Results 1 - 8 de 8
Filter
1.
Cureus ; 16(4): e58611, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38770482

ABSTRACT

Background and objective Implementing electronic patient-reported outcomes (ePROs) in oncology practice has shown substantial clinical benefits. However, it can be challenging in routine practice, warranting strategies to adapt to different clinical contexts. In light of this, this study aimed to describe the implementation process of the ePRO system and elucidate the provider-level implementation barriers and facilitators to a novel ePRO system at cancer hospitals in Japan. Methods We implemented an ePRO system linked to electronic medical records at three cancer hospitals. Fifteen patients with solid cancers at the outpatient oncology unit were asked to regularly complete the Patient-Reported Outcomes version of the Common Terminology Criteria for Adverse Events (PRO-CTCAE™) questionnaire and European Organization for Research and Treatment Core Quality of Life questionnaire (EORTC QLQ C30) by using the smartphone app between October 2021 and June 2022. Thirteen healthcare professionals were interviewed to identify implementation barriers and facilitators to the ePRO system by using the Consolidated Framework for Implementation Research framework. Results The healthcare professionals identified a lack of clinical resources and a culture and system that emphasizes treatment over care as the main barriers; however, the accumulation of successful cases, the leadership of managers, and the growing needs of patients can serve as facilitators to the implementation. Conclusions Our experience implementing an ePRO system in a few Japanese oncology practices revealed comprehensive barriers and facilitators. Further efforts are warranted to develop more successful implementation strategies.

2.
Palliat Care Soc Pract ; 18: 26323524231219519, 2024.
Article in English | MEDLINE | ID: mdl-38188460

ABSTRACT

Background: Advance care planning (ACP) is beneficial for the quality of death (QOD). However, the effects of ACP on the QOD may vary across cultures. Objectives: This study aimed to explore the relationship between the 15-step ACP program and the QOD among Japanese nursing home residents. Design: A cross-sectional survey. Methods: A cross-sectional survey was conducted among the family members of 39 nursing home residents who died between April 2017 and March 2019 by distributing the survey questionnaire by post. The survey included questions about the QOD of residents, and responses were evaluated using the Good Death Inventory (GDI) scale. Results: Responses were obtained from 30 of the 39 bereaved families (76.9%). Data were analyzed using hierarchical clustering to determine five groups and conduct multiple comparisons. The following three domains of interest were identified: 'Dying in a favorite place', 'Good relationship with the medical staff', and 'Independence'. GDI scores were significantly higher for residents with higher ACP completion rates than for those with lower rates (p < 0.01). Residents who had taken ACP interviews had significantly higher GDI scores (p < 0.01) than those who had not taken interviews. Conclusion: Overall, these findings suggest that systematic ACP might be related to the QOD among Japanese nursing home residents in the above mentioned three domains. Limitations of the present study were small sample size, cross-sectional survey design as opposed to a cohort survey design, and multiple biases, including the emotional instability of bereaved family members, the length of stay of the residents, the degree of dementia of the residents, and their tendency to talk about the place of death and to develop good relationships with the medical staff.

3.
Palliat Care Soc Pract ; 18: 26323524231222497, 2024.
Article in English | MEDLINE | ID: mdl-38188459

ABSTRACT

Background: Culturally appropriate communication training programs for a wide range of professions that can be used during infection epidemics are crucial for advance care planning implementation. Starting in 2018, the Japanese Ministry of Health, Labour and Welfare made a major policy change, and doctors, nurses, and social workers, and care managers were identified in the guidelines as the professions that promote advance care planning. Motivated by the lack of online programs for Japanese care managers, we proposed a new one-day program. Objectives: This study aimed to determine the changes in the positive attitude of care managers toward dying patients compared to that of nurses, which has been used in past literature as an outcome of advance care planning educational interventions, after administering the program in Japan. Design: Before-after comparison study. Methods: Care managers were recruited through our website, ACP-Piece, http://plaza.umin.ac.jp/~acp-piece/piece.html. A questionnaire survey concerning positive attitudes toward dying patients was administered before and after the program on 28 August 2021. Sixty-six subjects participated in the training and 60 participants, including 14 care managers, consented to the study and completed the questionnaire surveys before and after the program. Results: The Frommelt attitude toward care of the dying scores for care managers increased after the program (p-values, confidence intervals, and effect sizes: p < 0.001, -11.90 to -4.388, -1.252). After training, care managers had a significantly higher maximum score occurrence than nurses. Older care managers with advance care planning experience may have had a higher maximum score occurrence compared to younger, inexperienced participants. Conclusion: To our knowledge, this is the first to demonstrate the increased positive attitude scores toward dying patients after online communication training for Japanese care managers. The limitations of this study include the lack of evidence regarding reasons for score changes, long-term score changes, and effectiveness for patients and their families.

4.
Med Phys ; 50(11): 7281-7293, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37528637

ABSTRACT

BACKGROUND: Although flattening filter free (FFF) beams are commonly used in clinical treatment, the accuracy of dose measurements in FFF beams has been questioned. Higher dose per pulse (DPP) such as FFF beams from a linear accelerator may cause problems in dose profile measurements using an ionization chamber due to the change of the charge collection efficiency. Ionization chambers are commonly used for percent depth dose (PDD) measurements. Changes of DPP due to chamber movement during PDD measurement can vary the ion collection efficiency of ionization chambers. In the case of FF beams, the DPP fluctuation is negligible, but in the case of the FFF beams, the DPP is 2.5 ∼ 4 times larger than that of the FF beam, and the change in ion collection efficiency is larger than that of the FF beam. PDD profile normalized by maximum dose depth, 10 cm depth for example, may therefore be affected by the ion collection efficiency. PURPOSE: In this study, we investigate the characteristics of the ion collection efficiency change depending on the DPP of each ionization chamber in the FFF beam. We furthermore propose a method to obtain the chamber- independent PDD by applying a DPP-dependent ion recombination correction. METHODS: Prior to investigating the relationship between DPP and charge collection efficiency, Jaffe-plots were generated with different DPP settings to investigate the linearity between the applied voltage and collected charge. The absolute dose measurement using eight ionization chambers under the irradiation settings of 0.148, 0.087, and 0.008 cGy/pulse were performed. Applied voltages for the Jaffe-plots were 100, 125, 150, 200, 250, and 300 V. The ion recombination correction factor Pion was calculated by the two-voltage analysis (TVA) method at the applied voltages of 300 and 100 V. The DPP dependency of the charge collection efficiency for each ionization chamber were evaluated from the DPP- Pion plot. PDD profiles for the 10 MV FFF beam were measured using Farmer type chambers (TN30013, FC65-P, and FC65-G) and mini-type chambers (TN31010, TN31021, CC13, CC04, and FC23-C). The PDD profiles were corrected with ion recombination correction at negative and positive polar applied voltages of 100 and 300 V. RESULTS: From the DPP-Pion relation for each ionization chamber with DPP ranging from 0.008 cGy/pulse to 0.148 cGy/pulse, all Farmer and mini-type chambers satisfied the requirements described in AAPM TG-51 addendum. However, Pion for the CC13 was most affected by DPP among tested chambers. The maximum deviation among PDDs using eight ionization chambers for 10 MV FFF was about 1%, but the deviation was suppressed to about 0.5% by applying ion recombination correction at each depth. CONCLUSIONS: In this study, the deviation of PDD profile among the ionization chambers was reduced by the ion recombination coefficient including the DPP dependency, especially for high DPP beams such as FFF beams. The present method is particularly effective for CC13, where the ion collection efficiency is highly DPP dependent.


Subject(s)
Particle Accelerators , Photons , Etoposide , Radiometry/methods
5.
Med Phys ; 47(11): 5852-5871, 2020 Nov.
Article in English | MEDLINE | ID: mdl-32969046

ABSTRACT

PURPOSE: The beam model in radiation treatment planning systems (RTPSs) plays a crucial role in determining the accuracy of calculated dose distributions. The purpose of this study was to ascertain differences in beam models and their dosimetric influences when a golden beam dataset (GBD) and multi-institution measured beam datasets (MBDs) are used for beam modeling in RTPSs. METHODS: The MBDs collected from 15 institutions, and the MBDs' beam models, were compared with a GBD, and the GBD's beam model, for Varian TrueBeam linear accelerator. The calculated dose distributions of the MBDs' beam models were compared with those of the GBD's beam model for simple geometries in a water phantom. Calculated dose distributions were similarly evaluated in volumetric modulated arc therapy (VMAT) plans for TG-119 C-shape and TG-244 head and neck, at several dose constraints of the planning target volumes (PTVs), and organs at risk. RESULTS: The agreements of the MBDs with the GBD were almost all within ±1%. The calculated dose distributions for simple geometries in a water phantom also closely corresponded between the beam models of GBD and MBDs. Nevertheless, there were considerable differences between the beam models. The maximum differences between the mean energy of the energy spectra of GBD and MBDs were -0.12 MeV (-10.5%) in AcurosXB (AXB, Eclipse) and 0.11 MeV (7.7%) in collapsed cone convolution (CCC, RayStation). The differences in the VMAT calculated dose distributions varied for each dose region, plan, X-ray energy, and dose calculation algorithm. The ranges of the differences in the dose constraints were -5.6% to 3.0% for AXB and -24.1% to 2.8% for CCC. In several VMAT plans, the calculated dose distributions of GBD's beam model tended to be lower in high-dose regions and higher in low-dose regions than those of the MBDs' beam models. CONCLUSIONS: We found that small differences in beam data have large impacts on the beam models, and on calculated dose distributions in clinical VMAT plan, even if beam data correspond within ±1%. GBD's beam model was not a representative beam model. The beam models of GBD and MBDs and their calculated dose distributions under clinical conditions were significantly different. These differences are most likely due to the extensive variation in the beam models, reflecting the characteristics of beam data. The energy spectrum and radial energy in the beam model varied in a wide range, even if the differences in the beam data were <±1%. To minimize the uncertainty of the calculated dose distributions in clinical plans, it was best to use the institutional MBD for beam modeling, or the beam model that ensures the accuracy of calculated dose distributions.


Subject(s)
Radiotherapy Planning, Computer-Assisted , Radiotherapy, Intensity-Modulated , Algorithms , Organs at Risk , Radiometry , Radiotherapy Dosage
6.
Article in Japanese | MEDLINE | ID: mdl-28529252

ABSTRACT

In dynamic multi-leaf collimator (MLC) intensity-modulated radiotherapy (IMRT), the accuracy of delivered dose is influenced by the positional accuracy of the moving MLC. In order to assess the accuracy of the delivered dose during dynamic MLC IMRT, the delivered dose error in dynamic MLC IMRT using the MLC speed control with dose rate change was investigated. Sweeping gap sequence irradiation was performed with constant MLC leaf speed at 0.6 to 5 cm/s or changed MLC speed (4 steps). The positional accuracy of the moving MLC was evaluated from the trajectory log file. Absorbed dose measurements with sweeping field (Field size: 10 cm×10 cm, MLC leaf speed: 0.6 to 2.7 cm/s, MLC leaf gap width: 0.2 to 2.0 cm) were performed. The delivered dose error at each gap width was evaluated according to MLC leaf speed change. MLC positional errors and changes in delivered dose according to MLC leaf speed were within 0.07 mm and 0.6%, respectively, for all measurements. Beam hold-off did not occur under any conditions. We confirmed that TrueBeam can regulate MLC leaf speed below the maximum limit (2.5 cm/s) by changing the dose rate in real-time during irradiation in dynamic MLC IMRT. MLC gap error during irradiation was estimated within 0.2 mm at the maximum dose rate from the results of absolute dose measurements using dynamic MLC irradiation. In conclusion, TrueBeam can use the maximum dose rate for the treatment planning of dynamic MLC IMRT, which has an advantage of shorter treatment time.


Subject(s)
Radiotherapy Dosage , Radiotherapy, Intensity-Modulated/methods , Radiotherapy Planning, Computer-Assisted , Technology, Radiologic