Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Atmos Meas Tech ; 14(2): 995-1013, 2021 Feb.
Article in English | MEDLINE | ID: mdl-35529304

ABSTRACT

The distribution and dynamics of atmospheric pollutants are spatiotemporally heterogeneous due to variability in emissions, transport, chemistry, and deposition. To understand these processes at high spatiotemporal resolution and their implications for air quality and personal exposure, we present custom, low-cost air quality monitors that measure concentrations of contaminants relevant to human health and climate, including gases (e.g., O3, NO, NO2, CO, CO2, CH4, and SO2) and size-resolved (0.3-10 µm) particulate matter. The devices transmit sensor data and location via cellular communications and are capable of providing concentration data down to second-level temporal resolution. We produce two models: one designed for stationary (or mobile platform) operation and a wearable, portable model for directly measuring personal exposure in the breathing zone. To address persistent problems with sensor drift and environmental sensitivities (e.g., relative humidity and temperature), we present the first online calibration system designed specifically for low-cost air quality sensors to calibrate zero and span concentrations at hourly to weekly intervals. Monitors are tested and validated in a number of environments across multiple outdoor and indoor sites in New Haven, CT; Baltimore, MD; and New York City. The evaluated pollutants (O3, NO2, NO, CO, CO2, and PM2.5) performed well against reference instrumentation (e.g., r = 0.66-0.98) in urban field evaluations with fast e-folding response times (≤1 min), making them suitable for both large-scale network deployments and smaller-scale targeted experiments at a wide range of temporal resolutions. We also provide a discussion of best practices on monitor design, construction, systematic testing, and deployment.

2.
Environ Sci Technol ; 53(2): 838-849, 2019 01 15.
Article in English | MEDLINE | ID: mdl-30563344

ABSTRACT

Due to the rapid development of low-cost air-quality sensors, a rigorous scientific evaluation has not been conducted for many available sensors. We evaluated three Plantower PMS A003 sensors when exposed to eight particulate matter (PM) sources (i.e., incense, oleic acid, NaCl, talcum powder, cooking emissions, and monodispersed polystyrene latex spheres under controlled laboratory conditions and also residential air and ambient outdoor air in Baltimore, MD). The PM2.5 sensors exhibited a high degree of precision and R2 values greater than 0.86 for all sources, but the accuracy ranged from 13 to >90% compared with reference instruments. The sensors were most accurate for PM with diameters below 1 µm, and they poorly measured PM in the 2.5-5 µm range. The accuracy of the sensors was dependent on relative humidity (RH), with decreases in accuracy at RH > 50%. The sensors were able to produce meaningful data at low and high temperatures and when in motion, as it would be if utilized for outdoor or personal monitoring applications. It was most accurate in environments with polydispersed particle sources and may not be useful in specialized environments or experiments with narrow distributions of PM or aerosols with a large proportion of coarse PM.


Subject(s)
Air Pollutants , Air Pollution, Indoor , Air Pollution , Baltimore , Environmental Monitoring , Particle Size , Particulate Matter
SELECTION OF CITATIONS
SEARCH DETAIL
...