Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 150
Filter
1.
Eur Radiol ; 2024 Jul 17.
Article in English | MEDLINE | ID: mdl-39014088

ABSTRACT

OBJECTIVES: To investigate whether ultrafast sequence improves the diagnostic performance of conventional dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) in differentiating additional suspicious lesions (ASLs) on preoperative breast MRI. MATERIALS AND METHODS: A retrospective database search identified 668 consecutive patients who underwent preoperative breast DCE-MRI with ultrafast sequence between June 2020 and July 2021. Among these, 107 ASLs from 98 patients with breast cancer (36 multifocal, 42 multicentric, and 29 contralateral) were identified. Clinical, pathological, conventional MRI findings, and ultrafast sequence-derived parameters were collected. A prediction model that adds ultrafast sequence-derived parameters to clinical, pathological, and conventional MRI findings was developed and validated internally. Decision curve analysis and net reclassification index statistics were performed. A nomogram was constructed. RESULTS: The ultrafast model adding time to peak enhancement, time to enhancement, and maximum slope showed a significantly increased area under the receiver operating characteristic curve compared with the conventional model which includes age, human epidermal growth factor receptor 2 expression of index cancer, size of index cancer, lesion type of index cancer, location of ASL, and size of ASL (0.92 vs. 0.82; p = 0.002). The decision curve analysis showed that the ultrafast model had a higher overall net benefit than the conventional model. The net reclassification index of ultrafast model was 23.3% (p = 0.001). CONCLUSION: A combination of ultrafast sequence-derived parameters with clinical, pathological, and conventional MRI findings can aid in the differentiation of ASL on preoperative breast MRI. CLINICAL RELEVANCE STATEMENT: Our prediction model and nomogram that was based on ultrafast sequence-derived parameters could help radiologists differentiate ASLs on preoperative breast MRI. KEY POINTS: Ultrafast MRI can diminish background parenchymal enhancement and possibly improve diagnostic accuracy for additional suspicious lesions (ASLs). Location of ASL, larger size of ASL, and higher maximum slope were associated with malignant ASL. The ultrafast model and nomogram can help preoperatively differentiate additional malignancies.

2.
Foods ; 13(8)2024 Apr 17.
Article in English | MEDLINE | ID: mdl-38672900

ABSTRACT

Natural phytochemicals are well known to protect against numerous metabolic disorders. Anthocyanins are vacuolar pigments belonging to the parent class of flavonoids. They are well known for their potent antioxidant and gut microbiome-modulating properties, primarily responsible for minimizing the risk of cardiovascular diseases, diabetes, obesity, neurodegenerative diseases, cancer, and several other diseases associated with metabolic syndromes. Berries are the primary source of anthocyanin in the diet. The color and stability of anthocyanins are substantially influenced by external environmental conditions, constraining their applications in foods. Furthermore, the significantly low bioavailability of anthocyanins greatly diminishes the extent of the actual health benefits linked to these bioactive compounds. Multiple strategies have been successfully developed and utilized to enhance the stability and bioavailability of anthocyanins. This review provides a comprehensive view of the recent advancements in chemistry, biosynthesis, dietary sources, stabilization, bioavailability, industrial applications, and health benefits of anthocyanins. Finally, we summarize the prospects and challenges of applications of anthocyanin in foods.

3.
Quant Imaging Med Surg ; 14(4): 2946-2954, 2024 Apr 03.
Article in English | MEDLINE | ID: mdl-38617152

ABSTRACT

Background: Despite the common use of ultrasound (US)-guided fine-needle aspiration (FNA) for axillary node (AN) in breast cancer patients, only a limited number of studies are available regarding the diagnostic performance of AN-FNA according to the suspicion level based on US findings. This study compares the outcomes of US-guided AN-FNA in breast cancer patients, differentiating between those undergoing staging and surveillance. Methods: A cross-sectional retrospective study with retrospective analysis was conducted on 767 consecutive AN-FNA procedures performed in 2017 at Samsung Medical Center in Seoul, with 654 for staging and 113 for surveillance in breast cancer patients. The radiologists performed axillary US and the specific finding was prospectively classified into the AN-reporting and data system (AN-RADS) category 3-5 before FNA. The malignancy rate of each category was evaluated. The chi-square test, with or without Bonferroni correction, or Fisher's exact test was used to compare the malignancy rates between the staging and surveillance groups for each category. Results: Among the 767 AN-FNAs, 424 (55.3%) were malignant. The malignancy rate was significantly higher in the staging group (59.5%) than in the surveillance group (31.0%, P<0.0001). The distribution of AN-RADS categories differed between the groups (P=0.015), with 4A being the most common. The malignancy rates in categories 3, 4A, 4B, 4C, and 5 were as follows: 5.6%, 36.0%, 77.4%, 87.7%, and 98.4% in the staging group, and 0.0%, 9.7%, 53.3%, 88.9%, and 100% in the surveillance group. The malignancy rate was significantly different between the two groups only in category 4A (P=0.0001). Conclusions: AN-FNA according to AN-RADS category appears to be an appropriate method for determination of axillary nodal status. Overall malignancy rate of AN-FNA in breast cancer patients was higher in the staging group than in the surveillance group. According to the suspicion level, the difference between two groups was significant only in category 4A.

4.
Diagnostics (Basel) ; 13(17)2023 Aug 29.
Article in English | MEDLINE | ID: mdl-37685338

ABSTRACT

Rationale and Objective: To evaluate the characteristic clinical and imaging findings of charcoal granuloma and suggest features that may differentiate charcoal granuloma from breast cancer. Materials and Methods: This retrospective study included 18 patients with a histologically confirmed breast charcoal granuloma between 2005 and 2021 at a single institution. All patients had a history of breast surgery after ultrasound (US)-guided charcoal marking. Two radiologists analyzed the radiologic findings of charcoal granulomas, including the presence of a mass or calcification; the shape, margin and density of the masses on mammography; and the location, size, shape, margin, orientation, echogenicity, vascularity, presence of an echogenic halo, and posterior acoustic shadowing on US. In cases with available follow-up images, we also investigated whether the size and shape had changed. Results: The median interval between breast surgery and the diagnosis of charcoal granuloma was 2.3 years (range, 0.7-18.3 years). Thirteen lesions (72.2%) were detected on screening images. In 11 (61.1%) cases, the surgical incision was not made in the tattooed skin area. Mammography showed positive findings in 10/15 patients, and most lesions were isodense masses (70%). There were no cases with calcification. On US, all lesions were masses and showed a taller-than-wide orientation (61.1%), round or oval shape (55.6%), and iso- or hyperechogenicity (83.3%). Echogenic halo (27.8%) and posterior acoustic shadowing (16.7%) were uncommon. On Doppler US, only four cases (22.2%) showed increased vascularity. Most were classified as BI-RADS 3 (38.9%) or 4A (50.0%). After biopsy, 12 patients had follow-up mammography and US. The size of the lesion decreased in nine cases and remained unchanged in three cases. A decrease in the lesion size after biopsy showed a negative correlation with the interval between detection on imaging and biopsy (p = 0.04). Conclusion: Charcoal granuloma is most commonly found 2-3 years after surgery and occurs more frequently when the incision site is different from the tattooed skin area. US findings of tall and round or oval masses with iso- or hyperechogenicity without increased vascularity could help to differentiate them from malignancies.

5.
Yonsei Med J ; 64(10): 633-640, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37727923

ABSTRACT

PURPOSE: To compare the prognosis of patients with axillary adenocarcinoma from an unknown primary (ACUPax) origin with negative MRI results and those with MRI-detected primary breast cancers. MATERIALS AND METHODS: The breast MRI images of 32 patients with ACUPax without signs of primary breast cancer on mammography and ultrasound (US) were analyzed. Spot compression-magnification mammography and second-look US were performed for the area of MRI abnormality in patients with positive results; any positive findings corresponding to the MRI abnormality were confirmed by biopsy. If suspicious MRI lesions could not be localized on mammography or US, MR-guided biopsy or excision biopsy after MR-guided localization was performed. We compared the prognosis of patients with negative breast MRI with that for patients with MRI-detected primary breast cancers. RESULTS: Primary breast cancers were confirmed in 8 (25%) patients after breast MRI. Primary breast cancers were not detected on MRI in 24 (75%) patients, including five cases of false-positive MRI results. Twenty-three patients underwent axillary lymph node dissection (ALND) followed by whole breast radiation therapy (WBRT) and chemotherapy (n=17) or subsequent chemotherapy only (n=2). Recurrence or distant metastasis did not occur during follow up in 7/8 patients with MRI-detected primary breast cancers and 22/24 patients with negative MRI results. Regional recurrence or distant metastasis did not occur in any MR-negative patient who received adjuvant chemotherapy after ALND and WBRT. CONCLUSION: The prognoses of MR-negative patients with ACUPax who received ALND and WBRT followed by chemotherapy were as good as those of patients with MRI-detected primary breast cancers.


Subject(s)
Adenocarcinoma , Neoplasms, Unknown Primary , Humans , Lymphatic Metastasis/diagnostic imaging , Neoplasms, Unknown Primary/diagnostic imaging , Radiography , Magnetic Resonance Imaging , Prognosis
6.
Eur Radiol ; 33(10): 7186-7198, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37188881

ABSTRACT

OBJECTIVE: To investigate whether artificial intelligence-based computer-aided diagnosis (AI-CAD) can improve radiologists' performance when used to support radiologists' interpretation of digital mammography (DM) in breast cancer screening. METHODS: A retrospective database search identified 3158 asymptomatic Korean women who consecutively underwent screening DM between January and December 2019 without AI-CAD support, and screening DM between February and July 2020 with image interpretation aided by AI-CAD in a tertiary referral hospital using single reading. Propensity score matching was used to match the DM with AI-CAD group in a 1:1 ratio with the DM without AI-CAD group according to age, breast density, experience level of the interpreting radiologist, and screening round. Performance measures were compared with the McNemar test and generalized estimating equations. RESULTS: A total of 1579 women who underwent DM with AI-CAD were matched with 1579 women who underwent DM without AI-CAD. Radiologists showed higher specificity (96% [1500 of 1563] vs 91.6% [1430 of 1561]; p < 0.001) and lower abnormal interpretation rates (AIR) (4.9% [77 of 1579] vs 9.2% [145 of 1579]; p < 0.001) with AI-CAD than without. There was no significant difference in the cancer detection rate (CDR) (AI-CAD vs no AI-CAD, 8.9 vs 8.9 per 1000 examinations; p = 0.999), sensitivity (87.5% vs 77.8%; p = 0.999), and positive predictive value for biopsy (PPV3) (35.0% vs 35.0%; p = 0.999) according to AI-CAD support. CONCLUSIONS: AI-CAD increases the specificity for radiologists without decreasing sensitivity as a supportive tool in the single reading of DM for breast cancer screening. CLINICAL RELEVANCE STATEMENT: This study shows that AI-CAD could improve the specificity of radiologists' DM interpretation in the single reading system without decreasing sensitivity, suggesting that it can benefit patients by reducing false positive and recall rates. KEY POINTS: • In this retrospective-matched cohort study (DM without AI-CAD vs DM with AI-CAD), radiologists showed higher specificity and lower AIR when AI-CAD was used to support decision-making in DM screening. • CDR, sensitivity, and PPV for biopsy did not differ with and without AI-CAD support.


Subject(s)
Artificial Intelligence , Breast Neoplasms , Humans , Female , Cohort Studies , Retrospective Studies , Mammography/methods , Breast Neoplasms/diagnostic imaging , Early Detection of Cancer/methods , Computers , Mass Screening/methods
8.
J Korean Soc Radiol ; 84(2): 398-408, 2023 Mar.
Article in English | MEDLINE | ID: mdl-37051396

ABSTRACT

Purpose: This study aimed to evaluate the radiological and clinical characteristics of benign adenomyoepitheliomas of the breast. Materials and Methods: Over the last 20 years, 120 patients were histologically diagnosed with breast adenomyoepithelioma (AME) at our institution. We excluded 43 patients who were incidentally diagnosed during mastectomy for breast cancer, 28 who underwent percutaneous biopsy without further excision, and 8 who had biopsy-confirmed benign AME and were found to have another pathology after complete excision. We retrospectively reviewed the clinical records and radiological findings of the remaining 41 patients with histologically diagnosed benign breast AMEs after complete excision. Results: All 41 patients underwent US; 38 underwent mammography (MG) and US; and 18 underwent MG, US, and MRI. MG detected 38 cases with a round or oval shape (56%), and mass (89%), were non-circumscribed (62%), hyperdense (53%), and without microcalcifications (95%). Breast US revealed suspicious masses (98%) with a non-circumscribed margin (66%), hypoechogenicity (43%), and intratumoral vascularity (63%). All lesions on breast MRI showed suspicious masses (100%) with ill-defined margins (61%), and 84% showed wash-out kinetics. Benign AMEs showed suspicious features of Breast Imaging Reporting and Data System (BI-RADS) category 4 or 5 in 83%-95% of the MG, US, and MRI. Sixteen of the 41 cases were misdiagnosed on the initial core needle biopsy and two were diagnosed as malignancy. Conclusion: Benign breast AME often shows suspicious radiological features mimicking a malignant mass on MG, US, and MRI. Differentiating benign AME from other pathologies might be difficult on core needle biopsy, and complete excision is needed for a correct diagnosis.

9.
J Korean Soc Radiol ; 84(2): 332-344, 2023 Mar.
Article in Korean | MEDLINE | ID: mdl-37051398

ABSTRACT

The role of ultrasound-guided interventions in the diagnosis and treatment of breast lesions is gaining importance and prevalence, particularly as the instances of non-palpable breast lesion detection, breast-conserving surgery, and neoadjuvant chemotherapy are increasing. This review attempts to summarize the types and techniques of breast ultrasound-guided interventional procedures, such as biopsy, tissue marker insertion, and preoperative localization, and their indications. Furthermore, we highlight the pro and cons of the most commonly used procedures with the intention of promoting their use in clinical practice.

10.
Radiology ; 307(4): e222435, 2023 05.
Article in English | MEDLINE | ID: mdl-37097135

ABSTRACT

Background Automated breast (AB) US effectively depicts mammographically occult breast cancers in Western women. However, few studies have focused on the outcome of supplemental AB US in Asian women who have denser breasts than Western women. Purpose To evaluate the performance of supplemental AB US on mammography-based breast cancer screening in Asian women with dense breasts and those with nondense breasts. Materials and Methods A retrospective database search identified asymptomatic Korean women who underwent digital mammography (DM) and supplemental AB US screening for breast cancer between January 2018 and December 2019. We excluded women without sufficient follow-up, established final diagnosis, or histopathologic results. Performance measures of DM alone and AB US combined with DM (hereafter AB US plus DM) were compared. The primary outcome was cancer detection rate (CDR), and the secondary outcomes were sensitivity and specificity. Subgroup analyses were performed based on mammography density. Results From 2785 screening examinations in 2301 women (mean age, 52 years ± 9 [SD]), 28 cancers were diagnosed (26 screening-detected cancers, two interval cancers). When compared with DM alone, AB US plus DM resulted in a higher CDR of 9.3 per 1000 examinations (95% CI: 7.7, 10.3) versus 6.5 per 1000 examinations (95% CI: 5.2, 7.2; P < .001) and a higher sensitivity of 90.9% (95% CI: 77.3, 100.0) versus 63.6% (95% CI: 40.9, 81.8; P < .001) but a lower specificity of 86.8% (95% CI: 85.2, 88.2) versus 94.6% (95% CI: 93.6, 95.5; P < .001) in women with dense breasts. In women with nondense breasts, AB US plus DM resulted in a higher CDR of 9.5 per 1000 examinations (95% CI: 7.1, 10.6) versus 6.3 per 1000 examinations (95% CI: 3.5, 7.1; P < .001), whereas specificity was lower at 95.2% (95% CI: 93.4, 96.8) versus 97.1% (95% CI: 95.8, 98.4; P < .001). Conclusion In Asian women, the addition of automated breast US to digital mammography showed higher cancer detection rates but lower specificities in both dense and nondense breasts. © RSNA, 2023 Supplemental material is available for this article.


Subject(s)
Breast Neoplasms , Breast , Humans , Middle Aged , Female , Retrospective Studies , Breast/diagnostic imaging , Breast/pathology , Breast Neoplasms/pathology , Mammography/methods , Breast Density , Mass Screening/methods , Early Detection of Cancer/methods
12.
Foods ; 12(6)2023 Mar 19.
Article in English | MEDLINE | ID: mdl-36981238

ABSTRACT

Fruits and vegetables are a vital source of redox-active phytochemicals in the diet. Traditional green leafy vegetables (GLVs) are a rich source of carotenoids, dietary fiber, minerals, phenols, vitamins, and tocopherols and are commonly consumed in rural areas worldwide. In traditional Korean medicine, many GLVs are used to treat various ailments. However, data on the carotenoid and tocopherol content of many traditional GLVs consumed in the Republic of Korea are insufficient. The current work aims to compare the carotenoid and tocopherol profiles of 18 traditional GLVs by utilizing a single ion monitoring LC-MS approach to identify the potential GLVs for commercial cultivation and healthy diet formulations. Among the traditional GLVs investigated, (all-E)-lutein was the most abundant carotenoid, ranging from 44.4% in Glehnia littoralis to 52.1% in Heracleum moellendorffii. It was followed by (all-E)-violaxanthin and (all-E)-ß-carotene. The highest contents of (all-E)-violaxanthin (75.6 µg/g FW), 9-Z-neoxanthin (48.4 µg/g FW), (all-E)-luteoxanthin (10.8 µg/g FW), (all-E)-lutein (174.1 µg/g FW), total xanthophylls (310.5 µg/g FW), (all-E)-ß-carotene (69.6 µg/g FW), and total carotenoids (380.1 µg/g FW) were recorded in Pimpinella brachycarpa. Surprisingly, Taraxacum mongolicum also showed the highest contents of (all-E)-violaxanthin, (all-E)-lutein, and total carotenoids, which were statistically non-significant (p > 0.05, Tukey HSD) with P. brachycarpa. The highest concentration of (all-E)-zeaxanthin (14.4 µg/g FW) was recorded in Solidago virga-aurea. Among the studied herbs, 13.9 (H. moellendorffii)-133.6 µg/g FW (Toona sinensis) of α-tocopherol was recorded. Overall, the results suggest that P. brachycarpa and T. mongolicum are rich sources of carotenoids. On the other hand, T. sinensis is a rich source of α-tocopherol. These GLVs can be utilized in the diet to enhance the intake of health-beneficial carotenoids and α-tocopherol.

13.
J Breast Cancer ; 26(1): 77-85, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36852967

ABSTRACT

We present our initial experience of ultrasound (US)-guided localization of clipped metastatic axillary lymph nodes (LNs) following neoadjuvant chemotherapy (NAC). We evaluated US visibility and the successful excision rate of clipped LN after NAC in 29 consecutive patients with breast cancer. US-guided localization of clipped nodes was performed in 22 patients on the day of surgery, while seven patients underwent surgery without localization. The clips were identified in all patients with residual metastatic LNs and 6 of 12 (50%) patients without residual metastatic LNs on US. Six patients without visible clips underwent US-guided localization at the presumed previous clip insertion site. The successful excision rate of 22 LNs with localization was 100% (even though 3 of them were non-sentinel LNs) and 57% (4/7) without localization. Regardless of the presence of visible residual metastatic LNs on US after NAC, successful excision of the clipped LN with US-guided localization is feasible.

14.
Sci Rep ; 13(1): 1811, 2023 02 01.
Article in English | MEDLINE | ID: mdl-36725965

ABSTRACT

In this study, we aimed to evaluate the benefits and losses of mammography with and without implant displacement (ID) and propose an appropriate imaging protocol for the screening of breasts with implants. We evaluated mammograms of 162 breasts in 96 patients including 71 breasts with biopsy-proven cancers. Mammography of each breast included standard MLO and ID MLO images. We reviewed the mammograms using clinical image quality criteria, which consist of parameters that evaluate the proper positioning of the breast and the image resolution. Standard MLO images showed significantly higher scores for proper positioning but showed significantly lower scores for image resolution than the ID MLO images. Moreover, standard MLO images showed significantly higher kVp, mAs, and compressed breast thickness than the ID MLO images. The organ dose was also higher in the standard MLO images than in the ID MLO images, but the difference was not statistically significant. In mammography with proven cancer, ID MLO images showed significantly higher degree of cancer visibility than standard MLO images. For screening mammography in patients with breast implants, ID MLO view alone is sufficient for MLO projection with reducing the patient's radiation dose without compromising the breast cancer detection capability, especially in dense breasts with subpectoral implants.


Subject(s)
Breast Implants , Breast Neoplasms , Female , Humans , Breast/diagnostic imaging , Breast Neoplasms/diagnostic imaging , Breast Neoplasms/surgery , Early Detection of Cancer , Mammography/methods
15.
Ultrasonography ; 42(1): 31-40, 2023 Jan.
Article in English | MEDLINE | ID: mdl-36353790

ABSTRACT

PURPOSE: The aim of this study was to evaluate the diagnostic value of shear-wave elastography (SWE) combined with Doppler ultrasonography (US) in selecting equivocal breast fibroepithelial lesions (FELs) for follow-up without further excision. METHODS: A retrospective analysis was conducted of 88 patients with equivocal breast FELs (FELs with the possibility of both fibroadenoma [FA] and phyllodes tumor [PT]) diagnosed by core needle biopsy (CNB). For post-CNB treatment, surgical or vacuum-assisted excision was performed on 88 equivocal FELs, of which 56 were diagnosed as FAs and 32 as PTs on histopathology. Mean elasticity (Emean) and vascularity were determined using SWE and Doppler US. The diagnostic performances of B-mode US, SWE, and Doppler US were calculated to differentiate FAs and PTs in the excised equivocal FELs. RESULTS: In the excised equivocal FELs diagnosed by CNB, FAs showed significantly lower median Emean values (36.4 vs. 66.7 kPa, P=0.005) and more frequent low vascularity (0-1 vessel flow signal) (P<0.001) than PTs. For the differentiation of FAs and PTs, the combination of Emean of >60.9 kPa and high vascularity (≥2 vessel flows) showed a sensitivity and negative predictive value of 100%, as well as better performance in other diagnostic values than B-mode US alone (Breast Imaging Reporting and Data System ≥4A) (all P<0.05). CONCLUSION: Equivocal breast FELs showing both low elasticity and low vascularity were not upgraded to PTs upon further excision. Therefore, the combination of SWE and color Doppler US mode might help select patients with equivocal FELs for whom further excision is unnecessary.

16.
Medicine (Baltimore) ; 101(50): e31836, 2022 Dec 16.
Article in English | MEDLINE | ID: mdl-36550794

ABSTRACT

To evaluate the frequency and location of abnormal lymph nodes (LNs) in breast cancer patients with a single axillary lymph node (ALN) metastasis on breast magnetic resonance imaging (MRI). We retrospectively reviewed the MRI findings of 219 consecutive patients with breast cancer with single ALN metastasis who were surgically confirmed at our institution between January 2018 and December 2018. The morphological features and locations of the abnormal LN on MRI were analyzed. Pathology reports were reviewed to evaluate the size of the metastases and whether they were sentinel LNs (SLNs). Of the 219 patients with a single ALN metastasis, 56 (25.6%) showed abnormal MRI findings. Of these, 54 (96.4%) had either the lowest or second-lowest LN in the level I axilla. In 184 (91.5%) of 201 patients who underwent SLN biopsy, the metastatic LN were SLN. Macrometastases were found more frequently in cases with abnormal LNs than in those with normal-looking LNs (P = .004). The most frequent morphological feature of metastatic ALNs was a diffuse cortical thickening of 3 to 5 mm (37.5%). Although MRI findings of single ALN metastasis in breast cancer patients are none or minimal, abnormalities are observed in the lowest or second-lowest LN in the lower axilla when present, suggesting the location of the SLNs.


Subject(s)
Breast Neoplasms , Humans , Female , Breast Neoplasms/pathology , Sentinel Lymph Node Biopsy/methods , Lymphatic Metastasis/diagnostic imaging , Lymphatic Metastasis/pathology , Axilla/pathology , Retrospective Studies , Lymph Nodes/diagnostic imaging , Lymph Nodes/pathology , Lymph Node Excision , Magnetic Resonance Imaging
17.
Foods ; 11(24)2022 Dec 08.
Article in English | MEDLINE | ID: mdl-36553719

ABSTRACT

This study determined the effects of physicochemical and microbial properties of emulsion as a fat replacer in meat analogs during freezing storage. Meat analogs were prepared with different fat replacers: vegetable oil (O) for control, oil in water emulsion (E), and non-emulsified oil in water emulsion (EC) for emulsion control. After that, meat analogs were stored for 0.5, one, three, and six months at −18 °C and −60 °C. The results showed that the drip loss of all samples was not significantly different (p > 0.05). However, the liquid holding capacity of EC and E was significantly higher than that of O (p < 0.05). Additionally, the microstructures of meat analogs of E and EC were smaller with denser pore sizes than O. This explains the significantly lower hardness of E and EC compared to O (p < 0.05). Overall, E showed superior physiochemical and sensory quality. During the storage, the stability of chemical properties, such as volatile basic nitrogen and thiobarbituric acid reactive substances, showed no significant changes (p > 0.05). Moreover, the microbial studies (total viable counts and Escherichia coli count) suggested that meat analogs did not deteriorate during the preparation and storage. Thus, this study suggests that emulsion-type fat replacers influence meat analogs' physicochemical and sensorial properties. However, these properties are not influenced by the storage temperature and duration.

18.
Taehan Yongsang Uihakhoe Chi ; 83(3): 632-644, 2022 May.
Article in English | MEDLINE | ID: mdl-36238508

ABSTRACT

Purpose: To determine the incidence of atypical ductal hyperplasia (ADH) in needle biopsy and the upgrade rate to carcinoma, and to evaluate difference in findings between the upgrade and non-upgrade groups. Materials and Methods: Among 9660 needle biopsies performed over 48 months, we reviewed the radiologic and histopathologic findings of ADH and compared the differences in imaging findings (mammography and breast US) and biopsy methods between the upgrade and non-upgrade groups. Results: The incidence of ADH was 1.7% (169/9660). Of 112 resected cases and 30 cases followed-up for over 2 years, 35 were upgraded to carcinoma (24.6%, 35/142). The upgrade rates were significantly different according to biopsy methods: US-guided core needle biopsy (US-CNB) (40.7%, 22/54) vs. stereotactic-vacuum-assisted biopsy (S-VAB) (16.0%, 12/75) vs. US-guided VAB (US-VAB) (7.7%, 1/13) (p = 0.002). Multivariable analysis showed that only US-CNB (odds ratio = 5.19, 95% confidence interval: 2.16-13.95, p < 0.001) was an independent predictor for pathologic upgrade. There was no upgrade when a sonographic mass was biopsied by US-VAB (n = 7). Conclusion: The incidence of ADH was relatively low (1.7%) and the upgrade rate was 24.6%. Surgical excision should be considered because of the considerable upgrade rate, except in the case of US-VAB.

19.
Taehan Yongsang Uihakhoe Chi ; 83(3): 620-631, 2022 May.
Article in English | MEDLINE | ID: mdl-36238525

ABSTRACT

Purpose: This study aimed to investigate the diagnostic performance of features suggestive of nodal metastasis on preoperative MRI in patients with invasive breast cancer. Materials and Methods: We retrospectively reviewed the preoperative breast MRI of 192 consecutive patients with surgically proven invasive breast cancer. We analyzed MRI findings of axillary lymph nodes with regard to the size, long/short ratio, cortical thickness, shape and margin of the cortex, loss of hilum, asymmetry, signal intensity (SI) on T2-weighted images (T2WI), degree of enhancement in the early phase, and enhancement kinetics. Receiver operating characteristic (ROC) analysis, chi-square test, t test, and McNemar's test were used for statistical analysis. Results: Increased shorter diameter, uneven cortical shape, increased cortical thickness, loss of hilum, asymmetry, irregular cortical margin, and low SI on T2WI were significantly suggestive of metastasis. ROC analysis revealed the cutoff value for the shorter diameter and cortical thickness as 8.05 mm and 2.75 mm, respectively. Increased cortical thickness (> 2.75 mm) and uneven cortical shape showed significantly higher sensitivity than other findings in McNemar's test. Irregular cortical margins showed the highest specificity (100%). Conclusion: Cortical thickness > 2.75 mm and uneven cortical shape are more sensitive parameters than other findings, and an irregular cortical margin is the most specific parameter for predicting axillary metastasis in patients with invasive breast cancer.

20.
Medicine (Baltimore) ; 101(41): e31095, 2022 Oct 14.
Article in English | MEDLINE | ID: mdl-36253983

ABSTRACT

While the extrinsic factors affecting reproducibility of shear wave elastography (SWE) have been well documented, there are few resources assessing intrinsic characteristics of the lesion affecting the reproducibility and accuracy of SWE. In this regard, this study aimed to evaluate the accuracy of measured elasticity and the reproducibility of SWE according to the lesion size and stiffness. Two breast radiologists examined 20 targets of 4 different levels of stiffness and 5 different sizes (2.5, 4, 7, 11, and 18 mm) in a customized elasticity phantom. The B-mode image, color elastography image, and kPa measurement were obtained twice by each examiner with a 1-week interval. Inter- and intra-observer reproducibility and the accuracy of measured kPa were analyzed using intraclass correlation coefficient (ICC) and Bland-Altman analysis. Subgroup analysis was run to evaluate the effect of lesion size and stiffness on the reproducibility and accuracy of measured kPa. Inter- and intraobserver reproducibility for measuring kPa showed excellent agreement (ICC: 0.9742 and 0.9582; ICC: 0.9932 and 0.9294). The size and stiffness of the targets did not affect reproducibility. The overall accuracy of measured kPa was very high (ICC: 0.8049). In the subgroup analysis, targets that were ≤4 mm in size showed lower accuracy (ICC: 0.542), whereas targets that were 7 and 11 mm in size showed higher accuracy (ICC: 0.9832 and 0.9656, respectively). SWE shows excellent reproducibility regardless of lesion size or stiffness in phantom targets. The accuracy of measured kPa is high in lesions that are 7 and 11 mm in size but is low in lesions that are ≤4 mm in size.


Subject(s)
Elasticity Imaging Techniques , Data Collection , Elasticity , Elasticity Imaging Techniques/methods , Humans , Phantoms, Imaging , Reproducibility of Results
SELECTION OF CITATIONS
SEARCH DETAIL
...