Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Artif Organs ; 45(5): 524-527, 2021 May.
Article in English | MEDLINE | ID: mdl-33184841

ABSTRACT

We report the case of a 12-year old female patient with Friedreich's ataxia and diabetes mellitus. Due to a progressive multiorgan failure, a veno-arterial extracorporeal membrane oxygenation was implanted through the axillary vessels. However, due to a lack of ejection and severe dilatation of the left ventricle, an Impella 2.5 was implanted. Due to the small diameter of the femoral arteries, we performed a trans-aortic implantation through a median sternotomy via a Dacron tube graft. We report on the procedure and perioperative outcome.


Subject(s)
Extracorporeal Membrane Oxygenation/methods , Friedreich Ataxia/therapy , Heart-Assist Devices , Multiple Organ Failure/therapy , Prosthesis Implantation/methods , Child , Extracorporeal Membrane Oxygenation/instrumentation , Female , Friedreich Ataxia/complications , Friedreich Ataxia/genetics , Humans , Multiple Organ Failure/genetics , Prosthesis Implantation/instrumentation , Treatment Outcome
2.
Perfusion ; 35(7): 621-625, 2020 10.
Article in English | MEDLINE | ID: mdl-31960747

ABSTRACT

INTRODUCTION: Aortic arch reconstruction surgery represents a challenge for the medical personnel involved in treatment. Along the years, the perfusion strategies for aortic arch reconstruction have evolved from deep hypothermic cardiac arrest to antegrade cerebral perfusion with moderate hypothermia, and recently to a combined cerebral and lower body perfusion with moderate hypothermia. To achieve a lower body perfusion, several cannulation strategies have been described. In this study, we investigated the feasibility of utilizing an arterial sheath introduced in the femoral artery to achieve an effective lower body perfusion. METHODS: We included patients who underwent an aortic arch reconstruction surgery with a lower body perfusion, from January 2017 to June 2019. To achieve a lower body perfusion, a three-way stopcock was connected to the arterial line, where one end was connected to the central cannulation for cerebral perfusion and the other to an arterial sheath that was introduced through the femoral artery. A total of 25 patients were included. Peri- and postoperative lactate and creatinine levels and signs of malperfusion were recorded. RESULTS: During the reperfusion phase, after selective perfusion ended none of the patients showed a significant increase in lactate, creatinine, and liver enzyme levels. After 24 hours, there were no signs of an acute kidney injury, femoral vessel injury, or limb malperfusion. CONCLUSION: These findings show that a sufficient lower body perfusion through an arterial sheath placed in the femoral artery for aortic arch reconstruction can be achieved. This approach caused no complications related to the arterial sheath during the early postoperative period and is an easy way to maintain perfusion of systemic organs.


Subject(s)
Aorta, Thoracic/surgery , Lower Extremity/blood supply , Perfusion/methods , Female , Humans , Infant , Infant, Newborn , Male , Retrospective Studies
3.
Heart Lung Vessel ; 7(2): 151-158, 2015.
Article in English | MEDLINE | ID: mdl-26157741

ABSTRACT

INTRODUCTION: Right ventricular failure remains a major cause of mortality during acute pulmonary embolism. Right ventricular function can be assessed with transesophageal echocardiography. However, due to the complex right ventricular anatomy, only a few echocardiographic parameters are reliable and easily obtainable intraoperatively. Tricuspid annular plane systolic excursion is a validated parameter of global right ventricular function. METHODS: Data from 81 patients with acute pulmonary embolus undergoing pulmonary embolectomy were evaluated. Transesophageal echocardiography derived parameters of right ventricular function were obtained and compared to tricuspid annular plane systolic excursion measurements. Patients were then divided into two groups (TAPSE < 18 mm and ≥18 mm). RESULTS: The patient population consisted of 46 males and 35 females, mean age 61.0 ± 12.9 years. Patients in the TAPSE <18 mm group had significantly larger diastolic (p=0.0015) and systolic (p=0.0031) right ventricular diameters, lower right ventricular fractional area change  (p=0.0065) and greater degrees of tricuspid regurgitation (p=0.0001) compared to patients with TAPSE ≥18 mm. In addition, all patients who needed intraoperative cardiopulmonary resuscitation (11/81) or died intraoperatively (8/81) belonged to the TAPSE <18 mm group. Logistic regression analysis confirmed TAPSE <18 mm as an independent risk factor for intraoperative cardiopulmonary resuscitation and death. CONCLUSIONS: Transesophageal echocardiography derived TAPSE is easily obtainable and correlates well with other standardized parameters of right ventricular function. TAPSE <18 mm is an independent predictor of intraoperative cardiopulmonary resuscitation and death in patients undergoing emergent pulmonary embolectomy.

SELECTION OF CITATIONS
SEARCH DETAIL
...