endarterectomies (85 bilateral) were included. The overall SSI rate was 16.1% (9.3% Szilagyi grade II and III), and SSI was associated with a 44% readmission rate, 38% reoperation rate, and longer mean length of stay (8.5 days vs 5.1 days; P =.02). No differences in SSI were evident between the CiNPT (n = 47) and standard dressing cohorts. The final prediction model used 5 variables: obesity (body mass index > 30), insulin use, chronic obstructive pulmonary disease (COPD), immunosuppression, and surgical duration. CONCLUSIONS: Patients with obesity, COPD, and insulin-dependent diabetes mellitus are at increased risk for SSI after femoral incisions for peripheral revascularization. A prediction model may assist in identifying patients at high risk for SSI so that targeted risk reduction strategies can be implemented to decrease morbidity and economic costs. Targeted use of CiNPT may help reduce the severity of SSI in these at-risk patients.


Subject(s)
Negative-Pressure Wound Therapy , Pulmonary Disease, Chronic Obstructive , Humans , Negative-Pressure Wound Therapy/adverse effects , Obesity/complications , Pulmonary Disease, Chronic Obstructive/complications , Retrospective Studies , Risk Factors , Surgical Wound Infection , Treatment Outcome
17.
J Vasc Surg ; 76(3): 733-740.e2, 2022 09.
Article in English | MEDLINE | ID: mdl-35278651

ABSTRACT

OBJECTIVE: The Gore Excluder iliac branch endoprosthesis (IBE; W.L. Gore & Associates, Flagstaff, AZ) is the only iliac branch device approved in the United States to preserve blood flow to the external and internal iliac arteries (IIAs). Some surgeons have used the Gore Viabahn VBX balloon expandable endoprosthesis (VBX; W.L. Gore & Associates) in the IIA rather than the self-expanding endograft designed for the IBE, the internal iliac component (IIC). The objective of the present study was to examine the outcomes for patients treated for aortoiliac artery aneurysms using the IBE with either the IIC or VBX stent. METHODS: We performed a retrospective, single-center review of patients treated for aortoiliac artery aneurysms using the Gore IBE device, with either the IIC or VBX stent into the IIA, from February 2016 to March 2021. The patient demographics, procedure details, 30-day morbidity and mortality, and 6-month and 1-year outcomes and mortality were analyzed. The categorical factors are summarized using frequencies and proportions. Continuous measures are summarized as the mean ± standard deviation. A significance level of P = .05 was assumed for all test results. The analyses were performed using SAS software, version 9.4 (SAS Institute, Cary, NC). RESULTS: A total of 62 patients (64 arteries) had undergone elective aortoiliac artery aneurysm repair with the IBE. The IIC was used exclusively in 35 cases (55%) and the VBX in 29 (45%). The patients who had received the VBX had had a higher American Society of Anesthesiologists class (P = .006). Upper extremity access was used for VBX delivery in 24.1% of the procedures. No return to the operating room was required in either group. No differences were found in technical success (IIC, 97.1%; VBX, 93.1%; P = .59), the presence of endoleak on completion (20.0% vs 6.9%; P = .17), readmission (97.1% vs 93.1%; P = .59), or mortality (1.6% vs 0%; P = .45) at 30 days. No differences were found in the requirement for any IBE reintervention after 30 days. No type Ia, Ib, or III endoleaks had occurred in either group at any follow-up point. No significant difference was found in internal iliac limb primary patency (IIC, 100%; VBX, 96.3%) between groups. A nonstatistically significant trend was found toward fewer trunk-ipsilateral leg type II endoleaks in the VBX group during follow-up. CONCLUSIONS: These data suggest that the VBX is a reasonable substitute for the IIC, with a comparable safety and efficacy profile. Given its inherent conformability, greater range of diameters, and longer working length, the VBX stent offers expanded IIA branch options with the IBE.


Subject(s)
Blood Vessel Prosthesis Implantation , Endovascular Procedures , Iliac Aneurysm , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/adverse effects , Endoleak/etiology , Endovascular Procedures/adverse effects , Humans , Iliac Aneurysm/diagnostic imaging , Iliac Aneurysm/etiology , Iliac Aneurysm/surgery , Prosthesis Design , Retrospective Studies , Time Factors , Treatment Outcome , Vascular Patency
18.
Int J Cardiovasc Imaging ; 38(8): 1711-1721, 2022 Aug.
Article in English | MEDLINE | ID: mdl-35195805

ABSTRACT

Ultrasound (US) remains a valuable modality for the assessment of vascular diseases, with conventional sonographic techniques such as grayscale and Doppler US used extensively to assess carotid atherosclerosis and abdominal aortic aneurysms. However, conventional US techniques are inherently limited by factors such as operator dependency and limited field of view. There is an increasing interest in the use of advanced sonographic techniques such as contrast-enhanced US (CEUS) and 3-dimensional (3D) US to mitigate some of these limitations. Clinical applications of advanced sonographic techniques include surveillance of abdominal aortic aneurysm, post-endovascular aortic repair, and carotid atherosclerotic plaques. Recently published studies have demonstrated that CEUS and 3D US are superior to conventional US and comparable to computed tomography for certain vascular applications. Further research is required to fully validate the application of advanced sonographic techniques in evaluating various atherosclerotic diseases.


Subject(s)
Aortic Aneurysm, Abdominal , Atherosclerosis , Humans , Contrast Media , Predictive Value of Tests , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/surgery , Ultrasonography
19.
J Vasc Surg ; 75(6): 1855-1863.e2, 2022 06.
Article in English | MEDLINE | ID: mdl-35074411

ABSTRACT

OBJECTIVE: Racial disparities in cardiovascular risk factors and disease outcomes have been well documented. A knowledge gap exists regarding the role that health maintenance plays in the development and outcomes of type B aortic dissection (TBAD). In the present study, we evaluated the comparative presentation and short-term outcomes of patients with TBAD across race. METHODS: In the present single-center, retrospective study, TBAD patients who had been admitted to the intensive care unit from 2015 to 2020 were identified. Patients who had self-identified as Black (n = 57) or White (n = 123) were included. The demographics, socioeconomic status, and pre-event health maintenance were compared between the two groups. Socioeconomic disadvantage was quantified using the area deprivation index (ADI). Management strategies included nonoperative and surgical repair. The outcomes assessed included 30-day mortality, hospital length of stay, and the APACHE II (acute physiology and chronic health evaluation) score. RESULTS: The present study included 180 consecutive patients with TBAD. TBAD included complicated (n = 42) and uncomplicated (n = 138) cases, of which 79 had had high-risk features. Black patients were younger than were White patients (58.9 vs 67.6 years; P < .01) and were more likely to have end-stage renal disease (8.8% vs 0.8%; P = .01) and to present with anemia (10.5% vs 2.4%; P = .03). The TBAD anatomic features and management were similar in both groups. The rate of surgical intervention during hospitalization was 40% and 46% for the Black and White patients, respectively (P = .4). Black patients were more likely to be taking three or more hypertension agents (42.2% vs 16.4%; P = .005) and were less likely to be adherent to taking the prescribed agents (27.1% vs 6.7%; P < .001). Also, Black patients had fewer primary care physician visits before TBAD (P = .03) and more emergency department usage before TBAD (57.9% vs 26.9%; P < .001). Black patients had also had higher ADI scores (86.0 ± 14.6 vs 64.4 ± 21.3; P < .001). The median APACHE II score was the same for both Black and White patients (9 [interquartile range (IQR), 6-12] and 9 [IQR, 7-13], respectively; P = .7). The median hospital length of stay was identical for both groups (7 days; IQR, 5-13 days). The readmission rate was 24.5% for Black patients vs 15.5% for White patients (P = .16), with the 30-day mortality similar between the two groups (Black, 7.0%; White, 5.7%; P = .7). CONCLUSIONS: Black patients had presented at a younger age but with similar dissection morphology, rate of anatomic high-risk features, and APACHE II scores. The fewer primary care physician visits, greater emergency department usage, and higher ADI scores suggested lower health maintenance for the Black patients. White patients with TBAD were also highly deprived of health maintenance compared with the national percentile, indicating that TBAD is a disease that affects vulnerable populations, regardless of race.


Subject(s)
Aortic Aneurysm, Thoracic , Aortic Dissection , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Aortic Dissection/complications , Aortic Dissection/diagnostic imaging , Aortic Dissection/therapy , Aortic Aneurysm, Thoracic/surgery , Blood Vessel Prosthesis Implantation/adverse effects , Endovascular Procedures/adverse effects , Humans , Retrospective Studies , Risk Factors , Time Factors , Treatment Outcome
20.
J Vasc Surg ; 76(2): 461-465, 2022 08.
Article in English | MEDLINE | ID: mdl-35085749

ABSTRACT

OBJECTIVE: The natural history of isolated common iliac artery aneurysms (CIAAs) has not been well-studied. The optimal size threshold for elective repair of isolated CIAAs is also not well-defined. We sought to determine the natural history and growth rates of isolated CIAAs to justify a surveillance protocol and size for elective repair. METHODS: Isolated CIAAs (>2 cm) identified from January 1, 2008, through February 29, 2020, at a single center were reviewed. Patient demographics, comorbidities, and details of CIAA operative repairs were retrospectively collected. All available duplex ultrasound and computed tomography scans were reviewed from time of CIAA identification through June 2020. RESULTS: There were 244 isolated CIAAs found in 167 patients. The cohort was 94% male with an average age of 68.1 ± 8.8 years at the time of CIAA detection. CIAAs were identified with ultrasound examination 69% of the time with a mean CIAA diameter of 2.3 cm. Operative repair of a CIAA was performed in 11.4% of the cohort at an average diameter of 3.30 ± 1.02 cm. The majority of these repairs were performed via an endovascular approach (73.7%; n = 14). There were no symptomatic or ruptured isolated CIAAs. Concurrent aortic growth that led to an abdominal aortic aneurysm with diameter of at least 3 cm occurred in 10.6% (n = 26) of isolated CIAAs. The average length of time from CIAA diagnosis to repair was 65.7 ± 47.1 months. The overall CIAA growth rate was 0.4 mm/y. A subgroup analysis based on CIAA size demonstrated a growth rate of 0.2 mm/y fore CIAAs 2.00 to 2.49 cm, 0.3 mm/y for CIAAs 2.50 to 2.99cm, and 1.3 mm/y for CIAAs 3.0 cm or larger. There were two CIAAs greater than 3.0 cm with extreme growth, which significantly impacted the CIAA growth rate on sensitivity analysis. After excluding those two CIAAs from the model, the overall CIAA growth rate was 0.3 mm/y. The subgroup analysis then demonstrated a growth rate of 0.2 mm/y for CIAAs 2.00 to 2.49cm, 0.3 mm/y for CIAAs 2.50 to 2.99cm, and 0.5 mm/y for CIAAs 3 cm or larger. CONCLUSIONS: Isolated CIAAs are typically slow growing aneurysms that expectedly grow faster as they enlarge. Given the rare occurrence of rapid isolated CIAA growth, we recommend surveillance at 3 years for 2.00 to 2.49 cm isolated CIAAs, 2 years for 2.50 to 2.99 cm isolated CIAAs, and yearly for isolated CIAAs greater than 3.0 cm. The lack of symptomatic or ruptured isolated CIAAs in this study supports delaying elective repair until an isolated CIAA diameter reaches at least 3.5 cm. These recommendations should be considered for isolated CIAA practice guidelines.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Iliac Aneurysm , Aged , Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/methods , Endovascular Procedures/methods , Female , Humans , Iliac Aneurysm/diagnostic imaging , Iliac Aneurysm/surgery , Iliac Artery/surgery , Male , Middle Aged , Retrospective Studies , Treatment Outcome , Ultrasonography, Doppler, Duplex
SELECTION OF CITATIONS
SEARCH DETAIL
...