Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
BMC Anesthesiol ; 21(1): 205, 2021 08 16.
Article in English | MEDLINE | ID: mdl-34399681

ABSTRACT

BACKGROUND: Anesthesia leads to impairments in central and peripheral thermoregulatory responses. Inadvertent perioperative hypothermia is hence a common perioperative complication, and is associated with coagulopathy, increased surgical site infection, delayed drug metabolism, prolonged recovery, and shivering. However, surveys across the world have shown poor compliance to perioperative temperature management guidelines. Therefore, we evaluated the prevalent practices and attitudes to perioperative temperature management in the Asia-Pacific region, and determined the individual and institutional factors that lead to noncompliance. METHODS: A 40-question anonymous online questionnaire was distributed to anesthesiologists and anesthesia trainees in six countries in the Asia-Pacific (Singapore, Malaysia, Philippines, Thailand, India and South Korea). Participants were polled about their current practices in patient warming and temperature measurement across the preoperative, intraoperative and postoperative periods. Questions were also asked regarding various individual and environmental barriers to compliance. RESULTS: In total, 1154 valid survey responses were obtained and analyzed. 279 (24.2%) of respondents prewarm, 508 (44.0%) perform intraoperative active warming, and 486 (42.1%) perform postoperative active warming in the majority of patients. Additionally, 531 (46.0%) measure temperature preoperatively, 767 (67.5%) measure temperature intraoperatively during general anesthesia, and 953 (82.6%) measure temperature postoperatively in the majority of patients. The availability of active warming devices in the operating room (p < 0.001, OR 10.040), absence of financial restriction (p < 0.001, OR 2.817), presence of hospital training courses (p = 0.011, OR 1.428), and presence of a hospital SOP (p < 0.001, OR 1.926) were significantly associated with compliance to intraoperative active warming. CONCLUSIONS: Compliance to international perioperative temperature management guidelines in Asia-Pacific remains poor, especially in small hospitals. Barriers to compliance were limited temperature management equipment, lack of locally-relevant standard operating procedures and training. This may inform international guideline committees on the needs of developing countries, or spur local anesthesiology societies to publish their own national guidelines.


Subject(s)
Body Temperature , Hypothermia/prevention & control , Monitoring, Intraoperative , Perioperative Care , Practice Patterns, Physicians'/statistics & numerical data , Anesthesiologists , Asia , Cross-Sectional Studies , Humans , Intraoperative Complications/prevention & control , Surveys and Questionnaires
2.
Korean J Pain ; 34(1): 66-71, 2021 Jan 01.
Article in English | MEDLINE | ID: mdl-33380569

ABSTRACT

BACKGROUND: Trigeminal neuralgia is a debilitating craniofacial pain syndrome that is characterized by paroxysms of intense, short-lived electric shock-like pains in the trigeminal nerve distribution. Recently, the presence of triggers has become one of the key diagnostic criteria in the 3rd edition of the International Classification of Headache Disorders. Light touch is the most common trigger, however other non-mechanical triggers, such as cold weather and certain foods, have been thought to provoke trigeminal neuralgia anecdotally. We aimed to characterize the prevalence and characteristics of these atypical triggers. METHODS: We conducted a retrospective, cross-sectional study of atypical triggers in trigeminal neuralgia patients seen in a tertiary pain clinic in Singapore. Patients were recruited via clinic records, and study data were identified from physician documentation. RESULTS: A total of 60 patients met the inclusion criteria. Weather triggers were observed in 12 patients (20%), of which five patients (8%) reported strong winds, 4 patients (7%) reported cold temperatures, and 3 patients (5%) reported cold winds as triggers. Fifteen patients (25%) had a specific food trigger, of which 10 patients (17%) reported hard or tough food, 5 patients (8%) reported hot/cold food, 4 patients (7%) reported spicy food, and 2 patients (3%) reported sweet food as triggers. CONCLUSIONS: Although trigeminal neuralgia is most commonly triggered by mechanical stimuli, atypical triggers such as cold temperatures and certain foods are seen in a significant proportion of patients. These atypical triggers may share a common pathway of sensory afferent Aδ fiber activation.

3.
PLoS One ; 15(12): e0243217, 2020.
Article in English | MEDLINE | ID: mdl-33259536

ABSTRACT

INTRODUCTION: Teaching endotracheal intubation is uniquely challenging due to its technical, high-stakes, and highly time-sensitive nature. The GoPro is a small, lightweight, high-resolution action camera with a wide-angle field of view that can encompass both the airway as well as the procedurist's hands and positioning technique when worn with a head mount. We aimed to evaluate its effectiveness in improving intubation teaching for novice learners in a simulated setting, via a two-arm, parallel group, randomized controlled superiority trial with 1:1 allocation ratio. METHODS: We recruited Year 4 medical students at the start of their compulsory 2-week Anesthesia posting. Participants underwent a standardized intubation curriculum and a formative assessment, then randomized to receive GoPro or non-GoPro led feedback. After a span of three months, participants were re-assessed in a summative assessment by blinded accessors. Participants were also surveyed on their learning experience for a qualitative thematic perspective. The primary outcomes were successful intubation and successful first-pass intubation. RESULTS: Seventy-one participants were recruited with no dropouts, and all were included in the analysis. 36 participants received GoPro led feedback, and 35 participants received non-GoPro led feedback. All participants successfully intubated the manikin. No statistically significant differences were found between the GoPro group and the non-GoPro group at summative assessment (85.3% vs 90.0%, p = 0.572). Almost all participants surveyed found the GoPro effective for their learning (98.5%). Common themes in the qualitative analysis were: the ability for an improved assessment, greater identification of small details that would otherwise be missed, and usefulness of the unique point-of-view footage in improving understanding. CONCLUSIONS: The GoPro is a promising tool for simulation-based intubation teaching. There are considerations in its implementation to maximize the learning experience and yield from GoPro led feedback and training.


Subject(s)
Anesthesiology/education , Education, Medical, Undergraduate/methods , Intubation, Intratracheal/methods , Photography/instrumentation , Clinical Competence , Computer Simulation , Computer-Assisted Instruction/methods , Curriculum , Feedback , Female , Humans , Male , Problem-Based Learning/methods , Singapore , Students, Medical , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...