2.
IEEE Trans Med Imaging ; 40(7): 1888-1897, 2021 07.
Article in English | MEDLINE | ID: mdl-33755561

ABSTRACT

Photoacoustic (PA) imaging can revolutionize medical ultrasound by augmenting it with molecular information. However, clinical translation of PA imaging remains a challenge due to the limited viewing angles and imaging depth. Described here is a new robust algorithm called Superiorized Photo-Acoustic Non-NEgative Reconstruction (SPANNER), designed to reconstruct PA images in real-time and to address the artifacts associated with limited viewing angles and imaging depth. The method utilizes precise forward modeling of the PA propagation and reception of signals while accounting for the effects of acoustic absorption, element size, shape, and sensitivity, as well as the transducer's impulse response and directivity pattern. A fast superiorized conjugate gradient algorithm is used for inversion. SPANNER is compared to three reconstruction algorithms: delay-and-sum (DAS), universal back-projection (UBP), and model-based reconstruction (MBR). All four algorithms are applied to both simulations and experimental data acquired from tissue-mimicking phantoms, ex vivo tissue samples, and in vivo imaging of the prostates in patients. Simulations and phantom experiments highlight the ability of SPANNER to improve contrast to background ratio by up to 20 dB compared to all other algorithms, as well as a 3-fold increase in axial resolution compared to DAS and UBP. Applying SPANNER on contrast-enhanced PA images acquired from prostate cancer patients yielded a statistically significant difference before and after contrast agent administration, while the other three image reconstruction methods did not, thus highlighting SPANNER's performance in differentiating intrinsic from extrinsic PA signals and its ability to quantify PA signals from the contrast agent more accurately.


Subject(s)
Photoacoustic Techniques , Acoustics , Algorithms , Artifacts , Humans , Image Processing, Computer-Assisted , Phantoms, Imaging
3.
J Hosp Med ; 7(8): 628-33, 2012 Oct.
Article in English | MEDLINE | ID: mdl-22865462

ABSTRACT

BACKGROUND: Continuous vital sign monitoring has the potential to detect early clinical deterioration. While commonly employed in the intensive care unit (ICU), accurate and noninvasive monitoring technology suitable for floor patients has yet to be used reliably. OBJECTIVE: To establish the accuracy of the Earlysense continuous monitoring system in predicting clinical deterioration. DESIGN: Noninterventional prospective study with retrospective data analysis. SETTING: Two medical wards in 2 academic medical centers. PATIENTS: Patients admitted to a medical ward with a diagnosis of an acute respiratory condition. INTERVENTION: Enrolled patients were monitored for heart rate (HR) and respiration rate (RR) by the Earlysense monitor with the alerts turned off. MEASUREMENTS: Retrospective analysis of vital sign data was performed on a derivation cohort to identify optimal cutoffs for threshold and 24-hour trend alerts. This was internally validated through correlation with clinical events recognized through chart review. RESULTS: Of 113 patients included in the study, 9 suffered major clinical deterioration. Alerts were found to be infrequent (2.7 and 0.2 alerts per patient-day for threshold and trend alert, respectively). For the threshold alerts, sensitivity and specificity in predicting deterioration was found to be 82% and 67%, respectively, for HR and 64% and 81%, respectively, for RR. For trend alerts, sensitivity and specificity were 78% and 90% for HR, and 100% and 64% for RR, respectively. CONCLUSIONS: The Earlysense monitor was able to continuously measure RR and HR, providing low alert frequency. The current study provides data supporting the ability of this system to accurately predict patient deterioration.


Subject(s)
Diffusion of Innovation , Heart Rate/physiology , Inpatients , Monitoring, Physiologic/methods , Respiratory Rate/physiology , Academic Medical Centers , Acute Disease , Aged , Female , Humans , Male , Predictive Value of Tests , Retrospective Studies , Sensitivity and Specificity , Time Factors , Vital Signs