ABSTRACT

Involvement of parametrial disease in locally advanced cervical patients poses a challenge for women undergoing brachytherapy. Current use of the Fletcher suit applicator may not adequately cover the high risk clinical target volume (HR CTV), especially in the parametrial region due to the physical qualities of brachytherapy from the inverse square law and the need to respect organs at risk (OAR) constraints, and leads to lower local control rates. Combined intracavitary and interstitial brachytherapy with the use of 1 or 2 interstitial needles allows adequate coverage of the HR CTV and the clinical evidence have demonstrated a correlation with better clinical results. This procedure is often resource intensive, requiring inpatient stay and magnetic resonance imaging (MRI) planning. In departments where such resources are limited, there is a poor uptake of interstitial brachytherapy. This article discusses the technique of combined intracavitary and interstitial brachytherapy in an outpatient setting, and explores the issues and barriers for implementation and suggestions to overcome such barriers.

2.
J Contemp Brachytherapy ; 6(2): 173-7, 2014 Jun.
Article in English | MEDLINE | ID: mdl-25097558

ABSTRACT

PURPOSE: Currently, there are two described methods of catheter insertion for women undergoing multicatheter interstitial accelerated partial breast irradiation (APBI). These are a volume based template approach (template) and a non-template ultrasound guidance freehand approach (non-template). We aim to compare dosimetric endpoints between the template and non-template approach. MATERIAL AND METHODS: Twenty patients, who received adjuvant multicatheter interstitial APBI between August 2008 to March 2010 formed the study cohort. Dosimetric planning was based on the RTOG 04-13 protocol. For standardization, the planning target volume evaluation (PTV-Eval) and organs at risk were contoured with the assistance of the attending surgeon. Dosimetric endpoints include D90 of the PTV-Eval, Dose Homogeneity Index (DHI), V200, maximum skin dose (MSD), and maximum chest wall dose (MCD). A median of 18 catheters was used per patient. The dose prescribed was 34 Gy in 10 fractions BID over 5 days. RESULTS: The average breast volume was 846 cm(3) (526-1384) for the entire cohort and there was no difference between the two groups (p = 0.6). Insertion time was significantly longer for the non-template approach (mean 150 minutes) compared to the template approach (mean: 90 minutes) (p = 0.02). The planning time was also significantly longer for the non-template approach (mean: 240 minutes) compared to the template approach (mean: 150 minutes) (p < 0.01). The template approach yielded a higher D90 (mean: 95%) compared to the non-template approach (mean: 92%) (p < 0.01). There were no differences in DHI (p = 0.14), V200 (p = 0.21), MSD (p = 0.7), and MCD (p = 0.8). CONCLUSIONS: Compared to the non-template approach, the template approach offered significant shorter insertion and planning times with significantly improved dosimetric PTV-Eval coverage without significantly compromising organs at risk dosimetrically.

SELECTION OF CITATIONS
SEARCH DETAIL