Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Allergy ; 68(5): 580-4, 2013.
Article in English | MEDLINE | ID: mdl-23409759

ABSTRACT

Skin prick testing (SPT) in combination with the clinical history of the patient is one important step in the diagnosis of IgE-mediated occupational allergies. However, skin test performance is related to the quality of allergen extracts. The present consensus document was prepared by an EAACI Task Force consisting of an expert panel of allergologists and occupational physicians from Germany, Italy, Spain, France, Austria, and Poland. All members of the panel were also involved in the data collection within the European multicentre study STADOCA (Standard diagnosis for occupational allergy). The aim of this Task Force was the assessment of the quality of commercially available SPT solutions for selected occupational allergens under standardized procedure conditions in different European centres and institutes of Occupational Medicine. The data evaluation shows a wide variability among SPT solutions and also indicates that the sensitivity of several SPT solutions is low. Therefore, improvement and standardization of SPT solutions for occupational allergens is highly recommended. Clinical practitioners should also not presume that their SPT solutions are fully reliable. The main objective of the document is to issue consensus suggestions for the use of SPT with occupational allergens based on the European multicentre study STADOCA, on existing scientific evidence and the expertise of a panel of allergologists.


Subject(s)
Hypersensitivity, Immediate/diagnosis , Occupational Diseases/diagnosis , Skin Tests , Europe , Humans , Reproducibility of Results , Sensitivity and Specificity , Skin Tests/methods , Skin Tests/standards
2.
Allergy ; 68(5): 651-8, 2013.
Article in English | MEDLINE | ID: mdl-23421494

ABSTRACT

BACKGROUND: Skin prick testing (SPT) is an important step in the diagnosis of IgE-mediated occupational allergic diseases. The outcome of SPT is related to the quality of allergen extracts. Thus, the aim of the study was to assess different commercially available SPT solutions for selected occupational allergens. METHODS: SPT was performed in 116 bakers, 47 farmers and 33 subjects exposed to natural rubber latex (NRL), all with work-related allergic symptoms. The SPT solutions from different manufacturers (n = 3-5) for wheat flour, rye flour, soy, cow hair/dander, storage mites (Tyrophagus putrescentiae, Lepidoglyphus destructor, Acarus siro) and NRL were analysed with respect to their protein and antigen contents. SPT was carried out in 16 allergy centres in six European countries using standardized procedures. Specific IgE values were used as the gold standard to calculate the sensitivity and specificity of SPT solutions. The optimal cut-point for each SPT solution was determined by Youden Index. RESULTS: Protein and antigen contents and patterns of the SPT solutions varied remarkably depending on the manufacturer. While SPT solutions for wheat flour and soy reached overall low sensitivities, sensitivities of other tested SPT solutions depended on the manufacturer. As a rule, solutions with higher protein and antigen content showed higher sensitivities and test efficiencies. CONCLUSIONS: There is a wide variability of SPT solutions for occupational allergens, and the sensitivity of several solutions is low. Thus, improvement and standardization of SPT solutions for occupational allergens is essential.


Subject(s)
Hypersensitivity, Immediate/diagnosis , Occupational Diseases/diagnosis , Reagent Kits, Diagnostic , Skin Tests/methods , Adult , Animals , Europe , Female , Humans , Male , Middle Aged , ROC Curve , Reproducibility of Results , Skin Tests/standards
SELECTION OF CITATIONS
SEARCH DETAIL
...