Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters










Database
Language
Publication year range
1.
J Pharm Biomed Anal ; 248: 116293, 2024 Jun 06.
Article in English | MEDLINE | ID: mdl-38901154

ABSTRACT

A method of analysis was developed for the simultaneous chemo- and enantioseparation of 2-, 3-, and 4-chloromethcathinones by high-performance liquid chromatography tandem mass-spectrometry. The fast method enables the reliable identification of positional isomers of chloromethcathinones in biological samples. In addition, the same method can be used for the enantioselective quantitative determination of one of these compounds and its major phase-1 metabolites in biological fluids. The developed method was applied to oral fluid samples collected by police during routine random traffic control in Belgium from January to November, 2023. It was found that 3-CMC was more frequently abused compared to 4-CMC. Although some differences were observed between the concentrations of enantiomers in OF, most likely the drugs were abused in the racemic form. No abuse of 2-CMC was detected at the timepoint of sample collection.

2.
J Chromatogr A ; 1730: 465062, 2024 Jun 08.
Article in English | MEDLINE | ID: mdl-38889581

ABSTRACT

Hydrogen/deuterium (H/D) isotope effects are not unusual in chromatography and such phenomena have been observed in both gas- and liquid-phase separations. Despite the numerous reports on this topic, the understanding of mechanisms and the underlying noncovalent interactions at play remains rather challenging. In our recent study, we reported baseline separation of isotopologoues of some amphetamine (AMP) derivatives on achiral and polysaccharide-based chiral columns, as well as some correlations between the degree of separation of enantiomers and isotopologues on (the same) polysaccharide-based chiral column(s). Following our previous findings on isotope effects in high-performance liquid chromatography, we report herein a comparative study on the isotope effects observed with AMP and methamphetamine (MET). The impact of some pivotal factors such as the number of deuterium atoms part of AMP isotopologues, the structure of its isotopomers, the chemical structure of the achiral and chiral stationary phases used in this study, and the use of methanol- vs acetonitrile-containing mobile phases on the isotope effects was examined and discussed. Quantitative correlations between the observed isotope effects and the enantioselectivity of the chiral columns used are also shortly discussed. Furthermore, considering the chromatographic results as benchmark experimental data, we attempted to elucidate the molecular bases of the observed phenomena using quantum mechanics calculations.

3.
J Pharm Biomed Anal ; 243: 116076, 2024 Jun 15.
Article in English | MEDLINE | ID: mdl-38430614

ABSTRACT

Recently we published in this journal an enantioselective high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the quantitative determination of 3,4-methylenedioxymethamphetamine (MDMA) and its major phase-1 metabolites, 4-hydroxy-3-methoxyamphetamine (HMA), 4-hydroxy-3-methoxymethamphetamine (HMMA) and 3,4-methylenedioxyamphetamine (MDA) in human plasma, sweat, oral fluid and urine. Since we did not achieve simultaneous enantioseparation of all 4 compounds with a single chiral column, two amylose-based chiral columns were used alternatively. Further optimization of the mobile phase in the present study enabled baseline separation of all four pairs of enantiomers on a single Lux AMP column. In addition, by optimization of the column dimension and applied flow-rate it became possible to complete the separation within 6 minutes. These new methods were applied to the analysis of human plasma, oral fluid and urine. While results on the concentration of MDMA and its metabolites in various biological fluids were reported in our recent publication, in the present study an attempt was made to hydrolyze glucuronides in urine samples by using alternatively, hydrochloric acid or glucuronidase and to evaluate the effect of hydrolysis on the concentration and enantiomeric distribution of hydroxy metabolites of MDMA such as HMA and HMMA.


Subject(s)
3,4-Methylenedioxyamphetamine , Lactates , Methamphetamine , N-Methyl-3,4-methylenedioxyamphetamine , Humans , N-Methyl-3,4-methylenedioxyamphetamine/urine , Chromatography, High Pressure Liquid , Tandem Mass Spectrometry , Chromatography, Liquid , Stereoisomerism , 3,4-Methylenedioxyamphetamine/urine
4.
Pharmaceuticals (Basel) ; 17(2)2024 Feb 15.
Article in English | MEDLINE | ID: mdl-38399464

ABSTRACT

In 2023, hexahydrocannabinol (HHC) attracted the attention of international agencies due to its rapid spread in the illegal market. Although it was discovered in 1940, less is known about the pharmacology of its two naturally occurring epimers, 9(R)-HHC and 9(S)-HHC. Thus, we aimed to investigate the disposition of hexahydrocannabinol epimers and their metabolites in whole blood, urine and oral fluid following a single controlled administration of a 50:50 mixture of 9(R)-HHC and 9(S)-HHC smoked with tobacco. To this end, six non-user volunteers smoked 25 mg of the HHC mixture in 500 mg of tobacco. Blood and oral fluid were sampled at different time points up to 3 h after the intake, while urine was collected between 0 and 2 h and between 2 and 6 h. The samples were analyzed with a validated HPLC-MS/MS method to quantify 9(R)-HHC, 9(S)-HHC and eight metabolites. 9(R)-HHC showed the highest Cmax and AUC0-3h in all the investigated matrices, with an average concentration 3-fold higher than that of 9(S)-HHC. In oral fluid, no metabolites were detected, while they were observed as glucuronides in urine and blood, but with different profiles. Indeed, 11nor-9(R)-HHC was the most abundant metabolite in blood, while 8(R)OH-9(R) HHC was the most prevalent in urine. Interestingly, 11nor 9(S) COOH HHC was detected only in blood, whereas 8(S)OH-9(S) HHC was detected only in urine.

5.
J Chromatogr A ; 1718: 464709, 2024 Mar 15.
Article in English | MEDLINE | ID: mdl-38350352

ABSTRACT

The different behavior of enantiomers of chiral compounds in non-isotropic environments (among them in living organism) is well known. On the other hand, the importance of a kinetic isotope effect in the biomedical field has become evident during past few decades. Thus, separation of both, enantiomers and isotopologues is now critical. Only very few published studies have attempted the simultaneous separation of enantioisotopologues. In this article we report baseline separation of partially deuterated isotopologues of a few amphetamine derivatives in high-performance liquid chromatography (HPLC) using achiral columns. In addition, the simultaneous separations of enantiomers and isotopologues (i.e. enantioisotopologues) were attempted on polysaccharide-based chiral columns. For several compounds the isotope effect was tunable and could be switched from a "normal" to "inverse" by making changes to the mobile-phase composition. A stronger isotope effect was observed in acetonitrile-containing mobile phases compared to methanol-containing ones with both chiral and achiral columns. In a separation system where both "normal" and "inverse" isotope effects were observed the "normal" isotope effect was favored in polar organic solvents while increasing content of the aqueous component in the reversed-phase (RP) mobile phase favored an "inverse" isotope effect. This observation indicates that polar, hydrogen bonding-type noncovalent interactions are involved in the "normal" isotope effect, while apolar hydrophobic-type interactions are mostly responsible for the "inverse" isotope effect.


Subject(s)
Amphetamine , Polysaccharides , Chromatography, High Pressure Liquid/methods , Polysaccharides/chemistry , Solvents/chemistry , Isotopes , Stereoisomerism
6.
J Pharm Biomed Anal ; 240: 115918, 2024 Mar 15.
Article in English | MEDLINE | ID: mdl-38181553

ABSTRACT

A sensitive LC-MS/MS method for the simultaneous quantification of the (9 R)- and (9 S)- hexahydrocannabinols (HHCs), and their metabolites, in human urine, oral fluid (OF) and blood samples were developed, validated and used to the biological samples of volunteers. The analytes were extracted from 100 µL human samples. An isocratic elution mode with methanol was used for chromatographic separation of (9 R)- and (9 S)-HHC on an immobilized amylose tris(3-chloro-5-methylphenylcarbamate)-based chiral column Lux i-Amylose-3. The flow-rate of the mobile phase was 0.5 mL/min. An isocratic elution mode of methanol and water (80/20, v/v) was used for chromatographic separation of metabolites of (9 R)- and (9 S)-HHC on a Lux AMP chiral column (with a proprietary chiral selector) at a flow rate of 0.5 mL/min. MS/MS analysis was performed in positive ionization mode for HHC epimers, while in negative ionization mode was used for metabolites of HHCs. The calibration curves for HHCs and their metabolites in human samples ranged from 0.25- 240 ng mL-1 and 1 - 100 ng mL-1, respectively, with determination coefficients (r2) of ≥ 0.99. All analytes were stable at room temperature, 4 °C, in the autosampler (+10 °C) and -20 °C for 24 h, after three freeze/thaw cycles, and when stored at -20 °C up to one week after quality control (QC) sample preparation (concentration differences less than 20% with respect to time zero response), in blood, urine and OF.


Subject(s)
Liquid Chromatography-Mass Spectrometry , Tandem Mass Spectrometry , Humans , Tandem Mass Spectrometry/methods , Chromatography, Liquid/methods , Methanol , Quality Control , Reproducibility of Results
7.
J Chromatogr A ; 1624: 461218, 2020 Aug 02.
Article in English | MEDLINE | ID: mdl-32540066

ABSTRACT

In this study, amylose- and cellulose-phenylcarbamate-based chiral columns with different chiral-selector (CS) chemistries were compared to each other for the separation of enantiomers of basic chiral analytes in acetonitrile and aqueous-acetonitrile mobile phases in HPLC. For two chemistries the amylose-based columns with coated and immobilized CSs were also compared. The comparison of CSs containing only electron-donating or electron-withdrawing substituents with those containing both electron-donating and electron-withdrawing substituents showed opposite results for the studied set of chiral analytes in the case of amylose and cellulose derivatives. Along with the chemistry of CS the focus was on the behavior of polysaccharide phenylcarbamates in acetonitrile versus aqueous acetonitrile as eluents. In agreement with earlier results, it was found that in contrast to the commonly accepted view, polysaccharide phenylcarbamates do not behave as typical reversed-phase materials for basic analytes either. In the range of water content in the mobile phase of up to 20-30% v/v the behavior of these CSs is similar to hydrophilic interaction liquid chromatography (HILIC)-type adsorbents. This means that with increasing water content in the mobile phase up to 20-30% v/v, the retention of analytes mostly decreases. The important finding of this study is that the separation efficiency improves for most analytes when switching from pure acetonitrile to aqueous acetonitrile. Therefore, in spite of reduced retention, the separation of enantiomers improves and thus, the HILIC-range of mobile phase composition, offering shorter analysis time and better peak resolution, is advantageous over pure polar-organic solvent mode. Interesting examples of enantiomer elution order (EEO) reversal were observed for some analytes based on the content of water in the mobile phase on Lux Cellulose-1 and Lux Amylose-2 columns.


Subject(s)
Amylose/chemistry , Cellulose/chemistry , Chromatography, High Pressure Liquid/methods , Pharmaceutical Preparations/isolation & purification , Phenylcarbamates/chemistry , Acetonitriles/chemistry , Electrons , Ethanolamines/analysis , Ethanolamines/isolation & purification , Pharmaceutical Preparations/analysis , Propanolamines/analysis , Propanolamines/isolation & purification , Propranolol/analysis , Propranolol/isolation & purification , Stereoisomerism , Water/chemistry
8.
J Chromatogr A ; 1599: 172-179, 2019 Aug 16.
Article in English | MEDLINE | ID: mdl-31005292

ABSTRACT

This article describes our attempt to re-visit the role of temperature in the separation of enantiomers with polysaccharide-based chiral columns in high-performance liquid chromatography (HPLC). Rarely observed increased retention and separation factors with increasing temperature, as well as temperature dependent reversal of enantiomer elution order are reported for several arylpropionic acid derivatives. Chiral columns with coated and covalently immobilized chiral selectors were compared from the viewpoint of effect of temperature on analyte retention, enantiomer separation and enantiomer elution order. Thermodynamic parameters were calculated for analyte transfer from the liquid phase to the chiral stationary phase and the effect of temperature on chiral selectors was investigated by using differential scanning calorimetry (DSC). DSC results along with chromatographic studies indicate that polysaccharide-based chiral selectors undergo some kind of transition at elevated temperature that is not reversible in the thermodynamic sense of this term.


Subject(s)
Chromatography, High Pressure Liquid , Polysaccharides/chemistry , Propionates/isolation & purification , Temperature , Propionates/analysis , Stereoisomerism
SELECTION OF CITATIONS
SEARCH DETAIL
...