Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
1.
Arch Orthop Trauma Surg ; 144(5): 2267-2271, 2024 May.
Article in English | MEDLINE | ID: mdl-38587669

ABSTRACT

The symmetry of the flexion and extension gap influences the functional and long-term outcome after total knee arthroplasty (TKA). Most surgeons check it by applying varus and valgus stress using spacers. This technique has limited accuracy and could be easily extended by rotational movement of the spacer. The objective was to determine the detection threshold and interobserver reliability of this technique. In an in vitro setting with a human cadaveric knee, gap asymmetries were simulated by different medially and laterally applied forces. Using an optical measurement system, the pivot point of the spacer was calculated as a function of the gap symmetry in the first part of the experiment. In the second part, the detection threshold and interobserver reliability of 4 surgeons were determined. For this purpose, gap asymmetries were adjusted to between 0 and 120N in a blinded trial. With a symmetrical gap, the centre of rotation of the spacer was located in the centre of the tibia. With increasing gap asymmetry, the centre of rotation of the spacer shifted to the tight side. This shift was approximately linearly dependent on the force difference. A perfectly balanced gap was detected by the examiners in 50% of the cases. From a force difference of 40N, all examiners identified the gap asymmetry in all cases (ICC = 1.0). The method of spacer rotation described is suitable for reliably detecting gap differences at ≥ 40N, independently of the examiner.


Subject(s)
Arthroplasty, Replacement, Knee , Cadaver , Humans , Arthroplasty, Replacement, Knee/methods , Rotation , Knee Prosthesis , Range of Motion, Articular , Knee Joint/surgery , Knee Joint/physiology , Knee Joint/physiopathology , Biomechanical Phenomena , Observer Variation
2.
J Pers Med ; 14(3)2024 Feb 29.
Article in English | MEDLINE | ID: mdl-38541006

ABSTRACT

Empyema of the joint is an orthopedic emergency that is associated with a prolonged healing process despite adequate surgical and medical therapy. The risk of developing postinfectious osteoarthritis (OA) after successfully treated joint empyema is unknown. Both incidence and risk factors are important for prognostication and would therefore be clinically relevant for the selection of an adequate infectious therapy as well as for the individual follow-up of patients. The aim of this retrospective clinical study was to describe the risk of secondary OA after empyema based on knee and shoulder joint infections after successful primary infection treatment and its risk factors. Thirty-two patients were examined clinically and radiographically after completion of treatment for primary empyema of the knee or shoulder joint. Patients with previous surgery or injections in the affected joint were excluded from the study. The cumulative incidence of new-onset radiographic OA was 28.6%, representing a 5.5-fold increased risk of developing OA compared to the normal population. A figure of 25% of patients underwent total knee arthroplasty after knee empyema. Identified risk factors for primary empyema were obesity, hyperuricemia, and rheumatoid arthritis. Only about 60% of the patients tested positive for bacteria. Staphylococcus aureus, the most common pathogen causing joint empyema, was present in approximately 40% of cases. Secondary osteoarthritis, as a possible secondary disease after joint empyema, could be demonstrated and several risk factors for the primary empyema were identified.

3.
Knee Surg Sports Traumatol Arthrosc ; 32(5): 1199-1206, 2024 May.
Article in English | MEDLINE | ID: mdl-38511851

ABSTRACT

PURPOSE: The purpose of this study was to find out whether the torsions of the femur and tibia are dependent on the coronal plane alignment of the knee (CPAK) type. METHODS: Five hundred patients (1000 legs) were included, who received a whole leg standing three-dimensional (3D) radiograph using EOS imaging (EOS Imaging, Paris, France). SterEOS software was used for digital reconstruction. Femoral and tibial torsions were determined by analysing 3D reconstructions of each leg. Femoral torsion was defined as the angle between the femoral neck axis (FNA) and the posterior condylar axis (PCA). Tibial torsion was defined as the angle between the axis tangent to the posterior part of the tibia plateau and the transmalleolar axis. Arithmetic hip-knee-ankle angle (aHKA) and joint-line obliquity (JLO) were also determined, allowing each leg to be assigned one of nine possible phenotypes according to CPAK. RESULTS: The mean femoral torsion in CPAK type 1 was significantly higher (+ 2.6° ± 0.8°) than in CPAK type 4 (p = 0.02). All other CPAK types did not differ in the degree of femoral torsions. No differences could be demonstrated for the tibial torsion. CONCLUSION: There is a correlation between the coronal alignment of the lower limb and femoral torsion. This may provide the basis for extending the CPAK classification beyond the coronal plane. LEVEL OF EVIDENCE: Level III.


Subject(s)
Femur , Imaging, Three-Dimensional , Knee Joint , Tibia , Humans , Femur/diagnostic imaging , Femur/anatomy & histology , Female , Male , Adult , Knee Joint/diagnostic imaging , Middle Aged , Tibia/diagnostic imaging , Aged , Torsion Abnormality/diagnostic imaging , Young Adult , Radiography , Adolescent
4.
Trials ; 25(1): 27, 2024 Jan 05.
Article in English | MEDLINE | ID: mdl-38183062

ABSTRACT

BACKGROUND: The gliding surface of total knee endoprostheses is exposed to high loads due to patient weight and activity. These implant components are typically manufactured from ultra-high molecular weight polyethylene (UHMWPE). Crosslinking of UHMWPE by ionizing radiation results in higher wear resistance but induces the formation of free radicals which impair mechanical properties after contact with oxygen. Medium-crosslinked UHMWPE enriched with vitamin E (MXE) provides a balance between the parameters for a sustainable gliding surface, i.e., mechanical strength, wear resistance, particle size, and oxidation stability. Therefore, a gliding surface for knee endoprostheses made up from this material was developed, certified, and launched. The aim of this study is to compare this new gliding surface to the established predecessor in a non-inferiority design. METHODS: This multicenter, binational randomized controlled trial will enroll patients with knee osteoarthritis eligible for knee arthroplasty with the index device. Patients will be treated with a knee endoprosthesis with either MXE or a standard gliding surface. Patients will be blinded regarding their treatment. After implantation of the devices, patients will be followed up for 10 years. Besides clinical and patient-related outcomes, radiological data will be collected. In case of revision, the gliding surface will be analyzed biomechanically and regarding the oxidative profile. DISCUSSION: The comparison between MXE and the standard gliding surface in this study will provide clinical data to confirm preceding biomechanical results in vivo. It is assumed that material-related differences will be identified, i.e., that the new material will be less sensitive to wear and creep. This may become obvious in biomechanical analyses of retrieved implants from revised patients and in radiologic analyses. TRIAL REGISTRATION: ClinicalTrials.gov, NCT04618016. Registered 27 October 2020, https://clinicaltrials.gov/study/NCT04618016?term=vikep&checkSpell=false&rank=1 . All items from the World Health Organization Trial Registration Data Set can be found in Additional file 1.


Subject(s)
Arthroplasty, Replacement, Knee , Polyethylene , Humans , Arthroplasty, Replacement, Knee/adverse effects , Knee Joint , Oxidation-Reduction , Randomized Controlled Trials as Topic , Multicenter Studies as Topic
5.
J Clin Med ; 12(22)2023 Nov 18.
Article in English | MEDLINE | ID: mdl-38002775

ABSTRACT

BACKGROUND: The number of total knee replacements performed annually is steadily increasing. Parallel options for postoperative care are decreasing, which reduces patient satisfaction. External devices to support physical rehabilitation and health monitoring will improve patient satisfaction and postoperative care. METHODS: In a prospective, international multicenter study, patients were asked to use an external motion sensor and a smartphone application during the postoperative course of primary total knee arthroplasty. The collected data were transferred to a data platform, allowing for the real-time evaluation of patient data. RESULTS: In three participating centers, 98 patients were included. The general acceptance of using the sensor and app was high, with an overall compliance in study participation rate of up to 76%. The early results showed a significant improvement in the overall quality of life (p < 0.001) and significant reductions in pain (p < 0.01) and depression (p < 0.001). CONCLUSIONS: The early results of this clinical and multicenter study emphasize that there is a high interest in and acceptance of digital solutions in patients' treatment pathways. Motion sensor and smartphone applications support patients in early rehabilitation.

6.
Medicina (Kaunas) ; 58(6)2022 May 24.
Article in English | MEDLINE | ID: mdl-35743959

ABSTRACT

Background and Objectives: No gold standard exists for treating persistent periprosthetic knee infections. Knee arthrodesis represents one treatment concept for extensive bone defects and extensor system insufficiencies. It has already been shown that knee arthrodesis leads to a significant reduction in one's quality of life. The aim of this survey was to assess the influence of knee arthrodesis on the neighboring joints on the basis of gait analysis data. Our hypothesis is that the hip and ankle joints are negatively influenced by knee arthrodesis in the process of walking. Materials and methods: We performed six pedobarographic and four gait analytical measurements in six patients 2.4 ± 1.6 years after receiving knee arthrodesis at the operating ages of 69.1 ± 9.2 years. Gait analysis consisted of time-distance parameters/minute (number of steps, double support, cycle time, standing phase, step length, gait speed). A healthy group of test subjects (n = 52) was included as the control cohort. Gait analysis was conducted using a three-dimensional movement system and three force-measuring platforms to determine the ground reaction force. Foot pressure was measured using a pedography platform. Results: Five of six patients presented an incomplete rolling movement over the toes on the side that was operated on, presenting with a gait line ending in the forefoot area. All of the patients bore less weight on the side that was operated on. Three of six patients demonstrated a pathological gait line with a healthy opposite side ending in the forefoot area. All of the patients exhibited a reduction in gait speed and step length and a lower number of steps. All of the patients had a prolonged double support/cycle time. Conclusions: Isolated knee arthrodesis is associated with reduced forefoot repulsion, restricted movement on the side receiving the operation, and reduced movement in the ankle/knee joint. The hip showed norm deviations in the hip moment/angle. Knee arthrodesis causes reduced gait kinetics/kinematics. Our survey shows that the relative joint moments of the ankle joint and hip are often reduced. The ankle joint is more affected compared to the hip.


Subject(s)
Ankle Joint , Ankle , Aged , Ankle Joint/surgery , Arthrodesis/methods , Biomechanical Phenomena , Gait , Hip Joint , Humans , Knee Joint/surgery , Middle Aged , Quality of Life , Range of Motion, Articular
7.
J Knee Surg ; 35(6): 645-652, 2022 May.
Article in English | MEDLINE | ID: mdl-32906158

ABSTRACT

Persistent periprosthetic infection following total knee arthroplasty is one of the most dreaded complications of orthopaedic surgery. Treatment strategies include arthrodesis of the knee joint, stable fistula, long-lasting antibiotic therapy, or above-knee amputation. The advantage of amputation in comparison to other treatment options is the possible cure of infection, because the source of infection is removed and no foreign material left in situ. The aim of the study is to examine whether a septic amputation of the femur in case of persistent periprosthetic infection at the knee joint leads to the healing of the patient. Moreover, the physical and mental state should be evaluated. All patients with above-knee amputation because of periprosthetic joint infection after primary total knee arthroplasty between 2016 and 2018 were included in this retrospective study. A questionnaire with the clinical scores visual analog scale, modified Lysholm, Western Ontario and McMaster Universities Osteoarthritis Index and 36-Item Short Form Survey has been designed. In addition, all characteristics and perioperative data were documented. Eleven patients were included in the study. One patient died after above-knee amputation; all other patients live with a marked impairment of quality of life but with absence of the infection of the leg. Two out of ten are able to walk regularly with an exoprosthesis with forearm crutches, 50% are in a wheelchair, while 30% are bedridden. Patients with above-knee amputation after persistent periprosthetic infections were free of infection and without signs of inflammation. However, this is associated with worse mobility and high mortality rate.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Prosthesis-Related Infections , Amputation, Surgical/adverse effects , Arthroplasty, Replacement, Knee/adverse effects , Humans , Knee Prosthesis/adverse effects , Prosthesis-Related Infections/diagnosis , Prosthesis-Related Infections/etiology , Prosthesis-Related Infections/surgery , Quality of Life , Reoperation , Retrospective Studies , Treatment Outcome
8.
Sci Rep ; 10(1): 13053, 2020 08 03.
Article in English | MEDLINE | ID: mdl-32747743

ABSTRACT

Locally applied vancomycin is increasingly being used in primary hip and knee arthroplasty to reduce the risk of infection. Despite encouraging initial results, considerable debate remains on the basis of the data currently available. In particular, it has been unclear up to now whether local vancomycin is suitable to further reduce the risk of infection even if the rate of infection is already low (< 1%). In this monocentric retrospective cohort study, all primary total hip and knee arthroplasties performed between 2013 and 2018 were included. After a change in procedure at the hospital, 1 g vancomycin powder was applied intraarticularly before wound closure. The remaining perioperative procedure was constant over the investigation period. The follow-up was one year. The presence of an infection according to the currently valid MSIS criteria was defined as the endpoint. In patients with TKA two infections (0.3%) were observed under vancomycin prophylaxis in contrast to 44 infections (1.3%) in the control group (p = 0.033). In patients with THA two infections (0.5%) were observed under vancomycin prophylaxis and 48 infections (1.1%) in the control group without local vancomycin but this difference was statistically not significant. No wound complications requiring revision were observed as a result of the vancomycin. On the basis of the results of this study, intraarticular application of vancomycin powder in total hip and knee arthroplasty may be considered. Prospective randomized studies have to confirm this promising results prior a common recommendation.Level of Evidence III Retrospective cohort study.


Subject(s)
Arthroplasty, Replacement, Knee/adverse effects , Prosthesis-Related Infections/drug therapy , Prosthesis-Related Infections/etiology , Vancomycin/administration & dosage , Vancomycin/therapeutic use , Arthroplasty, Replacement, Hip/adverse effects , Bacteria/drug effects , Bacteria/growth & development , Body Mass Index , Case-Control Studies , Humans , Injections, Intra-Articular , Powders , Prosthesis-Related Infections/microbiology , Vancomycin/pharmacology
9.
J Orthop ; 20: 1-5, 2020.
Article in English | MEDLINE | ID: mdl-32021047

ABSTRACT

The aim of this study was to examine toxic effects of tranexamic acid (TXA) on the viability of human chondrocytes. Our hypothesis was that TXA damages human chondrocytes. Chondrocytes were cultured from donated human knee joints. TXA was added to these cultures. Toxicity were analyzed by using LDH und XTT Elisa assays, light microscopy and fluorescence microscopy. The results show that TXA damages human chondrocytes in vitro. We cannot recommend the use of TXA in hemiarthroplasty of the hip or unicompartmental knee arthroplasty in higher concentrations.

10.
Knee Surg Sports Traumatol Arthrosc ; 27(5): 1665-1670, 2019 May.
Article in English | MEDLINE | ID: mdl-30456570

ABSTRACT

PURPOSE: The optimal degree of constraint of a total knee arthroplasty for treatment of knee osteoarthritis with ligamentous laxity is under debate. While varus valgus constrained knees require a minimum level of ligamentous stability, rotating hinge knees can even be implanted if the collateral ligaments have been lost completely. It seems plausible that joint kinematics are determined by implant design in rotating hinge knees, whereas varus valgus constrained knees may be influenced by remaining stabilizers. This may result in more predictable clinical results of hinge knees. The hypothesis of the present study, therefore, was that stability and clinical outcome are better after total knee arthroplasty using rotating hinge knees than after using varus valgus constrained knees. METHODS: All patients who were treated using a mobile-bearing varus valgus constrained knee or a rotating hinge knee for treatment of end-stage osteoarthritis and ligamentous laxity were included. At follow-up, clinical scores were determined (WOMAC, VAS, KSS, FJS, Lysholm). Furthermore, body mass index, operating time, and postoperative complications were documented. Whole leg radiographs as well as patella axial radiographs were analyzed for implant alignment and patella tracking. RESULTS: Eighty-five patients were included in this retrospective study. Both groups showed an average range of motion of 113°. No significant difference between the two groups was observed for any of the scores recorded. In the rotating hinge knee group, a more precise tibia positioning in relation to the mechanical axis but also a significant lateralisation and tilting of the patella were seen, compared with the varus valgus constrained knee group. CONCLUSIONS: Rotating hinge knees did not perform better than mobile-bearing varus valgus constrained knees clinically. Both prosthesis types showed equally good clinical outcomes with regard to stability, mobility, satisfaction, pain and operating time. LEVEL OF EVIDENCE: Retrospective case series, Level IV.


Subject(s)
Arthroplasty, Replacement, Knee/methods , Joint Instability/surgery , Knee Joint/surgery , Knee Prosthesis , Osteoarthritis, Knee/surgery , Adult , Aged , Biomechanical Phenomena , Collateral Ligaments/surgery , Female , Humans , Joint Instability/diagnostic imaging , Knee Joint/diagnostic imaging , Male , Middle Aged , Osteoarthritis, Knee/diagnostic imaging , Pain/surgery , Patella/surgery , Postoperative Complications/etiology , Radiography , Range of Motion, Articular , Retrospective Studies , Tibia/surgery
11.
Arch Orthop Trauma Surg ; 138(5): 711-717, 2018 May.
Article in English | MEDLINE | ID: mdl-29392391

ABSTRACT

Up till now, only a weak connection could be shown between patient-related outcome measures (PROMs) and measurements obtained by gait analysis (e.g. speed, step length, cadence, ground reaction force, joint moments and ranges of motion) after total knee arthroplasty (TKA). This may result from the methodical problem that regression analyses are performed using data that are not normalized against a healthy population. It does appear reasonable to assume that patients presenting a physiological gait pattern are content with their joint. The more the gait parameters differ from a normal gait pattern the worse the clinical outcome measured by PROMs should be expected to be. In this retrospective study, 40 patients were enrolled who had received a gait analysis after TKA, and whose PROMs had been evaluated. A gender- and age-matched control group was formed out of a group of test persons who had already undergone gait analysis. Gait analysis was undertaken using the motion analysis system 3D Vicon with ten infrared cameras and three strength measuring force plates. The physiological gait analysis parameters were deduced from arithmetic mean values taken from all control patients. The deviances of the operated patients' gait analysis parameters from the arithmetic mean values were squared. From these values, the Pearson correlation coefficients for different PROMs were then calculated, and regression analyses were performed to elucidate the correlation between the different PROMs and gait parameters. In the regression analysis, the normalized cadence, relative gait speed of the non-operated side, and range of the relative knee moment of the operated side could be identified as factors which influence the Forgotten Joint Score (FJS-12). The explanation model showed an increase of the FJS-12 with minimisation of these normalized values corresponding to an approximation of the gait pattern seen in the healthy control group. The connection was strong, having a correlation coefficient of 0.708. A physiological gait pattern after TKA results in better PROMs, especially the FJS-12, than a non-physiological gait pattern does.


Subject(s)
Arthroplasty, Replacement, Knee/statistics & numerical data , Gait/physiology , Patient Reported Outcome Measures , Humans , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...