Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Intensive Care Med ; 38(1): 120-7, 2012 Jan.
Article in English | MEDLINE | ID: mdl-22105962

ABSTRACT

PURPOSE: Mechanical complications during assisted ventilation can evolve due to worsening lung disease or problems in airway management. These complications affect lung compliance or airway resistance, which in turn affect the chest wall dynamics. The objective of this study was to explore the utility of continuous monitoring of the symmetry and dynamics of chest wall motion in the early detection of complications during mechanical ventilation. METHODS: The local tidal displacement (TDi) values of each side of the chest and epigastrium were measured by three miniature motion sensors in 18 rabbits. The TDi responses to changes in peak inspiratory pressure (n = 7), induction of one-lung intubation (n = 7), and slowly progressing pneumothorax (PTX) (n = 6) were monitored in parallel with conventional respiratory (SpO(2), EtCO(2), pressure and flow) and hemodynamic (HR and BP) indices. PTX was induced by injecting air into the pleural space at a rate of 1 mL/min. RESULTS: A strong correlation (R(2) = 0.99) with a slope close to unity (0.94) was observed between percent change in tidal volume and in TDi. One-lung ventilation was identified by conspicuous asymmetry development between left and right TDis. These indices provided significantly early detection of uneven ventilation during slowly developing PTX (within 12.9 ± 6.6 min of onset, p = 0.02) almost 1 h before the SpO(2) dropped (77.3 ± 27.4 min, p = 0.02). Decreases in TDi of the affected side paralleled the progression of PTX. CONCLUSIONS: Monitoring the local TDi is a sensitive method for detecting changes in tidal volume and enables early detection of developing asymmetric ventilation.


Subject(s)
Respiration, Artificial/adverse effects , Respiratory Insufficiency/diagnosis , Thoracic Wall/physiology , Animals , Early Diagnosis , Lung Compliance/physiology , Male , Monitoring, Physiologic/instrumentation , Monitoring, Physiologic/methods , Rabbits , Respiratory Mechanics/physiology
2.
Intensive Care Med ; 37(7): 1174-81, 2011 Jul.
Article in English | MEDLINE | ID: mdl-21528388

ABSTRACT

INTRODUCTION: Monitoring ventilated infants is difficult during high-frequency oscillatory ventilation (HFOV). This study tested the possible causes of hypoxemic episodes using a new method for monitoring chest wall movement during HFOV in newborn infants. METHODS: Three miniature motion sensors were attached to both sides of the chest and to the epigastrium to measure the local tidal displacement (TDi) at each site. A >20% change in TDi was defined as deviation from baseline. RESULTS: Eight premature infants (postmenstrual age 30.6 ± 2.6 weeks) were monitored during 10 sessions (32.6 h) that included 21 hypoxemic events. Three types of such events were recognized: decrease in TDi that preceded hypoxemia (n = 11), simultaneous decrease in TDi and SpO2 (n = 6), and decrease in SpO(2) without changes in TDi (n = 4). In the first group, decreases in TDi were detected 22.4 ± 18.7 min before hypoxemia, and were due to airway obstruction by secretions or decline in lung compliance. The second group resulted from apnea or severe abdominal contractions. In the third group, hypoxia appeared following a decrease in FiO2. CONCLUSIONS: Monitoring TDi may enable early recognition of deteriorating ventilation during HFOV that eventually leads to hypoxemia. In about half of cases, hypoxemia is not due to slowly deteriorating ventilation.


Subject(s)
High-Frequency Ventilation/adverse effects , Hypoxia/physiopathology , Monitoring, Physiologic/methods , Respiratory Mechanics/physiology , Thoracic Wall/physiology , Female , Humans , Infant, Newborn , Infant, Premature , Male