Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 16 de 16
Filter
Add more filters











Publication year range
1.
Am J Speech Lang Pathol ; 33(4): 1662-1697, 2024 Jul 03.
Article in English | MEDLINE | ID: mdl-38563721

ABSTRACT

PURPOSE: The purpose of this study was to survey speech-language pathologists (SLPs) who assess and treat people with Parkinson's disease (PD) to gather insights into their decision making regarding their use or potential use of speech amplification technology for the management of hypophonia. METHOD: A total of 111 SLPs who were currently practicing in the United States or Canada and had experience working with clients with PD for at least 2 years completed an anonymous Qualtrics survey. Questions were designed to probe the following areas: (a) degree of familiarity with amplification devices as a form of treatment for PD, (b) attitudes and perceptions of the implementation of these devices for PD, and (c) factors that influence the clinical decision to prescribe such devices. RESULTS: Most participants (75; 71%) reported they had considered prescribing a device to at least one client with PD. When asked at which stages of speech or voice impairment they would consider the use of an amplification device for clients with PD, the most common response was for clients with moderate or severe hypophonia who were not stimulable for louder speech. However, 36 (32%) respondents indicated they would also consider an amplification device for clients who were stimulable for louder speech with severe hypophonia. When asked to rank the most important factors they would weigh when considering the prescription of an amplification device, they ranked the client's preference and comfort level as the most important consideration. CONCLUSION: This study provides valuable clinical insights regarding how SLPs can approach utilizing speech amplification devices in the therapy environment.


Subject(s)
Parkinson Disease , Speech-Language Pathology , Humans , Speech-Language Pathology/methods , Parkinson Disease/therapy , Attitude of Health Personnel , Male , Female , Canada , United States , Health Care Surveys , Health Knowledge, Attitudes, Practice , Middle Aged , Adult , Surveys and Questionnaires , Speech Therapy/methods , Clinical Decision-Making
2.
Am J Speech Lang Pathol ; 33(4): 1639-1661, 2024 Jul 03.
Article in English | MEDLINE | ID: mdl-38512013

ABSTRACT

PURPOSE: The purpose of this qualitative interview study was to identify themes regarding considerations in the usage of speech amplification device usage for people with Parkinson's disease (PD) and hypophonia from the perspective of speech-language pathologists (SLPs). METHOD: Eligible participants included SLPs currently practicing in the United States or Canada with experience working with clients with PD for at least 2 years. Ten SLPs participated in 60-min interviews conducted via Zoom. A semistructured interview guide was created prior to the interviews. The interviews were transcribed following their completion, and an iterative coding process was used to identify themes using thematic analysis. RESULTS: Three main themes were identified from the interviews. The first theme encapsulated how clinicians described amplification devices as a potential treatment tool, which highlighted the nuances that may impact selecting an amplification device as a treatment option such as increased hypophonia or dysarthria severity and cognitive decline. The second theme highlighted how device selection depends on the individual needs of the user. Individual client characteristics (such as disease symptoms and individual needs and preferences) may impact the choice of amplification device. The last theme outlined the importance of involving family members in all stages of device use and involving other health care team members on a case-by-case basis. CONCLUSIONS: The insights provided by the SLP participants help to understand the clinical decisions that are made when determining device candidacy, selecting a device, and evaluating device success. These insights can be used to improve research studies of augmentative management of hypophonia and guide more personalized management decisions.


Subject(s)
Parkinson Disease , Qualitative Research , Speech-Language Pathology , Humans , Speech-Language Pathology/methods , Female , Male , Parkinson Disease/complications , Parkinson Disease/therapy , Interviews as Topic , Middle Aged , Attitude of Health Personnel , Adult , Dysarthria/therapy , Dysarthria/psychology , Dysarthria/diagnosis
3.
Front Hum Neurosci ; 18: 1331816, 2024.
Article in English | MEDLINE | ID: mdl-38450224

ABSTRACT

Speech rate reduction is a global speech therapy approach for speech deficits in Parkinson's disease (PD) that has the potential to result in changes across multiple speech subsystems. While the overall goal of rate reduction is usually improvements in speech intelligibility, not all people with PD benefit from this approach. Speech rate is often targeted as a means of improving articulatory precision, though less is known about rate-induced changes in other speech subsystems that could help or hinder communication. The purpose of this study was to quantify phonatory changes associated with speech rate modification across a broad range of speech rates from very slow to very fast in talkers with and without PD. Four speaker groups participated: younger and older healthy controls, and people with PD with and without deep brain stimulation of the subthalamic nucleus (STN-DBS). Talkers read aloud standardized sentences at 7 speech rates elicited using magnitude production: habitual, three slower rates, and three faster rates. Acoustic measures of speech intensity, cepstral peak prominence, and fundamental frequency were measured as a function of speech rate and group. Overall, slower rates of speech were associated with differential effects on phonation across the four groups. While all talkers spoke at a lower pitch in slow speech, younger talkers showed increases in speech intensity and cepstral peak prominence, while talkers with PD and STN-DBS showed the reverse pattern. Talkers with PD without STN-DBS and older healthy controls behaved in between these two extremes. At faster rates, all groups uniformly demonstrated increases in cepstral peak prominence. While speech rate reductions are intended to promote positive changes in articulation to compensate for speech deficits in dysarthria, the present results highlight that undesirable changes may be invoked across other subsystems, such as at the laryngeal level. In particular, talkers with STN-DBS, who often demonstrate speech deterioration following DBS surgery, demonstrated more phonatory detriments at slowed speech rates. Findings have implications for speech rate candidacy considerations and speech motor control processes in PD.

4.
PLoS One ; 18(8): e0285009, 2023.
Article in English | MEDLINE | ID: mdl-37624795

ABSTRACT

During the COVID-19 pandemic, personal protective equipment such as facial masks and coverings were mandated all over the globe to protect against the virus. Although the primary aim of wearing face masks is to protect against viral transmission, they pose a potential burden on communication. The purpose of this scoping review was to identify the state of the evidence of the effect of facial coverings on acoustic and perceptual speech outcomes. The scoping review followed the framework created by Arksey & O'Malley (2005) and the Preferred Reporting Items for Systematic Reviews and Meta-Analyses Extension for Scoping Reviews guidelines (PRISMA-ScR; Tricco et al., 2018). The search was completed in May 2021 across the following databases: PubMed, EMBASE, PsycINFO, Web of Science, and Google Scholar. A total of 3,846 records were retrieved from the database search. Following the removal of duplicates, 3,479 remained for the title/abstract screen and 149 were selected for the full-text review. Of these, 52 were included in the final review and relevant data were extracted. The 52 articles included in the final review consisted of; 11 studied perceptual outcomes only, 16 studied acoustic outcomes only, and 14 studied both perceptual and acoustic outcomes. 13 of these investigated acoustic features that could be used for mask classification. Although the findings varied from article to article, many trends stood out. Many articles revealed that face masks act as a low pass filter, dampening sounds at higher frequencies; however, the frequency range and the degree of attenuation varied based on face mask type. All but five articles that reported on perceptual outcomes showed a common trend that wearing a face mask was associated with poorer speech intelligibility. The findings of the scoping review provided evidence that facial coverings negatively impacted speech intelligibility, which is likely due to a combination of auditory and visual cue degradation. Due to the continued prevalence of mask use, how facial coverings affect a wider variety of speaker populations, such as those with communication impairments, and strategies for overcoming communication challenges should be explored.


Subject(s)
COVID-19 , Masks , Humans , Acoustics , COVID-19/epidemiology , COVID-19/prevention & control , Pandemics , Speech Intelligibility
5.
Am J Speech Lang Pathol ; 32(5): 2282-2296, 2023 09 11.
Article in English | MEDLINE | ID: mdl-37625133

ABSTRACT

PURPOSE: The aim of this study was to quantify the combined effects of face masks and effortful speech styles on listener intelligibility and perceived listener effort in talkers with and without Parkinson's disease (PD). METHOD: Ten people with PD and 10 healthy, older controls read aloud sentences in two face mask and three speech style conditions. Masks included no mask and KN95 masks. Speech styles included habitual, clear, and loud. Listener participants were tasked with listening to each sentence mixed with background noise and then transcribing what they heard and rating how effortful it was to understand. Listener accuracy and effort were each modeled as a function of speaker group, face mask, and speech style using mixed-effects regression models. RESULTS: Listeners were less accurate and reported greater listening effort for the PD group and for the mask condition. Listeners were more accurate and reported less effort when listening to clear and loud compared to habitual speech. Listener accuracy and listener effort were strongly negatively correlated across all conditions. Face masks were also associated with a steeper decline in speech intelligibility and an increase in listener effort for talkers with PD. DISCUSSION: Face masks resulted in steeper speech intelligibility decline for talkers with PD compared to controls. Speaking more loudly or more clearly when wearing a face mask improved intelligibility for talkers with PD compared to habitual speech, and both speech styles resulted in speech intelligibility levels that approximated talkers' baseline intelligibility levels without a mask.


Subject(s)
Parkinson Disease , Speech Intelligibility , Humans , Masks , Speech Disorders , Cognition
6.
Am J Speech Lang Pathol ; 32(4S): 1850-1865, 2023 08 17.
Article in English | MEDLINE | ID: mdl-36958017

ABSTRACT

PURPOSE: The primary purpose of this study was to evaluate how individuals with hypophonia (HP; also referred to as HP participants) and their primary communication partners (PCPs; also referred to as PCP participants) rate communicative participation before and after experience with a speech amplification device. A secondary purpose was to evaluate pre- and post-device effects on self-rated communicative participation for each of the three speech amplification devices trialed outside of the laboratory. METHOD: Seventeen individuals with HP and their PCPs participated in a crossover design study that compared three different amplification devices: a wired belt-pack amplifier, a wireless stationary amplifier, and a personal frequency modulation (FM) system. Both the individuals with HP and their PCPs self-rated communicative participation at baseline and after trialing each device following 1-week device trial periods at home. Patient-reported outcome measures included the Communicative Effectiveness Survey (CES) and the Voice Activity and Participation Profile (VAPP). Following study completion, participants indicated whether they would like to select a specific device to continue using. RESULTS: Overall, HP participants rated communicative participation following device use higher than that in the pre-device condition, with the FM system resulting in the overall highest VAPP ratings and second highest CES ratings. Furthermore, HP and PCP participants rated these measures similarly. Finally, HP participants who selected a device to continue using self-reported lower total communicative effectiveness scores and greater voice activity limitations and participation restrictions at baseline in comparison to the nonselectors. CONCLUSIONS: This study contributes to an increased understanding of how communicative participation is experienced within this clinical population resulting from speech amplification. It is suggested that the inclusion of participation-based outcome measurement is essential to ensure a multidimensional and comprehensive approach to device prescription for individuals with HP.


Subject(s)
Dysphonia , Voice , Humans , Communication , Speech , Speech Disorders
7.
J Speech Lang Hear Res ; 66(8S): 3052-3075, 2023 08 17.
Article in English | MEDLINE | ID: mdl-36827515

ABSTRACT

PURPOSE: The purpose of this study is to quantify the combined effects of face masks and effortful speech styles on speech intensity, spectral moments, and measures of spectral balance in talkers with Parkinson's disease. METHOD: Fifteen people with Parkinson's disease and 15 healthy, older controls read aloud sentences in three face mask conditions and three speech style conditions. Mask conditions included no mask, surgical masks, and KN95 masks. Speech styles included habitual, clear, and loud. Acoustic measures of intensity, spectral moments, and spectral balance were modeled as a function of speaker group, mask, and speech style. RESULTS: Overall, talkers with PD demonstrated lower concentrations of high-frequency spectral energy in their speech. Face masks attenuated high-frequency energy, whereas clear followed by loud speaking styles amplified high frequencies. Overall, the attenuation observed by face masks was preserved across speech styles, and both mask and speech patterns were observed to be similar across groups. DISCUSSION: Clear and loud speech styles were effective in compensating for the damping effects of masks in talkers with and without PD. However, given that people with PD demonstrated poorer overall spectral balance compared to controls, the gains afforded by speaking clearly or loudly may be limited when wearing a face mask.


Subject(s)
Parkinson Disease , Humans , Parkinson Disease/complications , Speech Intelligibility , Speech Acoustics , Masks , Speech Production Measurement , Speech Disorders
8.
PLoS One ; 18(2): e0262504, 2023.
Article in English | MEDLINE | ID: mdl-36753529

ABSTRACT

Verb and action knowledge deficits are reported in persons with Parkinson's disease (PD), even in the absence of dementia or mild cognitive impairment. However, the impact of these deficits on combinatorial semantic processing is less well understood. Following on previous verb and action knowledge findings, we tested the hypothesis that PD impairs the ability to integrate event-based thematic fit information during online sentence processing. Specifically, we anticipated persons with PD with age-typical cognitive abilities would perform more poorly than healthy controls during a visual world paradigm task requiring participants to predict a target object constrained by the thematic fit of the agent-verb combination. Twenty-four PD and 24 healthy age-matched participants completed comprehensive neuropsychological assessments. We recorded participants' eye movements as they heard predictive sentences (The fisherman rocks the boat) alongside target, agent-related, verb-related, and unrelated images. We tested effects of group (PD/control) on gaze using growth curve models. There were no significant differences between PD and control participants, suggesting that PD participants successfully and rapidly use combinatory thematic fit information to predict upcoming language. Baseline sentences with no predictive information (e.g., Look at the drum) confirmed that groups showed equivalent sentence processing and eye movement patterns. Additionally, we conducted an exploratory analysis contrasting PD and controls' performance on low-motion-content versus high-motion-content verbs. This analysis revealed fewer predictive fixations in high-motion sentences only for healthy older adults. PD participants may adapt to their disease by relying on spared, non-action-simulation-based language processing mechanisms, although this conclusion is speculative, as the analyses of high- vs. low-motion items was highly limited by the study design. These findings provide novel evidence that individuals with PD match healthy adults in their ability to use verb meaning to predict upcoming nouns despite previous findings of verb semantic impairment in PD across a variety of tasks.


Subject(s)
Parkinson Disease , Humans , Aged , Comprehension , Language , Semantics , Neuropsychological Tests
9.
J Acoust Soc Am ; 151(5): 3359, 2022 05.
Article in English | MEDLINE | ID: mdl-35649889

ABSTRACT

This study quantified the effects of face masks on spectral speech acoustics in healthy talkers using habitual, loud, and clear speaking styles. Harvard sentence lists were read aloud by 17 healthy talkers in each of the 3 speech styles without wearing a mask, when wearing a surgical mask, and when wearing a KN95 mask. Outcome measures included speech intensity, spectral moments, and spectral tilt and energy in mid-range frequencies which were measured at the utterance level. Masks were associated with alterations in spectral density characteristics consistent with a low-pass filtering effect, although the effect sizes varied. Larger effects were observed for center of gravity and spectral variability (in habitual speech) and spectral tilt (across all speech styles). KN95 masks demonstrated a greater effect on speech acoustics than surgical masks. The overall pattern of the changes in speech acoustics was consistent across all three speech styles. Loud speech, followed by clear speech, was effective in remediating the filtering effects of the masks compared to habitual speech.


Subject(s)
Masks , Speech Intelligibility , Acoustics , Speech Acoustics , Speech Production Measurement
10.
J Speech Lang Hear Res ; 64(11): 4096-4123, 2021 11 08.
Article in English | MEDLINE | ID: mdl-34582276

ABSTRACT

Purpose The purpose of this study was to quantify changes in acoustic distinctiveness in two groups of talkers with Parkinson's disease as they modify across a wide range of speaking rates. Method People with Parkinson's disease with and without deep brain stimulation and older healthy controls read 24 carrier phrases at different speech rates. Target nonsense words in the carrier phrases were designed to elicit stop consonants and corner vowels. Participants spoke at seven self-selected speech rates from very slow to very fast, elicited via magnitude production. Speech rate was measured in absolute words per minute and as a proportion of each talker's habitual rate. Measures of segmental distinctiveness included a temporal consonant measure, namely, voice onset time, and a spectral vowel measure, namely, vowel articulation index. Results All talkers successfully modified their rate of speech from slow to fast. Talkers with Parkinson's disease and deep brain stimulation demonstrated greater baseline speech impairment and produced smaller proportional changes at the fast end of the continuum. Increasingly slower speaking rates were associated with increased temporal contrasts (voice onset time) but not spectral contrasts (vowel articulation). Faster speech was associated with decreased contrasts in both domains. Talkers with deep brain stimulation demonstrated more aberrant productions across all speaking rates. Conclusions Findings suggest that temporal and spectral segmental distinctiveness are asymmetrically affected by speaking rate modifications in Parkinson's disease. Talkers with deep brain stimulation warrant further investigation with regard to speech changes they make as they adjust their speaking rate.


Subject(s)
Parkinson Disease , Voice , Humans , Parkinson Disease/therapy , Phonetics , Speech , Speech Acoustics , Speech Intelligibility
11.
J Speech Lang Hear Res ; 64(6): 1773-1793, 2021 06 04.
Article in English | MEDLINE | ID: mdl-33950711

ABSTRACT

Purpose The aim of this study was to quantify changes in speech intelligibility in two cohorts of people with Parkinson's disease (PD; those with and without deep brain stimulation [DBS]) across a broad range of self-selected speech rate alterations in (a) read sentences and (b) extemporaneous speech (monologues). Method Four speaker groups participated in this study: younger and older controls, people with PD undergoing standard pharmaceutical treatment, and people with PD and DBS. Naïve listeners rated the intelligibility of read sentences and extemporaneous monologues, spoken by participants at seven self-selected speech rates from very slow to very fast. Intelligibility was modeled as a function of group, speech rate condition, and speech task. Results Overall, compared to habitual speech rate, slower speech rate conditions were not associated with changes in speech intelligibility, whereas faster-than-habitual conditions were associated in declines in intelligibility. Results were mediated by group and task effects, such that talkers with PD and DBS were more likely to see intelligibility benefits at slower self-selected speech rates and less likely to see detriments at faster rates, and these differences were amplified in monologues compared to sentences. Conclusion Findings suggest differences in the ways in which slower and faster speech rate adjustments impact speech intelligibility in people with PD with and without DBS, with the latter demonstrating greater magnitudes of change.


Subject(s)
Communication Disorders , Parkinson Disease , Humans , Language , Speech Disorders , Speech Intelligibility
12.
J Speech Lang Hear Res ; 63(8): 2695-2712, 2020 08 10.
Article in English | MEDLINE | ID: mdl-32755496

ABSTRACT

Purpose This study compared the performance of three amplification devices hypothesized to improve speech communication in individuals with hypophonia (HP), as well as to identify individuals' device preferences. Method Twenty-two individuals with HP and their primary communication partners participated in a cross-over design study comparing three different speech amplification devices: a wired portable amplifier (Device A), a wireless stationary amplifier (Device B), and a one-way personal communication system (Device C). Participants attended one laboratory visit followed by 1-week trial periods with each device. At the first visit, HP participants completed speech tasks with and without the devices, in quiet and in noise. Following the in-laboratory test period, participants trialed each device at home for approximately 1 week per device. Following completion of the study, participants indicated whether or not they would like to continue using a device. Results Overall, in the presence of noise, all three devices demonstrated significant improvements in speech-to-noise levels and speech intelligibility compared to no device. A clear device hierarchy emerged such that the personal communication device (Device C) was associated with significantly better speech outcomes compared to the other two devices. The majority of participants elected to continue using a device at the completion of the study. Device preferences, however, did not clearly reflect the objective device hierarchy that was found for the objective speech measures. Each of the three devices was selected as a preferred device by at least three participants at the completion of the study. Conclusion Results from this study demonstrated clear differences in device performance in three distinct forms of amplification devices for individuals with HP. Findings suggest that amplification device use may be beneficial for this clinical population and underscore the potential to improve device availability and device selection criteria in future research. Supplemental Material https://doi.org/10.23641/asha.12735875.


Subject(s)
Speech Perception , Humans , Noise , Speech Intelligibility
13.
Can J Neurol Sci ; 47(5): 634-641, 2020 09.
Article in English | MEDLINE | ID: mdl-32389143

ABSTRACT

OBJECTIVE: The purpose of this study was to examine the effectiveness, satisfaction, and acceptance of a low-cost Lombard-response (LR) device in a group of individuals with Parkinson's disease (IWPD) and their communication partners (CPs). METHOD: Sixteen IWPD and hypophonia and their CPs participated in the study. The IWPD wore a LR device that included a small MP3 player (Sony Walkman) and headphones playing a multi-talker noise audio file at 80 dB during lab-based speech tasks and during their daily conversational speech over a 2-week device trial period. Outcome measures included average conversational speech intensity and scores on a questionnaire related to speech impairment, communication effectiveness, and device satisfaction. RESULTS: Conversational speech intensity of the IWPD is increased by 7 to 10 dB with the LR device. Following a 2-week trial period, eight of the IWPD (50%) gave the LR device moderate-to-high satisfaction and effectiveness ratings and decided to purchase the device for long-term daily use. At the 4-month follow-up, none of the IWPDs were still using the LR device. Device rejection was related to discomfort (loudness), headaches, interference with cognition, and difficulty controlling device. CONCLUSION: Short-term acceptance and satisfaction with the LR device was moderate, but long-term acceptance, beyond 4 months, was absent. Future studies are required to determine if other types of low-cost LR devices can be developed that improve long-term efficacy and device acceptance in IWPD and hypophonia.


Subject(s)
Parkinson Disease , Communication , Headache , Humans , Parkinson Disease/complications , Parkinson Disease/therapy , Speech , Speech Disorders
14.
Can J Neurol Sci ; 46(3): 287-294, 2019 05.
Article in English | MEDLINE | ID: mdl-30905324

ABSTRACT

OBJECTIVE: To systematically evaluate how different deep brain stimulation of the subthalamic nucleus (STN-DBS) amplitude, frequency, and pulse-width electrical parameter settings impact speech intensity, voice quality, and prosody of speech in Parkinson's disease (PD). METHODS: Ten individuals with PD receiving bilateral STN-DBS treatments were seen for three baseline and five treatment visits. The five treatment visits involved an examination of the standard clinical settings as well as manipulation of different combinations of frequency (low, mid, and high), pulse width (low, mid, and high), and voltage (low, mid, and high) of stimulation. Measures of speech intensity, jitter, shimmer, harmonics-noise ratio, semitone standard deviation, and listener ratings of voice quality and prosody were obtained for each STN-DBS manipulation. RESULTS: The combinations of lower frequency, lower pulse width, and higher voltage settings were associated with improved speech outcomes compared to the current standard clinical settings. In addition, decreased total electrical energy delivered to the STN appears to be associated with speech improvements. CONCLUSIONS: This study provides preliminary evidence that STN-DBS may be optimized for Parkinson-related problems with voice quality, speech intensity, and prosody of speech.


Subject(s)
Deep Brain Stimulation/methods , Parkinson Disease/therapy , Speech/physiology , Subthalamic Nucleus/physiology , Voice Quality/physiology , Aged , Female , Humans , Male , Middle Aged , Parkinson Disease/complications , Speech Disorders/etiology
15.
J Speech Lang Hear Res ; 61(10): 2487-2501, 2018 10 26.
Article in English | MEDLINE | ID: mdl-30458531

ABSTRACT

Purpose: Heterogeneous child speech was force-aligned to investigate whether (a) manipulating specific parameters could improve alignment accuracy and (b) forced alignment could be used to replicate published results on acoustic characteristics of /s/ production by children. Method: In Part 1, child speech from 2 corpora was force-aligned with a trainable aligner (Prosodylab-Aligner) under different conditions that systematically manipulated input training data and the type of transcription used. Alignment accuracy was determined by comparing hand and automatic alignments as to how often they overlapped (%-Match) and absolute differences in duration and boundary placements. Using mixed-effects regression, accuracy was modeled as a function of alignment conditions, as well as segment and child age. In Part 2, forced alignments derived from a subset of the alignment conditions in Part 1 were used to extract spectral center of gravity of /s/ productions from young children. These findings were compared to published results that used manual alignments of the same data. Results: Overall, the results of Part 1 demonstrated that using training data more similar to the data to be aligned as well as phonetic transcription led to improvements in alignment accuracy. Speech from older children was aligned more accurately than younger children. In Part 2, /s/ center of gravity extracted from force-aligned segments was found to diverge in the speech of male and female children, replicating the pattern found in previous work using manually aligned segments. This was true even for the least accurate forced alignment method. Conclusions: Alignment accuracy of child speech can be improved by using more specific training and transcription. However, poor alignment accuracy was not found to impede acoustic analysis of /s/ produced by even very young children. Thus, forced alignment presents a useful tool for the analysis of child speech. Supplemental Material: https://doi.org/10.23641/asha.7070105.


Subject(s)
Speech/physiology , Age Factors , Child , Child Language , Child, Preschool , Female , Humans , Male , Models, Statistical , Phonetics , Speech Acoustics , Speech Production Measurement/methods , Speech Recognition Software
16.
J Speech Lang Hear Res ; 61(3): 510-524, 2018 03 15.
Article in English | MEDLINE | ID: mdl-29471373

ABSTRACT

Purpose: The settings of 3 electrical stimulation parameters were adjusted in 12 speakers with Parkinson's disease (PD) with deep brain stimulation of the subthalamic nucleus (STN-DBS) to examine their effects on vowel acoustics and speech intelligibility. Method: Participants were tested under permutations of low, mid, and high STN-DBS frequency, voltage, and pulse width settings. At each session, participants recited a sentence. Acoustic characteristics of vowel production were extracted, and naive listeners provided estimates of speech intelligibility. Results: Overall, lower-frequency STN-DBS stimulation (60 Hz) was found to lead to improvements in intelligibility and acoustic vowel expansion. An interaction between speaker sex and STN-DBS stimulation was found for vowel measures. The combination of low frequency, mid to high voltage, and low to mid pulse width led to optimal speech outcomes; however, these settings did not demonstrate significant speech outcome differences compared with the standard clinical STN-DBS settings, likely due to substantial individual variability. Conclusions: Although lower-frequency STN-DBS stimulation was found to yield consistent improvements in speech outcomes, it was not found to necessarily lead to the best speech outcomes for all participants. Nevertheless, frequency may serve as a starting point to explore settings that will optimize an individual's speech outcomes following STN-DBS surgery. Supplemental Material: https://doi.org/10.23641/asha.5899228.


Subject(s)
Deep Brain Stimulation/methods , Parkinson Disease/therapy , Phonetics , Speech Acoustics , Speech Intelligibility , Aged , Female , Humans , Male , Middle Aged , Parkinson Disease/physiopathology , Speech Intelligibility/physiology , Subthalamic Nucleus , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL