Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Anal Chim Acta ; 1066: 93-101, 2019 Aug 20.
Article in English | MEDLINE | ID: mdl-31027538

ABSTRACT

Non-targeted small molecule screening methods are used to analyze samples for potential compounds of interest without focusing on specific molecular species. There is great interest in these methods for metabolomic, environmental, forensic, and food safety applications, among others, to determine compounds that are responsible for a particular disease state or the presence of a harmful compound. In order for non-targeted analyses to become standardized and routine, best practices for sample preparation, data collection, and data analysis must be determined. This work focuses on optimizing specific aspects of a non-targeted workflow that utilizes high-resolution mass spectrometry using an Orbitrap instrument coupled to liquid chromatography. Sample preparation, liquid chromatography gradient length, and mass spectrometry resolving power and ionization modes were investigated to determine optimal conditions for detecting and extracting compounds from the data that cover broad molecular and polarity ranges. Infant rice cereal, orange juice, and yogurt with spiked standards were analyzed; food is inherently challenging to analyze due in part to sample complexity and diversity. Of the conditions tested, optimal conditions included a generic sample extraction using acetonitrile, water, and formic acid, a 25 min chromatographic gradient, collecting data in both positive and negative ion modes, and using 70 k resolving power. There are of course tradeoffs associated with each of these options that will be described in detail so that the appropriate conditions can be chosen for the desired application.

2.
J Biomed Opt ; 21(11): 117004, 2016 11 01.
Article in English | MEDLINE | ID: mdl-27893090

ABSTRACT

During emergency medical situations, where the patient has an obstructed airway or necessitates respiratory support, endotracheal intubation (ETI) is the medical technique of placing a tube into the trachea in order to facilitate adequate ventilation of the lungs. Complications during ETI, such as repeated attempts, failed intubation, or accidental intubation of the esophagus, can lead to severe consequences or ultimately death. Consequently, a need exists for a feedback mechanism to aid providers in performing successful ETI. Our study examined the spectral reflectance properties of the tracheal and esophageal tissue to determine whether a unique spectral profile exists for either tissue for the purpose of detection. The study began by using a hyperspectral camera to image excised pig tissue samples exposed to white and UV light in order to capture the spectral reflectance properties with high fidelity. After identifying a unique spectral characteristic of the trachea that significantly differed from esophageal tissue, a follow-up investigation used a fiber optic probe to confirm the detectability and consistency of the different reflectance characteristics in a pig model. Our results characterize the unique and consistent spectral reflectance characteristic of tracheal tissue, thereby providing foundational support for exploiting spectral properties to detect the trachea during medical procedures.


Subject(s)
Esophagus/diagnostic imaging , Fiber Optic Technology/methods , Image Processing, Computer-Assisted/methods , Optical Imaging/methods , Trachea/diagnostic imaging , Animals , Esophagus/physiology , Intubation, Intratracheal , Principal Component Analysis , Swine , Trachea/physiology
SELECTION OF CITATIONS
SEARCH DETAIL
...