1.
World J Pediatr Congenit Heart Surg ; 15(3): 371-379, 2024 05.
Article in English | MEDLINE | ID: mdl-38327093

ABSTRACT

BACKGROUND: Restoring adequate coaptation height is a key principle of mitral valve (MV) repair. This study aimed to evaluate the utility of fiberscope (FS) technology to assess MV coaptation height for intraoperative use. METHODS: Ex-vivo testing was performed on five adult porcine hearts. The left atrium (LA) was resected, and the left ventricle (LV) was pressurized retrograde to 27 ± 1mm Hg. An endoscope was inserted into the LV apex, centered under the MV orifice. An FS system (Milliscope II camera, LED light source, and 0.7 mm diameter × 15 cm long) 90° semirigid scope with 1.2 mm focal length) was mounted above the MV annulus in a custom alignment and measuring fixture. Three blinded measurements were taken at two locations on each MV, A2 and P2 segment, from the top of coaptation to the leaflet edge identified by the FS. Accurate positioning was verified using the LV endoscope. A control (metal rod of similar thickness) was used for comparison, with coaptation height recorded when the control was seen via the endoscope. RESULTS: Coaptation heights were similar for the control and FS methods across all hearts at A2 (11.6 ± 2.6 mm control vs 11.8 ± 2.2 mm FS) and P2 (13.3 ± 2.6 mm control vs 13.4 ± 2.9 mm FS) segments, with similar measurement variability (control SD 0.1-1.0 mm; FS SD 0.1-0.9 mm). One outlier was excluded from analysis (n = 19/20). The maximum absolute difference and percent error between measurement methods were less than 1.1 mm (median [IQR], 0.6 [0.3-0.9] mm) and less than 14% (4.1 [2.2-7.6]%). CONCLUSIONS: Utilization of a miniaturized FS enabled precise and accurate quantification of MV coaptation. This technique is promising for evaluating post-repair valve competence and coaptation height.


Subject(s)
Mitral Valve , Animals , Swine , Mitral Valve/surgery , Equipment Design , Disease Models, Animal , Endoscopy/methods , Cardiac Surgical Procedures/methods , Cardiac Surgical Procedures/instrumentation , Mitral Valve Insufficiency/surgery , Fiber Optic Technology
2.
Cardiovasc Eng Technol ; 14(6): 827-839, 2023 12.
Article in English | MEDLINE | ID: mdl-37973699

ABSTRACT

PURPOSE: Pulmonary valve (PV) monocusp reconstruction in transannular patch (TAP) right ventricular outflow tract (RVOT) repair for Tetralogy of Fallot has variable clinical outcomes across different surgical approaches. The study purpose was to systematically evaluate how monocusp leaflet design parameters affect valve function in-vitro. METHODS: A 3D-printed, disease-specific RVOT model was tested under three infant physiological conditions. Monocusps were sewn into models with the native main pulmonary artery (MPA) forming backwalls that constituted 40% and 50% of the reconstructed circumference for z-score zero PV annulus and MPA diameters (native PV z-score - 3.52 and - 2.99 for BSA 0.32m2). Various leaflet free edge lengths (FEL) (relative to backwall), positions (relative to PV STJ), and scallop depths were investigated across both models. Pressure gradient, regurgitation, and coaptation were analyzed with descriptive statistics and regression models. RESULTS: Increasing FEL beyond 100% of the MPA backwall decreased gradient but mildly increased regurgitation to a peak of 25%. Positioning the free edge 2 mm past the STJ mildly increased gradient for each FEL without significantly changing regurgitation compared to STJ placement. Scalloping leaflets trivially affected performance. Pre-folding leaflets improved mobility and slightly reduced gradient. CONCLUSIONS: Balancing gradient, regurgitation, and oversizing for growth, a set of leaflet designs have been selected for pre-clinical evaluation. Designs with leaflet widths 140-160% in the 40% backwall model (110-120% in the 50% backwall), positioned at or 2 mm past the STJ, demonstrated the best results. The next stage of ex-vivo testing will additionally consider native RVOT distensibility, native leaflet interactions, and TAP characteristics.


Subject(s)
Pulmonary Valve Insufficiency , Pulmonary Valve , Tetralogy of Fallot , Infant , Humans , Tetralogy of Fallot/diagnostic imaging , Tetralogy of Fallot/surgery , Heart Ventricles , Polytetrafluoroethylene , Treatment Outcome , Retrospective Studies
3.
Eur J Cardiothorac Surg ; 64(5)2023 11 01.
Article in English | MEDLINE | ID: mdl-37897688

ABSTRACT

OBJECTIVES: Thick-patch pulmonary homograft, autologous pericardium and CardioCel Neo are common patch materials for aortic arch reconstruction. Insufficient data exist on sutured patch strength and limits of use. We evaluated failure strength of these materials to develop a failure prediction model for clinical guidance. METHODS: Patch failure strength was evaluated via sutured uniaxial and burst pressure testing. In sutured uniaxial testing, patches were sutured to aortic or Dacron tabs and pulled to failure. In burst pressure testing, patches were sewn into porcine aortas or Dacron grafts and pressurized to failure. Failure membrane tension was calculated. A prediction model of membrane tension versus vessel diameter was generated to guide clinical patch selection. RESULTS: Combining sutured uniaxial and burst pressure test data, pulmonary homograft failure strength {0.61 [interquartile range (IQR): 0.44, 0.78] N/mm, n = 21} was less than half that of autologous pericardium [2.22 (IQR: 1.65, 2.78) N/mm, n = 15] and CardioCel Neo [1.31 (IQR: 1.20, 1.42) N/mm, n = 20]. Pulmonary homograft burst pressure [245 (IQR: 202, 343) mmHg, n = 7] was significantly lower than autologous pericardium [863 (IQR: 802, 919) mmHg, n = 6] and CardioCel Neo [766 (IQR: 721, 833) mmHg, n = 6]. Our model predicts failure limits for each patch material and outlines safety margins for combinations of aortic diameter and pressure. CONCLUSIONS: Sutured failure strength of thick-patch pulmonary homograft was significantly lower than autologous pericardium and CardioCel Neo. Patient selection (predicted postoperative arch diameter and haemodynamics) and blood pressure management must be considered when choosing patch material for arch reconstruction. In older children and adolescents, autologous or bovine pericardium may be more suitable materials for aortic patch augmentation to minimize the risk of postoperative patch failure.


Subject(s)
Aorta, Thoracic , Polyethylene Terephthalates , Child , Humans , Animals , Cattle , Swine , Adolescent , Aorta, Thoracic/surgery , Aorta , Blood Pressure , Hemodynamics , Pericardium/transplantation , Retrospective Studies
4.
Sci Adv ; 9(43): eadi5559, 2023 10 27.
Article in English | MEDLINE | ID: mdl-37878705

ABSTRACT

In minimally invasive endovascular procedures, surgeons rely on catheters with low dexterity and high aspect ratios to reach an anatomical target. However, the environment inside the beating heart presents a combination of challenges unique to few anatomic locations, making it difficult for interventional tools to maneuver dexterously and apply substantial forces on an intracardiac target. We demonstrate a millimeter-scale soft robotic platform that can deploy and self-stabilize at the entrance to the heart, and guide existing interventional tools toward a target site. In two exemplar intracardiac procedures within the right atrium, the robotic platform provides enough dexterity to reach multiple anatomical targets, enough stability to maintain constant contact on motile targets, and enough mechanical leverage to generate newton-level forces. Because the device addresses ongoing challenges in minimally invasive intracardiac intervention, it may enable the further development of catheter-based interventions.


Subject(s)
Robotics , Catheters , Heart Atria , Equipment Design
5.
Article in English | MEDLINE | ID: mdl-37555820

ABSTRACT

OBJECTIVES: Reconstruction of cardiovascular anatomy with patch material is integral to the repair of congenital heart disease. We present validation of a laser projection platform for the preparation of surgical patches as a proof-of-concept for intraoperative use in patient-specific planning of paediatric cardiac surgery reconstructions. METHODS: The MicroLASERGUIDE, a compact laser projection system that displays computer-aided designs onto 2D/3D surfaces, serves as an alternative to physical templates. A non-inferiority comparison of dimensional measurements was conducted between laser projection ('laser') and OZAKI AVNeo Template ('template') methods in creation of 51 (each group) size 13 valve leaflets from unfixed bovine pericardium. A digital version of the OZAKI AVNeo Template dimensions served as control. Feasibility testing was performed with other common patch materials (fixed bovine pericardium, PTFE and porcine main pulmonary artery as a substitute for pulmonary homograft) and sizes (13, 23) (n = 3 each group). RESULTS: Compared to control (height 21.5, length 21.0 mm), template height and length were smaller (height and length differences of -0.3 [-0.5 to 0.0] and -0.4 [-0.8 to -0.1] mm, P < 0.01 each); whereas, both laser height and length were relatively similar (height and length differences of height 0.0 [-0.2 to 0.2], P = 0.804, and 0.2 [-0.1 to 0.4] mm, P = 0.029). Template percent error for height and length was -1.5 (-2.3 to 0.0)% and -1.9 (-3.7 to -0.6)% vs 0.2 (-1.0 to 1.1)% and 1.0 (-0.5 to 1.8)% for the laser. Similar results were found with other materials and sizes. Overall, laser sample dimensions differed by a maximum of 5% (∼1 mm) from the control. CONCLUSIONS: The laser projection platform has demonstrated promise as an alternative methodology for the preparation of surgical patches for use in cardiac surgery. This technology has potential to revolutionize preoperative surgical planning for numerous congenital anomalies that require patient-specific patch-augmented repair.

6.
Cardiovasc Eng Technol ; 14(2): 217-229, 2023 04.
Article in English | MEDLINE | ID: mdl-36456745

ABSTRACT

PURPOSE: Tetralogy of Fallot and other conditions affecting the right ventricular outflow tract (RVOT) are common in pediatric patients, but there is a lack of quantitative comparison among techniques for repairing or replacing the pulmonary valve. The aim of this study was to develop a robust in vitro system for quantifying flow conditions after various RVOT interventions. METHODS: An infant-sized mock circulatory loop that includes a 3D-printed RVOT anatomical model was developed to evaluate flow conditions after different simulated surgical repairs. Physiologically correct flow and pressure were achieved with custom compliant tubing and a tunable flow restrictor. Pressure gradient, flow regurgitation, and coaptation height were measured for two monocusp leaflet designs after tuning the system with a 12 mm Hancock valved conduit. RESULTS: Measurements were repeatable across multiple samples of two different monocusp designs, with the wider leaflet in the 50% backwall model consistently exhibiting lower pressure gradient but higher regurgitation compared to the leaflet in the 40% backwall model. Coaptation height was measured via direct visualization with endoscopic cameras, revealing a shorter area of contact for the wider leaflet (3.3-4.0 mm) compared to the narrower one (4.3 mm). CONCLUSION: The 3D-printed RVOT anatomical model and in vitro pulmonary circulatory loop developed in this work provide a platform for planning and evaluating surgical interventions in the pediatric population. Measurements of regurgitation, pressure gradient, and coaptation provide a quantitative basis for comparison among different valve designs and positions.


Subject(s)
Heart Valve Prosthesis , Pulmonary Valve , Tetralogy of Fallot , Ventricular Outflow Obstruction , Infant , Child , Humans , Tetralogy of Fallot/diagnostic imaging , Tetralogy of Fallot/surgery , Ventricular Outflow Obstruction/surgery , Pulmonary Valve/diagnostic imaging , Pulmonary Valve/surgery , Heart Ventricles , Pulmonary Circulation , Treatment Outcome