Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 41
Filter
1.
Article in English | MEDLINE | ID: mdl-38967777

ABSTRACT

BACKGROUND: In recent years, the indication for cementless short stem total hip arthroplasty (THA) has been widened to elderly patients as they might profit by the advantages of the short-curved implant design as well. Therefore, this study was conducted to evaluate the clinical and radiological outcome of a cementless short stem in elderly patients (≥ 75 years) compared to a young control group (≤ 60 years). METHODS: A retrospective cohort of 316 THAs performed between 2014 and 2017 was prospectively examined. In all patients a cementless, curved short stem and press-fit cup (Fitmore® stem; Allofit®/-S cup; both ZimmerBiomet, Warsaw, IN, USA) were implanted via a minimally-invasive anterolateral approach. Clinical and radiological outcome as well as rate of complications and revision were assessed. RESULTS: In total, 292 patients have been included for analysis of complications and revisions (Øfollow-up: 4.5 years) and 208 patients for clinical and radiological outcome (Øfollow-up: 4.4 years). Complication rate was significantly increased in elderly patients (13.7% vs. 5.8%, p = 0.023), while the revision rate was increased without statistical significance (5.2% vs. 2.2%, p = 0.169). Periprosthetic fractures occurred significantly higher in the elderly patients (5.2% vs. 0.7%; p = 0.026). Both groups showed a comparable clinical outcome in the Harris Hip Score (93.7 vs. 91.9; p = 0.224), Oxford Hip Score (44.5 vs. 43.7; p = 0.350), Forgotten Joint Score (81.7 vs. 81.5; p = 0.952) and WOMAC (7.4 vs. 9.3; p = 0.334). CONCLUSION: Cementless short stem total hip arthroplasty shows a comparable clinical and radiological outcome in patients over 75 years of age compared to younger patients under 60 years of age. However, cementless shorts stem THA shows an increased rate of overall complications and periprosthetic fractures in elderly patients over 75 years of age. Cemented fixation of the femoral component should be considered in patients over 75 years of age. LEVEL OF EVIDENCE: III Case-controlled study. TRIAL REGISTRATION: Observational study without need for trial registration due to ICMJE criteria.

2.
J Pediatr Orthop ; 44(3): 135-140, 2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38073187

ABSTRACT

INTRODUCTION: The Pavlik harness is a commonly used treatment for developmental dysplasia of the hip (DDH) of types IIc or worse, based on the Graf classification. This study aimed to assess the long-term follow-up outcomes after treating DDH with the Pavlik harness. METHODS: Between 1995 and 2006, ultrasound screening was conducted on 7372 newborns within the first days of life. Among them, 203 dysplastic hips in 152 patients, whose sonograms were Graf type IIc or worse, were treated with Pavlik harness. Treatment was discontinued if the measurement indicated Graf type Ia/b. More than 20 years later (mean: 20.46 y), patients were invited for clinical evaluation (Oxford Hips Score, Schulthess Hip Score, Harris Hip Score) and radiologic examination (center-edge angle according to Wiberg and the Severis classification, the rate of roofing of the femoral head via the Reimers migration percentage, and the Sharp angle). RESULTS: Of the 152 patients, 60 (39.5%) participants with 80 (39.4%) affected hips (57.7% type IIc, 7.9% type D, and 15.6% type IIIa/b) were reexamined. The average follow-up duration was 20.5 years, with a maximum of 25.9 years. According to the Severin's classification, only 2 (3.77%) patients, each with one affected hip, showed slight residual dysplasia. The Reimer's migration percentage indicated an average of almost 90% canopy cover in the patient collective studied. No avascular necrosis was found, and the Sharp angle showed an average of almost 38 degrees. Only 4 participants with each one affected hip showed residual dysplasia according to the Sharp angle. The clinical results were quite satisfying, as none of the patients experienced hip pain that significantly limited their everyday activities or sports engagement, requiring medical attention before this study.Conclusions:Conservative therapy of DDH (Graf type IIc, D, III) with the Pavlik harness has demonstrated very good therapeutic success and a very low rate of residual dysplasia (2.81%). Both the radiologic and clinical outcomes were highly satisfactory. LEVEL OF EVIDENCE: Level IV.


Subject(s)
Developmental Dysplasia of the Hip , Hip Dislocation, Congenital , Humans , Infant, Newborn , Infant , Hip Joint/diagnostic imaging , Hip Dislocation, Congenital/therapy , Orthotic Devices , Retrospective Studies , Treatment Outcome , Ultrasonography
3.
Arch Orthop Trauma Surg ; 143(3): 1193-1202, 2023 Mar.
Article in English | MEDLINE | ID: mdl-34687350

ABSTRACT

BACKGROUND: Pelvic and femoral osteotomies have been effective methods to treat developmental dysplasia of the hip (DDH), neurogenic dislocation of the hip (NDH), and Legg-Calvé-Perthes disease (LCPD). The aim of this study was to evaluate the mid-term results after hip reconstruction in children with DDH, NDH, and LCPD. METHODS: In a retrospective study, X-rays of 73 children (2-19 years) with DDH, NDH, and LCPD were measured before, 3 months, and at final follow-up (FU) after hip reconstructive surgery (open reduction, and femoral and/or pelvic osteotomy ± soft-tissue procedures between 2008 and 2018). Measurement of hip geometry included acetabular index (AI), center-edge angle (CE), and Reimers migration index (RMI). Mean follow-up time at final FU was 4.9 years. P value was set P < 0.05. RESULTS: After surgery (femoral osteotomy: 84 hips, Salter innominate osteotomy: 21 hips, Pemberton osteotomy: 30 hips, open reduction: 28 hips, Chiari osteotomy: 4 hips, and soft-tissue release: 24 hips), hip geometry parameters improved significantly. Nevertheless, at final FU, there was deterioration in hip geometry with femoral head lateralization (RMI) compared to the data at 3 months after surgery (RMI: preop/3 months/final FU: 40.6 ± 16.1%/6.1 ± 9.0/15.4 ± 16.0%; CE: 11.3° ± 20.0°/30.2° ± 9.5°/27.9 ± 15.4°; AI: 28.8° ± 9.6°/19.1° ± 7.6°/18.3 ± 7.6°). Sub-group analysis did not show differences concerning the progression of RMI in DDH, NDH, and LCPD at final FU. Regardless of basic disease, the lateralization was observed in all three groups (DDH, NDH, and LCPD) and statistically significant comparing X-rays 3 months postoperatively to maximum follow-up (DDH; NDH; LCPD: 2.7 ± 6.8%/7.6 ± 10.1%; 13.7 ± 15.3%/22.8 ± 19.8%; 1.7 ± 4.1%/14.9 ± 11.3%). Additional soft-tissue release techniques in patients with DDH or NDH did not show postoperative differences with statistical significance. Concerning surgical techniques, a connection between the lower RMI and the procedure of osteotomy of the ilium was found. In 25 patients, (34%) complications were observed: superficial skin lesions in 8, deep skin lesions in 3, contraction of adductors in 3, subluxation in 2, dislocations of the cast in 2, osteonecrosis of the femoral head in 2 cases, reluxation in 1, infection of the implanted plate in 1, compliance problem in 1, delayed bone healing in 1, and contraction of knee flexors in 1 case. DISCUSSION: The basic results of this study show a significant improvement of hip geometry at a follow-up of 4.9 years and prove findings of previously published literature. Moreover, the study was able to show a progression of RMI in all patient groups, which have undergone reconstructive surgery, despite basic hip geometry data (AI, CE angle) did not change. Those findings were independent from underlying pathology. Complications were counted in 34% of the patients and involved all known adverse events after hip reconstructive surgery. This makes clear why annual follow-up checks are needed not to miss the right indication for revision surgery. CLINICAL RELEVANCE: Evidence level: Level IV, case series. TRIAL REGISTRATION: This manuscript is part of a prospective randomized clinical trial, registered in the German Clinical Trials Register DRKS-ID: DRKS00016861.


Subject(s)
Hip Dislocation, Congenital , Hip Dislocation , Legg-Calve-Perthes Disease , Surgery, Plastic , Humans , Child , Legg-Calve-Perthes Disease/surgery , Cohort Studies , Follow-Up Studies , Retrospective Studies , Prospective Studies , Treatment Outcome , Hip Dislocation/surgery , Acetabulum/surgery , Hip Joint/surgery , Hip Dislocation, Congenital/surgery
4.
Arch Orthop Trauma Surg ; 143(2): 773-784, 2023 Feb.
Article in English | MEDLINE | ID: mdl-34524486

ABSTRACT

INTRODUCTION: Foot drop is a disorder that impairs walking and leads to tripping and falling. Tendon transfer (e.g., tibialis posterior tendon) is a typical secondary procedure in foot drop treatment. The purpose of this systematic review was to identify the most common tendon transfer techniques for treating foot drop and to analyze the reported functional outcomes. Furthermore, it was of interest if the type of surgical technique affects the functional outcome. METHODS: A PubMed and MEDLINE literature search was performed according to PRISMA guidelines. The search terms used were ("tendon transfer" OR "tendon transposition") AND ("foot drop" OR "peroneal neuropathies"). Any study published before January 2020 was considered for inclusion. No case reports or reviews were included. Common outcome measures (Stanmore score, AOFAS, FAAM, AFO use, patient satisfaction and active ankle dorsiflexion) were evaluated. The quality of the included studies was assessed using the Coleman Methodology Score. RESULTS: Of the 125 reviewed publications, 37 met the inclusion criteria. 42 cohorts were analyzed. The frequently reported tendon transfer technique was the tibialis posterior tendon transfer through the interosseus membrane. The most used fixation technique was tendon on tendon fixation; however in recent years, a tendon to bone fixation has gained popularity. There was an increase in Stanmore scores and AOFAS postoperatively and a decrease of AFO use postoperatively observed. CONCLUSIONS: Due to various outcome measures and lack of preoperative assessment in the included studies, a meta-analysis of the pooled results was not possible. Nevertheless, the findings of this study show that tendon transfer increases mobility and self-independency leading to patient satisfaction. The choice of the surgical technique does not affect the outcome. A prospective collection of patient data and standardized outcome measures will be important to further analyze the efficacy of tendon transfer techniques.


Subject(s)
Peroneal Neuropathies , Tendon Transfer , Humans , Patient Satisfaction , Peroneal Neuropathies/surgery , Prospective Studies , Tendon Transfer/methods , Tendons , Treatment Outcome
5.
Children (Basel) ; 9(10)2022 Sep 20.
Article in English | MEDLINE | ID: mdl-36291363

ABSTRACT

Background: Distal femoral extension and shortening osteotomy (DFESO) seems to be an effective method for the treatment of flexed knee gait in children with cerebral palsy. Nevertheless, studies investigating the mid- and long-term outcomes after such procedures are lacking in the literature. Therefore, the purpose of this study was to assess the mid-term outcomes regarding sagittal plane kinematics of the knee after DFESO with or without concomitant patella advancement. Furthermore, an evaluation of the postoperative course and possible recurrence of flexed knee gait was planned. Methods: In a prospective observational study, 19 patients (28 limbs; mean age 11.8 years (6.7-16.0 years)) were examined using 3-D gait analysis and clinical exam before (E0) and at a mean of 38 months (E2: 24-55 months) after surgery. Fifteen patients (22 limbs) had an additional first postoperative gait analysis (E1) after a mean of 14 (10-20) months after surgery. In these patients, the postoperative changes between the short-term and mid-term gait analyses were evaluated. Results: DFESO led to a significant decrease in flexed knee gait with an improvement in sagittal plane kinematics during the stance phase. In addition, a slightly increased anterior pelvic tilt was observed at E1, and we found a tendency towards stiff knee gait with a decrease in mean knee flexion in swing at E2. Conclusions: DFESO led to a significant improvement in flexed knee gait in children with cerebral palsy. The therapeutic effect seems to be lasting on mid-term follow-up with a slight overall tendency to recurrence.

6.
Medicina (Kaunas) ; 58(2)2022 Feb 14.
Article in English | MEDLINE | ID: mdl-35208611

ABSTRACT

Background and Objectives: Due to inferior survival rates compared to hip and knee arthroplasty, total ankle arthroplasty (TAA) was previously mainly recommended for older and less active patients. However, given the encouraging survival rates and clinical outcomes of modern generations of TAA, some authors have also advocated TAA in young patients. Thus, the aim of this study was to evaluate age related reoperation, revision and survival rates of third-generation mobile-bearing TAAs. Materials andMethods: In this retrospective study, 224 consecutive TAA patients with a minimum follow up (FU) of 2 years were analyzed. Patients were retrospectively assigned to two study groups (Group A: age < 50 years; Group B: age ≥ 50 years). Revision was defined as secondary surgery with prothesis component removal, while reoperation was defined as a non-revisional secondary surgery involving the ankle. Results: After a mean FU of 7.1 ± 3.2 years, the reoperation rate (Group A: 22.2%; Group B: 5.3%; p = 0.003) and revision rate (Group A: 36.1%; Group B: 13.8%; p = 0.003) were higher within Group A. An age of under 50 years at time of surgery was associated with higher reoperation (odds ratio (OR): 6.54 (95% CI: 1.96-21.8); p = 0.002) and revision rates (OR: 3.13 (95% CI: 1.22-8.04); p = 0.018). Overall, lower patient age was associated with higher reoperation (p = 0.009) and revision rates (p = 0.001). Conclusions: The ideal indication for TAA remains controversial, especially regarding patient age. The findings of this study show high reoperation and revision rates in patients aged under 50 years at time of surgery. Therefore, the outcomes of this study suggest that the indication for TAA in young patients should be considered very carefully and that the association between low patient age and high reoperation rate should be disclosed to all eligible patients.


Subject(s)
Ankle , Arthroplasty, Replacement, Ankle , Aged , Ankle Joint , Arthroplasty, Replacement, Ankle/adverse effects , Humans , Middle Aged , Reoperation , Retrospective Studies , Treatment Outcome
7.
Arch Orthop Trauma Surg ; 142(7): 1661-1668, 2022 Jul.
Article in English | MEDLINE | ID: mdl-34169356

ABSTRACT

PURPOSE: Digital templating shows reliable accuracy for straight stem systems. In recent years, the implantation of short stems through minimally invasive approaches has gained more popularity. Minimally invasive approaches (MIS) show the risk of undersizing femoral components. Therefore, we questioned the planning adherence for a curved short stem and a bi-hemispherical acetabular cup implanted through an anterolateral MIS approach. METHODS: A consecutive series of 964 hips (index surgery between 2014 and 2019) with Fitmore® curved short stem and Allofit/-S® acetabular cup (both ZimmerBiomet Inc, Warsaw, IN) were included. Preoperative digital templating was conducted anterior-posterior (AP) digital radiographs of the hip using mediCAD® version 5.1 (Hectec GmbH, Altdorf, Germany). The templates of acetabular and femoral components (offset option and stem size) were retrospectively evaluated for general adherence, and according to sex, BMI and planner's experience. RESULTS: Planning adherence for the exact offset option was 70.6 and 21.6% for exact offset option and stem size. Adherence for acetabular cup ± 1 size was 74.8%. A significant difference between male and female patients for the offset option could be found (p = 0.03, z = -2983). In 22.5% of male patients, an offset option one size higher and in 12.3% of female patients an offset option one size smaller than templated was used intraoperatively CONCLUSION: Digital templating for the Fitmore® stem in cementless THA with a minimally invasive anterolateral approach shows comparable planning adherence to the existing literature for this cementless short stem. However, a lower planning adherence was detected compared to conventional straight stem systems. In male patients, the femoral offset is frequently undersized and in female patients frequently oversized compared to the preoperative plan. Surgeons should be aware of this difficulty in digital templating for Fitmore® hip stem.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Female , Hip/surgery , Hip Joint/diagnostic imaging , Hip Joint/surgery , Humans , Male , Retrospective Studies , Sex Factors
8.
Arch Orthop Trauma Surg ; 142(5): 871-878, 2022 May.
Article in English | MEDLINE | ID: mdl-34076711

ABSTRACT

PURPOSE: Minimally invasive surgery using short stems in total hip arthroplasty gained more popularity. The differences in change of hip offset and implant positioning in minimally invasive approaches are not fully known. Therefore, this study was conducted to evaluate the difference in reconstruction of hip offset and implant positioning in direct anterior approach (DAA) and minimally invasive anterolateral approach (AL MIS). METHODS: A single surgeon series of 117 hips (117 patients; mean age 65.54 years ± 11.47; index surgery 2014-2018) were included and allocated into two groups: group A (DAA) with 70 hips and Group B (AL MIS) with 47 patients operated. In both groups the same type of cementless curved short hip stem and press fit cup was used. RESULTS: Both groups showed an equal statistically significant increase of femoral (p < 0.001) and decrease of acetabular offset (p < 0.001). Between both groups no statistically significant difference in offset reconstruction, leg length difference or implant positioning could be found. Leg length increased in both groups significantly and leg length discrepancy showed no difference (group A: - 0.06 mm; group B: 1.11 mm; p < 0.001). A comparable number of cups were positioned outside the target zone regarding cup anteversion. CONCLUSION: The usage of a curved short stem shows an equal reconstruction of femoro-acetabular offset, leg length and implant positioning in both MIS approaches. The results of this study show comparable results to the existing literature regarding change of offset and restoration of leg length. Malposition of the acetabular component regarding anteversion poses a risk.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Acetabulum/surgery , Aged , Arthroplasty, Replacement, Hip/methods , Humans , Leg Length Inequality/surgery
9.
J Clin Med ; 10(18)2021 Sep 13.
Article in English | MEDLINE | ID: mdl-34575239

ABSTRACT

BACKGROUND: Equinus is a common foot deformity in patients with cerebral palsy (CP). However, its prevalence is scarcely reported in the literature. Therefore, we conducted this review to estimate the prevalence of equinus foot in CP. METHODS: Eight databases were searched. Our primary outcome was the prevalence of equinus foot in CP patients. Subgroup analysis was conducted based on study design, the laterality of CP, and whether equinus foot was defined or not. RESULTS: The prevalence of equinus foot in CP was 93% (95% CI: 71-99). The prevalence was 99% (95% CI: 55-100), 96% (95% CI: 57-100), and 65% (95% CI: 37-86) in unilateral, both, and bilateral CP, respectively. Based on study design, equinus foot prevalence was 92% (95% CI: 34-100) in case series and 62% (95% CI: 47-74) in cohort studies. Four studies reported definition criteria for equinus foot, with a pooled prevalence rate of equinus foot of 99% (95% CI: 36-100) compared to a rate of 89% (95% CI: 59-98) among studies that lacked a definition criterion. CONCLUSIONS: This is the first meta-analysis to address the prevalence of equinus foot in CP patients. Although its prevalence is very high, our findings should be interpreted with caution due to the presence of multiple limitations, such as the lack of standardized definition criteria for equinus foot, the inappropriate study design, the wide confidence interval of equinus foot rate, and the small number of studies investigating it as a primary outcome.

10.
EFORT Open Rev ; 6(12): 1132-1139, 2021 Dec 10.
Article in English | MEDLINE | ID: mdl-35839087

ABSTRACT

Bioabsorbable and biodegradable implants offer new possibilities in orthopaedic and trauma surgery. As soon as the initial stability of the degradable implants has reached the qualities of conventional materials, new devices may find usage in younger and more demanding patients. Residual conventional osteosynthetic material or the necessity to remove metal increasingly seems to be more of an adverse event than daily practice in forefoot surgery. Nevertheless, some drawbacks need to be discussed. Recent literature screened for the use of bioabsorbable and biodegradable materials in forefoot surgery, available implants and indications in forefoot surgery were analysed and summarized. Apart from common indications in forefoot surgery, points of interest were the type of biomaterial, the process of biodegradation and biointegration, and possible adverse events. Materials were comprehensively discussed for each indication based on the available literature. Polylactide, polyglycoside and polydioxanone are considered safe and sufficiently stable for use in forefoot surgery. Low complication rates (e.g. 0.7% for pin fixation in hallux deformities) are given. Magnesium implants suffered from an extensive corrosive process in the first generation but now seem to be safe in forefoot surgery and offer good options compared with conventional titanium screws, especially in procedures of the first ray. Allograft bone has proven feasibility in small case series, but still lacks larger or randomized clinical trials. The first results are promising. Bioresorbable and osseointegrating devices offer attractive new possibilities for surgeons and patients. Despite all the known advantages, the difficulties and possible complications must not be forgotten, such as soft tissue reactions, unwanted osteolysis and a lower primary mechanical load capacity.

11.
Materials (Basel) ; 13(3)2020 Jan 24.
Article in English | MEDLINE | ID: mdl-31991553

ABSTRACT

(1) Background: The objective of the present study was to review the clinical and radiological results of a small-head, MoM bearing in primary THA and to determine blood metal ion levels at long-term follow-up. (2) Methods: We retrospectively evaluated the clinical and radiological results of 284 small-diameter, MoM 28-mm Metasul THA at a mean follow-up of 14.5 years, and measured blood metal ion concentrations in 174 of these patients. (3) Results: After 14 years, survival free for revision due to any reason was 94%. Proximal femoral osteolysis was seen in 23% of hips, and MRI demonstrated ARMD in 27 of the 66 investigated hips (41%). Mean cobalt, chromium, and titanium ion concentrations were 0.82 µg/L (range 0.22-4.45), 1.51 µg/L (0.04-22.69), and 2.68 µg/L (0.26-19.56) in patients with unilateral THA, and 2.59 µg/L (0.43-24.75), 2.50 µg/L (0.26-16.75), and 3.76 µg/L (0.67-19.77), respectively in patients with bilateral THA. Twenty-nine percent of patients showed cobalt or chromium ion levels > 2 µg/L. (4) Conclusions: Despite good clinical long-term results, increased blood metal ion levels (cobalt or chromium > 2 µg/L) were found in approximately one-third of asymptomatic patients, and proximal femoral osteolysis and ARMD were frequently seen in this cohort. Blood metal ion analysis appears helpful in the long-term follow-up of these patients in order to identify individuals at risk. In accordance with contemporary consensus statements, symptomatic patients with elevated metal ion levels and/or progressive osteolysis should be considered for additional CT or MARS MRI to determine the extent of soft tissue affection prior to revision surgery. Further studies are necessary to investigate the clinical relevance of ARMD in asymptomatic patients with small-head, MoM THA.

12.
J Clin Med ; 8(10)2019 Oct 11.
Article in English | MEDLINE | ID: mdl-31614496

ABSTRACT

As unilateral cerebral palsy represents a complex disorder, gait classification is difficult. Knowledge of the most frequent gait patterns and functional impairment is crucial for proper decision-making. This study analyzes the prevalence of gait patterns as well as the relation of different gait patterns and the Gross Motor Function Classification System (GMFCS). Eighty-nine patients were classified retrospectively using the GMFCS, the classification of Winters, Gage, and Hicks (WGH), and Sutherland et al. The distribution of GMFCS levels among the different gait patterns was analyzed using Chi-squared test. The most common subtypes were GMFCS level I, WGH type I, and recurvatum knee. Seventeen percent (WGH) and 59% (Sutherland) of the patients did not match any criteria. Applying both classifications complementarily reduced the number of unclassified patients significantly. There was no significant difference concerning the distribution of GMFCS levels or age among the different gait patterns. A combined use of various classification systems is beneficial for proper decision-making. Unclassified patients seem to be a heterogeneous subgroup concerning functional impairment. There is a need of further characterization of the unclassifiable gait patterns and the caused functional impairment. Instrumented gait analysis remains the gold standard and should be broadly used for future studies and in clinical practice.

13.
Proc Inst Mech Eng H ; 233(11): 1175-1182, 2019 Nov.
Article in English | MEDLINE | ID: mdl-31545137

ABSTRACT

Femoral neck prostheses have been developed for the treatment of osteoarthritis in young and active patients. The concept combines a bone-conserving and minimal invasive technique with proximal load transferring by metaphyseal anchoring, which results in a more physiological loading pattern. However, little is known about the morphology of periprosthetic fractures. Thus, the aim of this study was to describe fracture patterns and to determine patient-specific factors favoring periprosthetic fracture. This study was performed as a biomechanical experimental study using 10 fresh frozen femora and 10 Silent-Hip femoral neck implants (DePuy International Ltd., Leeds, UK). In order to simulate physiological loading, a static muscle reconstruction (abductor muscles and iliotibial band) and a dynamic simulation of the gait cycle were applied. During biomechanical testing (50% and 100% of normal weight-bearing), three periprosthetic fractures with two different morphologies occurred. The first pattern corresponds to an abrupt breakaway. The second type was of spiral configuration extending to the diaphyseal region and emerging from an initial fissure. Specimen-specific factors favoring periprosthetic fracture were body mass index and varus angle of the implant. Periprosthetic fractures may extend to the subtrochanteric/diaphyseal region and may be of spiral configuration. According to the finding of this study, body mass index and varus/valgus position of the implant are important factors influencing the risk of periprosthetic fractures. Furthermore, partial weight-bearing as part of the postoperative regimen may be favorable.


Subject(s)
Femur Neck/injuries , Hip Prosthesis , Materials Testing , Mechanical Phenomena , Periprosthetic Fractures , Aged , Aged, 80 and over , Biomechanical Phenomena , Female , Humans , Male , Middle Aged
14.
Dev Med Child Neurol ; 61(7): 791-797, 2019 07.
Article in English | MEDLINE | ID: mdl-30474110

ABSTRACT

AIM: To evaluate short-term (1y postoperatively; E1) and long-term (at least 4y postoperatively; E2) changes in hamstring muscle-tendon length (MTL) and lengthening velocity after hamstring lengthening in children with bilateral cerebral palsy (CP). METHOD: Three-dimensional gait analysis was performed in 19 children (16 males, 3 females; 36 limbs; mean age at surgery 9y [SD 3y]; range 6-10y) with flexed knee gait, preoperative ankle dorsiflexion lower than 20 degrees, and CP before bilateral hamstring lengthening (E0), at E1 and E2. Hamstring MTL (normalized by leg length) and velocity were assessed via OpenSim software. RESULTS: MTL increased from E0 to E1 (p=0.004) and decreased from E1 to E2 (p<0.020). Hamstring lengthening velocity did not change. In the subgroup with short, not slow hamstrings, the increase in MTL was maintained at E2. INTERPRETATION: Hamstring lengthening is an efficient procedure to lengthen short and/or slow hamstrings short-term. The desired outcome with maintenance of the postoperative changes in hamstring MTL is only achieved for preoperatively short, not slow hamstrings. WHAT THIS PAPER ADDS: Surgical hamstring lengthening can be confirmed via musculoskeletal modelling in OpenSim software. Surgical hamstring lengthening in cerebral palsy does not change hamstring lengthening velocity. Short, not slow hamstrings present a long-lasting muscle-tendon length (MTL) increase after hamstring lengthening. Changes in MTL after hamstring lengthening cannot be maintained for slow hamstrings. MTL does not change after hamstring lengthening for neither short nor slow hamstrings.


CAMBIOS MUSCULARES A LARGO PLAZO DESPUÉS DEL ALARGAMIENTO DE LOS ISQUIOTIBIALES EN NIÑOS CON PARÁLISIS CEREBRAL BILATERAL: OBJETIVO: Evaluar los cambios a corto plazo (un año después de la operación; E1) y a largo plazo (al menos cuatro años después de la operación; E2) de la longitud del tendón muscular de los isquiotibiales (LT) y la velocidad de alargamiento después del estiramiento en niños con parálisis cerebral bilateral (PC). MÉTODO: Se realizó un análisis tridimensional de la marcha en 19 niños (16 varones, tres mujeres; 36 extremidades; edad media en la cirugía 9 años [DS 3 años]; rango 6-10 años) con la marcha en flexión de la rodilla, dorsiflexión preoperatoria del tobillo inferior a 20 grados, antes del alargamiento bilateral de los isquiotibiales (E0), en E1 y E2. El LT de los músculos isquiotibiales (normalizado por la longitud de la pierna) y la velocidad fueron evaluadas mediante el OpenSim. RESULTADOS: El LT aumentó de E0 a E1 (p = 0,004) y disminuyó de E1 a E2 (p<0,020). La velocidad de alargamiento de los isquiotibiales no cambió. En el subgrupo con isquiotibiales cortos, pero no lentos, el aumento de la LT se mantuvo en E2. INTERPRETACIÓN: El alargamiento de los isquiotibiales es un procedimiento eficiente para los isquiotibiales cortos y/o lentos a corto plazo. El resultado deseado con el mantenimiento de los cambios postoperatorios en la longitud de los isquiotibiales solo se logra para los isquiotibiales cortos no lentos antes de la operación.


ALTERAÇÕES MUSCULARES A LONGO PRAZO APÓS ALONGAMENTO DE ISQUIOTIBIAIS EM CRIANÇAS COM PARALISIA CEREBRAL BILATERAL: OBJETIVO: Avaliar a curto (um ano de pós-operatório; E1) e longo prazo (no mínimo quatro anos de pós-operatório; E2) alterações no comprimento do tendão do músculo (CTM) isquiotibial e a velocidade de estiramento após alongamento do isquiotibial em crianças com paralisia cerebral bilateral (PC). MÉTODO: Foi realizada a análise tridimensional da marcha em 19 crianças (16 meninos, três meninas; 36 membros; média de idade de cirurgia de 9 anos [DP 3 anos]; variação de 6-10 anos) com marcha com flexão de joelho, ângulo de dorsiflexão de tornozelo menor que 20o no pré-operatório, e PC antes do alongamento bilateral dos isquiotibiais (E0), em E1 e E2. CTM dos isquiotibiais (normalizado pelo comprimento da perna) e a velocidade foram avaliados pelo OpenSim. RESULTADOS: CTM aumentou de E0 para E1 (p=0,004) e diminuiu de E1 para E2 (p<0,020). A velocidade de estiramento do isquiotibial não mudou. No subgrupo com isquiotibial encurtado e não lento, o aumento no CTM foi mantido em E2. INTERPRETAÇÃO: O alongamento do músculo isquiotibial é um procedimento eficiente para alongar isquitotibiais encurtados e/ou lentos a curto prazo. O resultado desejado com a manutenção das alterações no pós-operatório no CTM do isquiotibial é atingida somente para isquiotibial curto e não lento no pré-operatório.


Subject(s)
Cerebral Palsy/physiopathology , Cerebral Palsy/surgery , Hamstring Tendons/physiopathology , Hamstring Tendons/surgery , Biomechanical Phenomena , Child , Computer Simulation , Female , Gait Analysis , Humans , Male , Models, Biological , Retrospective Studies , Time Factors , Treatment Outcome
15.
Dev Med Child Neurol ; 61(3): 322-328, 2019 03.
Article in English | MEDLINE | ID: mdl-30255540

ABSTRACT

AIM: To evaluate the influence of supracondylar femoral derotation osteotomy (FDO) on hip abduction muscle force and frontal hip moments in children with bilateral cerebral palsy. METHOD: For this retrospective cohort study 79 children (36 females, 43 males; mean age at surgery 11y [SD 3y]; range 4-17y) with bilateral cerebral palsy and preoperatively and 1-year postoperatively documented frontal hip moments who received supracondylar FDO in 134 limbs were included. The control group consisted of eight children (two females, six males; mean age 11y [SD 4y]; range 5-17y) who received single-event multi-level surgery without FDO. RESULTS: Hip joint impulse (p<0.001) and the first peak of frontal hip moments (p=0.003) increased, whereas the second peak decreased (p<0.001) from preoperatively to postoperatively. Hip abductor strength improved (p=0.001) from preoperatively to postoperatively. INTERPRETATION: Despite the compensatory mechanism, frontal hip moments are decreased preoperatively. Supracondylar FDO results in increased frontal hip moments. Changes in anteversion directly influence hip kinetics, although no direct change of the proximal bony geometry is performed. WHAT THIS PAPER ADDS: Internal rotation gait cannot fully restore the frontal hip moment. Supracondylar femoral derotation osteotomy (FDO) influences frontal hip kinetics in children with bilateral cerebral palsy. Supracondylar FDO changes the curve progression of frontal hip moments. Supracondylar FDO restores the hip abductor moment arm. Supracondylar FDO leads to an increase in hip abductor muscle force.


Subject(s)
Cerebral Palsy/physiopathology , Femur/surgery , Gait Disorders, Neurologic/surgery , Hip Joint/physiopathology , Osteotomy , Range of Motion, Articular/physiology , Adolescent , Cerebral Palsy/complications , Child , Child, Preschool , Cohort Studies , Female , Gait Disorders, Neurologic/etiology , Gait Disorders, Neurologic/physiopathology , Humans , Male , Muscle Strength/physiology , Treatment Outcome , Weight-Bearing/physiology
16.
Knee ; 25(4): 609-616, 2018 Aug.
Article in English | MEDLINE | ID: mdl-29792279

ABSTRACT

BACKGROUND: In uncemented total hip arthroplasty (THA), low bone mineral density (BMD) is associated with aseptic loosening. BMD is usually assessed via dual-energy X-ray absorptiometry (DXA) or quantitative computed tomography, which takes time and exposes patients to radiation. Due to its low risk profile, intraoperative measurement of the trabecular stability might be a useful alternative to DXA. METHODS: In 24 human femora, BMD was analysed using DXA at the femoral necks and the knees. Performing the standard Oxford Unicompartmental Knee Arthroplasty (OUKA) implantation procedure, a wingblade (DensiProbe) coupled to a torque probe was used to evaluate the trabecular peak torque. The standard procedure was modified: before the completion of the central peg drill hole, the DensiProbe was inserted into the pre-drilled hole and then turned until a loss of resistance was achieved. The obtained data was then correlated with BMD at the femoral neck as well as the knee. RESULTS: In all tested regions, a higher peak torque was observed in correlation with a higher BMD. CONCLUSIONS: As demonstrated, the DensiProbe can be a helpful tool to assess the bone quality intraoperatively in OUKA. It can be a valuable decision guidance when faced with choosing between a cemented and a cementless implant. Due to the fact that the central peg hole of the OUKA can be used for the procedure, no additional risk for the patient exists, while the additional work for the surgeon is minimal.


Subject(s)
Absorptiometry, Photon/methods , Arthroplasty, Replacement, Knee/methods , Bone Density/physiology , Knee Joint/surgery , Aged , Aged, 80 and over , Bone Cements , Cadaver , Decision Making , Female , Femur/diagnostic imaging , Femur/surgery , Humans , Knee Prosthesis , Male , Middle Aged , Torque
17.
Clin Biomech (Bristol, Avon) ; 55: 23-27, 2018 06.
Article in English | MEDLINE | ID: mdl-29649670

ABSTRACT

BACKGROUND: The twin peg femoral component was introduced for the cemented Oxford unicondylar knee to increase implant stability. The aim of this experimental study was to investigate the influence of the twin peg design on femoral interface temperature and maximum load to failure in comparison to the single peg design. METHODS: In this experimental study medial Oxford unicompartmental knee arthroplasty was performed in 12 pairs of fresh-frozen human knees. A cemented femoral single peg component was implanted on the one side (group A) and a cemented twin peg component on the other side (group B). Cement interface temperature was continuously monitored during the procedure. Maximum tensile forces of the femoral components were measured by pull-out tests. FINDINGS: Maximum femoral interface temperatures did not reach critical values for heat necrosis of the bone in group A (mean 28.4, SD 1.2 °C) or group B (mean 27.6, SD 0.5 °C). The maximum load to failure was significantly higher in the twin peg group (mean 3628.41, SD 650.92 N) compared to the single peg group (mean 2979, SD 781 N) (P = 0.016). INTERPRETATION: Our experiments showed higher load to failure for the twin peg design compared to the single peg design without raising the risk of heat necrosis at the interfacial bone. The twin peg component offers a save alternative to the single peg component in a cadaveric setting.


Subject(s)
Arthroplasty, Replacement, Knee/instrumentation , Arthroplasty, Replacement, Knee/methods , Femur/surgery , Knee Prosthesis , Prosthesis Design , Temperature , Aged , Biomechanical Phenomena , Bone Cements , Cadaver , Female , Femur/physiology , Humans , Knee Joint/surgery , Male , Materials Testing , Middle Aged , Osteoarthritis, Knee/surgery , Tensile Strength
18.
Foot Ankle Int ; 39(7): 812-820, 2018 07.
Article in English | MEDLINE | ID: mdl-29606023

ABSTRACT

BACKGROUND: Equinus foot deformity constitutes a common gait disorder in ambulatory adults with bilateral spastic cerebral palsy (BSCP). The outcome after intramuscular aponeurotic lengthening in the context of single-event multilevel surgery (SEMLS) in adulthood has not been investigated. METHODS: We followed a group of 31 ambulatory adults with BSCP and equinus who underwent SEMLS including gastrocnemius-soleus intramuscular aponeurotic recession or Achilles tendon lengthening. All patients were analyzed preoperatively and at least 1 year (mean follow-up period: 1.6 years) postoperatively by clinical examination and 3-dimensional instrumented gait analysis including the Gait Profile Score (GPS). RESULTS: Clinical examination showed no significant improvement of ankle dorsiflexion ( P = .5) and an unchanged plantarflexion ( P = .7) with knee extended but a significant postoperative reduction of spasticity in the calf muscle ( P = .0001) as measured by clinical examination following the modified Ashworth scale. Significant improvement of mean ankle dorsiflexion in stance and swing ( P = .0001) was found. The GPS decreased and improved significantly (15.9 ± 4.6 to 11.4 ± 3.1; P = .0001). Persistence of equinus and calcaneal gait indicating under- and overcorrection at follow-up was found in 1 patient (3%), respectively. CONCLUSION: Intramuscular gastrocnemius-soleus aponeurotic recession is part of multilevel surgery corrected equinus deformity in adults. The increase in muscle length led to significant improvement of kinetic and kinematic parameters during walking without a loss of muscle strength and push-off capacity. The risk of overcorrection after equinus correction in adults with BSCP was found to be relatively low. LEVEL OF EVIDENCE: Level IV, retrospective case series.


Subject(s)
Cerebral Palsy/surgery , Equinus Deformity/surgery , Gait , Muscle, Skeletal/surgery , Adolescent , Adult , Cerebral Palsy/physiopathology , Female , Humans , Leg/surgery , Male , Muscle Spasticity , Range of Motion, Articular , Retrospective Studies , Young Adult
19.
Dev Med Child Neurol ; 60(8): 833-838, 2018 08.
Article in English | MEDLINE | ID: mdl-29536527

ABSTRACT

AIM: Flexed knee gait can be treated with distal femoral extension osteotomy (DFEO) and additional patellar tendon advancement (PTA) in children with cerebral palsy (CP). This study assesses changes in hamstring muscle tendon length (MTL) and velocity after DFEO (+PTA). METHOD: Nineteen children (mean age 13y [standard deviation 3y] at surgery) with CP and flexed knee gait who were treated with DFEO (15 limbs) or DFEO+PTA (10 limbs) were retrospectively included in this study. Gait analyses were performed preoperatively (E0), 1 year postoperatively (E1), and for 10 limbs additionally 2 to 5 years postoperatively (E2). Hamstring MTL and velocities were assessed at all examination dates using OpenSim. RESULTS: Hamstring MTL and velocity did not change significantly over time. From E0 to E1, knee flexion in stance improved for both DFEO and DFEO+PTA (p<0.05), knee flexion in swing only improved after DFEO+PTA (p<0.05). The improved knee flexion in stance and swing was maintained at E2. INTERPRETATION: DFEO led to a significant improvement in knee kinematics at E1 which was maintained at E2. DFEO seems to prevent recurrent hamstring tightness but does not lead to lengthened or fastened hamstrings. WHAT THIS PAPER ADDS: Distal femoral extension osteotomy (DFEO) does not change hamstring muscle tendon length. DFEO does not change hamstring lengthening velocity. DFEO leads to a significant improvement in knee kinematics. Changes in knee kinematics after DFEO can be maintained at mid-term. DFEO seems to prevent recurrent hamstring tightness.


Subject(s)
Cerebral Palsy/surgery , Femur/surgery , Gait/physiology , Hamstring Tendons , Knee/physiopathology , Osteotomy/methods , Outcome Assessment, Health Care , Patellar Ligament , Adolescent , Biomechanical Phenomena , Child , Female , Follow-Up Studies , Hamstring Tendons/pathology , Hamstring Tendons/physiopathology , Humans , Male , Retrospective Studies
20.
J Arthroplasty ; 33(6): 1838-1843, 2018 06.
Article in English | MEDLINE | ID: mdl-29510951

ABSTRACT

BACKGROUND: Revision total hip arthroplasty frequently faces challenges associated with deficient bone stock. Porous metal implants were developed to meet the challenge, but require rapid osseointegration for ultimate success. This study aims to assess relative motion as an indicator for primary stability and osseointegration of two different titanium cups each combined with a titanium augment. METHODS: In 14 cadaver hemipelvises, 2 types of titanium acetabular cups, a traditional sintered-bead cup (POROCOAT Acetabular Cup [PAC]) and a newer porous-coated cup (GRIPTION Acetabular Cup [GAC]) each associated with a porous augment, were subjected to 3-dimensional varying loads, replicating 30% of loads experienced during normal gait. Relative motion was measured at the cup/bone, augment/bone, and cup/augment interfaces. RESULTS: Only at the cup/bone interface was there a statistically significant difference in relative motion between the traditional PAC and the newer GAC, with PAC showing less relative motion (P = .0037). Bone mineral density (BMD) had a significant effect on relative motion (P = .0019) at the cup/bone interface of both cup types, with low BMD specimens showing more relative motion. CONCLUSION: Both cup types combined with augments displayed minimal relative motion that was within the accepted range thought to allow osseointegration, although the traditional surface proved superior to the newer surface. This difference was more pronounced at low BMD, with the well-established PAC cup displaying less relative motion than the more porous GAC cup, consistent with better osseointegration than the more porous cup. This suggests that the more porous implant may be less advantageous than traditional PAC cups, particularly in cases with poorer bone stock.


Subject(s)
Acetabulum/surgery , Arthroplasty, Replacement, Hip/instrumentation , Hip Prosthesis , Osseointegration , Prosthesis Design , Aged , Aged, 80 and over , Bone Density , Humans , Metals , Middle Aged , Porosity , Reoperation , Titanium
SELECTION OF CITATIONS
SEARCH DETAIL
...