Neuroimage ; 282: 120411, 2023 11 15.
Article in English | MEDLINE | ID: mdl-37844771

ABSTRACT

Transcranial focused ultrasound (tFUS), in which acoustic energy is focused on a small region in the brain through the skull, is a non-invasive therapeutic method with high spatial resolution and depth penetration. Image-guided navigation has been widely utilized to visualize the location of acoustic focus in the cranial cavity. However, this system is often inaccurate because of the significant aberrations caused by the skull. Therefore, acoustic simulations using a numerical solver have been widely adopted to compensate for this inaccuracy. Although the simulation can predict the intracranial acoustic pressure field, real-time application during tFUS treatment is almost impossible due to the high computational cost. In this study, we propose a neural network-based real-time acoustic simulation framework and test its feasibility by implementing a simulation-guided navigation (SGN) system. Real-time acoustic simulation is performed using a 3D conditional generative adversarial network (3D-cGAN) model featuring residual blocks and multiple loss functions. This network was trained by the conventional numerical acoustic simulation program (i.e., k-Wave). The SGN system is then implemented by integrating real-time acoustic simulation with a conventional image-guided navigation system. The proposed system can provide simulation results with a frame rate of 5 Hz (i.e., about 0.2 s), including all processing times. In numerical validation (3D-cGAN vs. k-Wave), the average peak intracranial pressure error was 6.8 ± 5.5%, and the average acoustic focus position error was 5.3 ± 7.7 mm. In experimental validation using a skull phantom (3D-cGAN vs. actual measurement), the average peak intracranial pressure error was 4.5%, and the average acoustic focus position error was 6.6 mm. These results demonstrate that the SGN system can predict the intracranial acoustic field according to transducer placement in real-time.


Subject(s)
Brain , Skull , Humans , Feasibility Studies , Brain/diagnostic imaging , Skull/diagnostic imaging , Computer Simulation , Acoustics
2.
IEEE J Biomed Health Inform ; 26(1): 161-171, 2022 01.
Article in English | MEDLINE | ID: mdl-34388098

ABSTRACT

Transcranial focused ultrasound (tFUS) is a promising non-invasive technique for treating neurological and psychiatric disorders. One of the challenges for tFUS is the disruption of wave propagation through the skull. Consequently, despite the risks associated with exposure to ionizing radiation, computed tomography (CT) is required to estimate the acoustic transmission through the skull. This study aims to generate synthetic CT (sCT) from T1-weighted magnetic resonance imaging (MRI) and investigate its applicability to tFUS acoustic simulation. We trained a 3D conditional generative adversarial network (3D-cGAN) with 15 subjects. We then assessed image quality with 15 test subjects: mean absolute error (MAE) = 85.72±9.50 HU (head) and 280.25±24.02 HU (skull), dice coefficient similarity (DSC) = 0.88±0.02 (skull). In terms of skull density ratio (SDR) and skull thickness (ST), no significant difference was found between sCT and real CT (rCT). When the acoustic simulation results of rCT and sCT were compared, the intracranial peak acoustic pressure ratio was found to be less than 4%, and the distance between focal points less than 1 mm.


Subject(s)
Magnetic Resonance Imaging , Tomography, X-Ray Computed , Acoustics , Computer Simulation , Humans , Magnetic Resonance Imaging/methods , Skull/diagnostic imaging , Tomography, X-Ray Computed/methods