Clin Imaging ; 38(2): 85-90, 2014.
Article in English | MEDLINE | ID: mdl-24359643

ABSTRACT

The purpose of this retrospective clinical study was to identify and evaluate the presence and frequency of T2 FLAIR artifacts on brain MRI studies performed at 3 T. We reviewed axial T2 FLAIR images in 200 consecutive unremarkable brain MRI studies performed at 3 T. All studies were reviewed for the presence of artifacts caused by pulsatile CSF flow, magnetic susceptibility and no nulling of the CSF signal. T2 FLAIR images introduce several artifacts that may degrade image quality and mimic pathology. Knowledge of these artifacts and increased severity and frequency at 3 T is of particular importance in avoiding a misdiagnosis.


Subject(s)
Image Processing, Computer-Assisted/methods , Magnetic Resonance Imaging , Adult , Aged , Aged, 80 and over , Artifacts , Brain/pathology , Cerebrospinal Fluid , Female , Humans , Male , Middle Aged , Pulsatile Flow , Retrospective Studies , Signal-To-Noise Ratio , Young Adult