Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
1.
Ann Thorac Surg ; 95(5): 1640-6, 2013 May.
Article in English | MEDLINE | ID: mdl-23562468

ABSTRACT

BACKGROUND: The SynCardia temporary total artificial heart (t-TAH) provides complete circulatory support by replacing both native cardiac ventricles and all cardiac valves. METHODS: We performed a retrospective analysis of demographics, clinical characteristics and survival of patients bridged to transplantation using the SynCardia t-TAH (SynCardia Systems Inc, Tucson, AZ). RESULTS: From 2000 to 2010, the SynCardia t-TAH was implanted in 90 consecutive patients (80 males; mean age, 46 ± 13 years) suffering cardiogenic shock secondary to idiopathic (n = 40, 46%) or ischemic (n = 24, 27%) cardiomyopathy or other causes. Before implantation, 7 (9%) patients had cardiac arrest, 27 (33%) were on ventilator, and 18 (22%) were on extracorporeal life support. Pre-implant creatinine values were 1.7 ± 0.97 mg/dL and total bilirubin levels were 45 ± 32 µmol/L; mean duration of support was 84 ± 102 days. Thirty-five (39%) patients died while on support after a mean of 62 ± 107 days. Actuarial survival on device was 74% ± 5%, 63% ± 6%, and 47% ± 8% at 30, 60, and 180 days after implantation. While on support, 9 (10%) patients suffered stroke, 13 (14%) had mediastinitis, and 35 (39%) required surgical reexploration for bleeding, hematoma, or infection. Multivariate analysis revealed that older recipient age and preoperative mechanical ventilation were risk factors for death while on support. Fifty-five (61%) patients were transplanted after a mean of 97 ± 98 days of support. Actuarial survival rates were 78% ± 6%, 71% ± 6%, and 63% ± 8% at 1, 5, and 8 years after transplantation. CONCLUSIONS: The SynCardia t-TAH provided acceptable survival to transplantation rates with a remarkably low incidence of neurologic events. Posttransplant survival was similar to that of patients undergoing primary heart transplantation in France.


Subject(s)
Heart Transplantation , Heart, Artificial , Adult , Age Factors , Aged , Female , Heart Transplantation/mortality , Humans , Logistic Models , Male , Middle Aged , Respiration, Artificial , Retrospective Studies , Risk Factors
2.
J Thorac Cardiovasc Surg ; 143(4 Suppl): S24-8, 2012 Apr.
Article in English | MEDLINE | ID: mdl-22143097

ABSTRACT

OBJECTIVES: To evaluate a new surgical technique for the correction of anterior mitral leaflet prolapse. METHODS: From October 2006 to November 2011, 44 consecutive patients (28 males, mean age 55 ± 13 years) underwent mitral valve repair because of anterior mitral leaflet prolapse. Echocardiography was performed to evaluate the distance from the tip of each papillary muscle to the annular plane. A specially designed caliper was used to manufacture a parachute-like device, by looping a 4-0 polytetrafluoroethylene suture between a Dacron strip and Teflon felt pledget, according to the preoperative echocardiographic measurements. This parachute was then used to resuspend the anterior mitral leaflet to the corresponding papillary muscle. Of the 44 patients, 35 (80%) required concomitant posterior leaflet repair. Additional procedures were required in 16 patients (36%). The preoperative logistic European System for Cardiac Operative Risk Evaluation was 4.3 ± 6.9. RESULTS: The clinical and echocardiographic follow-up were complete. The total follow-up was 1031 patient-months and averaged 23.4 ± 17.2 months per patient. The overall mortality rate was 4.5% (n = 2). Also, 2 patients (4.5%) with recurrent mitral regurgitation required mitral valve replacement, 1 on the first postoperative day and 1 after 13 months. In the latter patient, histologic analysis showed complete endothelialization of the Dacron strip. At follow-up, all non-reoperated survivors (n = 40) were in New York Heart Association class I, with no regurgitation in 40 patients (93%) and grade 2+ mitral regurgitation in 3 (7%). CONCLUSIONS: This technique offers a simple and reproducible solution for correction of anterior leaflet prolapse. Echocardiography can reliably evaluate the length of the chordae. However, the long-term results must be evaluated and compared with other surgical strategies.


Subject(s)
Heart Valve Prosthesis Implantation , Mitral Valve Annuloplasty , Mitral Valve Prolapse/surgery , Mitral Valve/surgery , Adult , Aged , Chi-Square Distribution , Echocardiography, Transesophageal , Feasibility Studies , Female , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/mortality , Humans , Kaplan-Meier Estimate , Male , Middle Aged , Mitral Valve/diagnostic imaging , Mitral Valve Annuloplasty/adverse effects , Mitral Valve Annuloplasty/mortality , Mitral Valve Insufficiency/etiology , Mitral Valve Insufficiency/surgery , Mitral Valve Prolapse/complications , Mitral Valve Prolapse/diagnostic imaging , Mitral Valve Prolapse/mortality , Paris , Postoperative Complications/etiology , Postoperative Complications/surgery , Predictive Value of Tests , Recurrence , Registries , Reoperation , Retrospective Studies , Risk Assessment , Risk Factors , Time Factors , Treatment Outcome
4.
Ann Thorac Surg ; 88(2): 491-7, 2009 Aug.
Article in English | MEDLINE | ID: mdl-19632399

ABSTRACT

BACKGROUND: Management of octogenarian patients with acute type A acute aortic dissection is controversial. This study analyzed the surgical outcomes to identify patients who should undergo operations. METHODS: Beginning January 2000, we established a registry including all octogenarian patients operated on for type A acute aortic dissection. We evaluated 57 consecutive patients enrolled up to December 2006. Their median age was 82 (range, 80 to 89 years). Compassionate indication operations were attempted in 2 moribund patients and in 5 presenting with shock associated with neurologic symptoms or renal failure, or both. Operations followed the standard procedure recommended in younger patients. Follow-up was 100% complete (mean, 3.9 +/- 2 years; range, 5 months to 8 years). RESULTS: There were 26 (45.6%) in-hospital and 6 late deaths. Multivariate analysis identified compassionate indication (p < or = 0.0001) and total arch replacement (p = 0.0060) as risk factors for in-hospital mortality. Postoperative complications occurred in 36 patients (69.2%) and were associated with a higher mortality (p = 0.0001). Overall survival was 51% at 1 year and 44% at 5 years. Excluding patients with compassionate indication and those who underwent total arch replacement, or both, overall survival was 66% at 1 year and 57% at 5 years. CONCLUSIONS: Surgical treatment for type A acute aortic dissection in octogenarians shows satisfactory midterm results among survivors. However, the high mortality rate imposes a requirement for better perioperative management. Compassionate cases should be managed medically. A less aggressive approach should improve outcomes of surgical treatment.


Subject(s)
Aortic Aneurysm/mortality , Aortic Dissection/mortality , Aged, 80 and over , Aortic Dissection/surgery , Aortic Aneurysm/surgery , Female , Heart Failure/mortality , Hospital Mortality , Humans , Length of Stay , Male , Multivariate Analysis , Postoperative Complications/epidemiology , Prognosis , Registries , Risk Factors , Treatment Outcome
5.
Ann Thorac Surg ; 87(6): 1789-94, 2009 Jun.
Article in English | MEDLINE | ID: mdl-19463596

ABSTRACT

BACKGROUND: The present study was undertaken to evaluate clinical, hemodynamic, and morphologic results of composite stentless xenograft with polyethylene terephthalate fiber (Dacron; DuPont, Wilmington, DE) graft extension for combined replacement of the aortic valve, root, and ascending aorta. METHODS: Between 1997 and 2008, 55 consecutive patients (33 men, 71 +/- 11 years) underwent ascending aortic replacement using Medtronic Freestyle with Dacron graft extension (DuPont). Indications included aneurysm (n = 31, 56%), dissection (n = 16, 29%), and endocarditis (n = 8, 15%). Associated procedures were performed in 25 patients (46%). Preoperative logistic EuroSCORE averaged 34% +/- 28%. Mean cardiopulmonary bypass and aortic cross-clamp times were 244 +/- 134 minutes and 162 +/- 69 minutes, respectively. RESULTS: Clinical follow-up was 100% complete and averaged 2 +/- 3 years. Early mortality was 0% (n = 0) in patients with a preoperative EuroSCORE of less than 20 (n = 26, mean expected mortality, 13% +/- 5%) and 31% (n = 9) in those with preoperative logistic EuroSCORE of at least 20 (n = 29, mean expected mortality, 52% +/- 28%). One- and 3-year survival rates were 83% +/- 5% and 78% +/- 7%, respectively. No major thromboembolic or spontaneous bleeding events were recorded. One patient (2%) required late reoperation for prosthetic valve endocarditis. Echocardiographic follow-up showed no valve dysfunction and low mean transvalvular gradients (7 +/- 5 mm Hg). A 64-channel computed tomographic scan was performed in 33 patients at 32.4 +/- 34 months and revealed two small pseudoaneurysms in a single patient. CONCLUSIONS: Composite Freestyle with Dacron graft extension appears to be a safe option for bioprosthetic replacement of the aortic root and tubular ascending aorta. However, long-term results using this composite graft will have to be determined.


Subject(s)
Aorta/surgery , Blood Vessel Prosthesis , Polyethylene Terephthalates , Aged , Blood Vessel Prosthesis/adverse effects , Cohort Studies , Female , Humans , Male , Polyethylene Terephthalates/adverse effects , Postoperative Complications/epidemiology , Retrospective Studies
6.
J Heart Lung Transplant ; 28(2): 199-201, 2009 Feb.
Article in English | MEDLINE | ID: mdl-19201348

ABSTRACT

Owing to the actual increase of mechanical circulatory support durations, total or partial replacement of ventricular assist devices (VADs) will most certainly have to be performed with increasing frequency. Herein we report the case of a patient in whom an INCOR (Berlin Heart AG, Berlin) implantable axial-flow pump was replaced without the use of cardiopulmonary bypass (CPB), underscoring some of the unique features provided by this system.


Subject(s)
Infusion Pumps, Implantable , Myocardial Ischemia/surgery , Ventricular Dysfunction, Left/drug therapy , Anticoagulants/administration & dosage , Anticoagulants/therapeutic use , Aspirin/therapeutic use , Clopidogrel , Equipment Design , Heart-Assist Devices , Humans , International Normalized Ratio , Male , Middle Aged , Myocardial Ischemia/complications , Platelet Aggregation Inhibitors/therapeutic use , Ticlopidine/analogs & derivatives , Ticlopidine/therapeutic use , Treatment Outcome , Ventricular Dysfunction, Left/etiology , Ventricular Dysfunction, Left/surgery , Warfarin/administration & dosage , Warfarin/therapeutic use
7.
Eur J Cardiothorac Surg ; 35(1): 77-82, 2009 Jan.
Article in English | MEDLINE | ID: mdl-18952452

ABSTRACT

Increasing patient age and improved durability of latest generation bioprostheses have stimulated the use of bioprosthetic devices in the setting of ascending aortic replacement as an alternative to mechanical valved conduits or aortic valve-sparing procedures. We performed an English literature review to assess different surgical options that have been described for bioprosthetic replacement of the ascending aorta. Reported options include: (1) composite valved conduits using a stented bioprosthesis; (2) composite valved conduits using a stentless bioprosthesis; (3) total xenopericardial valved conduits. Composite valved grafts using stented bioprostheses offer a safe and durable option for bioprosthetic replacement of the ascending aorta. Other options are of more recent use and await medium-term results.


Subject(s)
Aorta/surgery , Aortic Valve/surgery , Bioprosthesis , Blood Vessel Prosthesis Implantation/methods , Heart Valve Prosthesis Implantation/methods , Blood Vessel Prosthesis , Heart Valve Prosthesis , Humans , Stents
8.
Presse Med ; 38(7-8): 1076-88, 2009.
Article in French | MEDLINE | ID: mdl-19070988

ABSTRACT

BACKGROUND: The majority of ascending aortic aneurysms cannot be related to any specific etiology and should be qualified as idiopathic. The incidence of this disease is increasing in the population of the developed countries but its pathobiology is poorly understood. AIM: This article is reviewing the publications concerning the pathobiology of idiopathic ascending aortic aneurysms. SOURCES: A PubMed search on articles published in English or French, between January 1965 and December 2007, on key-words << aortic root >>, << ascending aorta >>, << aortic arch >>, << thoracic aorta >>, << aneurysm >>, << dilatation >> and << dissection >> was undertaken. Articles on aneurysms related to inflammatory and infectious diseases, congenital or genetic syndromes were excluded. RESULTS: The presented data suggests that destructive remodeling of the aortic wall, inflammation and angiogenesis, biomechanical wall stress, and molecular genetics are relevant mechanisms of idiopathic ascending aortic aneurysm formation and progression. LIMITS: Sparse data available from few direct studies offer limited knowledge on pathobiology of idiopathic ascending aortic aneurysms. CONCLUSION: A more intimate knowledge of the triggers and perpetrating factors of this disease might offer new diagnostic and treatment options.


Subject(s)
Aorta/physiopathology , Aortic Aneurysm, Thoracic/physiopathology , Aorta/metabolism , Aortic Aneurysm, Thoracic/etiology , Aortic Aneurysm, Thoracic/metabolism , Aortic Rupture/epidemiology , Collagen/metabolism , Elastic Tissue/metabolism , Genotype , Glycosaminoglycans/metabolism , Humans , Immunoblotting , Matrix Metalloproteinase 1/metabolism , Matrix Metalloproteinase 13/metabolism , Matrix Metalloproteinase 7/metabolism , Matrix Metalloproteinase 9/metabolism , Oligonucleotide Array Sequence Analysis , Point Mutation/genetics
9.
Eur J Cardiothorac Surg ; 33(3): 418-23, 2008 Mar.
Article in English | MEDLINE | ID: mdl-18162404

ABSTRACT

BACKGROUND: Heart transplantation in patients supported with ventricular assist devices (VADs) entails a high risk of injury at resternotomy. Prior femorofemoral bypass is the preferred approach in these patients, but poor venous drainage may restrict arterial flow rate. PATIENTS AND METHODS: We compared bypass parameters, transfusion requirements and postoperative outcome in 33 consecutive patients (40.4+/-12.2 years old, 28 men) assisted with the Thoratec paracorporeal VAD (mean duration, 3.0+/-2.96 months) undergoing transplantation using either gravity siphon drainage (GSD, n=16) or kinetic assisted venous drainage (KAVD, n=17). RESULTS: Cannulation technique, perfusion pressure, temperature and duration were similar between groups. There were no significant differences in arterial re-infusion flow rates (GSD, 3.6+/-0.7 vs KAVD, 3.8+/-0.6l/min, p=0.5). KAVD patients had a lower mean S(v)O(2) and a higher desaturation index than GSD patients (69.5+/-4.6 vs 76.1+/-5.4mmHg, p=0.004; and 0.63+/-0.23 vs 0.25+/-0.63, p=0.0001, respectively). Perioperative requirements in fresh frozen plasma and platelet transfusions were significantly higher in KAVD patients. However, there were no differences in postoperative patient outcome. CONCLUSION: Perceived benefits on venous return associated with KAVD do not necessarily translate into improved arterial re-infusion flow rates and should be weighed against the hazards of increased venous air aspiration and blood product requirements.


Subject(s)
Cardiopulmonary Bypass/methods , Heart Failure/surgery , Heart Transplantation/methods , Heart-Assist Devices/standards , Adolescent , Adult , Arteries/physiology , Drainage/methods , Erythrocyte Count , Female , Heart Failure/physiopathology , Humans , Kinetics , Male , Middle Aged , Regional Blood Flow , Reoperation/adverse effects , Sternum/surgery , Young Adult
10.
Eur Heart J ; 28(21): 2620-6, 2007 Nov.
Article in English | MEDLINE | ID: mdl-17901082

ABSTRACT

AIMS: To assess the prognostic impact of prosthesis-patient mismatch (PPM) in a large consecutive series of patients operated for low-gradient aortic stenosis (AS). METHODS AND RESULTS: Outcomes after surgery for low-gradient AS were prospectively assessed in 152 consecutive patients from seven institutions. There were 113 men (74%); mean age was 72 years (64-76); valve area, 0.7 cm(2) (0.6-0.8); left ventricular (LV) ejection fraction 0.31 (0.25-0.37) and baseline mean transaortic pressure gradient (MPG), 30 mmHg (25-35) Among 139 patients with available prosthetic valve effective orifice area (EOA), PPM (defined by an indexed EOA < or = 0.85 cm(2)/m(2)) was present in 79 patients (57%) and had no significant impact on post-operative mortality. Independent predictors of overall mortality were LV contractile reserve [hazard ratio (HR) 0.52; 95% confidence interval (CI) 0.35-0.78; P = 0.002], associated coronary artery bypass grafting (HR 1.87; 95% CI 1.24-2.82; P =0.003), baseline MPG (per 1 mmHg decrease to 10 mmHg; HR 1.03; 95% CI 1.01-1.06; P = 0.021), previous cancer (HR 2.13; 95% CI 1.05-4.29; P = 0.037), and logistic EuroSCORE (per 1% increase; HR 1.02; 95% CI 1.01-1.04; P = 0.040). CONCLUSION In this large multicentre series of patients with low-gradient AS, we found that PPM (moderate in most cases) had no influence on post-operative mortality. Therefore, the performance of more complex interventions in order to avoid moderate PPM may not be justified in the setting of low-gradient AS, because their higher risk probably outweighs the expected benefit.


Subject(s)
Aortic Valve Stenosis/pathology , Aortic Valve/pathology , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis/adverse effects , Prosthesis Failure , Aged , Aortic Valve/surgery , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/surgery , Epidemiologic Methods , Female , Humans , Male , Middle Aged , Organ Size , Prosthesis Fitting
11.
J Heart Valve Dis ; 14(3): 433-9, 2005 May.
Article in English | MEDLINE | ID: mdl-15974539

ABSTRACT

BACKGROUND AND AIM OF THE STUDY: The Medtronic Mosaic valve (MMV) is a latest generation supra-annular stented porcine valve, which combines a low-profile stent, leaflet fixation at zero pressure in a predilated aortic root, and amino-oleic acid anti-mineralization treatment for improved hemodynamics and durability. A study was conducted to evaluate the clinical and hemodynamic performances of the MMV in patients with a small aortic root (19 mm aortic annulus). METHODS: Between 1998 and 2004, 81 consecutive patients (69 females, 12 males; mean age 78.0 +/- 5.5 years) underwent aortic valve replacement using the 19-mm MMV. Concomitant coronary artery bypass grafting was performed in 28 patients (29.2%), and mitral valve surgery in one patient (1.2%). RESULTS: The 30-day mortality rate was 9.9% (eight deaths). Postoperative actuarial survival estimates were 90.1 +/- 3.3%, 78.5 +/- 4.6% and 69.1 +/- 5.5% at one month, one year and two years, respectively. After a mean follow up of 2.7 +/- 1.9 years, no cases of structural dysfunction, non-structural dysfunction or valve thrombosis were noted. Four ischemic cerebral complications (2.0% per patient-year (pt-yr)), five bleeding complications (2.0%/pt-yr) and two prosthetic valve infections (1.0%/pt-yr) were observed. No reoperation on a MMV was performed. Postoperatively, the mean systolic gradient was 23.4 +/- 7.0 mmHg, and the effective orifice area (EOA) 1.06 +/- 0.33 cm2. Valve prosthesis-patient mismatch (VP-PM) was moderate (indexed EOA > 0.65 cm2/m2 and < or = 0.85 cm2/m2) in 40 patients (49.4%), and severe (indexed EOA < or = 0.65 cm2/m2) in 41 (50.6%). CONCLUSION: Although providing acceptable clinical results, implantation of the 19-mm MMV resulted in a high incidence of postoperative VP-PM. Hence, this valve should be reserved for patients in whom the projected indexed EOA calculated preoperatively is deemed acceptable, given the patient's clinical condition.


Subject(s)
Aortic Valve , Bioprosthesis , Heart Valve Prosthesis , Aged , Aged, 80 and over , Aortic Valve Insufficiency/surgery , Aortic Valve Stenosis/surgery , Brain Ischemia/etiology , Endocarditis, Bacterial/etiology , Female , Follow-Up Studies , Heart Valve Prosthesis Implantation , Humans , Male , Middle Aged , Patient Selection , Postoperative Complications , Postoperative Hemorrhage/etiology , Prosthesis Design , Prosthesis-Related Infections/etiology , Survival Rate , Ventricular Pressure/physiology
SELECTION OF CITATIONS
SEARCH DETAIL
...