Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
J Feline Med Surg ; 26(3): 1098612X241231471, 2024 03.
Article in English | MEDLINE | ID: mdl-38546192

ABSTRACT

OBJECTIVES: Systemic arterial hypertension is a common occurrence and can have serious adverse consequences in cats. Therefore, measuring blood pressure is very important. There are many indirect blood pressure measurement devices available. This study compared Doppler, oscillometric (petMAP Graphic II, SunTech Vet20, the Cardell Insight-X0000) and high-definition oscillometry devices for the non-invasive measurement of blood pressure in conscious cats. METHODS: In this prospective study, blood pressure was measured in 32 cats using the different devices according to the recommendations of the American College of Veterinary Internal Medicine Consensus Statement. Blood pressures (systolic blood pressure [SBP], diastolic blood pressure [DBP], mean arterial pressure [MAP]), time to complete measurements, number of attempts needed, coefficient of variation (CV) between the blood pressure measurements of the different devices, ease of completing measurements and apparent stress level of the cat were assessed. RESULTS: There was a significant difference between devices in the time taken to obtain blood pressure readings and the number of attempts necessary to obtain six reliable measurements. The CV of the Doppler device was significantly smaller than that of the rest of the devices, but there were no other differences between the devices. The mean SBP, DBP and MAP measured by the petMAP device were significantly higher than the measurements from the other devices. The perceived ease of measurement was not significantly different between the various machines. The perceived level of stress of measurement with the Doppler device was significantly higher compared with the other devices but did not lead to an increased SBP. CONCLUSIONS AND RELEVANCE: Using a Doppler device to measure blood pressure in conscious cats is fast, relatively easy and gives reliable results. A disadvantage is that the Doppler device can only measure SBP, while oscillometric devices also provide DBP and MAP. However, in veterinary medicine, systolic hypertension is considered the most relevant.


Subject(s)
Blood Pressure Determination , Ultrasonics , Cats , Animals , Blood Pressure/physiology , Oscillometry/veterinary , Oscillometry/methods , Prospective Studies , Blood Pressure Determination/veterinary
2.
J Feline Med Surg ; 25(6): 1098612X231172629, 2023 06.
Article in English | MEDLINE | ID: mdl-37278217

ABSTRACT

OBJECTIVES: Systemic arterial hypertension is increasingly recognised and can have serious adverse consequences in cats. Unfortunately, the act of measuring blood pressure itself may cause an increase in blood pressure, known as situational hypertension. It is currently unknown how often this phenomenon occurs. The aim of this study was to evaluate the prevalence of persistent hypertension and situational hypertension in an elderly population of cats in a first-opinion clinic and to assess which factors were associated with systolic hypertension. METHODS: In this prospective study, systolic blood pressure was measured in 185 cats aged ⩾10 years using the Doppler sphygmomanometry method according to the recommendations of the American College of Veterinary Internal Medicine consensus statement. Age, sex, body weight, body condition score, position during blood pressure measurement and apparent stress level were assessed. If a systolic blood pressure >160 mmHg was found, measurements were repeated to evaluate if persistent hypertension or situational hypertension was present. The first set of blood pressure measurements were used for all the statistical analyses. RESULTS: The median systolic blood pressure for this population was 140 mmHg. The prevalence of persistent hypertension was at least 14.6% and situational hypertension at least 5.4%. Factors significantly associated with hypertension were age, higher apparent stress levels and a sitting position during measurement. Sex, body weight or body condition score did not significantly influence systolic blood pressure. CONCLUSIONS AND RELEVANCE: Both persistent hypertension and situational hypertension are common in elderly cats. There are no reliable parameters to distinguish between the two, underlining the importance of a standard protocol and repeating measurements during a follow-up visit when hypertension is found. Age, demeanour and body position during blood pressure measurement influenced blood pressure in this population of elderly cats.


Subject(s)
Cat Diseases , Hypertension , Animals , Cats , Blood Pressure/physiology , Cat Diseases/epidemiology , Hypertension/epidemiology , Hypertension/veterinary , Netherlands , Prevalence , Prospective Studies
3.
J Feline Med Surg ; 24(8): e223-e231, 2022 08.
Article in English | MEDLINE | ID: mdl-35762266

ABSTRACT

OBJECTIVES: Home blood glucose monitoring using a portable blood glucose meter is important in the management of feline diabetes mellitus, but taking blood samples may be stressful for owners and cats. A flash glucose monitoring system measuring interstitial glucose, such as the FreeStyle Libre, overcomes some of these drawbacks. The aim of this study was to evaluate the practical use and analytical and clinical accuracy of the FreeStyle Libre in 41 client-owned diabetic cats. METHODS: In this prospective study, interstitial glucose concentrations were measured with the FreeStyle Libre and compared with blood glucose concentrations measured with a portable blood glucose meter (AlphaTRAK) on days 1, 7 or 8 and 14 after application of the device. Cat behaviour during application, location, skin reaction at the attachment site and owner satisfaction were assessed. Accuracy was determined by fulfilment of ISO 15197:2013 criteria, including Bland-Altman plotting and error grid analysis. RESULTS: Placing the device was easy, with 70% of cats showing no reaction. Most sensors were placed on the thoracic wall. Skin reactions at the attachment site were not present or mild in almost all cats. Owners were very satisfied with the use of the FreeStyle Libre. Median functional life of the sensor was 10 days (range 1-14). Good correlation was found between interstitial and blood glucose measurements (rho[r] = 0.88, P <0.0001). Fifty-three percent of interstitial glucose concentrations were within a maximum deviation of 15% from blood glucose concentrations and 92.7% were within the safe risk zones 0 and 1 of the surveillance error grid. CONCLUSIONS AND RELEVANCE: The flash glucose monitoring system was easy to use and owners of diabetic cats were satisfied with its use. Although the device did not completely fulfil ISO requirements, it is sufficiently accurate for glucose monitoring in diabetic cats.


Subject(s)
Cat Diseases , Diabetes Mellitus , Animals , Blood Glucose/analysis , Blood Glucose Self-Monitoring/veterinary , Cat Diseases/diagnosis , Cats , Diabetes Mellitus/veterinary , Glucose , Prospective Studies
4.
Vet Q ; 38(1): 72-78, 2018 Dec.
Article in English | MEDLINE | ID: mdl-30362899

ABSTRACT

BACKGROUND: In dogs, spontaneous Cushing's syndrome is most often pituitary-dependent and caused by hypersecretion of adrenocorticotropic hormone (ACTH), resulting in increased adrenocortical glucocorticoid secretion similar to horses. In horses with Cushing's syndrome (or pituitary pars intermedia dysfunction [PPID]) a thyrotropin-releasing hormone (TRH) stimulation test can be used for diagnosis, as TRH administration results in increased circulating ACTH and cortisol concentrations in affected horses. OBJECTIVE: The aim of this study was to investigate the effect of TRH administration on the circulating ACTH and cortisol concentrations in dogs with pituitary-dependent hypercortisolism (PDH). METHODS: Ten clinically normal control dogs and 10 dogs with PDH, all client owned, underwent a TRH stimulation test with measurement of plasma concentrations of ACTH and cortisol, before and after intravenous administration of 10 µg TRH/kg bodyweight. RESULTS: Plasma ACTH concentration did not rise significantly after TRH stimulation, neither in PDH dogs nor in clinically normal dogs. In contrast, the plasma cortisol concentration did increase significantly after TRH stimulation in both groups (p = .003 in PDH and p < .001 in control). Immunohistochemistry of normal adrenal glands demonstrated the presence of TRH receptors in the whole adrenal cortex. CONCLUSIONS: The results of this study demonstrate that the TRH stimulation test should be rejected as a tool to diagnose PDH in dogs. The observed TRH-induced increase in plasma cortisol concentration without a significant rise in plasma ACTH concentration may be explained by a direct effect of TRH on adrenocortical cells mediated by adrenocortical TRH receptors.


Subject(s)
Adrenocorticotropic Hormone/analysis , Dog Diseases/diagnosis , Hydrocortisone/analysis , Pituitary ACTH Hypersecretion/veterinary , Thyrotropin-Releasing Hormone/administration & dosage , Adrenocorticotropic Hormone/urine , Analysis of Variance , Animals , Case-Control Studies , Cushing Syndrome , Dog Diseases/blood , Dog Diseases/urine , Dogs , Female , Hydrocortisone/blood , Immunohistochemistry/veterinary , Male , Pituitary ACTH Hypersecretion/diagnosis
SELECTION OF CITATIONS
SEARCH DETAIL
...