Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Trials ; 12: 223, 2011 Oct 11.
Article in English | MEDLINE | ID: mdl-21988742

ABSTRACT

BACKGROUND: Systemic inflammation in response to a femur fracture and the additional fixation is associated with inflammatory complications, such as acute respiratory distress syndrome and multiple organ dysfunction syndrome. The injury itself, but also the additional procedure of femoral fixation induces a release of pro-inflammatory cytokines such as interleukin-6. This results in an aggravation of the initial systemic inflammatory response, and can cause an increased risk for the development of inflammatory complications. Recent studies have shown that administration of the serum protein C1-esterase inhibitor can significantly reduce the release of circulating pro-inflammatory cytokines in response to acute systemic inflammation. OBJECTIVE: Attenuation of the surgery-induced additional systemic inflammatory response by perioperative treatment with C1-esterase inhibitor of trauma patients with a femur fracture. METHODS: The study is designed as a double-blind randomized placebo-controlled trial. Trauma patients with a femur fracture, Injury Severity Score ≥ 18 and age 18-80 years are included after obtaining informed consent. They are randomized for administration of 200 U/kg C1-esterase inhibitor intravenously or placebo (saline 0.9%) just before the start of the procedure of femoral fixation. The primary endpoint of the study is Δ interleukin-6, measured at t = 0, just before start of the femur fixation surgery and administration of C1-esterase inhibitor, and t = 6, 6 hours after administration of C1-esterase inhibitor and the femur fixation. CONCLUSION: This study intents to identify C1-esterase inhibitor as a safe and potent anti-inflammatory agent, that is capable of suppressing systemic inflammation in trauma patients. This might facilitate early total care procedures by lowering the risk of inflammation in response to the surgical intervention. This could result in increased functional outcomes and reduced health care related costs.


Subject(s)
Clinical Protocols , Complement C1 Inhibitor Protein/therapeutic use , Femoral Fractures/complications , Inflammation/drug therapy , Adolescent , Adult , Aged , Aged, 80 and over , Double-Blind Method , Humans , Middle Aged , Outcome Assessment, Health Care
2.
PLoS One ; 6(6): e21246, 2011.
Article in English | MEDLINE | ID: mdl-21731683

ABSTRACT

Intravenous immunoglobulin G (IVIg) is widely used against a range of clinical symptoms. For its use in immune modulating therapies such as treatment of immune thrombocytopenic purpura high doses of IVIg are required. It has been suggested that only a fraction of IVIg causes this anti immune modulating effect. Recent studies indicated that this fraction is the Fc-sialylated IgG fraction. The aim of our study was to determine the efficacy of IVIg enriched for sialylated IgG (IVIg-SA⁺) in a murine model of passive immune thrombocytopenia (PIT). We enriched IVIg for sialylated IgG by Sambucus nigra agglutinin (SNA) lectin fractionation and determined the degree of sialylation. Analysis of IVIg-SA⁺ using a lectin-based ELISA revealed that we enriched predominantly for Fab-sialylated IgG, whereas we did not find an increase in Fc-sialylated IgG. Mass spectrometric analysis confirmed that Fc sialylation did not change after SNA lectin fractionation. The efficacy of sialylated IgG was measured by administering IVIg or IVIg-SA⁺ 24 hours prior to an injection of a rat anti-mouse platelet mAb. We found an 85% decrease in platelet count after injection of an anti-platelet mAb, which was reduced to a 70% decrease by injecting IVIg (p<0.01). In contrast, IVIg-SA⁺ had no effect on the platelet count. Serum levels of IVIg and IVIg-SA⁺ were similar, ruling out enhanced IgG clearance as a possible explanation. Our results indicate that SNA lectin fractionation is not a suitable method to enrich IVIg for Fc-sialylated IgG. The use of IVIg enriched for Fab-sialylated IgG abolishes the efficacy of IVIg in the murine PIT model.


Subject(s)
Immunoglobulin G/immunology , Immunomodulation/immunology , N-Acetylneuraminic Acid/metabolism , Plant Lectins/metabolism , Purpura, Thrombocytopenic, Idiopathic/immunology , Ribosome Inactivating Proteins/metabolism , Animals , Chemical Fractionation , Chromatography, Affinity , Disease Models, Animal , Enzyme-Linked Immunosorbent Assay , Glycosylation , Humans , Immunoglobulins, Intravenous/administration & dosage , Immunoglobulins, Intravenous/therapeutic use , Mass Spectrometry , Mice , Platelet Count , Purpura, Thrombocytopenic, Idiopathic/drug therapy , Rats
3.
Crit Care Med ; 38(11): 2139-45, 2010 Nov.
Article in English | MEDLINE | ID: mdl-20693886

ABSTRACT

OBJECTIVE: Besides its role in regulation of the complement and contact system, C1-esterase inhibitor has other immunomodulating effects that could prove beneficial in patients with acute inflammation such as during sepsis or after trauma. We examined the immunomodulating properties of C1-esterase inhibitor during human experimental endotoxemia, in which the innate immune system is activated in the absence of activation of the classic complement pathway. DESIGN: Double-blind placebo-controlled study. SETTING: Research intensive care unit of the Radboud University Nijmegen Medical Centre. SUBJECTS: Twenty healthy volunteers. INTERVENTIONS: Intravenous injection of 2 ng/kg Escherichia coli lipopolysaccharide. Thirty minutes thereafter (to prevent binding of lipopolysaccharide), C1-esterase inhibitor concentrate (100 U/kg, n = 10) or placebo (n = 10) was infused. MEASUREMENTS AND MAIN RESULTS: Pro- and anti-inflammatory mediators, markers of endothelial and complement activation, hemodynamics, body temperature, and symptoms were measured. C1-esterase inhibitor reduced the release of proinflammatory cytokines as well as C-reactive protein (peak levels of: interleukin-6 1521 ± 209 vs. 932 ± 174 pg/mL [p = .04], tumor necrosis factor-α 1213 ± 187 vs. 827 ± 167 pg/mL [p = .10], monocyte chemotactic protein-1 6161 ± 1302 vs. 3373 ± 228 pg/mL [p = .03], interleukin-1ß 34 ± 5 vs. 23 ± 2 pg/mL [p < .01], C-reactive protein 39 ± 4 vs. 29 ± 2 mg/L [p = .02]). In contrast, release of the anti-inflammatory cytokine interleukin-10 was increased by C1-esterase inhibitor (peak level 73 ± 11 vs. 121 ± 18 pg/mL, p = .02). The increase in interleukin-1 receptor antagonist tended to be smaller in the C1-esterase inhibitor group, but this effect did not reach statistical significance (p = .07). Markers for endothelial activation were increased after lipopolysaccharide infusion, but no significant differences between groups were observed. The lipopolysaccharide-induced changes in heart rate, blood pressure, body temperature, and symptoms (all p < .001 over time) were not influenced by C1-esterase inhibitor. Complement fragment C4 was not increased after lipopolysaccharide challenge. CONCLUSIONS: This study is the first to demonstrate that C1-esterase inhibitor exerts anti-inflammatory effects in the absence of classic complement activation in humans.


Subject(s)
Complement C1 Inhibitor Protein/therapeutic use , Complement Inactivating Agents/therapeutic use , Endotoxemia/drug therapy , Inflammation/drug therapy , Blood Pressure/drug effects , Body Temperature/drug effects , C-Reactive Protein/analysis , Complement C4/analysis , Double-Blind Method , Endotoxemia/physiopathology , Endotoxins/pharmacology , Heart Rate/drug effects , Humans , Interleukin-1beta/blood , Interleukin-6/blood , Male , Tumor Necrosis Factor-alpha/blood , Young Adult
4.
Transfusion ; 45(10): 1601-9, 2005 Oct.
Article in English | MEDLINE | ID: mdl-16181211

ABSTRACT

BACKGROUND: Intravenous immunoglobulin (IVIG) products formulated as a liquid instead of a powder have become commercially available. Preferably, such liquid products should not alter after storage outside the refrigerator. Therefore, a thorough characterization of immunoglobulin G (IgG) fragmentation at various storage temperatures is required. STUDY DESIGN AND METHODS: Storage experiments with liquid IVIG products from five manufacturers were performed at 4, 25, and 37 degrees C and IgG fragments were analyzed. RESULTS: Storage of liquid IVIG products at 4 degrees C resulted in negligible alterations, whereas an increase of IgG fragments was observed after prolonged storage at elevated temperatures. Sodium dodecyl sulfate-polyacrylamide gel electrophoresis and Western blot analysis of five liquid IVIG products revealed three IgG fragments (12, 26, and 54 kDa) in all products. Fragments of similar molecular mass were produced upon incubations of IgG with blood-derived proteases. N-terminal amino acid sequencing revealed the cleavage site of these fragments, suggesting human neutrophil elastase to cause the 12-kDa fragment. The presence of elastase in liquid IVIG was confirmed by enzyme-linked immunosorbent assay. The origin of the 26- and 54-kDa fragments, both with an aspartic acid residue at the cleavage site, could not be determined unambiguously. CONCLUSION: IgG fragmentation in liquid IVIG is negligible when stored in the refrigerator. Only after prolonged storage at elevated temperature does proteolytic degradation of IgG become apparent.


Subject(s)
Immunoglobulin Fragments/analysis , Immunoglobulin G/analysis , Immunoglobulins, Intravenous/chemistry , Blotting, Western , Chromatography, Liquid , Cold Temperature , Drug Storage , Electrophoresis, Polyacrylamide Gel , Enzyme-Linked Immunosorbent Assay , Humans , Immunoglobulin G/metabolism , Leukocyte Elastase/analysis , Leukocyte Elastase/metabolism , Molecular Weight , Peptide Hydrolases/metabolism , Refrigeration , Sequence Analysis, Protein , Temperature
SELECTION OF CITATIONS
SEARCH DETAIL
...