Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 35
Filter
1.
Eur Urol Focus ; 2024 May 23.
Article in English | MEDLINE | ID: mdl-38789313

ABSTRACT

BACKGROUND AND OBJECTIVE: The aim of this study was to evaluate the stone-free status (SFS) rate and complications after flexible ureteroscopy (fURS) for treatment of renal stones using a flexible and navigable suction (FANS) ureteral access sheath. METHODS: Data for adults undergoing fURS in 25 centers worldwide were prospectively collected (August 2023 to January 2024). Exclusion criteria were abnormal renal anatomy and ureteral stones. All patients had computed tomography scans before and within 30 d after fURS with a FANS ureteral access sheath. SFS was defined as follows: grade A, zero fragments; grade B, a single fragment ≤2 mm; grade C, a single fragment 2.1-4 mm; and grade D, single/multiple fragments >4 mm. Data for continuous variables are presented as the median and interquartile range (IQR). Multivariable logistic regression was performed to evaluate predictors of grade A SFS. KEY FINDINGS AND LIMITATIONS: The study enrolled 394 patients (59.1% male) with a median age of 49 yr (IQR 36-61). The median stone volume was 1260 mm3 (IQR 706-1800). Thulium fiber laser (TFL) was used in 45.9% of cases and holmium laser in the rest. The median lasing time was 18 min (IQR 11-28) and the median operative time was 49 min (IQR 37-70). One patient required a blood transfusion and 3.3% of patients had low-grade fever. No patient developed sepsis. Low-grade ureteral injury occurred in eight patients (2%). The grade A SFS rate was 57.4% and the grade A + B SFS rate was 97.2%, while 2.8% of patients had grade C or D SFS. Eleven patients underwent repeat fURS. Multivariable analysis revealed that a stone volume of 1501-3000 mm3 (odds ratio 0.50) and of >3000 mm3 (odds ratio 0.29) were significantly associated with lower probability of grade A SFS, while TFL use was associated with higher SFS probability (odds ratio 1.83). Limitations include the lack of a comparative group. CONCLUSIONS AND CLINICAL IMPLICATIONS: fURS using a FANS ureteral access sheath resulted in a high SFS rate with negligible serious adverse event and reintervention rates. PATIENT SUMMARY: We looked at 30-day results for patients undergoing telescopic laser treatment for kidney stones using a special type of vacuum-assisted sheath to remove stone fragments. We found a high stone-free rate with minimal complications.

2.
BJU Int ; 133 Suppl 3: 25-32, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37943964

ABSTRACT

OBJECTIVES: To compare the diagnostic performance and radiological staging impact of 68 Ga-prostate-specific membrane antigen positron emission tomography/computed tomography (PSMA PET/CT) compared to 99 Tc whole-body bone scan (WBBS) for the detection of skeletal metastasis in the primary staging of prostate cancer (PCa). PATIENTS AND METHODS: A prospective institutional database was retrospectively examined for patients who underwent both PSMA PET and WBBS within a 1 week interval for PCa primary staging. Lesions were categorised as 'negative', 'equivocal', or 'definite' based on nuclear medicine physician interpretation. Metastatic burden was characterised for each imaging modality according to three groups: (i) local disease (no skeletal metastases), (ii) oligometastatic disease (three or fewer skeletal metastases), or (iii) polymetastatic disease (more than three skeletal metastases). RESULTS: There were 667 patients included. The median (interquartile range) prostate-specific antigen level was 9.2 (6.2-16) ng/mL and 60% of patients were high risk according to a modified D'Amico risk classification. The overall distribution of skeletal metastasis detection changed across the two scans overall (P = 0.003), being maintained within high-risk (P = 0.030) and low-risk (P = 0.018) groups. PSMA PET/CT identified more definite skeletal metastases compared to WBBS overall (10.3% vs 7.3%), and according to risk grouping (high: 12% vs 9%, intermediate: 4% vs 1%). Upstaging was more common with PSMA PET/CT than WBBS (P = 0.001). The maximum standardised uptake value (SUVmax ) of the primary tumour was associated with upstaging of skeletal metastases on PSMA PET/CT (P = 0.025), while age was associated with upstaging on WBBS (P = 0.021). The SUVmax of the primary tumour and metastases were both higher according to extent of metastatic disease (P = 0.001 and P < 0.001, respectively). CONCLUSIONS: More skeletal metastases were detected with PSMA PET/CT than WBBS, resulting in a higher upstaging rate mostly in high-risk patients. The SUVmax of the primary tumour and metastases was associated with upstaging.


Subject(s)
Prostate , Prostatic Neoplasms , Male , Humans , Prostate/pathology , Positron Emission Tomography Computed Tomography/methods , Retrospective Studies , Prospective Studies , Gallium Radioisotopes , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/pathology
3.
Sci Adv ; 8(8): eabk0231, 2022 Feb 25.
Article in English | MEDLINE | ID: mdl-35213216

ABSTRACT

The acquisition and execution of motor skills are mediated by a distributed motor network, spanning cortical and subcortical brain areas. The sensorimotor striatum is an important cog in this network, yet the roles of its two main inputs, from motor cortex and thalamus, remain largely unknown. To address this, we silenced the inputs in rats trained on a task that results in highly stereotyped and idiosyncratic movement patterns. While striatal-projecting motor cortex neurons were critical for learning these skills, silencing this pathway after learning had no effect on performance. In contrast, silencing striatal-projecting thalamus neurons disrupted the execution of the learned skills, causing rats to revert to species-typical pressing behaviors and preventing them from relearning the task. These results show distinct roles for motor cortex and thalamus in the learning and execution of motor skills and suggest that their interaction in the striatum underlies experience-dependent changes in subcortical motor circuits.

4.
Nat Neurosci ; 24(9): 1256-1269, 2021 09.
Article in English | MEDLINE | ID: mdl-34267392

ABSTRACT

The basal ganglia are known to influence action selection and modulation of movement vigor, but whether and how they contribute to specifying the kinematics of learned motor skills is not understood. Here, we probe this question by recording and manipulating basal ganglia activity in rats trained to generate complex task-specific movement patterns with rich kinematic structure. We find that the sensorimotor arm of the basal ganglia circuit is crucial for generating the detailed movement patterns underlying the acquired motor skills. Furthermore, the neural representations in the striatum, and the control function they subserve, do not depend on inputs from the motor cortex. Taken together, these results extend our understanding of the basal ganglia by showing that they can specify and control the fine-grained details of learned motor skills through their interactions with lower-level motor circuits.


Subject(s)
Basal Ganglia/physiology , Motor Skills/physiology , Animals , Biomechanical Phenomena/physiology , Female , Learning/physiology , Rats , Rats, Long-Evans
5.
Asian J Urol ; 8(2): 170-175, 2021 Apr.
Article in English | MEDLINE | ID: mdl-33996472

ABSTRACT

OBJECTIVE: To evaluate the use of Gallium-68 prostate-specific membrane antigen positron emission tomography/computed tomography (68Ga-PSMA PET/CT), compared with conventional CT abdomen/pelvis (CTAP) and whole body single photon emission CT bone scan (BS), for detection of local or distant metastasis following biochemical failure/recurrence in post-prostatectomy patients. METHODS: We conducted a review of our prospectively maintained, institutional database to identify 384 patients with post-prostatectomy biochemical failure/recurrence who underwent PSMA PET/CT, CTAP and BS from February 2015 to August 2017 in Nepean Hospital, tertiary referral centre. The results of the three imaging modalities were analysed for their ability to detect local recurrence and distant metastases. PSMA PET/CT and CTAP imaging were separately performed on the same day and the BS was performed within several days (mostly in 24 h). Difference in detection rates was determined between the modalities and the Chi square test was used to determine significance. RESULTS: A total of 384 patients were identified with a median prostate-specific antigen (PSA) of 0.465 ng/mL (interquartile range =0.19-2.00 ng/mL). Overall, PSMA PET/CT was positive for 245 (63.8%) patients whereas CTAP and BS were positive in 174 patients (45.3%). A total of 98 patients (25.5%) had local or distant metastasis detected on PSMA only, while 20 patients (5.2%) had recurrences detected on CTAP but not on PSMA PET/CT. CONCLUSION: The use of PSMA PET/CT has a higher detection rate of predicted local or distant metastasis compared to CTAP and BS in the staging of patients with biochemical recurrences after radical prostatectomy.

6.
World J Urol ; 39(6): 1781-1788, 2021 Jun.
Article in English | MEDLINE | ID: mdl-32797262

ABSTRACT

PURPOSE: To compare the efficacy and time-to-discharge of two methods of trial of void (TOV): bladder infusion versus standard catheter removal. METHODS: Electronic searches for randomized controlled trials (RCTs) comparing bladder infusion versus standard catheter removal were performed using multiple electronic databases from dates of inception to June 2020. Participants underwent TOV after acute urinary retention or postoperatively after intraoperative indwelling catheter (IDC) placement. Quality assessment and meta-analyses were performed, with odds ratio and mean time difference used as the outcome measures. RESULTS: Eight studies, comprising 977 patients, were included in the final analysis. Pooled meta-analysis demonstrated that successful TOV was significantly higher in the bladder infusion group compared to standard TOV (OR 2.41, 95% CI 1.53-3.8, p = 0.0005), without significant heterogeneity (I2=19%). The bladder infusion group had a significantly shorter time-to-decision in comparison to standard TOV (weighted mean difference (WMD)-148.96 min, 95% CI - 242.29, - 55.63, p = 0.002) and shorter time-to-discharge (WMD - 89.68 min, 95% CI - 160.55, - 18.88, p = 0.01). There was no significant difference in complication rates between the two groups. CONCLUSION: The bladder infusion technique of TOV may be associated with a significantly increased likelihood of successful TOV and reduced time to discharge compared to standard TOV practices.


Subject(s)
Catheters, Indwelling , Device Removal , Urinary Catheters , Urinary Retention/therapy , Urination , Humans , Urinary Bladder
8.
Surg Technol Int ; 37: 168-170, 2020 Nov 28.
Article in English | MEDLINE | ID: mdl-32520387

ABSTRACT

The aim of this novel in vivo study was to characterize the effect of short pulse-width versus long pulse-width Holmium-YAG laser lithotripter settings on retropulsion and fragmentation in a real-life setting. A prospective, crossover study was conducted at a tertiary teaching hospital in NSW, Australia. Patients who underwent flexible ureteroscopy with laser lithotripsy for renal calculi in 2018 were included. All patients underwent flexible ureteroscopy using a Flexor® 10.7/12 French ureteric access sheath (Cook Medical LLC, Bloomington, IN, USA) and lithotripsy with a 30W Holmium-YAG laser (Rocamed, Monaco). Thirty-two renal calculi were subjected to 1 min of laser treatment using both short and long pulse-width settings. Using 5-point, operator-assessed Likert scales, the level of retropulsion and fragmentation efficacy were assessed. There was significantly less retropulsion and improved stone fragmentation (p<0.001) using the long pulse-width compared to the short pulse-width setting. Regardless of stone size, in vivo renal calculi lithotripsy with a long pulse-width significantly improves the efficacy of lithotripter treatment.


Subject(s)
Kidney Calculi , Lasers, Solid-State , Lithotripsy , Cross-Over Studies , Holmium , Humans , Kidney Calculi/surgery , Lasers, Solid-State/therapeutic use , Prospective Studies
9.
BJU Int ; 126 Suppl 1: 27-32, 2020 09.
Article in English | MEDLINE | ID: mdl-32573114

ABSTRACT

OBJECTIVE: To determine the diagnostic accuracy of ultra-low-dose computed tomography (ULDCT) compared with standard-dose CT (SDCT) in the evaluation of patients with clinically suspected renal colic, in addition to secondary features (hydroureteronephrosis, perinephric stranding) and additional pathological entities (renal masses). PATIENTS AND METHODS: A prospective, comparative cohort study was conducted amongst patients presenting to the emergency department with signs and symptoms suggestive of renal or ureteric colic. Patients underwent both SDCT and ULDCT. Single-blinded review of the image sets was performed independently by three board-certified radiologists. RESULTS: Among 21 patients, the effective radiation dose was lower for ULDCT [mean (SD) 1.02 (0.16) mSv] than SDCT [mean (SD) 4.97 (2.02) mSv]. Renal and/or ureteric calculi were detected in 57.1% (12/21) of patients. There were no significant differences in calculus detection and size estimation between ULDCT and SDCT. A higher concordance was observed for ureteric calculi (75%) than renal calculi (38%), mostly due to greater detection of calculi of <3 mm by SDCT. Clinically significant calculi (≥3 mm) were detected by ULDCT with high specificity (97.6%) and sensitivity (100%) compared to overall detection (specificity 91.2%, sensitivity 58.8%). ULDCT and SDCT were highly concordant for detection of secondary features, while ULDCT detected less renal cysts of <2 cm. Inter-observer agreement for the ureteric calculi detection was 93.9% for SDCT and 87.8% for ULDCT. CONCLUSION: ULDCT performed similarly to SDCT for calculus detection and size estimation with reduced radiation exposure. Based on this and other studies, ULDCT should be considered as the first-line modality for evaluation of renal colic in routine practice.


Subject(s)
Radiation Dosage , Renal Colic/diagnostic imaging , Tomography, X-Ray Computed/methods , Adult , Aged , Cysts/diagnostic imaging , Cysts/pathology , Female , Humans , Kidney Calculi/diagnostic imaging , Kidney Calculi/pathology , Kidney Diseases/diagnostic imaging , Kidney Diseases/pathology , Male , Middle Aged , Prospective Studies , Renal Colic/etiology , Single-Blind Method , Ureteral Calculi/diagnostic imaging , Ureteral Calculi/pathology
10.
J Endourol ; 34(4): 401-408, 2020 04.
Article in English | MEDLINE | ID: mdl-32037859

ABSTRACT

Purpose: To perform a systematic review and meta-analysis and to assess the clinical benefit of prophylactic pelvic drain (PD) placement after robot-assisted laparoscopic prostatectomy (RALP) with pelvic lymph node dissection (PLND) in patients with localized prostate cancer. Materials and Methods: An electronic search of databases, including Scopus, Medline, and EMbase, was conducted for articles that considered postoperative outcomes with PD placement and without PD (no drain) placement after RALP. The primary outcome was rate of symptomatic lymphocele (requiring intervention) and secondary outcomes were complications as described by the Clavien-Dindo classification system. Quality assessment was performed using the Modified Cochrane Risk of Bias Tool for Quality Assessment. Results: Six relevant articles comprising 1783 patients (PD = 1253; ND = 530) were included. Use of PD conferred no difference in symptomatic lymphocoele rate (risk difference 0.01; 95% confidence interval [CI] -0.007 to 0.027), with an overall incidence of 2.2% (95% CI 0.013-0.032). No difference in low-grade (I-II; risk difference 0.035, 95% CI -0.065 to 0.148) or high-grade (III-V; risk difference -0.003, 95% CI -0.05 to 0.044) complications was observed between PD and ND groups. Low-grade (I-II) complications were 11.8% (95% CI 0-0.42) and 7.3% (95% CI 0-0.26), with similar rates of high-grade (III-V) complications, being 4.1% (95% CI 0.008-0.084) and 4.3% (95% CI 0.007-0.067) for PD and ND groups, respectively. Conclusion: PD insertion after RALP with extended PLND did not confer significant benefits in prevention of symptomatic lymphocoele or postoperative complications. Based on these results, PD insertion may be safely omitted in uncomplicated cases after consideration of clinical factors.


Subject(s)
Prostatic Neoplasms , Robotic Surgical Procedures , Robotics , Humans , Lymph Node Excision , Male , Pelvis/surgery , Prostatectomy , Prostatic Neoplasms/surgery , Robotic Surgical Procedures/adverse effects
11.
Int J Urol ; 26(10): 999-1005, 2019 10.
Article in English | MEDLINE | ID: mdl-31448473

ABSTRACT

OBJECTIVES: To compare the performance and surgical outcomes of two different single-use digital flexible ureteroscopes with a reusable video flexible ureteroscope. METHODS: Patients undergoing retrograde flexible ureteroscopy at Nepean Hospital, Sydney, Australia, were included in this study. Three different flexible ureteroscopes were used in this study: (i) single-use digital LithoVue (Boston Scientific, Marlborough, MA, USA); (ii) single-use digital PU3022A (Pusen, Zhuhai, China); and (iii) reusable digital URF-V2 (Olympus, Tokyo, Japan). Visibility and maneuverability was rated on a 5-point Likert scale by the operating surgeon. Operative outcomes and complications were collected and analyzed. RESULTS: A total of 150 patients were included in the present study. Of these, 141 patients had ureteroscopy for stone treatment, four for endoscopic combined intrarenal surgery and five for diagnostic/tumor treatment. There were 55 patients in the LithoVue group, 31 in the PU3022A group and 64 patients in the Olympus URF-V2 group. The URF-V2 group had higher visibility scores than both the single-use scopes and higher maneuverability scores when compared with the PU3022A. The LithoVue had higher visibility and maneuverability scores when compared with the PU3022A. There were no differences in operative time, rates of relook flexible ureteroscopes, scope failure or complication rates observed. CONCLUSIONS: Single-use digital flexible ureteroscopes have visibility and maneuverability profiles approaching that of a reusable digital flexible ureteroscope. Single-use flexible ureteroscopes achieve similar clinical outcomes to the more expensive reusable versions.


Subject(s)
Equipment Reuse/standards , Kidney Calculi/surgery , Ureteroscopes/standards , Ureteroscopy/standards , Australia , Cross-Sectional Studies , Equipment Design , Equipment Reuse/economics , Female , Humans , Male , Middle Aged , Operative Time , Prospective Studies , Ureteroscopes/economics , Ureteroscopy/economics
12.
J Urol ; 202(1): 170, 2019 07.
Article in English | MEDLINE | ID: mdl-31012793
13.
Radiat Prot Dosimetry ; 182(1): 107-111, 2018 Dec 01.
Article in English | MEDLINE | ID: mdl-30165556

ABSTRACT

3,4,3-LI(1,2-HOPO) has been identified as an excellent alternative for DTPA for decorporating actinides, such as Pu and Am, after internal contamination. Efforts have been focused on its application through oral administration. When 3,4,3-LI(1,2-HOPO) was encapsulated with biocompatible, biodegradable nanoparticles made of chitosan, its release from the nanoparticles to lung fluid, observed in in vitro experiments, exhibited an extended release profile. These observations were very encouraging, as this nanomedicine could lead to a reduction in the dosing frequency required to achieve the decorporation efficacy of unformulated 3,4,3-LI(1,2-HOPO) itself. In vivo release tests as well as actinide decorporation experiments, using an inhalation exposure animal model, will follow.


Subject(s)
Chitosan/chemistry , Decontamination/methods , Heterocyclic Compounds, 1-Ring/administration & dosage , Lung/metabolism , Nanoparticles/administration & dosage , Pentetic Acid/administration & dosage , Pyridones/administration & dosage , Actinoid Series Elements/adverse effects , Administration, Inhalation , Americium/adverse effects , Body Fluids/metabolism , Chelating Agents/administration & dosage , Humans , Nanoparticles/chemistry , Plutonium/adverse effects , Radiation Dosage
14.
Urology ; 118: e1-e2, 2018 Aug.
Article in English | MEDLINE | ID: mdl-29800633

ABSTRACT

The present paper described a rare case of ureteral IgG4-related disease (IgG4-RD) that mimicked urothelial carcinoma. An otherwise healthy patient presented with computed tomography, ureteroscopic, and biopsy findings that were suspicious of urothelial carcinoma. The patient received a right nephroureterectomy. Histopathology showed ureteral IgG4-RD, without evidence of urothelial carcinoma. Accurate diagnosis of this rare entity should be based on clinical, biochemical, and histopathological findings.


Subject(s)
Carcinoma, Transitional Cell/diagnosis , Immunoglobulin G4-Related Disease , Nephroureterectomy/methods , Ureteral Diseases , Ureteral Neoplasms/diagnosis , Urothelium/pathology , Biopsy/methods , Carcinoma, Transitional Cell/pathology , Diagnosis, Differential , Humans , Immunoglobulin G4-Related Disease/diagnosis , Immunoglobulin G4-Related Disease/physiopathology , Immunoglobulin G4-Related Disease/surgery , Kidney Function Tests/methods , Male , Middle Aged , Ureter/pathology , Ureter/surgery , Ureteral Diseases/diagnosis , Ureteral Diseases/physiopathology , Ureteral Diseases/surgery , Ureteral Neoplasms/pathology
15.
Radiat Prot Dosimetry ; 174(4): 449-456, 2017 May 01.
Article in English | MEDLINE | ID: mdl-27574317

ABSTRACT

The Global Health Security Initiative (GHSI) established a laboratory network within the GHSI community to develop collective surge capacity for radionuclide bioassay in response to a radiological or nuclear emergency as a means of enhancing response capability, health outcomes and community resilience. GHSI partners conducted an exercise in collaboration with the WHO Radiation Emergency Medical Preparedness and Assistance Network and the IAEA Response and Assistance Network, to test the participating laboratories (18) for their capabilities in in vitro assay of biological samples, using a urine sample spiked with multiple high-risk radionuclides (90Sr, 106Ru, 137Cs, and 239Pu). Laboratories were required to submit their reports within 72 h following receipt of the sample, using a pre-formatted template, on the procedures, methods and techniques used to identify and quantify the radionuclides in the sample, as well as the bioassay results with a 95% confidence interval. All of the participating laboratories identified and measured all or some of the radionuclides in the sample. However, gaps were identified in both the procedures used to assay multiple radionuclides in one sample, as well as in the methods or techniques used to assay specific radionuclides in urine. Two-third of the participating laboratories had difficulties in determining all the radionuclides in the sample. Results from this exercise indicate that challenges remain with respect to ensuring that results are delivered in a timely, consistent and reliable manner to support medical interventions. Laboratories within the networks are encouraged to work together to develop and maintain collective capabilities and capacity for emergency bioassay, which is an important component of radiation emergency response.


Subject(s)
Biological Assay , Radioactive Hazard Release , Radioisotopes , Emergencies , Humans , Laboratories , Plutonium
16.
Radiat Environ Biophys ; 55(2): 161-9, 2016 May.
Article in English | MEDLINE | ID: mdl-26961776

ABSTRACT

This study was designed to assess the feasibility of a noninvasive urine specimen for the detection of proteins as indicators of internal exposure to ionizing radiation. Three groups of rats (five in each group) were intravenously injected with 1601 ± 376, 10,846 ± 591 and 48,467 ± 2812 Bq of (210)Po in citrate form. A sham-exposed control group of five rats was intravenously injected with sterile physiological saline. Daily urine samples were collected over 4 days following injection. Purification and pre-concentration of urinary proteins were carried out by ultrafiltration using a 3000 Da molecular weight cutoff membrane filter. The concentration of common urinary proteins, namely albumin, alpha-1-acid glycoprotein, immunoglobulins IgA and IgG, was measured by an enzyme-linked immunosorbent assay. Urinary excretion of albumin decreased dose-dependently (p < 0.05) 96 h post-injection relative to the control group. In contrast, no statistically significant effects were observed for other proteins tested. The dose-dependent decrease in urinary excretion of albumin observed in this study underscores the need for further research, which may lead to the discovery of new biomarkers that would reflect the changes in the primary target organs for deposition of (210)Po.


Subject(s)
Environmental Monitoring/methods , Polonium/adverse effects , Proteinuria/urine , Amidohydrolases/urine , Animals , Biomarkers/urine , Enzyme-Linked Immunosorbent Assay , Male , Rats , Rats, Wistar , Ultrafiltration
17.
Radiat Prot Dosimetry ; 171(3): 351-357, 2016 Nov.
Article in English | MEDLINE | ID: mdl-26405219

ABSTRACT

The Global Health Security Initiative (GHSI) established a laboratory network within the GHSI community to develop their collective surge capacity for radionuclide bioassay in response to a radiological or nuclear emergency. A recent exercise was conducted to test the participating laboratories for their capabilities in screening and in vitro assay of biological samples, performing internal dose assessment and providing advice on medical intervention, if necessary, using a urine sample spiked with a single radionuclide, 241Am. The laboratories were required to submit their reports according to the exercise schedule and using pre-formatted templates. Generally, the participating laboratories were found to be capable with respect to rapidly screening samples for radionuclide contamination, measuring the radionuclide in the samples, assessing the intake and radiation dose, and providing advice on medical intervention. However, gaps in bioassay measurement and dose assessment have been identified. The network may take steps to ensure that procedures and practices within this network be harmonised and a follow-up exercise be organised on a larger scale, with potential participation of laboratories from the networks coordinated by the International Atomic Energy Agency and the World Health Organization.


Subject(s)
Biological Assay/methods , Disaster Planning/methods , Emergency Medicine/methods , Radioisotopes/chemistry , Radiometry/methods , Emergencies , Humans , Laboratories , Public Health , Radioactive Hazard Release
18.
Neuron ; 86(3): 800-12, 2015 May 06.
Article in English | MEDLINE | ID: mdl-25892304

ABSTRACT

Motor cortex is widely believed to underlie the acquisition and execution of motor skills, but its contributions to these processes are not fully understood. One reason is that studies on motor skills often conflate motor cortex's established role in dexterous control with roles in learning and producing task-specific motor sequences. To dissociate these aspects, we developed a motor task for rats that trains spatiotemporally precise movement patterns without requirements for dexterity. Remarkably, motor cortex lesions had no discernible effect on the acquired skills, which were expressed in their distinct pre-lesion forms on the very first day of post-lesion training. Motor cortex lesions prior to training, however, rendered rats unable to acquire the stereotyped motor sequences required for the task. These results suggest a remarkable capacity of subcortical motor circuits to execute learned skills and a previously unappreciated role for motor cortex in "tutoring" these circuits during learning.


Subject(s)
Conditioning, Operant/physiology , Executive Function/physiology , Motor Cortex/physiology , Motor Skills/physiology , Movement/physiology , Animals , Biomechanical Phenomena , Female , Forelimb/physiology , Functional Laterality , Ibotenic Acid/toxicity , Male , Motor Cortex/injuries , Neural Pathways/physiology , Rats , Rats, Long-Evans , Reward , Statistics as Topic , Stereotyped Behavior/physiology
19.
Radiat Prot Dosimetry ; 167(4): 472-84, 2015 Dec.
Article in English | MEDLINE | ID: mdl-25543132

ABSTRACT

Nine laboratories participated in an intercomparison exercise organised by the European Radiation Dosimetry Group (EURADOS) for emergency radiobioassay involving four high-risk radionuclides ((239)Pu, (241)Am, (90)Sr and (226)Ra). Diverse methods of analysis were used by the participating laboratories for the in vitro determination of each of the four radionuclides in urine samples. Almost all the methods used are sensitive enough to meet the requirements for emergency radiobioassay derived for this project in reference to the Clinical Decision Guide introduced by the NCRP. Results from most of the methods meet the requirements of ISO 28218 on accuracy in terms of relative bias and relative precision. However, some technical gaps have been identified. For example, some laboratories do not have the ability to assay samples containing (226)Ra, and sample turnaround time would be expected to be much shorter than that reported by many laboratories, as timely results for internal contamination and early decisions on medical intervention are highly desired. Participating laboratories are expected to learn from each other on the methods used to improve the interoperability among these laboratories.


Subject(s)
Biological Assay/methods , Emergency Medicine/methods , Laboratories/standards , Radiation Monitoring/methods , Radioactive Pollutants/urine , Radiochemistry/methods , Urinalysis/methods , Humans , Radiometry , Reference Standards , Technology Assessment, Biomedical , Urine/chemistry
20.
Health Phys ; 101(2): 112-7, 2011 Aug.
Article in English | MEDLINE | ID: mdl-21709496

ABSTRACT

Population monitoring is an important component of radiological and nuclear emergency preparedness and response. Since 2002, Canada has been investing in developing national capabilities in radiological population monitoring. This paper summarizes Canada's efforts in developing methods and techniques in biological dosimetry and in vivo and in vitro bioassay techniques. There are still many gaps to fill that require further efforts. Integration of different monitoring methods and techniques in order to have the best assessment of radiation dose to support medical management and integration of Canada's efforts with international efforts are recommended.


Subject(s)
Radiation Monitoring/methods , Biological Assay , Canada , Civil Defense , Humans , Radiation Monitoring/instrumentation , Radiation Monitoring/standards , Radiation Protection/methods , Radiation Protection/standards , Radiometry , Risk Assessment/methods , Risk Assessment/standards
SELECTION OF CITATIONS
SEARCH DETAIL
...