Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Pharm Biomed Anal ; 94: 71-6, 2014 Jun.
Article in English | MEDLINE | ID: mdl-24552644

ABSTRACT

Two new impurities were described and determined using gradient HPLC method with UV detection in retigabine (RET). Using LC-HRMS, NMR and IR analysis the impurities were identified as RET-dimer I: diethyl {4,4'-diamino-6,6'-bis[(4-fluorobenzyl)amino]biphenyl-3,3'-diyl}biscarbamate and RET-dimer II: ethyl {2-amino-5-[{2-amino-4-[(4-fluorobenzyl) amino] phenyl} (ethoxycarbonyl) amino]-4-[(4-fluorobenzyl)amino] phenyl}carbamate. Reference standards of these impurities were synthesized followed by semipreparative HPLC purification. The mechanism of the formation of these impurities is also discussed. An HPLC method was optimized in order to separate, selectively detect and quantify all process-related impurities and degradation products of RET. The presented method, which was validated in terms of linearity, limit of detection (LOD), limit of quantification (LOQ) and selectivity is very quick (less than 11min including re-equilibration time) and therefore highly suitable for routine analysis of RET related substances as well as stability studies.


Subject(s)
Carbamates/chemistry , Phenylenediamines/chemistry , Chromatography, High Pressure Liquid/methods , Drug Contamination , Drug Stability , Limit of Detection , Reference Standards
2.
J Pharm Biomed Anal ; 58: 1-6, 2012 Jan 25.
Article in English | MEDLINE | ID: mdl-21982522

ABSTRACT

A new impurity was detected and determined using gradient ion-pair UHPLC method with UV detection in zolmitriptan (ZOL). Using MS, NMR and IR study the impurity was identified as (4S,4'S)-4,4'-(2,2'-(4-(dimethylamino)butane-1,1-diyl)bis(3-(2-(dimethylamino) ethyl)-1H-indole-5,2-diyl))bis(methylene)di(oxazolidin-2-one) (ZOL-dimer). The standard of ZOL-dimer was consequently prepared via organic synthesis followed by semipreparative HPLC purification. The UHPLC method was optimized in order to selectively detect and quantify other known and unknown process-related impurities and degradation products of ZOL as well. The presented method which was validated with respect to linearity, accuracy, precision and selectivity has an advantage of a very quick UHPLC chromatographic separation (less than 7 min including re-equilibration time) and therefore is highly suitable for routine analysis of related substances and stability studies of ZOL.


Subject(s)
Chromatography, High Pressure Liquid/methods , Drug Contamination , Oxazolidinones/chemistry , Tryptamines/chemistry , Chemistry Techniques, Synthetic/methods , Limit of Detection , Magnetic Resonance Spectroscopy/methods , Mass Spectrometry/methods , Oxazoles/isolation & purification , Oxazolidinones/isolation & purification , Spectrophotometry, Infrared/methods , Spectrophotometry, Ultraviolet/methods , Tryptamines/isolation & purification
SELECTION OF CITATIONS