Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
BMC Ophthalmol ; 23(1): 392, 2023 Sep 26.
Article in English | MEDLINE | ID: mdl-37752479

ABSTRACT

BACKGROUND: To evaluate the feasibility of creating flanges using an optic piercing technique with a 6 - 0 polypropylene monofilament for scleral fixation of dislocated one-piece diffractive multifocal intraocular lenses (IOLs). STUDY DESIGN: Experimental study and case series. SUBJECTS: Optical bench test and eyes with IOL dislocation. METHODS: Two separate 6 - 0 polypropylenes were penetrated twice at the opposite peripheral optic of the TECNIS Synergy IOL (Johnson & Johnson Vision). The root mean square of the modulation transfer function (MTFRMS), at between + 1.00 and - 4.00 D of defocus, was measured in the TECNIS Synergy IOL both with and without optic piercing in the optical bench study. This case series included three eyes from two patients who underwent scleral-fixation of multifocal IOLs using the four-flanged polypropylene optic piercing technique. The postoperative corrected distance visual acuity (CDVA) at 4 m, the uncorrected near visual acuity (UNVA) at 40 cm, and IOL centration were evaluated. RESULTS: The optical bench test showed no differences in MTFRMS values measured in the TECNIS Synergy IOL, either with or without optic piercing at all defocuses. In all three case series, the postoperative CDVA at 4 m was 20/20 and UNVA at 40 cm was J1. Postoperative anterior segment photographs showed good centration of IOLs in all cases. CONCLUSION: The four-flanged polypropylene optic piercing technique for multifocal IOL scleral fixation can provide excellent clinical outcomes and IOL stability after surgery without diminishing the performance of the multifocal IOLs.


Subject(s)
Lenses, Intraocular , Multifocal Intraocular Lenses , Humans , Polypropylenes , Lens Implantation, Intraocular/methods , Visual Acuity
2.
J Cataract Refract Surg ; 49(10): 1036-1042, 2023 10 01.
Article in English | MEDLINE | ID: mdl-37440456

ABSTRACT

PURPOSE: To compare patient experiences and cooperation and the clinical outcomes illuminated chopper vs conventional chopper during cataract surgery. SETTING: 4 tertiary institutions in Korea. DESIGN: Prospective, randomized, paired-eye, controlled pilot study. METHODS: 152 eyes of 76 patients who underwent bilateral cataract surgeries were enrolled in this study. The surgical method was randomly assigned to each patient's eye (1 eye using the illuminated chopper with a light source and the other using the conventional chopper under the microscope light). Patient suffering scores (the degree of strong light perception, glare, inability to fixate, anxiety, discomfort, and fear) from 0 to 10 (10 being the most severe level); cooperation score from 0 to 3 (3 being the best cooperation); operating time; and corneal endothelial cell density (ECD) preoperatively and postoperatively were compared between the 2 groups. RESULTS: The mean patient suffering score of all 6 parameters in the iChopper group was significantly smaller than those in the control group (all P < .05). The mean patient cooperation score of the iChopper group (2.3 ± 0.8) was significantly greater than that of the control (1.6 ± 0.9; P < .001). There was no significant difference in the mean operating time and corneal ECD at each visit between the groups, albeit the mean corneal ECD was significantly decreased from baseline to 1 month after cataract surgery in both groups. CONCLUSIONS: Phacoemulsification using the illuminated chopper provides less glare and anxiety and better cooperation during cataract surgery without increasing the operating time and damaging corneal endothelium compared with the conventional chopper.


Subject(s)
Cataract , Phacoemulsification , Humans , Lens Implantation, Intraocular , Prospective Studies , Visual Acuity , Phacoemulsification/methods , Endothelium, Corneal , Patient Outcome Assessment , Cell Count
SELECTION OF CITATIONS
SEARCH DETAIL
...