Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Crit Care ; 22(1): 121, 2018 May 09.
Article in English | MEDLINE | ID: mdl-29743121

ABSTRACT

BACKGROUND: Recent clinical studies have not shown an overall benefit of high-frequency oscillatory ventilation (HFOV), possibly due to injurious or non-individualized HFOV settings. We compared conventional HFOV (HFOVcon) settings with HFOV settings based on mean transpulmonary pressures (PLmean) in an animal model of experimental acute respiratory distress syndrome (ARDS). METHODS: ARDS was induced in eight pigs by intrabronchial installation of hydrochloric acid (0.1 N, pH 1.1; 2.5 ml/kg body weight). The animals were initially ventilated in volume-controlled mode with low tidal volumes (6 ml kg- 1) at three positive end-expiratory pressure (PEEP) levels (5, 10, 20 cmH2O) followed by HFOVcon and then HFOV PLmean each at PEEP 10 and 20. The continuous distending pressure (CDP) during HFOVcon was set at mean airway pressure plus 5 cmH2O. For HFOV PLmean it was set at mean PL plus 5 cmH2O. Baseline measurements were obtained before and after induction of ARDS under volume controlled ventilation with PEEP 5. The same measurements and computer tomography of the thorax were then performed under all ventilatory regimens at PEEP 10 and 20. RESULTS: Cardiac output, stroke volume, mean arterial pressure and intrathoracic blood volume index were significantly higher during HFOV PLmean than during HFOVcon at PEEP 20. Lung density, total lung volume, and normally and poorly aerated lung areas were significantly greater during HFOVcon, while there was less over-aerated lung tissue in HFOV PLmean. The groups did not differ in oxygenation or extravascular lung water index. CONCLUSION: HFOV PLmean is associated with less hemodynamic compromise and less pulmonary overdistension than HFOVcon. Despite the increase in non-ventilated lung areas, oxygenation improved with both regimens. An individualized approach with HFOV settings based on transpulmonary pressure could be a useful ventilatory strategy in patients with ARDS. Providing alveolar stabilization with HFOV while avoiding harmful distending pressures and pulmonary overdistension might be a key in the context of ventilator-induced lung injury.


Subject(s)
High-Frequency Ventilation/standards , Monitoring, Physiologic/methods , Pressure , Respiratory Distress Syndrome/therapy , Animals , Arterial Pressure/physiology , Blood Volume Determination/methods , Cardiac Output/physiology , High-Frequency Ventilation/methods , Lung/blood supply , Lung/metabolism , Lung/physiopathology , Monitoring, Physiologic/statistics & numerical data , Monitoring, Physiologic/trends , Positive-Pressure Respiration/methods , Pulmonary Gas Exchange/physiology , Stroke Volume/physiology , Swine
2.
PLoS One ; 12(10): e0186481, 2017.
Article in English | MEDLINE | ID: mdl-29049339

ABSTRACT

BACKGROUND: Monitoring cardiac output (CO) is important to optimize hemodynamic function in critically ill patients. The prevalence of aortic valve insufficiency (AI) is rising in the aging population. However, reliability of CO monitoring techniques in AI is unknown. The aim of this study was to investigate the impact of AI on accuracy, precision, and trending ability of transcardiopulmonary thermodilution-derived COTCPTD in comparison with pulmonary artery catheter thermodilution COPAC. METHODS: Sixteen anesthetized domestic pigs were subjected to serial simultaneous measurements of COPAC and COTCPTD. In a novel experimental model, AI was induced by retraction of an expanded Dormia basket in the aortic valve annulus. The Dormia basket was delivered via a Judkins catheter guided by substernal epicardial echocardiography. High (HPC), moderate (MPC) and low cardiac preload conditions (LPC) were induced by fluid unloading (20 ml kg-1 blood withdrawal) and loading (subsequent retransfusion of the shed blood and additional infusion of 20 ml kg-1 hydroxyethyl starch). Within each preload condition CO was measured before and after the onset of AI. For statistical analysis, we used a mixed model analysis of variance, Bland-Altman analysis, the percentage error and concordance analysis. RESULTS: Experimental AI had a mean regurgitant volume of 33.6 ± 12.0 ml and regurgitant fraction of 42.9 ± 12.6%. The percentage error between COTCPTD and COPAC during competent valve function and after induction of substantial AI was: HPC 17.7% vs. 20.0%, MPC 20.5% vs. 26.1%, LPC 26.5% vs. 28.1% (pooled data: 22.5% vs. 24.1%). The ability to trend CO-changes induced by fluid loading and unloading did not differ between baseline and AI (concordance rate 95.8% during both conditions). CONCLUSION: Despite substantial AI, transcardiopulmonary thermodilution reliably measured CO under various cardiac preload conditions with a good ability to trend CO changes in a porcine model. COTCPTD and COPAC were interchangeable in substantial AI.


Subject(s)
Aortic Valve Insufficiency/physiopathology , Cardiac Output , Thermodilution/methods , Animals , Reproducibility of Results , Swine
3.
J Crit Care ; 42: 184-191, 2017 12.
Article in English | MEDLINE | ID: mdl-28759880

ABSTRACT

Quantitative lung computed tomographic (CT) analysis yields objective data regarding lung aeration but is currently not used in clinical routine primarily because of the labor-intensive process of manual CT segmentation. Automatic lung segmentation could help to shorten processing times significantly. In this study, we assessed bias and precision of lung CT analysis using automatic segmentation compared with manual segmentation. In this monocentric clinical study, 10 mechanically ventilated patients with mild to moderate acute respiratory distress syndrome were included who had received lung CT scans at 5- and 45-mbar airway pressure during a prior study. Lung segmentations were performed both automatically using a computerized algorithm and manually. Automatic segmentation yielded similar lung volumes compared with manual segmentation with clinically minor differences both at 5 and 45 mbar. At 5 mbar, results were as follows: overdistended lung 49.58mL (manual, SD 77.37mL) and 50.41mL (automatic, SD 77.3mL), P=.028; normally aerated lung 2142.17mL (manual, SD 1131.48mL) and 2156.68mL (automatic, SD 1134.53mL), P = .1038; and poorly aerated lung 631.68mL (manual, SD 196.76mL) and 646.32mL (automatic, SD 169.63mL), P = .3794. At 45 mbar, values were as follows: overdistended lung 612.85mL (manual, SD 449.55mL) and 615.49mL (automatic, SD 451.03mL), P=.078; normally aerated lung 3890.12mL (manual, SD 1134.14mL) and 3907.65mL (automatic, SD 1133.62mL), P = .027; and poorly aerated lung 413.35mL (manual, SD 57.66mL) and 469.58mL (automatic, SD 70.14mL), P=.007. Bland-Altman analyses revealed the following mean biases and limits of agreement at 5 mbar for automatic vs manual segmentation: overdistended lung +0.848mL (±2.062mL), normally aerated +14.51mL (±49.71mL), and poorly aerated +14.64mL (±98.16mL). At 45 mbar, results were as follows: overdistended +2.639mL (±8.231mL), normally aerated 17.53mL (±41.41mL), and poorly aerated 56.23mL (±100.67mL). Automatic single CT image and whole lung segmentation were faster than manual segmentation (0.17 vs 125.35seconds [P<.0001] and 10.46 vs 7739.45seconds [P<.0001]). Automatic lung CT segmentation allows fast analysis of aerated lung regions. A reduction of processing times by more than 99% allows the use of quantitative CT at the bedside.


Subject(s)
Lung/diagnostic imaging , Respiratory Distress Syndrome/diagnostic imaging , Tidal Volume/physiology , Tomography, X-Ray Computed , Adult , Aged , Aged, 80 and over , Algorithms , Deep Sedation , Evaluation Studies as Topic , Female , Humans , Male , Middle Aged , Point-of-Care Systems , Respiratory Distress Syndrome/physiopathology , Tomography, X-Ray Computed/methods
4.
Emerg Infect Dis ; 11(4): 613-5, 2005 Apr.
Article in English | MEDLINE | ID: mdl-15829203

ABSTRACT

We report 2 clinically characteristic and serologically positive cases of Ross River virus infection in Canadian tourists who visited Fiji in late 2003 and early 2004. This report suggests that Ross River virus is once again circulating in Fiji, where it apparently disappeared after causing an epidemic in 1979 to 1980.


Subject(s)
Alphavirus Infections/diagnosis , Ross River virus/isolation & purification , Adult , Alphavirus Infections/epidemiology , Disease Outbreaks , Female , Fiji/epidemiology , Humans , Male
SELECTION OF CITATIONS
SEARCH DETAIL
...