Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Neuroradiology ; 52(2): 91-7, 2010 Feb.
Article in English | MEDLINE | ID: mdl-19756565

ABSTRACT

INTRODUCTION: This study seeks to describe the predictive value of the signal intensity ratio (SIR) in magnetic resonance imaging-turbo inversion recovery magnitude (MRI-TIRM) in patients with Graves' orbitopathy (GO) with regard to predictability of therapy response. METHODS: Included in this prospective pilot study were 36 consecutive patients with GO and 25 control subjects. Patients were clinically assessed according to the European Group on Graves' Orbitopathy recommendations with active GO defined by a clinical activity score (CAS) > or = 3. On magnetic resonance (MR) imaging, muscle inflammation was measured with a region of interest set within the brightest extra-ocular muscle both on coronal turbo inversion recovery magnitude (TIRM) and on fat suppressed gadolinium-enhanced T1-weighted sequences. To calculate the SIR, the measured signal intensity was set in proportion to that of the ipsilateral temporalis muscle. RESULTS: Signal intensity ratio in coronal T2-weighted TIRM sequences in either group ranged from 1.22 to 4.92 (mean 2.04) in patients with GO and from 1.18 to 2.4 (mean 1.63) in controls without GO. The observed differences were significant on the TIRM sequences (right eye p = 0.023; left eye p = 0.022), whereas, no significant differences could be detected on the T1-weighted sequences (right eye p = 0.396; left eye p = 0.498). A cut off value of SIR > 2.5 for a CAS > or = 4 to discriminate active from inactive patients was statistically calculated. CONCLUSION: T2 relaxation time is a reliable tool in detecting active GO. The difference in T2-SIR versus T1-SIR is helpful to distinguish inflammatory oedema of the extra ocular muscles from intra-orbital congestion due to reduced venous outflow.


Subject(s)
Graves Ophthalmopathy/diagnosis , Graves Ophthalmopathy/pathology , Magnetic Resonance Imaging/methods , Oculomotor Muscles/pathology , Severity of Illness Index , Adolescent , Adult , Aged , Aged, 80 and over , Contrast Media , Female , Functional Laterality , Gadolinium , Graves Ophthalmopathy/therapy , Humans , Magnetic Resonance Imaging/instrumentation , Male , Middle Aged , Pilot Projects , Prognosis , Prospective Studies , Treatment Outcome , Young Adult
2.
Magn Reson Imaging ; 23(3): 469-74, 2005 Apr.
Article in English | MEDLINE | ID: mdl-15862648

ABSTRACT

The aim of our study was to determine whether T2-weighted (T2w) MRI of the brain could be performed immediately after the administration of gadopentetate dimeglumine (gadolinium DTPA) in patients with multiple sclerosis (MS) without a loss in image quality or diagnostic reliability. Sixteen patients with clinically diagnosed MS were included in the study. Twenty-four patients with various cerebral pathologies (14 patients with multiple lacunar lesions) were examined in order to exclude masking of T2 hyperintense lesions other than MS lesions. Images of 10 patients without pathological changes served as a control condition for the qualitative analysis. In these 50 patients, T1w and T2w MRI was performed before and after the administration of gadolinium DTPA. Signal intensities were measured within T2 hyperintense cerebral lesions, in T1-enhancing lesions and in normal appearing brain tissue on T2w turbo spin-echo (TSE) sequences. Both quantitative and qualitative analysis did not show significant differences between T2w pre- and postcontrast series. T2w MRI performed prior to and after the administration of gadolinium DTPA provides similar information in patients with MS. With a TR of 3.2 s, not a single lesion was obscured on T2w postcontrast series. Acquisition of T2w MR images immediately after the administration of gadolinium DTPA allows for shorter examination time and assures sufficient time for contrast enhancement in cerebral lesions with a disrupted blood-brain barrier.


Subject(s)
Brain/pathology , Contrast Media/administration & dosage , Gadolinium DTPA/administration & dosage , Magnetic Resonance Imaging/methods , Multiple Sclerosis/pathology , Adolescent , Adult , Computer Simulation , Female , History, 18th Century , Humans , Male , Middle Aged , Statistics, Nonparametric
3.
Arch Neurol ; 59(9): 1480-3, 2002 Sep.
Article in English | MEDLINE | ID: mdl-12223037

ABSTRACT

BACKGROUND: Cerebral autosomal dominant arteriopathy with subcortical infarcts and leukoencephalopathy (CADASIL) and primary angiitis of the central nervous system (PACNS) share several clinical and radiological features. However, digital subtraction angiogram (DSA) is generally reported as normal in CADASIL, whereas lumen irregularities in distal cerebral arteries indicate PACNS. OBJECTIVE: To describe a potential pitfall of DSA interpretation, which led to the tentative diagnosis of PACNS in a CADASIL patient. PATIENT AND METHODS: Single case observation. RESULTS: A 47-year-old man sustained recurrent subcortical infarcts. He had mild hypercholesterolemia and migraine. His family history was unremarkable. The underlying cause of stroke could not be elucidated. Transcranial Doppler sonography revealed decreased intracranial blood flow velocities compatible with CADASIL. Lumen irregularities of several peripheral intracranial arteries were seen on DSA, which suggested PACNS. CADASIL was confirmed by results from skin biopsy and genetic testing. CONCLUSIONS: First, in patients with CADASIL, DSA can show segmental lumen irregularities in distal cerebral arteries suggestive of PACNS. Second, the potential role of transcranial Doppler sonography to distinguish CADASIL from PACNS deserves further testing.


Subject(s)
Central Nervous System Diseases/pathology , Dementia, Multi-Infarct/pathology , Vasculitis/pathology , Central Nervous System Diseases/diagnostic imaging , Central Nervous System Vascular Malformations/pathology , Cerebral Angiography , Cerebral Infarction/pathology , Cerebrovascular Circulation , Dementia, Multi-Infarct/diagnostic imaging , Diagnosis, Differential , Humans , Magnetic Resonance Angiography , Male , Middle Aged , Ultrasonography, Doppler, Transcranial , Vasculitis/diagnostic imaging
4.
AJNR Am J Neuroradiol ; 23(1): 121-7, 2002 Jan.
Article in English | MEDLINE | ID: mdl-11827884

ABSTRACT

BACKGROUND AND PURPOSE: In carotid artery stent placement, marked oversizing of the stent relative to the internal carotid artery lumen is common. This study was performed to determine the influence of using oversized self-expanding nitinol stents on neointimal hyperplasia. METHODS: In six greyhound dogs, 24 self-expanding nitinol stents (eight SMART stents, eight Easy Wallstents, eight Sinus-Flex stents) were inserted into both common carotid arteries (CCAs). In each CCA, two stents were deployed; a stent of the appropriate diameter was implanted distally and an oversized stent proximally. After 4 months, transverse sections of each stent were examined histologically and at computerized image analysis. Neointimal hyperplasia was determined as the proportion of the residual diameter of the patent vessel lumen compared with the stent lumen. RESULTS: The amount of neointimal hyperplasia did not differ between the normal-sized and oversized stents. The mean preserved luminal diameter (+/-SEM) with normal- and oversized stents, respectively, were as follows: Easy Wallstent, 94% +/- 1.0 and 96% +/- 1.5; SMART stent, 92% +/- 1.6 and 93% +/- 1.8; and Sinus-Flex stent, 93% +/- 2.7 and 93% +/- 2.6. The mean preserved patent lumen with the 12 normal-sized stents (93% +/-1.0) was not significantly different from that of the 12 oversized stents (94% +/- 1.1, P =.502). CONCLUSION: Under experimental conditions, use of self-expanding stents oversized by 30-40% appeared to result in neointimal hyperplasia comparable to that caused by normal-sized stents. All three stent types appeared to have similarly low neointimal responses.


Subject(s)
Carotid Artery, Internal/pathology , Fibromuscular Dysplasia/pathology , Stents , Tunica Intima/pathology , Animals , Dogs , Equipment Failure Analysis , Image Processing, Computer-Assisted , Prosthesis Design , Prosthesis Fitting
SELECTION OF CITATIONS
SEARCH DETAIL
...