Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 23
Filter
1.
Cancers (Basel) ; 16(12)2024 Jun 13.
Article in English | MEDLINE | ID: mdl-38927921

ABSTRACT

Cancers can manifest large variations in tumor phenotypes due to genetic and microenvironmental factors, which has motivated the development of quantitative radiomics-based image analysis with the aim to robustly classify tumor phenotypes in vivo. Positron emission tomography (PET) imaging can be particularly helpful in elucidating the metabolic profiles of tumors. However, the relatively low resolution, high noise, and limited PET data availability make it difficult to study the relationship between the microenvironment properties and metabolic tumor phenotype as seen on the images. Most of previously proposed digital PET phantoms of tumors are static, have an over-simplified morphology, and lack the link to cellular biology that ultimately governs the tumor evolution. In this work, we propose a novel method to investigate the relationship between microscopic tumor parameters and PET image characteristics based on the computational simulation of tumor growth. We use a hybrid, multiscale, stochastic mathematical model of cellular metabolism and proliferation to generate simulated cross-sections of tumors in vascularized normal tissue on a microscopic level. The generated longitudinal tumor growth sequences are converted to PET images with realistic resolution and noise. By changing the biological parameters of the model, such as the blood vessel density and conditions for necrosis, distinct tumor phenotypes can be obtained. The simulated cellular maps were compared to real histology slides of SiHa and WiDr xenografts imaged with Hoechst 33342 and pimonidazole. As an example application of the proposed method, we simulated six tumor phenotypes that contain various amounts of hypoxic and necrotic regions induced by a lack of oxygen and glucose, including phenotypes that are distinct on the microscopic level but visually similar in PET images. We computed 22 standardized Haralick texture features for each phenotype, and identified the features that could best discriminate the phenotypes with varying image noise levels. We demonstrated that "cluster shade" and "difference entropy" are the most effective and noise-resilient features for microscopic phenotype discrimination. Longitudinal analysis of the simulated tumor growth showed that radiomics analysis can be beneficial even in small lesions with a diameter of 3.5-4 resolution units, corresponding to 8.7-10.0 mm in modern PET scanners. Certain radiomics features were shown to change non-monotonically with tumor growth, which has implications for feature selection for tracking disease progression and therapy response.

2.
Cureus ; 16(4): e59260, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38813339

ABSTRACT

Objectives Contralateral hypertrophy of non-irradiated liver following Yttrium-90 (90Y) transarterial radioembolization (TARE) is increasingly recognized as an option to facilitate curative surgical resection in patients that would otherwise not be surgical candidates due to a small future liver remnant (FLR). This study aimed to investigate the correlation between patient features and liver hypertrophy and identify potential predictors for liver growth in patients with hepatocellular carcinoma (HCC) and portal vein tumor thrombus (PVTT) undergoing TARE. Methodology Twenty-three patients with HCC and PVTT were included. Contralateral liver hypertrophy was assessed at six months posttreatment based on CT or MRI imaging. Thirteen patient features were selected for statistical and prediction analysis. Univariate Spearman correlation and analysis of variance (ANOVA) tests were performed. Subsequently, four feature-selection methods based on multivariate analysis were used to improve model generalization performance. The selected features were applied to train linear regression models, with fivefold cross-validation to assess the performance of the predicted models. Results The ratio of disease-free target liver volume to spared liver volume and total liver volume showed the highest correlations with contralateral hypertrophy (P-values = 0.03 and 0.05, respectively). In three out of four feature-selection methods, the feature of disease-free target liver volume to total liver volume ratio was selected, having positive correlations with the outcome and suggesting that more hypertrophy may be expected when more volume of disease-free liver is irradiated. Conclusions Contralateral hypertrophy post-90Y TARE can be an option for facilitating surgical resection in patients with otherwise small FLR.

3.
Neuroimage Clin ; 42: 103600, 2024.
Article in English | MEDLINE | ID: mdl-38599001

ABSTRACT

Several genetic pathogenic variants increase the risk of Parkinson's disease (PD) with pathogenic variants in the leucine-rich repeat kinase 2 (LRRK2) gene being among the most common. A joint pattern analysis based on multi-set canonical correlation analysis (MCCA) was utilized to extract PD and LRRK2 pathogenic variant-specific spatial patterns in relation to healthy controls (HCs) from multi-tracer Positron Emission Tomography (PET) data. Spatial patterns were extracted for individual subject cohorts, as well as for pooled subject cohorts, to explore whether complementary spatial patterns of dopaminergic denervation are different in the asymptomatic and symptomatic stages of PD. The MCCA results are also compared to the traditional univariate analysis, which serves as a reference. We identified PD-induced spatial distribution alterations common to DAT and VMAT2 in both asymptomatic LRRK2 pathogenic variant carriers and PD subjects. The inclusion of HCs in the analysis demonstrated that the dominant common PD-induced pattern is related to an overall dopaminergic terminal density denervation, followed by asymmetry and rostro-caudal gradient with deficits in the less affected side still being the best marker of disease progression. The analysis was able to capture a trend towards PD-related patterns in the LRRK2 pathogenic variant carrier cohort with increasing age in line with the known increased risk of this patient cohort to develop PD as they age. The advantage of this method thus resides in its ability to identify not only regional differences in tracer binding between groups, but also common disease-related alterations in the spatial distribution patterns of tracer binding, thus potentially capturing more complex aspects of disease induced alterations.


Subject(s)
Leucine-Rich Repeat Serine-Threonine Protein Kinase-2 , Parkinson Disease , Positron-Emission Tomography , Humans , Parkinson Disease/genetics , Parkinson Disease/diagnostic imaging , Leucine-Rich Repeat Serine-Threonine Protein Kinase-2/genetics , Positron-Emission Tomography/methods , Middle Aged , Female , Male , Aged , Adult , Heterozygote , Brain/diagnostic imaging , Vesicular Monoamine Transport Proteins/genetics , Dopamine Plasma Membrane Transport Proteins/genetics
4.
Cancers (Basel) ; 16(6)2024 Mar 08.
Article in English | MEDLINE | ID: mdl-38539425

ABSTRACT

OBJECTIVES: Accurate outcome prediction is important for making informed clinical decisions in cancer treatment. In this study, we assessed the feasibility of using changes in radiomic features over time (Delta radiomics: absolute and relative) following chemotherapy, to predict relapse/progression and time to progression (TTP) of primary mediastinal large B-cell lymphoma (PMBCL) patients. MATERIAL AND METHODS: Given the lack of standard staging PET scans until 2011, only 31 out of 103 PMBCL patients in our retrospective study had both pre-treatment and end-of-treatment (EoT) scans. Consequently, our radiomics analysis focused on these 31 patients who underwent [18F]FDG PET-CT scans before and after R-CHOP chemotherapy. Expert manual lesion segmentation was conducted on their scans for delta radiomics analysis, along with an additional 19 EoT scans, totaling 50 segmented scans for single time point analysis. Radiomics features (on PET and CT), along with maximum and mean standardized uptake values (SUVmax and SUVmean), total metabolic tumor volume (TMTV), tumor dissemination (Dmax), total lesion glycolysis (TLG), and the area under the curve of cumulative standardized uptake value-volume histogram (AUC-CSH) were calculated. We additionally applied longitudinal analysis using radial mean intensity (RIM) changes. For prediction of relapse/progression, we utilized the individual coefficient approximation for risk estimation (ICARE) and machine learning (ML) techniques (K-Nearest Neighbor (KNN), Linear Discriminant Analysis (LDA), and Random Forest (RF)) including sequential feature selection (SFS) following correlation analysis for feature selection. For TTP, ICARE and CoxNet approaches were utilized. In all models, we used nested cross-validation (CV) (with 10 outer folds and 5 repetitions, along with 5 inner folds and 20 repetitions) after balancing the dataset using Synthetic Minority Oversampling TEchnique (SMOTE). RESULTS: To predict relapse/progression using Delta radiomics between the baseline (staging) and EoT scans, the best performances in terms of accuracy and F1 score (F1 score is the harmonic mean of precision and recall, where precision is the ratio of true positives to the sum of true positives and false positives, and recall is the ratio of true positives to the sum of true positives and false negatives) were achieved with ICARE (accuracy = 0.81 ± 0.15, F1 = 0.77 ± 0.18), RF (accuracy = 0.89 ± 0.04, F1 = 0.87 ± 0.04), and LDA (accuracy = 0.89 ± 0.03, F1 = 0.89 ± 0.03), that are higher compared to the predictive power achieved by using only EoT radiomics features. For the second category of our analysis, TTP prediction, the best performer was CoxNet (LASSO feature selection) with c-index = 0.67 ± 0.06 when using baseline + Delta features (inclusion of both baseline and Delta features). The TTP results via Delta radiomics were comparable to the use of radiomics features extracted from EoT scans for TTP analysis (c-index = 0.68 ± 0.09) using CoxNet (with SFS). The performance of Deauville Score (DS) for TTP was c-index = 0.66 ± 0.09 for n = 50 and 0.67 ± 03 for n = 31 cases when using EoT scans with no significant differences compared to the radiomics signature from either EoT scans or baseline + Delta features (p-value> 0.05). CONCLUSION: This work demonstrates the potential of Delta radiomics and the importance of using EoT scans to predict progression and TTP from PMBCL [18F]FDG PET-CT scans.

5.
Eur J Nucl Med Mol Imaging ; 51(7): 1937-1954, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38326655

ABSTRACT

PURPOSE: Total metabolic tumor volume (TMTV) segmentation has significant value enabling quantitative imaging biomarkers for lymphoma management. In this work, we tackle the challenging task of automated tumor delineation in lymphoma from PET/CT scans using a cascaded approach. METHODS: Our study included 1418 2-[18F]FDG PET/CT scans from four different centers. The dataset was divided into 900 scans for development/validation/testing phases and 518 for multi-center external testing. The former consisted of 450 lymphoma, lung cancer, and melanoma scans, along with 450 negative scans, while the latter consisted of lymphoma patients from different centers with diffuse large B cell, primary mediastinal large B cell, and classic Hodgkin lymphoma cases. Our approach involves resampling PET/CT images into different voxel sizes in the first step, followed by training multi-resolution 3D U-Nets on each resampled dataset using a fivefold cross-validation scheme. The models trained on different data splits were ensemble. After applying soft voting to the predicted masks, in the second step, we input the probability-averaged predictions, along with the input imaging data, into another 3D U-Net. Models were trained with semi-supervised loss. We additionally considered the effectiveness of using test time augmentation (TTA) to improve the segmentation performance after training. In addition to quantitative analysis including Dice score (DSC) and TMTV comparisons, the qualitative evaluation was also conducted by nuclear medicine physicians. RESULTS: Our cascaded soft-voting guided approach resulted in performance with an average DSC of 0.68 ± 0.12 for the internal test data from developmental dataset, and an average DSC of 0.66 ± 0.18 on the multi-site external data (n = 518), significantly outperforming (p < 0.001) state-of-the-art (SOTA) approaches including nnU-Net and SWIN UNETR. While TTA yielded enhanced performance gains for some of the comparator methods, its impact on our cascaded approach was found to be negligible (DSC: 0.66 ± 0.16). Our approach reliably quantified TMTV, with a correlation of 0.89 with the ground truth (p < 0.001). Furthermore, in terms of visual assessment, concordance between quantitative evaluations and clinician feedback was observed in the majority of cases. The average relative error (ARE) and the absolute error (AE) in TMTV prediction on external multi-centric dataset were ARE = 0.43 ± 0.54 and AE = 157.32 ± 378.12 (mL) for all the external test data (n = 518), and ARE = 0.30 ± 0.22 and AE = 82.05 ± 99.78 (mL) when the 10% outliers (n = 53) were excluded. CONCLUSION: TMTV-Net demonstrates strong performance and generalizability in TMTV segmentation across multi-site external datasets, encompassing various lymphoma subtypes. A negligible reduction of 2% in overall performance during testing on external data highlights robust model generalizability across different centers and cancer types, likely attributable to its training with resampled inputs. Our model is publicly available, allowing easy multi-site evaluation and generalizability analysis on datasets from different institutions.


Subject(s)
Image Processing, Computer-Assisted , Lymphoma , Positron Emission Tomography Computed Tomography , Tumor Burden , Humans , Positron Emission Tomography Computed Tomography/methods , Lymphoma/diagnostic imaging , Image Processing, Computer-Assisted/methods , Fluorodeoxyglucose F18 , Automation , Male , Female
6.
Med Phys ; 51(2): 1203-1216, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37544015

ABSTRACT

BACKGROUND: Prostate-specific membrane antigen (PSMA) PET imaging represents a valuable source of information reflecting disease stage, response rate, and treatment optimization options, particularly with PSMA radioligand therapy. Quantification of radiopharmaceutical uptake in healthy organs from PSMA images has the potential to minimize toxicity by extrapolation of the radiation dose delivery towards personalization of therapy. However, segmentation and quantification of uptake in organs requires labor-intensive organ delineations that are often not feasible in the clinic nor scalable for large clinical trials. PURPOSE: In this work we develop and test the PSMA Healthy organ segmentation network (PSMA-Hornet), a fully-automated deep neural net for simultaneous segmentation of 14 healthy organs representing the normal biodistribution of [18 F]DCFPyL on PET/CT images. We also propose a modified U-net architecture, a self-supervised pre-training method for PET/CT images, a multi-target Dice loss, and multi-target batch balancing to effectively train PSMA-Hornet and similar networks. METHODS: The study used manually-segmented [18 F]DCFPyL PET/CT images from 100 subjects, and 526 similar images without segmentations. The unsegmented images were used for self-supervised model pretraining. For supervised training, Monte-Carlo cross-validation was used to evaluate the network performance, with 85 subjects in each trial reserved for model training, 5 for validation, and 10 for testing. Image segmentation and quantification metrics were evaluated on the test folds with respect to manual segmentations by a nuclear medicine physician, and compared to inter-rater agreement. The model's segmentation performance was also evaluated on a separate set of 19 images with high tumor load. RESULTS: With our best model, the lowest mean Dice coefficient on the test set was 0.826 for the sublingual gland, and the highest was 0.964 for liver. The highest mean error in tracer uptake quantification was 13.9% in the sublingual gland. Self-supervised pretraining improved training convergence, train-to-test generalization, and segmentation quality. In addition, we found that a multi-target network produced significantly higher segmentation accuracy than single-organ networks. CONCLUSIONS: The developed network can be used to automatically obtain high-quality organ segmentations for PSMA image analysis tasks. It can be used to reproducibly extract imaging data, and holds promise for clinical applications such as personalized radiation dosimetry and improved radioligand therapy.


Subject(s)
Antigens, Surface , Glutamate Carboxypeptidase II , Prostatic Neoplasms , Animals , Humans , Male , Image Processing, Computer-Assisted/methods , Positron Emission Tomography Computed Tomography/methods , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/radiotherapy , Tissue Distribution
7.
Neuroimage Clin ; 36: 103246, 2022.
Article in English | MEDLINE | ID: mdl-36451352

ABSTRACT

Alterations in different aspects of dopamine processing may exhibit different progressive behaviours throughout the course of Parkinson's disease. We used a novel data-driven multivariate approach to quantify and compare spatiotemporal patterns related to different aspects of dopamine processing from cross-sectional Parkinson's subjects obtained with: 1) 69 [11C]±dihydrotetrabenazine (DTBZ) scans, most closely related to dopaminergic denervation; 2) 73 [11C]d-threo-methylphenidate (MP) scans, marker of dopamine transporter density; 3) 50 6-[18F]fluoro-l-DOPA (FD) scans, marker of dopamine synthesis and storage. The anterior-posterior gradient in the putamen was identified as the most salient feature associated with disease progression, however the temporal progression of the spatial gradient was different for the three tracers. The expression of the anterior-posterior gradient was the highest for FD at disease onset compared to that of DTBZ and MP (P = 0.018 and P = 0.047 respectively), but decreased faster (P = 0.006) compared to that of DTBZ. The gradient expression for MP was initially similar but decreased faster (P = 0.015) compared to that for DTBZ. These results reflected unique temporal behaviours of regulatory mechanisms related to dopamine synthesis (FD) and reuptake (MP). While the relative early disease upregulation of dopamine synthesis in the anterior putamen prevalent likely extends to approximately 10 years after symptom onset, the presumed downregulation of dopamine transporter density may play a compensatory role in the prodromal/earliest disease stages only.


Subject(s)
Methylphenidate , Parkinson Disease , Humans , Dopamine Plasma Membrane Transport Proteins/metabolism , Dopamine/metabolism , Parkinson Disease/diagnostic imaging , Parkinson Disease/metabolism , Cross-Sectional Studies , Tomography, X-Ray Computed , Positron-Emission Tomography/methods , Levodopa
8.
Comput Methods Programs Biomed ; 219: 106750, 2022 Jun.
Article in English | MEDLINE | ID: mdl-35381490

ABSTRACT

BACKGROUND AND OBJECTIVE: Radiomics and deep learning have emerged as two distinct approaches to medical image analysis. However, their relative expressive power remains largely unknown. Theoretically, hand-crafted radiomic features represent a mere subset of features that neural networks can approximate, thus making deep learning a more powerful approach. On the other hand, automated learning of hand-crafted features may require a prohibitively large number of training samples. Here we directly test the ability of convolutional neural networks (CNNs) to learn and predict the intensity, shape, and texture properties of tumors as defined by standardized radiomic features. METHODS: Conventional 2D and 3D CNN architectures with an increasing number of convolutional layers were trained to predict the values of 16 standardized radiomic features from real and synthetic PET images of tumors, and tested. In addition, several ImageNet-pretrained advanced networks were tested. A total of 4000 images were used for training, 500 for validation, and 500 for testing. RESULTS: Features quantifying size and intensity were predicted with high accuracy, while shape irregularity and heterogeneity features had very high prediction errors and generalized poorly. For example, mean normalized prediction error of tumor diameter with a 5-layer CNN was 4.23 ± 0.25, while the error for tumor sphericity was 15.64 ± 0.93. We additionally found that learning shape features required an order of magnitude more samples compared to intensity and size features. CONCLUSIONS: Our findings imply that CNNs trained to perform various image-based clinical tasks may generally under-utilize the shape and texture information that is more easily captured by radiomics. We speculate that to improve the CNN performance, shape and texture features can be computed explicitly and added as auxiliary variables to the networks, or supplied as synthetic inputs.


Subject(s)
Deep Learning , Neoplasms , Humans , Image Processing, Computer-Assisted/methods , Neoplasms/diagnostic imaging , Neural Networks, Computer
9.
EJNMMI Phys ; 9(1): 2, 2022 Jan 15.
Article in English | MEDLINE | ID: mdl-35032234

ABSTRACT

BACKGROUND: Positron emission tomography (PET) with prostate specific membrane antigen (PSMA) have shown superior performance in detecting metastatic prostate cancers. Relative to [18F]fluorodeoxyglucose ([18F]FDG) PET images, PSMA PET images tend to visualize significantly higher-contrast focal lesions. We aim to evaluate segmentation and reconstruction algorithms in this emerging context. Specifically, Bayesian or maximum a posteriori (MAP) image reconstruction, compared to standard ordered subsets expectation maximization (OSEM) reconstruction, has received significant interest for its potential to reach convergence with minimal noise amplifications. However, few phantom studies have evaluated the quantitative accuracy of such reconstructions for high contrast, small lesions (sub-10 mm) that are typically observed in PSMA images. In this study, we cast 3 mm-16-mm spheres using epoxy resin infused with a long half-life positron emitter (sodium-22; 22Na) to simulate prostate cancer metastasis. The anthropomorphic Probe-IQ phantom, which features a liver, bladder, lungs, and ureters, was used to model relevant anatomy. Dynamic PET acquisitions were acquired and images were reconstructed with OSEM (varying subsets and iterations) and BSREM (varying ß parameters), and the effects on lesion quantitation were evaluated. RESULTS: The 22Na lesions were scanned against an aqueous solution containing fluorine-18 (18F) as the background. Regions-of-interest were drawn with MIM Software using 40% fixed threshold (40% FT) and a gradient segmentation algorithm (MIM's PET Edge+). Recovery coefficients (RCs) (max, mean, peak, and newly defined "apex"), metabolic tumour volume (MTV), and total tumour uptake (TTU) were calculated for each sphere. SUVpeak and SUVapex had the most consistent RCs for different lesion-to-background ratios and reconstruction parameters. The gradient-based segmentation algorithm was more accurate than 40% FT for determining MTV and TTU, particularly for lesions [Formula: see text] 6 mm in diameter (R2 = 0.979-0.996 vs. R2 = 0.115-0.527, respectively). CONCLUSION: An anthropomorphic phantom was used to evaluate quantitation for PSMA PET imaging of metastatic prostate cancer lesions. BSREM with ß = 200-400 and OSEM with 2-5 iterations resulted in the most accurate and robust measurements of SUVmean, MTV, and TTU for imaging conditions in 18F-PSMA PET/CT images. SUVapex, a hybrid metric of SUVmax and SUVpeak, was proposed for robust, accurate, and segmentation-free quantitation of lesions for PSMA PET.

10.
PET Clin ; 17(1): 137-143, 2022 Jan.
Article in English | MEDLINE | ID: mdl-34809863

ABSTRACT

PET imaging with targeted novel tracers has been commonly used in the clinical management of prostate cancer. The use of artificial intelligence (AI) in PET imaging is a relatively new approach and in this review article, we will review the current trends and categorize the currently available research into the quantification of tumor burden within the organ, evaluation of metastatic disease, and translational/supplemental research which aims to improve other AI research efforts.


Subject(s)
Artificial Intelligence , Prostatic Neoplasms , Humans , Male , Positron-Emission Tomography , Prostatic Neoplasms/diagnostic imaging
11.
Med Phys ; 48(8): 4205-4217, 2021 Aug.
Article in English | MEDLINE | ID: mdl-34031896

ABSTRACT

PURPOSE: Respiratory motion during positron emission tomography (PET) scans can be a major detriment to image quality in oncological imaging. The impact of motion on lesion quantification and detectability can be assessed using phantoms with realistic anatomy representation and motion modeling. In this work, we develop an anthropomorphic phantom for PET imaging that combines anatomic fidelity and a realistic breathing mechanism with deformable lungs. METHODS: We start from a previously developed anatomically accurate but static phantom of a human torso, and add elastic lungs with a highly controllable actuation mechanism which replicates the physics of breathing. The space outside the lungs is filled with a radioactive water solution. To maintain anatomical accuracy and realistic gamma ray attenuation in the torso, all motion mechanisms and actuators are positioned outside of the phantom compartment. The actuation mechanism can produce custom respiratory waveforms with breathing rates up to 25 breaths per minute and tidal volumes up to 1200 mL. RESULTS: Several tests were performed to validate the performance of the phantom assembly, in which the phantom was filled with water and given respiratory waveforms to execute. All parts demonstrated expected performance. Force requirements were not exceeded and no leaks were detected, although continued use of the phantom is required to evaluate wear. The motion of the lungs was determined to be within a reasonable realistic range. CONCLUSIONS: The full mechanical design is described in this paper, as well as a software application with graphical user interface which was developed to plan and visualize respiratory patterns. Both are available online as open source files. The developed phantom will facilitate future work in evaluating the impact of respiratory motion on lesion quantification and detectability in clinical practice.


Subject(s)
Positron-Emission Tomography , Respiration , Humans , Lung/diagnostic imaging , Motion , Phantoms, Imaging
12.
J Cereb Blood Flow Metab ; 41(1): 116-131, 2021 01.
Article in English | MEDLINE | ID: mdl-32050828

ABSTRACT

Current methods using a single PET scan to detect voxel-level transient dopamine release-using F-test (significance) and cluster size thresholding-have limited detection sensitivity for clusters of release small in size and/or having low release levels. Specifically, simulations show that voxels with release near the peripheries of such clusters are often rejected-becoming false negatives and ultimately distorting the F-distribution of rejected voxels. We suggest a Monte Carlo method that incorporates these two observations into a cost function, allowing erroneously rejected voxels to be accepted under specified criteria. In simulations, the proposed method improves detection sensitivity by up to 50% while preserving the cluster size threshold, or up to 180% when optimizing for sensitivity. A further parametric-based voxelwise thresholding is then suggested to better estimate the release dynamics in detected clusters. We apply the Monte Carlo method to a pilot scan from a human gambling study, where additional parametrically unique clusters are detected as compared to the current best methods-results consistent with our simulations.


Subject(s)
Dopamine/metabolism , Monte Carlo Method , Positron-Emission Tomography/methods , Humans
13.
Phys Med Biol ; 65(23): 235004, 2020 12 18.
Article in English | MEDLINE | ID: mdl-33065566

ABSTRACT

Measurement of stimulus-induced dopamine release and other types of transient neurotransmitter response (TNR) from dynamic positron emission tomography (PET) images typically suffers from limited detection sensitivity and high false positive (FP) rates. Measurement of TNR of a voxel-level can be particularly problematic due to high image noise. In this work, we perform voxel-level TNR detection using artificial neural networks (ANN) and compare their performance to previously used standard statistical tests. Different ANN architectures were trained and tested using simulated and real human PET imaging data, obtained with the tracer [11C]raclopride (a D2 receptor antagonist). A distinguishing feature of our approach is the use of 'personalized' ANNs that are designed to operate on the image from a specific subject and scan. Training of personalized ANNs was performed using simulated images that have been matched with the acquired image in terms of the signal, resolution, and noise. In our tests of TNR detection performance, the F-test of the linear parametric neurotransmitter PET model fit residuals was used as the reference method. For a moderate TNR magnitude, the areas under the receiver operating characteristic curves in simulated tests were 0.64 for the F-test and 0.77-0.79 for the best ANNs. At a fixed FP rate of 0.01, the true positive rates were 0.6 for the F-test and 0.8-0.9 for the ANNs. The F-test detected on average 28% of a 8.4 mm cluster with a strong TNR, while the best ANN detected 47%. When applied to a real image, no significant abnormalities in the ANN outputs were observed. These results demonstrate that personalized ANNs may offer a greater detection sensitivity of dopamine release and other types of TNR compared to previously used method based on the F-test.


Subject(s)
Brain/metabolism , Carbon Radioisotopes/analysis , Neural Networks, Computer , Neurotransmitter Agents/metabolism , Positron-Emission Tomography/methods , Precision Medicine , Raclopride/pharmacokinetics , Brain/diagnostic imaging , Dopamine Antagonists/pharmacokinetics , Humans , Metabolic Clearance Rate , Neurotransmitter Agents/analysis , Radiopharmaceuticals/pharmacokinetics , Tissue Distribution
14.
Phys Med ; 69: 233-240, 2020 Jan.
Article in English | MEDLINE | ID: mdl-31918375

ABSTRACT

PURPOSE: It is vital to appropriately power clinical trials towards discovery of novel disease-modifying therapies for Parkinson's disease (PD). Thus, it is critical to improve prediction of outcome in PD patients. METHODS: We systematically probed a range of robust predictor algorithms, aiming to find best combinations of features for significantly improved prediction of motor outcome (MDS-UPDRS-III) in PD. We analyzed 204 PD patients with 18 features (clinical measures; dopamine-transporter (DAT) SPECT imaging measures), performing different randomized arrangements and utilizing data from 64%/6%/30% of patients in each arrangement for training/training validation/final testing. We pursued 3 approaches: i) 10 predictor algorithms (accompanied with automated machine learning hyperparameter tuning) were first applied on 32 experimentally created combinations of 18 features, ii) we utilized Feature Subset Selector Algorithms (FSSAs) for more systematic initial feature selection, and iii) considered all possible combinations between 18 features (262,143 states) to assess contributions of individual features. RESULTS: A specific set (set 18) applied to the LOLIMOT (Local Linear Model Trees) predictor machine resulted in the lowest absolute error 4.32 ± 0.19, when we firstly experimentally created 32 combinations of 18 features. Subsequently, 2 FSSAs (Genetic Algorithm (GA) and Ant Colony Optimization (ACO)) selecting 5 features, combined with LOLIMOT, reached an error of 4.15 ± 0.46. Our final analysis indicated that longitudinal motor measures (MDS-UPDRS-III years 0 and 1) were highly significant predictors of motor outcome. CONCLUSIONS: We demonstrate excellent prediction of motor outcome in PD patients by employing automated hyperparameter tuning and optimal utilization of FSSAs and predictor algorithms.


Subject(s)
Machine Learning , Parkinson Disease/diagnostic imaging , Parkinson Disease/physiopathology , Adult , Aged , Aged, 80 and over , Algorithms , Computer Simulation , Dopamine Plasma Membrane Transport Proteins/chemistry , Female , Humans , Male , Middle Aged , Pattern Recognition, Automated , Reproducibility of Results , Tomography, Emission-Computed, Single-Photon , Treatment Outcome
15.
Neuroimage Clin ; 25: 102150, 2020.
Article in English | MEDLINE | ID: mdl-31901793

ABSTRACT

Most neurodegenerative disorders are characterized by progressive loss of neurons throughout the course of disease in the form of specific spatio-temporal patterns. To capture and quantify these coherent patterns across both space and time, traditionally one would either fit a pre-defined model with spatial and temporal parameters or apply analysis in the spatial and temporal domains separately. In this work, we introduce and validate the use of dynamic mode decomposition (DMD), a data-driven multivariate approach, to extract coupled spatio-temporal patterns simultaneously. We apply the method to examine progressive dopaminergic degeneration in 41 patients with Parkinson's disease (PD) using [11C](±)dihydrotetrabenazine (DTBZ) Positron Emission Tomography (PET). DMD decomposed the progressive dopaminergic changes in the putamen into two orthogonal temporal progression curves associated with distinct spatial patterns: 1) an anterior-posterior gradient, the expression of which decreased gradually with disease progression with a higher initial expression in the less affected side; 2) a dorsal-ventral gradient in the less affected side, which was present in early disease stage only. In the caudate, we found a head-tail gradient analogous to the anterior-posterior gradient seen in the putamen; as in the putamen, the expression of this gradient decreased gradually with disease progression with higher expression in the less affected side. Our results with DTBZ PET data show the applicability and relevance of the proposed method for extracting spatio-temporal patterns of neurotransmitter changes due to neurodegeneration. The method is able to decompose known PD-induced dopaminergic denervation into orthogonal (and thus loosely independent) temporal curves, which may be able to reflect and separate either different mechanisms underlying disease progression and disease initiation, or differential involvement of striatal sub-regions at different disease stages, in a completely data driven way. It is expected that this method can be easily extended to other PET tracers and neurodegenerative disorders and may help to elucidate disease mechanisms in more details compared to traditional approaches.


Subject(s)
Image Interpretation, Computer-Assisted/methods , Neuroimaging/methods , Parkinson Disease/diagnostic imaging , Parkinson Disease/pathology , Positron-Emission Tomography/methods , Putamen/diagnostic imaging , Putamen/pathology , Aged , Dopamine/metabolism , Female , Humans , Male , Middle Aged , Parkinson Disease/metabolism , Putamen/metabolism , Tetrabenazine/analogs & derivatives
16.
IEEE Trans Med Imaging ; 39(2): 366-376, 2020 02.
Article in English | MEDLINE | ID: mdl-31283475

ABSTRACT

Application of kinetic modeling (KM) on a voxel level in dynamic PET images frequently suffers from high levels of noise, drastically reducing the precision of parametric image analysis. In this paper, we investigate the use of machine learning and artificial neural networks to denoise dynamic PET images. We train a deep denoising autoencoder (DAE) using noisy and noise-free spatiotemporal image patches, extracted from the simulated images of [11C]raclopride, a dopamine D2 receptor agonist. The DAE-processed dynamic and corresponding parametric images (simulated and acquired) are compared with those obtained with conventional denoising techniques, including temporal and spatial Gaussian smoothing, iterative spatiotemporal smoothing/deconvolution, and the highly constrained backprojection processing (HYPR). The simulated (acquired) parametric image non-uniformity was 7.75% (19.49%) with temporal and 5.90% (14.50%) with spatial smoothing, 5.82% (16.21%) with smoothing/deconvolution, 5.49% (13.38%) with HYPR, and 3.52% (11.41%) with DAE. The DAE also produced the best results in terms of the coefficient of variation of voxel values and structural similarity index. Denoising-induced bias in the regional mean binding potential was 7.8% with temporal and 26.31% with spatial smoothing, 28.61% with smoothing/deconvolution, 27.63% with HYPR, and 14.8% with DAE. When the test data did not match the training data, erroneous outcomes were obtained. Our results demonstrate that a deep DAE can provide a substantial reduction in the voxel-level noise compared with the conventional spatiotemporal denoising methods while introducing a similar or lower amount of bias. The better DAE performance comes at the cost of lower generality and requiring appropriate training data.


Subject(s)
Image Processing, Computer-Assisted/methods , Neural Networks, Computer , Positron-Emission Tomography/methods , Brain/diagnostic imaging , Brain/metabolism , Humans , Machine Learning , Phantoms, Imaging , Raclopride/pharmacokinetics
17.
Comput Biol Med ; 111: 103347, 2019 08.
Article in English | MEDLINE | ID: mdl-31284154

ABSTRACT

BACKGROUND: Given the increasing recognition of the significance of non-motor symptoms in Parkinson's disease, we investigate the optimal use of machine learning methods for the prediction of the Montreal Cognitive Assessment (MoCA) score at year 4 from longitudinal data obtained at years 0 and 1. METHODS: We selected n = 184 PD subjects from the Parkinson's Progressive Marker Initiative (PPMI) database (93 features). A range of robust predictor algorithms (accompanied with automated machine learning hyperparameter tuning) and feature subset selector algorithms (FSSAs) were selected. We utilized 65%, 5% and 30% of patients in each arrangement for training, training validation and final testing respectively (10 randomized arrangements). For further testing, we enrolled 308 additional patients. RESULTS: First, we employed 10 predictor algorithms, provided with all 93 features; an error of 1.83 ±â€¯0.13 was obtained by LASSOLAR (Least Absolute Shrinkage and Selection Operator - Least Angle Regression). Subsequently, we used feature subset selection followed by predictor algorithms. GA (Genetic Algorithm) selected 18 features; subsequently LOLIMOT (Local Linear Model Trees) reached an error of 1.70 ±â€¯0.10. DE (Differential evolution) also selected 18 features and coupled with Thiel-Sen regression arrived at a similar performance. NSGAII (Non-dominated sorting genetic algorithm) yielded the best performance: it selected six vital features, which combined with LOLIMOT reached an error of 1.68 ±â€¯0.12. Finally, using this last approach on independent test data, we reached an error of 1.65. CONCLUSION: By employing appropriate optimization tools (including automated hyperparameter tuning), it is possible to improve prediction of cognitive outcome. Overall, we conclude that optimal utilization of FSSAs and predictor algorithms can produce very good prediction of cognitive outcome in PD patients.


Subject(s)
Machine Learning , Mental Status and Dementia Tests/statistics & numerical data , Parkinson Disease , Adult , Aged , Aged, 80 and over , Algorithms , Disease Progression , Female , Humans , Longitudinal Studies , Male , Middle Aged , Models, Statistical , Parkinson Disease/diagnosis , Parkinson Disease/epidemiology , Parkinson Disease/pathology
18.
Mol Imaging Biol ; 21(6): 1165-1173, 2019 12.
Article in English | MEDLINE | ID: mdl-30847821

ABSTRACT

PURPOSE: Quantitative analysis of dopamine transporter (DAT) single-photon emission computed tomography (SPECT) images can enhance diagnostic confidence and improve their potential as a biomarker to monitor the progression of Parkinson's disease (PD). In the present work, we aim to predict motor outcome from baseline DAT SPECT imaging radiomic features and clinical measures using machine learning techniques. PROCEDURES: We designed and trained artificial neural networks (ANNs) to analyze the data from 69 patients within the Parkinson's Progressive Marker Initiative (PPMI) database. The task was to predict the unified PD rating scale (UPDRS) part III motor score in year 4 from 92 imaging features extracted on 12 different regions as well as 6 non-imaging measures at baseline (year 0). We first performed univariate screening (including the adjustment for false discovery) to select 4 regions each having 10 features with significant performance in classifying year 4 motor outcome into two classes of patients (divided by the UPDRS III threshold of 30). The leave-one-out strategy was then applied to train and test the ANNs for individual and combinations of features. The prediction statistics were calculated from 100 rounds of experiments, and the accuracy in appropriate prediction (classification of year 4 outcome) was quantified. RESULTS: Out of the baseline non-imaging features, only the UPDRS III (at year 0) was predictive, while multiple imaging features depicted significance. The different selected features reached a predictive accuracy of 70 % if used individually. Combining the top imaging features from the selected regions significantly improved the prediction accuracy to 75 % (p < 0.01). The combination of imaging features with the year 0 UPDRS III score also improved the prediction accuracy to 75 %. CONCLUSION: This study demonstrated the added predictive value of radiomic features extracted from DAT SPECT images in serving as a biomarker for PD progression tracking.


Subject(s)
Neural Networks, Computer , Parkinson Disease/diagnostic imaging , Tomography, Emission-Computed, Single-Photon , Female , Humans , Imaging, Three-Dimensional , Male , Middle Aged , Treatment Outcome
19.
PLoS One ; 13(11): e0206607, 2018.
Article in English | MEDLINE | ID: mdl-30395576

ABSTRACT

Spatial patterns of radiotracer binding in positron emission tomography (PET) images may convey information related to the disease topology. However, this information is not captured by the standard PET image analysis that quantifies the mean radiotracer uptake within a region of interest (ROI). On the other hand, spatial analyses that use more advanced radiomic features may be difficult to interpret. Here we propose an alternative data-driven, voxel-based approach to spatial pattern analysis in brain PET, which can be easily interpreted. We apply principal component analysis (PCA) to identify voxel covariance patterns, and optimally combine several patterns using the least absolute shrinkage and selection operator (LASSO). The resulting models predict clinical disease metrics from raw voxel values, allowing for inclusion of clinical covariates. The analysis is performed on high-resolution PET images from healthy controls and subjects affected by Parkinson's disease (PD), acquired with a pre-synaptic and a post-synaptic dopaminergic PET tracer. We demonstrate that PCA identifies robust and tracer-specific binding patterns in sub-cortical brain structures; the patterns evolve as a function of disease progression. Principal component LASSO (PC-LASSO) models of clinical disease metrics achieve higher predictive accuracy compared to the mean tracer binding ratio (BR) alone: the cross-validated test mean squared error of adjusted disease duration (motor impairment score) was 16.3 ± 0.17 years2 (9.7 ± 0.15) with mean BR, versus 14.4 ± 0.18 years2 (8.9 ± 0.16) with PC-LASSO. We interpret the best-performing PC-LASSO models in the spatial sense and discuss them with reference to the PD pathology and somatotopic organization of the striatum. PC-LASSO is thus shown to be a useful method to analyze clinically-relevant tracer binding patterns, and to construct interpretable, imaging-based predictive models of clinical metrics.


Subject(s)
Brain/diagnostic imaging , Nerve Degeneration/diagnostic imaging , Neuroimaging/statistics & numerical data , Positron-Emission Tomography/statistics & numerical data , Adult , Aged , Brain/pathology , Case-Control Studies , Female , Humans , Image Interpretation, Computer-Assisted/statistics & numerical data , Least-Squares Analysis , Magnetic Resonance Imaging/statistics & numerical data , Male , Middle Aged , Nerve Degeneration/pathology , Parkinson Disease/diagnostic imaging , Parkinson Disease/pathology , Pattern Recognition, Automated/statistics & numerical data , Principal Component Analysis , Spatio-Temporal Analysis
20.
IEEE Trans Med Imaging ; 36(6): 1263-1275, 2017 06.
Article in English | MEDLINE | ID: mdl-28287962

ABSTRACT

Quantitative positron emission tomography imaging often requires correcting the image data for deformable motion. With cyclic motion, this is traditionally achieved by separating the coincidence data into a relatively small number of gates, and incorporating the inter-gate image transformation matrices into the reconstruction algorithm. In the presence of non-cyclic deformable motion, this approach may be impractical due to a large number of required gates. In this paper, we propose an alternative approach to iterative image reconstruction with correction for deformable motion, wherein unorganized point clouds are used to model the imaged objects in the image space, and motion is corrected for explicitly by introducing a time-dependence into the point coordinates. The image function is represented using constant basis functions with finite support determined by the boundaries of the Voronoi cells in the point cloud. We validate the quantitative accuracy and stability of the proposed approach by reconstructing noise-free and noisy projection data from digital and physical phantoms. The point-cloud-based maximum likelihood expectation maximization (MLEM) and one-pass list-mode ordered-subset expectation maximization (OSEM) algorithms are validated. The results demonstrate that images reconstructed using the proposed method are quantitatively stable, with noise and convergence properties comparable to image reconstruction based on the use of rectangular and radially-symmetric basis functions.


Subject(s)
Image Processing, Computer-Assisted , Algorithms , Motion , Phantoms, Imaging , Positron-Emission Tomography
SELECTION OF CITATIONS
SEARCH DETAIL
...