Transfus Med ; 16(4): 276-84, 2006 Aug.
Article in English | MEDLINE | ID: mdl-16879156

ABSTRACT

To compare the performance of seven currently available test systems in the detection of erythrocyte alloantibodies (ab), we tested in parallel 446 sera samples containing red cell ab [368 sera samples with ab that are assumed to be clinically significant (cs-ab) and 78 sera samples with ab that are assumed to be of minor clinical significance (ms-ab)] using the tube spin low-ionic-strength solution (addition method) indirect antiglobulin test (tube LISS-IAT), three microtube column agglutination techniques (DiaMed-ID, Ortho BioVue and Bio-Rad Scangel), one affinity adherence test system (CLB/Mast CellBind Screen) and two solid-phase tests [Biotest Solidscreen II and Immucor Capture-R Ready-Screen (4)]. To address the specificity of the three test systems under routine conditions, results of 4566 patient samples obtained using the tube LISS-IAT, results of 5205 patient samples obtained using the Scangel and results of 3560 samples obtained using the Capture-R were evaluated. The DiaMed-ID detected 344 cs-ab and 43 ms-ab, BioVue 333 cs-ab and 48 ms-ab, Scangel 348 cs-ab and 62 ms-ab, CellBind Screen 346 cs-ab and 47 ms-ab, Solidscreen 330 cs-ab and 38 ms-ab, Capture-R 358 cs-ab and 45 ms-ab and LISS-IAT 159 cs-ab and 12 ms-ab. In routine practice, erythrocyte cs-ab could be identified in 61 (67.8%) of 90 reactive sera (specificity: 98.6%) in the tube LISS-IAT, in 169 (58.7%) of 288 (94.4%) in Bio-Rad Scangel and in 101 (51.0%) of 198 reactive sera (94.3%) in Capture-R. We conclude that the sensitivity of the microcolumn, affinity adherence and solid-phase test systems in the detection of cs-ab was similar and was markedly superior to that of the conventional tube LISS-IAT. All high-sensitive test systems produced higher rates of false positives and ms-ab compared to the tube test. An individual cost-benefit analysis, considering the recent knowledge about the clinical significance of weak-reactive cs-ab, should be performed in every institution to decide whether and if so which high-sensitive screening system should be applied.


Subject(s)
Erythrocytes/immunology , Hemagglutination Tests/methods , Isoantibodies/analysis , Coombs Test/methods , Coombs Test/standards , Cost-Benefit Analysis , Hemagglutination Tests/instrumentation , Hemagglutination Tests/standards , Humans , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...