Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Isr Med Assoc J ; 15(12): 753-7, 2013 Dec.
Article in English | MEDLINE | ID: mdl-24449979

ABSTRACT

BACKGROUND: Coronary slow flow phenomenon (CSFP) is a functional and structural disease that is diagnosed by coronary angiogram. OBJECTIVES: To evaluate the possible association between CSFP and small artery elasticity in an effort to understand the pathogenesis of CSFP. METHODS: The study population comprised 12 patients with normal coronary arteries and CSFP and 12 with normal coronary arteries without CSFP. We measured conjugated diene formation at 234 nm during low density lipoprotein (LDL) oxidation, as well as platelet aggregation. We estimated, noninvasively, arterial elasticity parameters. Mann-Whitney nonparametric test was used to compare differences between the groups. Data are presented as mean +/- standard deviation. RESULTS: Waist circumference was 99.2 +/- 8.8 cm and 114.9 +/- 10.5 cm in the normal flow and CSFP groups, respectively (P = 0.003). Four patients in the CSFP group and one in the normal flow group had type 2 diabetes. Area under the curve in the oral glucose tolerance test was 22% higher in the CSFP than in the normal group (P = 0.04). There was no difference in systolic and diastolic blood pressure, plasma concentrations of total cholesterol, triglycerides, high density lipoprotein, LDL and platelet aggregation parameters between the groups. Lag time required until initiation of LDL oxidation in the presence of CuSO4 was 17% longer (P = 0.02) and homocysteine fasting plasma concentration was 81% lower (P = 0.05) in the normal flow group. Large artery elasticity was the same in both groups. Small artery elasticity was 5 +/- 1.5 ml/mmHg x 100 in normal flow subjects and 6.1 +/- 1.9 ml/mmHg x 100 in the CSFP patients (P = 0.02). CONCLUSIONS: Patients with CSFP had more metabolic derangements. Arterial stiffness was not increased in CSFP.


Subject(s)
Coronary Vessels/physiopathology , No-Reflow Phenomenon , Obesity , Adult , Area Under Curve , Blood Pressure/physiology , Coronary Angiography/methods , Elasticity Imaging Techniques/methods , Female , Glucose Tolerance Test/methods , Humans , Lipoproteins, LDL/metabolism , Male , Middle Aged , No-Reflow Phenomenon/diagnosis , No-Reflow Phenomenon/metabolism , No-Reflow Phenomenon/physiopathology , Obesity/metabolism , Obesity/physiopathology , Platelet Aggregation/physiology , Statistics as Topic
2.
Catheter Cardiovasc Interv ; 71(2): 264-7, 2008 Feb 01.
Article in English | MEDLINE | ID: mdl-18327846

ABSTRACT

PURPOSE: To describe a new technique for distal protection during stenting of a bifurcated renal artery using two simultaneous filter devices. CASE REPORT: A 70-year-old patient underwent angiography of a single functional kidney. Severe proximal, nonostial narrowing of an early bifurcated renal artery was found. Two AngioGuard filter protection devices were placed, one in each branch. A balloon mounted stent was advanced over both wires simultaneously till they reached divergence point, expanded fully, and the protection devices were retrieved. No complications were observed and the final result was good. CONCLUSION: The concomitant use of two protection devices is feasible in a particular anatomy context.


Subject(s)
Catheterization/methods , Renal Artery Obstruction/therapy , Stents , Thromboembolism/prevention & control , Aged , Androstenols , Filtration/instrumentation , Humans , Male , Renal Artery/anatomy & histology
3.
J Invasive Cardiol ; 19(12): E363-5, 2007 Dec.
Article in English | MEDLINE | ID: mdl-18180528

ABSTRACT

The inability to cross tortuous, calcified or previously stented segments with an angioplasty balloon or coronary stent remains one of the frequent causes of the procedural failure. Numerous techniques have been developed to facilitate stent delivery in this situation: buddy wire, balloon deflection and use of specially designed guidewires. We report a case in which an ACE(R) fixed-wire balloon dilatation catheter was used as a "buddy", combining the best properties of different techniques in one device.


Subject(s)
Angioplasty, Balloon, Coronary/instrumentation , Myocardial Infarction/therapy , Aged , Coronary Angiography , Equipment Design , Follow-Up Studies , Humans , Male , Myocardial Infarction/diagnostic imaging
SELECTION OF CITATIONS
SEARCH DETAIL
...