Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
JACC Clin Electrophysiol ; 5(12): 1459-1472, 2019 12.
Article in English | MEDLINE | ID: mdl-31857047

ABSTRACT

OBJECTIVES: A new electroanatomic mapping system (Rhythmia, Boston Scientific, Marlborough, Massachusetts) using a 64-electrode mapping basket is now available; we systematically assessed its use in complex congenital heart disease (CHD). BACKGROUND: The incidence of atrial arrhythmias post-surgery for CHD is high. Catheter ablation has emerged as an effective treatment, but is hampered by limitations in the mapping system's ability to accurately define the tachycardia circuit. METHODS: Mapping and ablation data of 61 patients with CHD (35 males, age 45 ± 14 years) from 8 tertiary centers were reviewed. RESULTS: Causes were as follows: Transposition of Great Arteries (atrial switch) (n = 7); univentricular physiology (Fontans) (n = 8); Tetralogy of Fallot (n = 10); atrial septal defect (ASD) repair (n = 15); tricuspid valve (TV) anomalies (n = 10); and other (n = 11). The total number of atrial arrhythmias was 86. Circuits were predominantly around the tricuspid valve (n = 37), atriotomy scar (n = 10), or ASD patch (n = 4). Although the majority of peri-tricuspid circuits were cavo-tricuspid-isthmus dependent (n = 30), they could follow a complex route between the annulus and septal resection, ASD patch, coronary sinus, or atriotomy. Immediate ablation success was achieved in all but 2 cases; with follow-up of 12 ± 8 months, 7 patients had recurrence. CONCLUSIONS: We demonstrate the feasibility of the basket catheter for mapping complex CHD arrhythmias, including with transbaffle and transhepatic access. Although the circuits often involve predictable anatomic landmarks, the precise critical isthmus is often difficult to predict empirically. Ultra-high-density mapping enables elucidation of circuits in this complex anatomy and allows successful treatment at the isthmus with a minimal lesion set.


Subject(s)
Catheter Ablation/methods , Electrophysiologic Techniques, Cardiac/methods , Heart Defects, Congenital , Tachycardia , Adult , Aged , Catheter Ablation/instrumentation , Electrophysiologic Techniques, Cardiac/instrumentation , Equipment Design , Female , Heart/diagnostic imaging , Heart/physiopathology , Heart Defects, Congenital/complications , Heart Defects, Congenital/diagnostic imaging , Humans , Male , Middle Aged , Prospective Studies , Tachycardia/diagnostic imaging , Tachycardia/etiology , Tachycardia/physiopathology
2.
Int J Cardiol ; 270: 143-148, 2018 Nov 01.
Article in English | MEDLINE | ID: mdl-29895424

ABSTRACT

BACKGROUND: Electrocardiographic mapping (ECM) expresses electrical substrate through magnitude and direction of the activation delay vector (ADV). We investigated to what extent the response to cardiac resynchronization therapy (CRT) is determined by baseline ADV and by ADV modification through CRT and optimization of left ventricular (LV) pacing site. METHODS: ECM was performed in 79 heart failure patients (4 RBBB, 12 QRS < 120 ms, 23 non-specific conduction delay [NICD] and 40 left bundle branch block [LBBB]). 67 patients (QRS ≥ 120 ms) underwent CRT implantation and in 26 patients multiple LV pacing site optimization was performed. ADV was calculated from locations/depolarization times of 2000 virtual epicardial electrodes derived from ECM. Acute response was defined as ≥10% LVdP/dtmax increase, chronic response by composite clinical score at 6 months. RESULTS: During intrinsic conduction, ADV direction was similar in patients with QRS < 120 ms, NICD and LBBB, pointing towards the LV free wall, while ADV magnitude was larger in LBBB (117 ±â€¯25 ms) than in NICD (70 ±â€¯29 ms, P < 0.05) and QRS < 120 ms (52 ±â€¯14 ms, P < 0.05). Intrinsic ADV accurately predicted the acute (AUC = 0.93) and chronic (AUC = 0.90) response to CRT. ADV change by CRT only moderately predicted response (highest AUC = 0.76). LV pacing site optimization had limited effects: +3 ±â€¯4% LVdP/dtmax when compared to conventional basolateral LV pacing. CONCLUSION: The baseline electrical substrate, adequately measured by ADV amplitude, strongly determines acute and chronic CRT response, while the extent of its modification by conventional CRT or by varying LV pacing sites has limited effects.


Subject(s)
Body Surface Potential Mapping/methods , Body Surface Potential Mapping/trends , Cardiac Resynchronization Therapy/methods , Cardiac Resynchronization Therapy/trends , Heart Failure/physiopathology , Heart Failure/therapy , Aged , Aged, 80 and over , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/physiopathology , Arrhythmias, Cardiac/therapy , Bundle-Branch Block/diagnosis , Bundle-Branch Block/physiopathology , Bundle-Branch Block/therapy , Electrocardiography/methods , Electrocardiography/trends , Female , Heart Failure/diagnosis , Humans , Male , Middle Aged , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...