Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 337
Filter
1.
Eur Heart J ; 2024 May 31.
Article in English | MEDLINE | ID: mdl-38820201

ABSTRACT

BACKGROUND AND AIMS: Surgical explantation of transcatheter heart valves (THVs) is rapidly increasing, but there are limited data on patients with THV-associated infective endocarditis (IE). This study aims to assess the outcomes of patients undergoing THV explant for IE. METHODS: All patients who underwent THV explant between 2011 and 2022 from 44 sites in the EXPLANT-TAVR registry were identified. Patients with IE as the reason for THV explant were compared to those with other mechanisms of bioprosthetic valve dysfunction (BVD). RESULTS: A total of 372 patients from the EXPLANT-TAVR registry were included. Among them, 184 (49.5%) patients underwent THV explant due to IE and 188 (50.5%) patients due to BVD. At the index transcatheter aortic valve replacement, patients undergoing THV explant for IE were older (74.3 ± 8.6 vs. 71 ± 10.6 years) and had a lower Society of Thoracic Surgeons risk score [2.6% (1.8-5.0) vs. 3.3% (2.1-5.6), P = .029] compared to patients with BVD. Compared to BVD, IE patients had longer intensive care unit and hospital stays (P < .05) and higher stroke rates at 30 days (8.6% vs. 2.9%, P = .032) and 1 year (16.2% vs. 5.2%, P = .010). Adjusted in-hospital, 30-day, and 1-year mortality was 12.1%, 16.1%, and 33.8%, respectively, for the entire cohort, with no significant differences between groups. Although mortality was numerically higher in IE patients 3 years postsurgery (29.6% for BVD vs. 43.9% for IE), Kaplan-Meier analysis showed no significant differences between groups (P = .16). CONCLUSIONS: In the EXPLANT-TAVR registry, patients undergoing THV explant for IE had higher 30-day and 1-year stroke rates and longer intensive care unit and hospital stays. Moreover, patients undergoing THV explant for IE had a higher 3-year mortality rate, which did not reach statistical significance given the relatively small sample size of this unique cohort and the reduced number of events.

2.
JACC Cardiovasc Interv ; 17(8): 979-988, 2024 Apr 22.
Article in English | MEDLINE | ID: mdl-38658126

ABSTRACT

BACKGROUND: Symptomatic patients with severe aortic stenosis (AS) at high risk for surgical aortic valve replacement (SAVR) sustain comparable improvements in health status over 5 years after transcatheter aortic valve replacement (TAVR) or SAVR. Whether a similar long-term benefit is observed among intermediate-risk AS patients is unknown. OBJECTIVES: The purpose of this study was to assess health status outcomes through 5 years in intermediate risk patients treated with a self-expanding TAVR prosthesis or SAVR using data from the SURTAVI (Surgical Replacement and Transcatheter Aortic Valve Implantation) trial. METHODS: Intermediate-risk patients randomized to transfemoral TAVR or SAVR in the SURTAVI trial had disease-specific health status assessed at baseline, 30 days, and annually to 5 years using the Kansas City Cardiomyopathy Questionnaire (KCCQ). Health status was compared between groups using fixed effects repeated measures modelling. RESULTS: Of the 1,584 patients (TAVR, n = 805; SAVR, n = 779) included in the analysis, health status improved more rapidly after TAVR compared with SAVR. However, by 1 year, both groups experienced large health status benefits (mean change in KCCQ-Overall Summary Score (KCCQ-OS) from baseline: TAVR: 20.5 ± 22.4; SAVR: 20.5 ± 22.2). This benefit was sustained, albeit modestly attenuated, at 5 years (mean change in KCCQ-OS from baseline: TAVR: 15.4 ± 25.1; SAVR: 14.3 ± 24.2). There were no significant differences in health status between the cohorts at 1 year or beyond. Similar findings were observed in the KCCQ subscales, although a substantial attenuation of benefit was noted in the physical limitation subscale over time in both groups. CONCLUSIONS: In intermediate-risk AS patients, both transfemoral TAVR and SAVR resulted in comparable and durable health status benefits to 5 years. Further research is necessary to elucidate the mechanisms for the small decline in health status noted at 5 years compared with 1 year in both groups. (Safety and Efficacy Study of the Medtronic CoreValve® System in the Treatment of Severe, Symptomatic Aortic Stenosis in Intermediate Risk Subjects Who Need Aortic Valve Replacement [SURTAVI]; NCT01586910).


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Femoral Artery , Health Status , Heart Valve Prosthesis , Quality of Life , Recovery of Function , Severity of Illness Index , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Female , Male , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Treatment Outcome , Aged , Aged, 80 and over , Risk Factors , Aortic Valve/surgery , Aortic Valve/physiopathology , Aortic Valve/diagnostic imaging , Risk Assessment , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/adverse effects , Catheterization, Peripheral/adverse effects , Punctures , Prosthesis Design
3.
J Am Heart Assoc ; 13(8): e033510, 2024 Apr 16.
Article in English | MEDLINE | ID: mdl-38567665

ABSTRACT

BACKGROUND: Pulmonary hypertension (PH) and secondary mitral regurgitation (MR) are associated with adverse outcomes after mitral transcatheter edge-to-edge repair. We aim to study the prognostic value of invasively measured right ventricular afterload in patients undergoing mitral transcatheter edge-to-edge repair. METHODS AND RESULTS: We identified patients who underwent right heart catheterization ≤1 month before transcatheter edge-to-edge repair. The end points were all-cause mortality and a composite of mortality and heart failure hospitalization at 2 years. Using the receiver operating characteristic curve-derived threshold of 0.6 for pulmonary effective arterial elastance ([Ea], pulmonary artery systolic pressure/stroke volume), patients were stratified into 3 profiles based on PH severity (low elastance [HE]: Ea <0.6/mean pulmonary artery pressure (mPAP)) <35; High Elastance with No/Mild PH (HE-): Ea ≥0.6/mPAP <35; and HE with Moderate/Severe PH (HE+): Ea ≥0.6/mPAP ≥35) and MR pathogenesis (Primary MR [PMR])/low elastance, PMR/HE, and secondary MR). The association between this classification and clinical outcomes was examined using Cox regression. Among 114 patients included, 50.9% had PMR. Mean±SD age was 74.7±10.6 years. Patients with Ea ≥0.6 were more likely to have diabetes, atrial fibrillation, New York Heart Association III/IV status, and secondary MR (all P<0.05). Overall, 2-year cumulative survival was 71.1% and was lower in patients with secondary MR and mPAP ≥35. Compared with patients with low elastance, cumulative 2-year event-free survival was significantly lower in HE- and HE+ patients (85.5% versus 50.4% versus 41.0%, respectively, P=0.001). Also, cumulative 2-year event-free survival was significantly higher in patients with PMR/low elastance when compared with PMR/HE and patients with secondary mitral regurgitation (85.5% versus 55.5% versus 46.1%, respectively, P=0.005). CONCLUSIONS: Assessment of the preprocedural cardiopulmonary profile based on mPAP, MR pathogenesis, and Ea guides patient selection by identifying hemodynamic features that indicate likely benefit from mitral-transcatheter edge-to-edge repair in PH or lack thereof.


Subject(s)
Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Humans , Middle Aged , Aged , Aged, 80 and over , Prognosis , Mitral Valve Insufficiency/surgery , Hemodynamics , Cardiac Catheterization/adverse effects , Pulmonary Artery , Treatment Outcome , Heart Valve Prosthesis Implantation/adverse effects
4.
JACC Cardiovasc Interv ; 17(8): 1007-1016, 2024 Apr 22.
Article in English | MEDLINE | ID: mdl-38573257

ABSTRACT

BACKGROUND: Data on valve reintervention after transcatheter aortic valve replacement (TAVR) or surgical aortic valve replacement (SAVR) are limited. OBJECTIVES: The authors compared the 5-year incidence of valve reintervention after self-expanding CoreValve/Evolut TAVR vs SAVR. METHODS: Pooled data from CoreValve and Evolut R/PRO (Medtronic) randomized trials and single-arm studies encompassed 5,925 TAVR (4,478 CoreValve and 1,447 Evolut R/PRO) and 1,832 SAVR patients. Reinterventions were categorized by indication, timing, and treatment. The cumulative incidence of reintervention was compared between TAVR vs SAVR, Evolut vs CoreValve, and Evolut vs SAVR. RESULTS: There were 99 reinterventions (80 TAVR and 19 SAVR). The cumulative incidence of reintervention through 5 years was higher with TAVR vs SAVR (2.2% vs 1.5%; P = 0.017), with differences observed early (≤1 year; adjusted subdistribution HR: 3.50; 95% CI: 1.53-8.02) but not from >1 to 5 years (adjusted subdistribution HR: 1.05; 95% CI: 0.48-2.28). The most common reason for reintervention was paravalvular regurgitation after TAVR and endocarditis after SAVR. Evolut had a significantly lower incidence of reintervention than CoreValve (0.9% vs 1.6%; P = 0.006) at 5 years with differences observed early (adjusted subdistribution HR: 0.30; 95% CI: 0.12-0.73) but not from >1 to 5 years (adjusted subdistribution HR: 0.61; 95% CI: 0.21-1.74). The 5-year incidence of reintervention was similar for Evolut vs SAVR (0.9% vs 1.5%; P = 0.41). CONCLUSIONS: A low incidence of reintervention was observed for CoreValve/Evolut R/PRO and SAVR through 5 years. Reintervention occurred most often at ≤1 year for TAVR and >1 year for SAVR. Most early reinterventions were with the first-generation CoreValve and managed percutaneously. Reinterventions were more common following CoreValve TAVR compared with Evolut TAVR or SAVR.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Postoperative Complications , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Female , Humans , Male , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Heart Valve Prosthesis , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/instrumentation , Postoperative Complications/surgery , Prosthesis Design , Randomized Controlled Trials as Topic , Risk Assessment , Risk Factors , Severity of Illness Index , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Treatment Outcome , Incidence , Retreatment
6.
Article in English | MEDLINE | ID: mdl-38553281

ABSTRACT

BACKGROUND: The role of percutaneous coronary intervention (PCI) in patients with stable coronary artery disease (CAD) who subsequently undergo transcatheter aortic valve replacement (TAVR) remains uncertain. Therefore, we conducted this study to assess the association of PCI before TAVR with mortality and cardiovascular outcomes. METHODS: We used the TriNetX database (Jan 2012 - Aug 2022) and grouped patients into PCI (3 months or less) before TAVR and no PCI. We performed propensity score matched (PSM) analyses for outcomes at 30 days and 1 year. RESULTS: Of 17,120 patients undergoing TAVR, 2322 (14 %) had PCI, and 14,798 (86 %) did not have PCI before TAVR. In the PSM cohort (2026 patients in each group), PCI was not associated with lower all-cause mortality at 30 days (HR: 1.25, 95 % CI: 0.82-1.90) or 1 year (HR: 1.02, 95 % CI: 0.83-1.24). Frequency of repeat PCI after TAVR was low in both no PCI vs. PCI (2.4 % vs. 1.2 %) at 1 year; PCI was associated with a lower rate of repeat PCI (HR: 0.49, 95 % CI: 0.30-0.80). Sensitivity analysis revealed an E-value of 3.5 for repeat PCI (E-value for lower CI for HR: 1.81). PCI was not linked to reductions in MI, heart failure exacerbation, all-cause hospitalization, major bleeding, or permanent pacemaker/implantable cardioverter defibrillator. CONCLUSION: This analysis showed that PCI prior to TAVR was not associated with improvement in all-cause mortality. However, PCI was associated with a reduced rate of repeat PCI at 1 year.

9.
J Am Heart Assoc ; 13(5): e032784, 2024 Mar 05.
Article in English | MEDLINE | ID: mdl-38390821

ABSTRACT

BACKGROUND: Prior studies investigating the impact of residual mitral regurgitation (MR), tricuspid regurgitation (TR), and elevated predischarge transmitral mean pressure gradient (TMPG) on outcomes after mitral transcatheter edge-to-edge repair (TEER) have assessed each parameter in isolation. We sought to examine the prognostic value of combining predischarge MR, TR, and TMPG to study long-term outcomes after TEER. METHODS AND RESULTS: We reviewed the records of 291 patients who underwent successful mitral TEER at our institution between March 2014 and June 2022. Using well-established outcomes-related cutoffs for predischarge MR (≥moderate), TR (≥moderate), and TMPG (≥5 mm Hg), 3 echo profiles were developed based on the number of risk factors present (optimal: 0 risk factors, mixed: 1 risk factor, poor: ≥2 risk factors). Discrimination of the profiles for predicting the primary composite end point of all-cause mortality and heart failure hospitalization at 2 years was examined using Cox regression. Overall, mean age was 76.7±10.6 years, 43.3% were women, and 53% had primary MR. Two-year event-free survival was 61%. Predischarge TR≥moderate, MR≥moderate, and TMPG≥5 mm Hg were risk factors associated with the primary end point. Compared with the optimal profile, there was an incremental risk in 2-year event-rate with each worsening profile (optimal as reference; mixed profile: hazard ratio (HR), 2.87 [95% CI, 1.71-5.17], P<0.001; poor profile: HR, 3.76 [95% CI, 1.84-6.53], P<0.001). Echocardiographic profile was statistically associated with the 2-year mortality end point (optimal as reference; mixed profile: HR, 3.55 [95% CI, 1.81-5.96], P<0.001; poor profile: HR, 3.39 [95% CI, 2.56-7.33], P=0.02). CONCLUSIONS: The echocardiographic profile integrating predischarge TR, MR, and TMPG presents a novel prognostic stratification tool for patients undergoing mitral TEER.


Subject(s)
Heart Failure , Heart Valve Prosthesis Implantation , Mercury , Mitral Valve Insufficiency , Tricuspid Valve Insufficiency , Humans , Female , Aged , Aged, 80 and over , Male , Echocardiography , Health Facilities , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Tricuspid Valve Insufficiency/diagnostic imaging , Tricuspid Valve Insufficiency/surgery , Treatment Outcome , Heart Valve Prosthesis Implantation/adverse effects , Cardiac Catheterization
10.
EuroIntervention ; 20(2): e146-e157, 2024 Jan 15.
Article in English | MEDLINE | ID: mdl-38224255

ABSTRACT

BACKGROUND: There are limited data on the impact of transcatheter heart valve (THV) type on the outcomes of surgical explantation after THV failure. AIMS: We sought to determine the outcomes of transcatheter aortic valve replacement (TAVR) explantation for failed balloon-expandable valves (BEV) versus self-expanding valves (SEV). METHODS: From November 2009 to February 2022, 401 patients across 42 centres in the EXPLANT-TAVR registry underwent TAVR explantation during a separate admission from the initial TAVR. Mechanically expandable valves (N=10, 2.5%) were excluded. The outcomes of TAVR explantation were compared for 202 (51.7%) failed BEV and 189 (48.3%) failed SEV. RESULTS: Among 391 patients analysed (mean age: 73.0±9.8 years; 33.8% female), the median time from index TAVR to TAVR explantation was 13.3 months (interquartile range 5.1-34.8), with no differences between groups. Indications for TAVR explantation included endocarditis (36.0% failed SEV vs 55.4% failed BEV; p<0.001), paravalvular leak (21.2% vs 11.9%; p=0.014), structural valve deterioration (30.2% vs 21.8%; p=0.065) and prosthesis-patient mismatch (8.5% vs 10.4%; p=0.61). The SEV group trended fewer urgent/emergency surgeries (52.0% vs 62.3%; p=0.057) and more root replacement (15.3% vs 7.4%; p=0.016). Concomitant cardiac procedures were performed in 57.8% of patients, including coronary artery bypass graft (24.8%), and mitral (38.9%) and tricuspid (14.6%) valve surgery, with no differences between groups. In-hospital, 30-day, and 1-year mortality and stroke rates were similar between groups (allp>0.05), with no differences in cumulative mortality at 3 years (log-rank p=0.95). On multivariable analysis, concomitant mitral surgery was an independent predictor of 1-year mortality after BEV explant (hazard ratio [HR] 2.00, 95% confidence interval [CI]: 1.07-3.72) and SEV explant (HR 2.00, 95% CI: 1.08-3.69). CONCLUSIONS: In the EXPLANT-TAVR global registry, BEV and SEV groups had different indications for surgical explantation, with more root replacements in SEV failure, but no differences in midterm mortality and morbidities. Further refinement of TAVR explantation techniques are important to improving outcomes.


Subject(s)
Transcatheter Aortic Valve Replacement , Humans , Female , Middle Aged , Aged , Aged, 80 and over , Male , Transcatheter Aortic Valve Replacement/adverse effects , Device Removal , Catheters , Heart Valves , Registries
13.
Am J Cardiol ; 214: 1-7, 2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38110018

ABSTRACT

Transcatheter aortic valve replacement (TAVR) provides an option for extreme-risk patients who underwent reoperation for a failed surgical aortic bioprosthesis. Long-term data on patients who underwent TAVR within a failed surgical aortic valve (TAV-in-SAV) are limited. The CoreValve Expanded Use Study evaluated patients at extreme surgical risk who underwent TAV-in-SAV. Outcomes at 5 years were analyzed by SAV failure mode (stenosis, regurgitation, or combined). Echocardiographic outcomes are site-reported. TAV-in-SAV was attempted in 226 patients with a mean age of 76.7 ± 10.8 years; 63.3% were male, the Society of Thoracic Surgeons predicted risk of mortality score was 9.0 ± 6.7%, and 87.5% had a New York Heart Association classification III or IV symptoms. Most of the failed surgical bioprostheses were stented (81.9%), with an average implant duration of 10.2 ± 4.3 years. The 5-year all-cause mortality or major stroke rate was 47.2% in all patients; 54.4% in the stenosis, 37.6% in the regurgitation, and 38.0% in the combined groups (p = 0.046). At 5 years, all-cause mortality was higher in patients with versus without 30-day severe prosthesis-patient mismatch (51.7% vs 38.3%, p = 0.026). The overall aortic valve reintervention rate was 5.9%; highest in the regurgitation group (12.6%). The mean aortic valve gradient was 14.1 ± 9.8 mm Hg and effective orifice area was 1.57 ± 0.70 at 5 years. Few patients had >mild paravalvular regurgitation at 5 years (5.5% moderate, 0.0% severe). TAV-in-SAV with supra-annular, self-expanding TAVR continues to represent a safe and lasting intermediate option for extreme-risk patients who have appropriate sizing of the preexisting failed surgical valve. Clinical and hemodynamic outcomes were stable through 5 years.


Subject(s)
Aortic Valve Stenosis , Bioprosthesis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Male , Aged , Aged, 80 and over , Female , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Follow-Up Studies , Constriction, Pathologic/etiology , Constriction, Pathologic/surgery , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/etiology , Treatment Outcome , Transcatheter Aortic Valve Replacement/adverse effects , Surgical Instruments , Prosthesis Design , Risk Factors
15.
BMJ ; 383: e077848, 2023 11 16.
Article in English | MEDLINE | ID: mdl-37973170

ABSTRACT

OBJECTIVE: To assess the absolute treatment effects of intravascular imaging guided versus angiography guided percutaneous coronary intervention in patients with coronary artery disease, considering their baseline risk. DESIGN: Systematic review and meta-analysis. DATA SOURCES: PubMed/Medline, Embase, and Cochrane Library databases up to 31 August 2023. STUDY SELECTION: Randomized controlled trials comparing intravascular imaging (intravascular ultrasonography or optical coherence tomography) guided versus coronary angiography guided percutaneous coronary intervention in adults with coronary artery disease. MAIN OUTCOME MEASURES: Random effect meta-analysis and GRADE (grading of recommendations, assessment, development, and evaluation) were used to assess certainty of evidence. Data included rate ratios and absolute risks per 1000 people for cardiac death, myocardial infarction, stent thrombosis, target vessel revascularization, and target lesion revascularization. Absolute risk differences were estimated using SYNTAX risk categories for baseline risks at five years, assuming constant rate ratios across different cardiovascular risk thresholds. RESULTS: In 20 randomized controlled trials (n=11 698), intravascular imaging guided percutaneous coronary intervention was associated with a reduced risk of cardiac death (rate ratio 0.53, 95% confidence interval 0.39 to 0.72), myocardial infarction (0.81, 0.68 to 0.97), stent thrombosis (0.44, 0.27 to 0.72), target vessel revascularization (0.74, 0.61 to 0.89), and target lesion revascularization (0.71, 0.59 to 0.86) but not all cause death (0.81, 0.64 to 1.02). Using SYNTAX risk categories, high certainty evidence showed that from low risk to high risk, intravascular imaging was likely associated with 23 to 64 fewer cardiac deaths, 15 to 19 fewer myocardial infarctions, 9 to 13 fewer stent thrombosis events, 28 to 38 fewer target vessel revascularization events, and 35 to 48 fewer target lesion revascularization events per 1000 people. CONCLUSIONS: Compared with coronary angiography guided percutaneous coronary intervention, intravascular imaging guided percutaneous coronary intervention was associated with significantly reduced cardiac death and cardiovascular outcomes in patients with coronary artery disease. The estimated absolute effects of intravascular imaging guided percutaneous coronary intervention showed a proportional relation with baseline risk, driven by the severity and complexity of coronary artery disease. SYSTEMATIC REVIEW REGISTRATION: PROSPERO CRD42023433568.


Subject(s)
Coronary Artery Disease , Drug-Eluting Stents , Myocardial Infarction , Percutaneous Coronary Intervention , Thrombosis , Humans , Coronary Angiography , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/therapy , Coronary Artery Disease/complications , Risk Factors , Myocardial Infarction/etiology , Thrombosis/etiology , Percutaneous Coronary Intervention/adverse effects , Death , Treatment Outcome
16.
JACC Case Rep ; 22: 101973, 2023 Sep 20.
Article in English | MEDLINE | ID: mdl-37790767

ABSTRACT

A 59-year-old male patient with history of rheumatic heart disease with 3 previous surgical aortic valve replacements with the last one being homograft followed by transcatheter aortic valve implantation in failed homograft presented with severe aortic regurgitation and cardiogenic shock requiring urgent TAV-in-TAV-in homograft. (Level of Difficulty: Advanced.).

17.
Am J Cardiol ; 207: 470-478, 2023 11 15.
Article in English | MEDLINE | ID: mdl-37844404

ABSTRACT

Intracoronary imaging has become an important tool in the treatment of complex lesions with percutaneous coronary intervention (PCI). This retrospective cohort study identified 1,118,475 patients with PCI from the Nationwide Readmissions Database from 2017 to 2019. Intravascular ultrasound (IVUS) and optical coherence tomography (OCT) were identified with appropriate International Classification of Diseases, Tenth Revision codes. The primary outcome was major adverse cardiac events. The secondary outcomes include net adverse clinical events (NACEs), all-cause mortality, myocardial infarction (MI) readmission, admission for stroke, and emergency revascularization. The multivariate Cox proportional hazard regression was used to adjust for demographic and co-morbid confounders. Of 1,118,475 PCIs, 86,140 (7.7%) used IVUS guidance and 5,617 (0.5%) used OCT guidance. The median follow-up time was 184 days. The primary outcome of major adverse cardiac events was significantly lower for the IVUS (6.5% vs 7.6%; hazard ratio [HR] 0.89, 95% confidence interval [CI] 0.86 to 0.91, p <0.001) and OCT (4.4% vs 7.6%; HR 0.69, 95% CI 0.61 to 0.79, p <0.001) groups. IVUS was associated with significantly lower rates of NACEs (8.4% vs 9.4%; HR 0.92, 95% CI 0.89 to 0.94, p <0.001), all-cause mortality (3.5% vs 4.3%; HR 0.85, 95% CI 0.82 to 0.88, p <0.001), readmission for MI (2.7% vs 3.0%; HR 0.95, 95% CI 0.91 to 0.99, p = 0.012), and admission for stroke (0.5% vs 0.6%; HR 0.86, 95% CI 0.78 to 0.95, p = 0.002). OCT was associated with significantly lower rates of NACEs (6.6% vs 9.4%; HR 0.81, 95% CI 0.73 to 0.89, p <0.001) and all-cause mortality (1.8% vs 4.3%; HR 0.51, 95% CI 0.42 to 0.63, p <0.001). Emergency revascularization was not significantly different with IVUS guidance. Readmission for MI, stroke, and emergency revascularization were not significantly different with OCT guidance. A subgroup analysis of patients with ST-elevation MI and non-ST-elevation MI showed similar results. In conclusion, the use of IVUS and OCT guidance with PCI were associated with significantly lower rates of morbidity and mortality in real-world practice.


Subject(s)
Coronary Artery Disease , Myocardial Infarction , Percutaneous Coronary Intervention , Stroke , Humans , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/surgery , Tomography, Optical Coherence , Coronary Angiography/methods , Percutaneous Coronary Intervention/methods , Retrospective Studies , Treatment Outcome , Ultrasonography, Interventional/methods , Stroke/etiology
18.
J Am Heart Assoc ; 12(19): e031118, 2023 10 03.
Article in English | MEDLINE | ID: mdl-37753800

ABSTRACT

Background The clinical significance of mitral annular calcification (MAC) in patients undergoing mitral transcatheter edge-to-edge repair is not well understood. There is limited evidence regarding the feasibility, durability of repair, and the prognostic value of MAC in this population. We sought to examine the prognostic value of MAC, its severity, and its impact on procedural success and durability of mitral transcatheter edge-to-edge repair. Methods and Results We reviewed the records of 280 patients with moderate-severe or severe mitral regurgitation who underwent mitral transcatheter edge-to-edge repair with MitraClip from March 2014 to March 2022. The primary end point was cumulative survival at 1 year. Independent factors associated with the primary end point were identified using multivariable Cox regression. Among 280 patients included in the final analysis, 249 had none/mild MAC, and 31 had moderate/severe MAC. Median follow-up was 23.1 months (interquartile range: 11.1-40.4). Procedural success was comparable in the MAC and non-MAC groups (92.6% versus 91.4%, P=0.79) with similar rates of residual mitral regurgitation ≤2 at 1 year (86.7% versus 93.2%, P=0.55). Moderate/severe MAC was associated with less improvement in New York Heart Association III/IV at 30 days when compared with none/mild MAC (45.8% versus 14.3%, P=0.001). The moderate/severe MAC group had lower cumulative 1-year survival (56.8% versus 80.0%, hazard ratio [HR], 1.98 [95% CI, 1.27-3.10], P=0.002). Moderate/severe MAC and Society of Thoracic Surgeons predicted risk of mortality for mitral valve repair were independently associated with the primary end point (HR, 2.20 [1.10-4.41], P=0.02; and HR, 1.014 [1.006-1.078], P=0.02, respectively). Conclusions Mitral TEER is a safe and feasible intervention in selected patients with significant MAC and associated with similar mitral regurgitation reduction at 1 year compared with patients with none/mild MAC. Patients with moderate/severe MAC had a high 1-year mortality and less improvement in their symptoms after TEER.


Subject(s)
Calcinosis , Heart Valve Diseases , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Humans , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/complications , Feasibility Studies , Heart Valve Prosthesis Implantation/methods , Treatment Outcome , Heart Valve Diseases/surgery , Calcinosis/diagnostic imaging , Calcinosis/surgery , Calcinosis/complications , Cardiac Catheterization/methods
19.
JACC Case Rep ; 18: 101916, 2023 Jul 19.
Article in English | MEDLINE | ID: mdl-37545690

ABSTRACT

Subaortic stenosis secondary to subaortic membrane is the second most common form of left ventricular outflow tract obstruction. We present the case of a 70-year-old male patient who presented with a 6-week history of progressive signs of heart failure. Multimodality imaging was required to confirm the presence of a subaortic membrane. (Level of Difficulty: Beginner.).

20.
JACC Cardiovasc Interv ; 16(13): 1626-1635, 2023 07 10.
Article in English | MEDLINE | ID: mdl-37438029

ABSTRACT

BACKGROUND: The latest-generation Evolut FX TAVR system (Medtronic) offers several potential design improvements over its predecessors, but early reported experience has been limited. OBJECTIVES: This study sought to report our multicenter, limited market release, first-in-human experience of transcatheter aortic valve replacement (TAVR) with the Evolut FX system and compare it with a single-center PRO+ (Medtronic) experience. METHODS: From June 27 to September 16, 2022, 226 consecutive patients from 9 US centers underwent transfemoral TAVR with the Evolut FX system for native aortic stenosis (89.4%) or prosthetic valve degeneration (10.6%). Commissural alignment was defined as 0° to 30° between native and FX commissures. Patient, anatomical, and procedural characteristics were retrospectively reviewed, and 30-day clinical and echocardiographic outcomes per Valve Academic Research Consortium-3 definitions were reported. RESULTS: Of 226 patients, 34.1% were low risk, 4% had a bicuspid valve, and 11.5% had a horizontal root (≥60°). Direct Inline sheath (Medtronic) was used in 67.6% and Lunderquist stiff wire (Cook Medical) in 35.4% of cases. Optimal hat marker orientation during deployment was achieved in 98.4%, with commissural alignment in 96.5%. At 30 days, 14.3% mild, 0.9% moderate, and no severe paravalvular leak were observed. Compared with the Evolut PRO+ experience from 1 center, FX had a more symmetrical implantation with shallower depth at the left coronary cusp (P < 0.001), fewer device recaptures (26.1% vs 39.5%; P = 0.004), and improved commissural alignment (96.5% vs 80.2%; P < 0.001). CONCLUSIONS: The Evolut FX system demonstrated favorable 30-day outcomes with a significant improvement over PRO+ in achieving commissural alignment, fewer device recaptures, and more symmetrical implantation. These features may benefit younger patients undergoing TAVR with the supra-annular, self-expanding valve, where lifetime management would be important.


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Retrospective Studies , Treatment Outcome , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Catheters
SELECTION OF CITATIONS
SEARCH DETAIL
...