Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Arch Orthop Trauma Surg ; 142(7): 1589-1595, 2022 Jul.
Article in English | MEDLINE | ID: mdl-34331580

ABSTRACT

INTRODUCTION: The object of this study was to evaluate the primary stability of tibial interference screw (IFS) fixation in single-stage revision surgery of the anterior cruciate ligament (ACL) in the case of recurrent instability after ACL repair with dynamic intraligamentary stabilization (DIS), dependent on the implant position during DIS. MATERIALS AND METHODS: Tibial aperture fixation in ACL reconstruction (ACL-R) was performed in a porcine knee model using an IFS. Native ACL-R was performed in the control group (n = 15). In the intervention groups DIS and subsequent implant removal were performed prior to single-stage revision ACL-R. A distance of 20 mm in group R-DIS1 (n = 15) and 5 mm in group R-DIS2 (n = 15) was left between the joint line and the implant during DIS. Specimens were mounted in a material-testing machine and load-to-failure was applied in a worst-case-scenario. RESULTS: Load to failure was 454 ± 111 N in the R-DIS1 group, 154 ± 71 N in the R-DIS2 group and 405 ± 105 N in the primary ACL-R group. Load-to-failure, stiffness and elongation of the group R-DIS2 were significantly inferior in comparison to R-DIS1 and ACL-R respectively (p < 0.001). No significant difference was found between load-to-failure, stiffness and elongation of R-DIS1 and the control group. CONCLUSION: Primary stability of tibial aperture fixation in single-stage revision ACL-R in case of recurrent instability after DIS depends on monobloc position during ACL repair. Primary stability is comparable to aperture fixation in primary ACL-R, if a bone stock of 20 mm is left between the monobloc and the tibial joint line during the initial procedure.


Subject(s)
Anterior Cruciate Ligament Injuries , Anterior Cruciate Ligament Reconstruction , Animals , Anterior Cruciate Ligament/surgery , Anterior Cruciate Ligament Injuries/surgery , Anterior Cruciate Ligament Reconstruction/methods , Bone Screws , Humans , Knee Joint/surgery , Swine
2.
Injury ; 50(2): 602-606, 2019 Feb.
Article in English | MEDLINE | ID: mdl-30391071

ABSTRACT

PURPOSE: To assess the visibility of both the anterolateral ligament (ALL) and the deep structures of the iliotibial tract (ITT) by means of MRI in paediatric patients. To determine reproducibility for such measurements. METHODS: Knee MRI data from patients aged <18a without lesions of the capsule or ligaments, fractures, bone edemas, foreign material or motion artifacts were analyzed by two musculoskeletal radiologists separately and twice. The visibility of the different parts of the ALL was determined (femoral, meniscal, tibial parts). Similarly, the visibility of the different parts of the deep ITT was determined: deep attachments of the ITT to the distal femur (insertion near septum, supracondylar insertion and retrograde insertion) and capsulo-osseous layer of the ITT. RESULTS: We studied 61 cases (36 female, 25 male). Age was 15 years (±2.3). Interobserver agreement was high. Cohen's Kappa was 0.864 (95%CI: 0.715-1.000) for the tibial part of the ALL and 1.0 for the femoral part of the ALL. For the deep attachments of the ITT to the distal femur Kappa was 0.828 (95%CI: 0.685-0.971). Regarding intraobserver agreement, Cohen's Kappa was 1.0 for the femoral part of the ALL and 0.955 (95%CI: 0.867-1.000) for the tibial part of the ALL. For the deep attachments of the ITT to the distal femur Cohen's Kappa was 0.896 (95%CI: 0.782-1.000). CONCLUSION: On the basis of our findings it is concluded that the presence of the anterolateral structures of the knee can be determined by MRI in a pediatric population with substantial inter- and intraobserver agreement. This is true for both the ALL and the deep structures of the ITT. LEVEL OF EVIDENCE: Diagnostic study - Level 3.


Subject(s)
Ilium/diagnostic imaging , Ligaments, Articular/diagnostic imaging , Magnetic Resonance Imaging , Tibia/diagnostic imaging , Adolescent , Female , Humans , Ilium/anatomy & histology , Ligaments, Articular/anatomy & histology , Male , Reproducibility of Results , Tibia/anatomy & histology
3.
Knee Surg Sports Traumatol Arthrosc ; 27(8): 2530-2536, 2019 Aug.
Article in English | MEDLINE | ID: mdl-30368561

ABSTRACT

PURPOSE: Despite good initial pullout strength, it is unclear whether adjustable button (AB) devices for anterior cruciate ligament (ACL) soft-tissue graft fixation, which are based on the Chinese finger trap technique, resist cyclic loading. Furthermore, they have never been tested in a cyclic protocol including complete unloading. It was hypothesized, that the displacement of AB devices with the Chinese finger trap technique would be greater than that of continuous suture loop devices and other available AB mechanisms in a cyclic loading with complete unloading protocol. METHODS: ACL reconstruction was performed in a porcine knee model using three different types of cortical fixation devices: two different AB devices that use the Chinese finger trap design, one AB device that uses a locked suture loop mechanism and two different continuous loop devices as control groups (n = 40). Specimens were mounted in a material-testing machine (Instron Inc.) that permitted 2500 loading and complete unloading cycles to a maximum of 250 N, as well as continuous elongation recording. A one-way ANOVA was performed for statistical analysis. RESULTS: The displacement of ABs with a Chinese finger trap loop (mean 8.1; SD 1.5 mm and mean 6.1; SD 1.4 mm) was significantly greater than that of AB with a locked suture loop (mean 4.7; SD 1.0 mm; p < 0.05) and devices with a continuous loop (mean 4.1; SD 0.5 mm and mean 4.4, SD 0.3 mm; p < 0.01). No significant differences were detected between the ABs with a locked suture loop and the continuous loops. CONCLUSION: Cyclic loading and unloading of AB using the Chinese finger trap technique leads to significantly greater construct lengthening compared with other devices. Complete unloading of the ACL is very likely to occur during rehabilitation after ACL reconstruction. Lengthening of the AB device due to cyclic loading might be a potential mode of failure of the ACL graft fixation. Therefore, when using an AB femoral fixation technique, a locked suture loop design or a careful rehabilitation protocol should be considered.


Subject(s)
Anterior Cruciate Ligament Reconstruction/instrumentation , Anterior Cruciate Ligament/surgery , Disease Models, Animal , Femur/surgery , Internal Fixators , Knee Joint/surgery , Animals , Biomechanical Phenomena , Swine
SELECTION OF CITATIONS
SEARCH DETAIL
...