Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 76
Filter
1.
Rev Sci Instrum ; 89(10): 10G108, 2018 Oct.
Article in English | MEDLINE | ID: mdl-30399872

ABSTRACT

In the quest for reaching ignition of deuterium-tritium (DT) fuel capsule implosions, experiments on the National Ignition Facility (NIF) have shown lower final fuel areal densities than simulated. Possible explanations for reduced compression are higher preheat that can increase the ablator-DT ice density jump and induce mix at that interface or reverberating shocks. We are hence developing x-ray Refraction Enhanced Radiography (RER) to infer the inflight density profiles in layered fuel capsule implosions. We use a 5 µm slit backlit by a Ni 7.8 keV He-α NIF laser driven x-ray source positioned at 20 mm from the capsule to cast refracted images of the inflight capsule onto a streak camera in a high magnification (M ∼ 60×) setup. Our first experiments have validated our setup that recorded a streaked x-ray fringe pattern from an undriven high density carbon (HDC) capsule consistent with ray tracing calculations at the required ∼6 µm and 25 ps resolution. Streaked RER was then applied to inflight layered HDC capsule implosions using a hydrogen-tritium fuel mix rather than DT to reduce neutron yields and associated backgrounds. The first RER of an imploding capsule revealed strong features associated with the ablation front and ice-ablator interface that are not visible in standard absorption radiographs.

2.
Rev Sci Instrum ; 87(11): 11E331, 2016 Nov.
Article in English | MEDLINE | ID: mdl-27910592

ABSTRACT

We have designed and fabricated a structured streak camera photocathode to provide enhanced efficiency for high energy X-rays (1-12 keV). This gold coated photocathode was tested in a streak camera and compared side by side against a conventional flat thin film photocathode. Results show that the measured electron yield enhancement at energies ranging from 1 to 10 keV scales well with predictions, and that the total enhancement can be more than 3×. The spatial resolution of the streak camera does not show degradation in the structured region. We predict that the temporal resolution of the detector will also not be affected as it is currently dominated by the slit width. This demonstration with Au motivates exploration of comparable enhancements with CsI and may revolutionize X-ray streak camera photocathode design.

3.
Rev Sci Instrum ; 87(11): 11E558, 2016 Nov.
Article in English | MEDLINE | ID: mdl-27910373

ABSTRACT

Spectroscopic techniques in the visible range are often used in plasma experiments to measure B-field induced Zeeman splitting, electron densities via Stark broadening, and temperatures from Doppler broadening. However, when electron densities and temperatures are sufficiently high, the broadening of the Stark and Doppler components can dominate the emission spectra and obscure the Zeeman component. In this research, we are developing a time-resolved multi-axial technique for measuring the Zeeman, Stark, and Doppler broadened line emission of dense magnetized plasmas for Z-pinch and Dense Plasma Focus (DPF) accelerators. The line emission is used to calculate the electron densities, temperatures, and B-fields. In parallel, we are developing a line-shape modeling code that incorporates the broadening effects due to Stark, Doppler, and Zeeman effects for dense magnetized plasma. This manuscript presents the details of the experimental setup and line shape code, along with the results obtained from an Al iii doublet at the University of Nevada, Reno at Nevada Terawatt Facility. Future tests are planned to further evaluate the technique and modeling on other material wire array, gas puff, and DPF platforms.

5.
Rev Sci Instrum ; 87(7): 073706, 2016 Jul.
Article in English | MEDLINE | ID: mdl-27475564

ABSTRACT

A multi-wavelength, high contrast contact radiography system has been developed to characterize density variations in ultra-low density aerogel foams. These foams are used to generate a ramped pressure drive in materials strength experiments at the National Ignition Facility and require precision characterization in order to reduce errors in measurements. The system was used to characterize density variations in carbon and silicon based aerogels to ∼10.3% accuracy with ∼30 µm spatial resolution. The system description, performance, and measurement results collected using a 17.8 mg/cc carbon based JX-6 (C20H30) aerogel are discussed in this manuscript.

6.
Rev Sci Instrum ; 87(6): 063103, 2016 Jun.
Article in English | MEDLINE | ID: mdl-27370422

ABSTRACT

A dual goniometer X-ray system was used to measure the reflectivity curve for a spherically bent quartz(211) crystal. An analysis of the dual goniometer instrument response function for the rocking curve width measurement was developed and tested against the actual measurements. The rocking curve was measured at 4510.8 eV using the Ti Kα1 characteristic spectral line. The crystal is the dispersion element for a high resolution spectrometer used for plasma studies. It was expected to have a very narrow rocking curve width. The analysis showed that we could measure the upper bound for the rocking curve width of the Qz(211) crystal. The upper bound was 58 µrad giving a lower bound for the instrument resolving power E/ΔE = 34 000. Greatly improved insight into the dual goniometer operation and its limitations was achieved.

7.
Langenbecks Arch Surg ; 400(3): 307-12, 2015 Apr.
Article in English | MEDLINE | ID: mdl-25702138

ABSTRACT

INTRODUCTION: Successful localization is mandatory for focused parathyroidectomy. If ultrasound and sestamibi scan are negative, bilateral neck exploration is necessary. We examined the contribution of complementary computed tomography (CT) scan to identify the affected parathyroid gland. METHODS: Between November 1999 and April 2014, 25 patients (20 females and 5 males; mean age 67 ± 11 years) with negative or dubious standard imaging (ultrasound and sestamibi scan) underwent CT scan prior to parathyroidectomy and were included in this study. Fifteen patients had had previous neck surgery for parathyroidectomy (n = 11) or thyroidectomy (n = 4). Thin-slice CT (n = 9) or four-dimensional (4D) CT imaging (n = 16) was used. Cure was defined as >50 % post-excision fall of intraoperatively measured parathyroid hormone or fall into the normal range, confirmed by normocalcaemia at least 6 months after surgery. RESULTS: Preoperative CT scan provided correct localization in 13 out of 25 patients (52 %) and was false positive once. Parathyroidectomy was performed by a focused approach in 11 of these 13 patients as well as in 1 patient guided by intraoperatively measured parathyroid hormone (ioPTH). Thirteen patients required bilateral neck exploration. The cure rate was 96 % (24/25 patients). One patient has persistent primary hyperparathyroidism (pHPT) and one a recurrent disease. Six patients presented a multiglandular disease. CONCLUSION: A CT scan identifies about half of abnormal parathyroid glands missed by conventional imaging and allows focused surgery in selected cases.


Subject(s)
Hyperparathyroidism, Primary/diagnostic imaging , Hyperparathyroidism, Primary/surgery , Parathyroidectomy/methods , Tomography, X-Ray Computed/methods , Aged , Aged, 80 and over , Contrast Media , Diagnosis, Differential , Female , Humans , Iopamidol/analogs & derivatives , Male , Reoperation/statistics & numerical data , Treatment Outcome
8.
Appl Opt ; 54(34): 10227-31, 2015 Dec 01.
Article in English | MEDLINE | ID: mdl-26836681

ABSTRACT

Near-normal-incidence bent crystals are widely used for x-ray imaging applications. Advantages include high collection solid angle and potentially high efficiency for narrow-band sources, while disadvantages include relatively large (several Å) interatomic spacings and a limited number of suitable matches between a crystal 2d value and an integral multiple of useful emission line wavelengths. The disadvantages become more significant at x-ray energies >10 keV. The former disadvantage can be mitigated by using high-order reflections from crystal planes having low Miller indices, but both disadvantages can be mitigated by using low-order reflections from crystal planes having high Miller indices. We report here on integrated reflectivity measurements we performed of Ge (15,7,7) (2d=0.6296 Å), a candidate for imaging Ru He-α (θ(B)=87°). We find good agreement with calculations, and the data show a multitude of closely spaced reflections with slightly different Bragg angles including a fifth-order reflection of Ge (3,1,1) that has comparable reflectivity. This demonstrates that arbitrary choices of Miller indices in Ge crystals can be used to fine-tune Bragg angles for near-normal-incidence x-ray imaging at tens of kiloelectron volt x-ray energies with minimal lower-energy contamination from lower-order reflections, and that existing calculational tools can be used to reliably estimate integrated reflectivity.

9.
Rev Sci Instrum ; 85(11): 11D625, 2014 Nov.
Article in English | MEDLINE | ID: mdl-25430201

ABSTRACT

A computer model in CST Studio Suite has been developed to evaluate several novel geometrically enhanced photocathode designs. This work was aimed at identifying a structure that would increase the total electron yield by a factor of two or greater in the 1-30 keV range. The modeling software was used to simulate the electric field and generate particle tracking for several potential structures. The final photocathode structure has been tailored to meet a set of detector performance requirements, namely, a spatial resolution of <40 µm and a temporal spread of 1-10 ps. We present the details of the geometrically enhanced photocathode model and resulting static field and electron emission characteristics.

10.
J Opt Soc Am A Opt Image Sci Vis ; 30(7): 1460-3, 2013 Jul 01.
Article in English | MEDLINE | ID: mdl-24323163

ABSTRACT

We present a simple solution to the Fresnel-Kirchoff diffraction integral that is appropriate for x-ray radiography of strongly absorbing and phase-shifting objects in the geometrical optics regime, where phase contrast enhancements can be considered to be caused by refraction by a semi-opaque object. We demonstrate its accuracy by comparison to brute-force numerical ray trace and diffraction calculations of a representative simulated object, and show excellent agreement for spatial scales corresponding to Fresnel numbers greater than unity. The result represents a significant improvement over approximate formulas typically used in analysis of refraction-enhanced radiographs, particularly for radiography of transient phenomena in objects that strongly refract and show significant absorption.

11.
Rev Sci Instrum ; 83(10): 10D310, 2012 Oct.
Article in English | MEDLINE | ID: mdl-23126837

ABSTRACT

A technique for comparing simulation results directly with radiograph data from backlit capsule implosion experiments will be discussed. Forward Abel transforms are applied to the kappa*rho profiles of the simulation. These provide the transmission ratio (optical depth) profiles of the simulation. Gaussian and top hat blurs are applied to the simulated transmission ratio profiles in order to account for the motion blurring and imaging slit resolution of the experimental measurement. Comparisons between the simulated transmission ratios and the radiograph data lineouts are iterated until a reasonable backlighter profile is obtained. This backlighter profile is combined with the blurred, simulated transmission ratios to obtain simulated intensity profiles that can be directly compared with the radiograph data. Examples will be shown from recent convergent ablation (backlit implosion) experiments at the NIF.

12.
Rev Sci Instrum ; 83(10): 10E127, 2012 Oct.
Article in English | MEDLINE | ID: mdl-23126948

ABSTRACT

Future implosion experiments at the national ignition facility (NIF) will endeavor to simultaneously measure electron and ion temperatures with temporal and spatial resolution in order to explore non-equilibrium temperature distributions and their relaxation toward equilibrium. In anticipation of these experiments, and with understanding of the constraints of the NIF facility environment, we have explored the use of Doppler broadening of mid-Z dopant emission lines, such as krypton He-α at 13 keV, as a diagnostic of time- and potentially space-resolved ion temperature. We have investigated a number of options analytically and with numerical raytracing, and we have identified several promising candidate spectrometer designs that meet the expected requirements of spectral and temporal resolution and data signal-to-noise ratio for gas-filled exploding pusher implosions, while providing maximum flexibility for use on a variety of experiments that potentially include burning plasma.

13.
Rev Sci Instrum ; 81(10): 10E317, 2010 Oct.
Article in English | MEDLINE | ID: mdl-21034015

ABSTRACT

A 5 ps gated framing camera was demonstrated using the pulse-dilation of a drifting electron signal. The pulse-dilation is achieved by accelerating a photoelectron derived information pulse with a time varying potential [R. D. Prosser, J. Phys. E 9, 57 (1976)]. The temporal dependence of the accelerating potential causes a birth time dependent axial velocity dispersion that spreads the pulse as it transits a drift region. The expanded pulse is then imaged with a conventional gated microchannel plate based framing camera and the effective gating time of the combined instrument is reduced over that of the framing camera alone. In the drift region, electron image defocusing in the transverse or image plane is prevented with a large axial magnetic field. Details of the unique issues associated with rf excited photocathodes were investigated numerically and a prototype instrument based on this principle was recently constructed. Temporal resolution of the instrument was measured with a frequency tripled femtosecond laser operating at 266 nm. The system demonstrated 20× temporal magnification and the results are presented here. X-ray image formation strategies and photometric calculations for inertial confinement fusion implosion experiments are also examined.

14.
Rev Sci Instrum ; 81(10): 10E515, 2010 Oct.
Article in English | MEDLINE | ID: mdl-21034043

ABSTRACT

A temporally gated x-ray framing camera based on a proximity focus microchannel plate is one of the most important diagnostic tools of inertial confinement fusion experiments. However, fusion neutrons produced in imploded capsules interact with structures surrounding the camera and produce background to x-ray signals. To understand the mechanisms of this neutron induced background, we tested several gated x-ray cameras in the presence of 14 MeV neutrons produced at the Omega laser facility. Differences between background levels observed with photographic film readout and charge-coupled-device readout have been studied.

15.
Science ; 327(5970): 1231-5, 2010 Mar 05.
Article in English | MEDLINE | ID: mdl-20110464

ABSTRACT

Measurements of x-ray-driven implosions with charged particles have resulted in the quantitative characterization of critical aspects of indirect-drive inertial fusion. Three types of spontaneous electric fields differing in strength by two orders of magnitude, the largest being nearly one-tenth of the Bohr field, were discovered with time-gated proton radiographic imaging and spectrally resolved proton self-emission. The views of the spatial structure and temporal evolution of both the laser drive in a hohlraum and implosion properties provide essential insight into, and modeling validation of, x-ray-driven implosions.

16.
Rev Sci Instrum ; 79(10): 10E901, 2008 Oct.
Article in English | MEDLINE | ID: mdl-19044556

ABSTRACT

We present scaled demonstrations of backlighter sources, emitting bremsstrahlung x rays with photon energies above 75 keV, that we will use to record x-ray Compton radiographic snapshots of cold dense DT fuel in inertial confinement fusion implosions at the National Ignition Facility (NIF). In experiments performed at the Titan laser facility at Lawrence Livermore National Laboratory, we measured the source size and the bremsstrahlung spectrum as a function of laser intensity and pulse length from solid targets irradiated at 2x10(17)-5x10(18) W/cm(2) using 2-40 ps pulses. Using Au planar foils we achieved source sizes down to 5.5 microm and conversion efficiencies of about 1x10(-13) J/J into x-ray photons with energies in the 75-100 keV spectral range. We can now use these results to design NIF backlighter targets and shielding and to predict Compton radiography performance as a function of the NIF implosion yield and associated background.

17.
Rev Sci Instrum ; 79(10): 10E921, 2008 Oct.
Article in English | MEDLINE | ID: mdl-19044576

ABSTRACT

Detailed analysis of x-ray narrow-band images from argon-doped deuterium-filled inertial confinement fusion implosion experiments yields information about the temperature spatial structure in the core at the collapse of the implosion. We discuss the analysis of direct-drive implosion experiments at OMEGA, in which multiple narrow-band images were recorded with a multimonochromatic x-ray imaging instrument. The temperature spatial structure is investigated by using the sensitivity of the Ly beta/He beta line emissivity ratio to the temperature. Three analysis methods that consider the argon He beta and Ly beta image data are discussed and the results compared. The methods are based on a ratio of image intensities, ratio of Abel-inverted emissivities, and a search and reconstruction technique driven by a Pareto genetic algorithm.

18.
Rev Sci Instrum ; 79(10): 10E931, 2008 Oct.
Article in English | MEDLINE | ID: mdl-19044586

ABSTRACT

At the National Ignition Facility (NIF), 192 laser beams will compress a target containing a mixture of deuterium and tritium that will release fusion neutrons, photons, and other radiation. Diagnostics are being designed to measure this emitted radiation to infer crucial parameters of an ignition shot. Chemical vapor deposited (CVD) diamond is one of the ignition diagnostics that will be used as a neutron time-of-flight detector for measuring primary (14.1 MeV) neutron yield, ion temperature, and plasma areal density. This last quantity is the subject of this study and is inferred from the number of downscattered neutrons arriving late in time, divided by the number of primary neutrons. We determine in this study the accuracy with which this detector can measure areal density when the limiting factor is detector and electronics saturation. We used laser-produced x-rays to reproduce NIF signals in terms of charge carrier density, time between pulses, and amplitude contrast and found that the effect of the large pulse on the small pulse is at most 8.4%, which is less than the NIF accuracy requirement of +/-10%.

19.
Phys Rev E Stat Nonlin Soft Matter Phys ; 76(5 Pt 2): 056403, 2007 Nov.
Article in English | MEDLINE | ID: mdl-18233772

ABSTRACT

In the field of inertial confinement fusion (ICF), work has been consistently progressing in the past decade toward a more fundamental understanding of the plasma conditions in ICF implosion cores. The research presented here represents a substantial evolution in the ability to diagnose plasma temperatures and densities, along with characteristics of mixing between fuel and shell materials. Mixing is a vital property to study and quantify, since it can significantly affect implosion quality. We employ a number of new spectroscopic techniques that allow us to probe these important quantities. The first technique developed is an emissivity analysis, which uses the emissivity ratio of the optically thin Lybeta and Hebeta lines to spectroscopically extract temperature profiles, followed by the solution of emissivity equations to infer density profiles. The second technique, an intensity analysis, models the radiation transport through the implosion core. The nature of the intensity analysis allows us to use an optically thick line, the Lyalpha, to extract information on mixing near the core edge. With this work, it is now possible to extract directly from experimental data not only detailed temperature and density maps of the core, but also spatial mixing profiles.

20.
Acta Radiol ; 47(1): 15-23, 2006 Feb.
Article in English | MEDLINE | ID: mdl-16498928

ABSTRACT

PURPOSE: To evaluate the ability of contrast-enhanced magnetic resonance imaging (MRI) with Gd-EOB-DTPA in comparison with non-enhanced imaging and spiral computed tomography (CT) to provide additional information for classification and characterization of hepatocellular carcinoma. MATERIAL AND METHODS: Forty patients with histopathology-proven hepatocellular carcinoma were selected for this subgroup analysis from a phase-III multicenter study in 235 patients with known or suspected liver lesions. The primary analysis was comparison of the proportion of hepatocellular carcinoma correctly classified and characterized by combined pre-/post-contrast MRI compared with pre-contrast MRI alone or with spiral CT. All images were evaluated on site, and in a blinded reading by three independent readers off site. RESULTS: In the on-site evaluation, the lesions were correctly classified as a malignant tumor with combined MRI in 90.3%, with pre-contrast imaging alone in 82.9% and with spiral CT in 87.8% (n.s.). The proportion of correct characterization (lesion type diagnosis) with combined MRI was 85.4%, 75.6% for pre-contrast imaging, and 77.5% for spiral CT (n.s.), respectively. In the blinded reading, one reader showed a significant increase in the proportion of correctly characterized lesions by 27% (P<0.05). The other two readers showed a reduction in the proportion of correct characterization by 12% and 15%, respectively (n.s.). CONCLUSION: With regard to lesion classification, no difference was found between combined pre-/post-contrast MRI and spiral CT. A non-significant trend in favor of Gd-EOB-DTPA-enhanced MRI with regard to characterization of hepatocellular carcinoma was found, although the CT scans were not optimized as the MRI scans.


Subject(s)
Carcinoma, Hepatocellular/diagnosis , Contrast Media/administration & dosage , Gadolinium DTPA , Liver Neoplasms/diagnosis , Magnetic Resonance Imaging/methods , Adult , Aged , Aged, 80 and over , Carcinoma, Hepatocellular/classification , Europe , Female , Humans , Image Enhancement/methods , Liver/diagnostic imaging , Liver/pathology , Liver Neoplasms/classification , Male , Middle Aged , Observer Variation , Prospective Studies , Reproducibility of Results , Tomography, Spiral Computed/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...