Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
J Prosthodont ; 29(1): 62-68, 2020 Jan.
Article in English | MEDLINE | ID: mdl-30624832

ABSTRACT

PURPOSE: Various resin cements and priming agents are available for adhesive luting of zirconia restorations. The purpose of this study was to investigate how cement type and priming protocol affect the shear bond strength on zirconia ceramics. MATERIALS AND METHODS: Yttria-stabilized tetragonal zirconia polycrystalline ceramic cylinders were bonded to flat zirconia ceramic surfaces using 7 commercially available resin cements. Ten specimens of each cement group were pretreated with a universal primer, and 10 specimens per group were bonded without pretreatment. In addition, 10 specimens per group were pretreated with system-specific zirconia primers, which were available for 3 cements. Altogether, 170 bonded specimens were water-stored, thermal-cycled, and then submitted to shear bond strength tests. The shear bond strength and the fracture types were documented. Differences in shear bond strengths were assessed using 2-way ANOVA with post-hoc test (α = 0.05). A point-biserial correlation was run between the fracture patterns and the shear bond strengths. RESULTS: The mean shear bond strengths of cements in the unprimed group showed large variations between 2.52 ± 3.01 (mean ± SD) MPa and 33.15 ± 7.35 MPa. Pretreating the specimens with a universal primer improved the shear bond strengths significantly in all groups (p < 0.05) with a range of 21.80 ± 12.51 to 57.20 ± 11.40 MPa. The system-specific primers also improved the shear bond strength significantly, compared to the unprimed group (p < 0.01); however, only one system-specific primer achieved a shear bond strength superior to the universal primer (p < 0.01). There was also a statistical correlation between the fracture type and the shear bond strength (p < 0.0005), with cohesively fractured specimens showing higher shear bond strengths (37.24 ± 19.87 MPa) than adhesively fractured specimens (23.10 ± 17.65 MPa) (p < 0.001). CONCLUSION: Using universal primer can enhance the maximal shear bond strength of zirconia.


Subject(s)
Dental Bonding , Ceramics , Dental Stress Analysis , Materials Testing , Resin Cements , Shear Strength , Surface Properties , Zirconium
2.
Am J Hum Genet ; 99(5): 1005-1014, 2016 Nov 03.
Article in English | MEDLINE | ID: mdl-27745832

ABSTRACT

Periodontal Ehlers-Danlos syndrome (pEDS) is an autosomal-dominant disorder characterized by early-onset periodontitis leading to premature loss of teeth, joint hypermobility, and mild skin findings. A locus was mapped to an approximately 5.8 Mb region at 12p13.1 but no candidate gene was identified. In an international consortium we recruited 19 independent families comprising 107 individuals with pEDS to identify the locus, characterize the clinical details in those with defined genetic causes, and try to understand the physiological basis of the condition. In 17 of these families, we identified heterozygous missense or in-frame insertion/deletion mutations in C1R (15 families) or C1S (2 families), contiguous genes in the mapped locus that encode subunits C1r and C1s of the first component of the classical complement pathway. These two proteins form a heterotetramer that then combines with six C1q subunits. Pathogenic variants involve the subunit interfaces or inter-domain hinges of C1r and C1s and are associated with intracellular retention and mild endoplasmic reticulum enlargement. Clinical features of affected individuals in these families include rapidly progressing periodontitis with onset in the teens or childhood, a previously unrecognized lack of attached gingiva, pretibial hyperpigmentation, skin and vascular fragility, easy bruising, and variable musculoskeletal symptoms. Our findings open a connection between the inflammatory classical complement pathway and connective tissue homeostasis.


Subject(s)
Complement C1r/genetics , Complement C1s/genetics , Ehlers-Danlos Syndrome/genetics , Gene Deletion , Mutation, Missense , Periodontitis/genetics , Adolescent , Adult , Child , Child, Preschool , Chromosome Mapping , Chromosomes, Human, Pair 12/genetics , Ehlers-Danlos Syndrome/diagnosis , Endoplasmic Reticulum/genetics , Endoplasmic Reticulum/metabolism , Exome , Female , Genetic Loci , Humans , Male , Pedigree , Periodontitis/diagnosis , Protein Conformation , Young Adult
3.
J Prosthet Dent ; 113(6): 616-22, 2015 Jun.
Article in English | MEDLINE | ID: mdl-25794914

ABSTRACT

STATEMENT OF PROBLEM: During the insertion appointment, the practitioner is often faced with the need to adjust ceramic surfaces to fit a restoration to the adjacent or opposing dentition and soft tissues. PURPOSE: The purpose of this study was to assess the ceramic surface smoothness achieved with various commercially available ceramic polishing kits on different commonly used ceramic systems. The reliability of the cost of a polishing kit as an indicator of improved surface smoothness was assessed. MATERIAL AND METHODS: A total of 350 ceramic surfaces representing 5 commonly available ceramic systems (IPS Empress Esthetic, IPS e.max Press, Cergo Kiss, Vita PM 9, Imagine PressX) were treated with 5 types of ceramic polishing systems (Cerapreshine, 94006C, Ceramiste, Optrafine, Zenostar) by following the manufacturers' guidelines. The surface roughness was measured with a profilometer (Taylor Hobson; Precision Taylor Hobson Ltd). The effects of ceramic systems and polishing kits of interest on surface roughness were analyzed by 2-way ANOVA, paired t test, and Bonferroni corrected significance level. RESULTS: The ceramic systems and polishing kits statistically affected surface roughness (P<.001).The polishing kit Zenostar on IPS e.max Press created the smoothest ceramic surface. No correlation could be established between the high cost of the polishing kit and low surface roughness. None of the commonly used ceramic polishing kits could create a surface smoother than that of glazed ceramic (P<.001). CONCLUSIONS: The inclusion of a diamond polishing paste step is recommended to improve surface smoothness (P<.001). The cost of ceramic polishing kits is not recommended as a reliable indicator of better performance of ceramic polishing kits (P>.30).


Subject(s)
Ceramics/chemistry , Dental Materials/chemistry , Dental Polishing/instrumentation , Aluminum Silicates/chemistry , Cost-Benefit Analysis , Dental Polishing/economics , Dental Porcelain/chemistry , Diamond/chemistry , Humans , Materials Testing , Surface Properties
4.
Wien Klin Wochenschr ; 125(21-22): 680-6, 2013 Nov.
Article in English | MEDLINE | ID: mdl-24146325

ABSTRACT

Odontogenic infections represented a challenge for every craniomaxillofacial surgeon in the pre-antibiotic era, not least due to the frequent association with septic complications and lethal consequences. Nowadays, the incidences of serious infection-related complications are less frequent thanks to the medical progress. Nevertheless, the development of severe infections is still hard to foresee. The following analysis provides an overview of four patients with severe, life-threatening odontogenic deep neck space infections treated at the University Clinic for Oral and Maxillofacial Surgery in Innsbruck and describes the etiology, therapy, and outcome for each patient while analyzing differences between the single cases. Crucial aspects in origin, progression, and treatment of DNIs are highlighted, comparing the results with the international literature.


Subject(s)
Anti-Bacterial Agents/therapeutic use , Drainage , Focal Infection, Dental/complications , Focal Infection, Dental/therapy , Soft Tissue Infections/complications , Soft Tissue Infections/therapy , Tooth Extraction , Adult , Aged , Combined Modality Therapy , Edema/diagnosis , Edema/etiology , Edema/prevention & control , Fatal Outcome , Female , Focal Infection, Dental/diagnosis , Humans , Male , Neck/diagnostic imaging , Neck/microbiology , Neck/pathology , Radiography , Soft Tissue Infections/diagnosis , Treatment Outcome
5.
Acta Odontol Scand ; 71(3-4): 994-9, 2013.
Article in English | MEDLINE | ID: mdl-23140517

ABSTRACT

OBJECTIVE: The aim of this study was to evaluate the clinical efficacy of an in-office desensitizing paste containing 8% arginine and calcium carbonate relative to calcium carbonate alone in the reduction of dentin hypersensitivity in a randomized, double-blind, split-mouth clinical trial. MATERIALS AND METHODS: Sixty teeth (30 subjects) with an air blast hypersensitivity score of 2 or 3 (Schiff Cold Air Sensitivity Scale) were randomly assigned to one of two treatment groups: (1) test paste containing 8% arginine and calcium carbonate (elmex sensitive professional desensitizing paste) and (2) control paste: paris white (calcium carbonate). Tactile and air blast dentin hypersensitivity examinations were performed at baseline, immediately after paste application and 4 and 12 weeks later. RESULTS: A statistically significant difference in air blast (p = 0.001) and tactile (p = 0.047) hypersensitivity reduction over time was observed between the two therapy modes. After 12-weeks, statistically significant differences were indicated between the test and control group with respect to baseline-adjusted mean tactile (41.94%; p = 0.038) and air blast hypersensitivity scores (46.5%; p = 0.017). CONCLUSIONS: The tested in-office desensitizing paste containing 8.0% arginine and calcium carbonate provides significantly greater hypersensitivity relief compared to calcium carbonate alone.


Subject(s)
Arginine/administration & dosage , Calcium Carbonate/administration & dosage , Dentin Sensitivity , Toothpastes , Administration, Topical , Adolescent , Adult , Aged , Aged, 80 and over , Double-Blind Method , Female , Humans , Male , Middle Aged , Office Visits , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...