Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Psychiatry Investig ; 20(1): 27-34, 2023 Jan.
Article in English | MEDLINE | ID: mdl-36721883

ABSTRACT

OBJECTIVE: Aerobic exercise may be associated with changes in brain activity within the default mode network (DMN) and dorsal attention network (DAN). We hypothesized that changes in functional connectivity (FC) within the DMN and DAN might be most effectively activated by moderate-intensity exercise. METHODS: Resting-state functional magnetic resonance imaging scans and visuospatial attention tests after resting were performed before and after each of moderate- and high-intensity aerobic exercises (10 min each) in 15 healthy male volunteers. RESULTS: The reaction time during the attention test increased significantly, and the rate of correct responses decreased from moderate-intensity exercise condition to high-intensity exercise condition. FC within the DMN under high-intensity exercise condition was higher than that under pre-exercise and moderate-intensity exercise conditions. FC within the DAN under moderate-intensity exercise condition was the highest, whereas FC between the DMN and DAN under moderate-intensity exercise condition was the lowest. Changes in cognitive domain functions were associated with changes in FC between the DMN and DAN. CONCLUSION: Our results support the inverted-U hypothesis of maximum arousal efficacy during moderate exercise. Both cognitive domains, namely, the attention system and brain activity domains, may be better under moderate-intensity exercise than under high-intensity exercise.

2.
Ultrasonics ; 91: 121-128, 2019 Jan.
Article in English | MEDLINE | ID: mdl-30096537

ABSTRACT

In this paper, the effect of ablation on the shape of elastic waves generated by laser excitation is studied numerically and experimentally. Laser-induced ultrasound has been widely used in the nondestructive testing (NDT) field because it has the advantage that the sensor does not have to be directly attached to the target structure. In the safety assessment process, low energy excitation is used, and thus the structure is not damaged. Most studies related to laser ultrasound have focused on the method of detecting cracks within the elastic range, and there have been few studies on the effect of ablation. This research consists of experiments and numerical analyses. In experiments, elastic waves were generated in an aluminum plate by projecting laser pulses with different energy intensities. The velocities in the thickness direction were measured using a Laser Doppler Velocimeter (LDV) at a point 135 mm away from the excitation point. In the numerical study, two numerical simulations were carried out using heat flux and normal stress input to mimic laser pulse excitation. A thermo-mechanical simulation by heat flux was conducted to simulate thermal expansion by the laser pulse, and the normal stress was applied to reflect the effect of radiation pressure by ablation, respectively. Waveforms were synthesized by using different magnitude ratios of the obtained numerical responses and were compared with the experiment results. It is found that the effect of radiation pressure should not be neglected if the energy intensity is large although the effect of radiation pressure decreases as the energy intensity decreases. At the energy intensity with which ablation occurs, the effects of thermal expansion and radiation pressure exist simultaneously, and the contribution to the response depends on the energy intensity.

SELECTION OF CITATIONS
SEARCH DETAIL
...