Sensors (Basel) ; 22(19)2022 Oct 04.
Article in English | MEDLINE | ID: mdl-36236619

ABSTRACT

This paper presents an investigation of the responsivity of a time-delay integration (TDI) charge-coupled device that employs anti-blooming clocking and uses a varying number of TDI stages. The influence of charge blooming caused by unused TDI stages in a TDI deployed selection scheme is shown experimentally, and an anti-blooming clocking mechanism is analyzed. The impact of blooming on sensor characteristics, such as the responsivity, the conversion gain, and the signal-to-noise ratio, is investigated. A comparison of the measurements with and without this anti-blooming clocking mechanism is presented and discussed in detail.


Subject(s)
Signal-To-Noise Ratio
2.
Biomed Eng Online ; 20(1): 102, 2021 Oct 12.
Article in English | MEDLINE | ID: mdl-34641889

ABSTRACT

BACKGROUND: Retinal degenerative diseases, e.g., retinitis pigmentosa, cause a severe decline of the visual function up to blindness. Treatment still remains difficult; however, implantation of retinal prostheses can help restoring vision. In this study, the biocompatibility and surgical feasibility of a newly developed epiretinal stimulator (OPTO-EPIRET) was investigated. The previously developed implant was extended by an integrated circuit-based optical capturing, which will enable the immediate conversion of the visual field into stimulation patterns to stimulate retinal ganglion cells. RESULTS: The biocompatibility of the OPTO-EPIRET was investigated in vitro using the two different cell lines L-929 and R28. Direct and indirect contact were analyzed in terms of cell proliferation, cell viability, and gene expression. The surgical feasibility was initially tested by implanting the OPTO-EPIRET in cadaveric rabbit eyes. Afterwards, inactive devices were implanted in six rabbits for feasibility and biocompatibility testings in vivo. In follow-up controls (1-12 weeks post-surgery), the eyes were examined using fundoscopy and optical coherence tomography. After finalization, histological examination was performed to analyze the retinal structure. Regarding the in vitro biocompatibility, no significant influence on cell viability was detected (L929: < 1.3% dead cells; R-28: < 0.8% dead cells). The surgery, which comprised phacoemulsification, vitrectomy, and implantation of the OPTO-EPIRET through a 9-10 mm corneal incision, was successfully established. The implant was fixated with a retinal tack. Vitreal hemorrhage or retinal tearing occurred as main adverse effects. Transitional corneal edema caused difficulties in post-surgical imaging. CONCLUSIONS: The OPTO-EPIRET stimulator showed a good biocompatibility profile in vitro. Furthermore, the implantation surgery was shown to be feasible. However, further design optimization steps are necessary to avoid intra- and postoperative complications. Overall, the OPTO-EPIRET will allow for a wide visual field and good visual acuity due to a high density of electrodes in the central retina.


Subject(s)
Retinitis Pigmentosa , Visual Prosthesis , Animals , Electrodes, Implanted , Prosthesis Implantation , Rabbits , Retina , Retinitis Pigmentosa/surgery
3.
Sensors (Basel) ; 19(19)2019 Sep 23.
Article in English | MEDLINE | ID: mdl-31547579

ABSTRACT

This article presents a new configurable wireless sensor system. The system is used to perform amperometric measurements and send the measurement data to a handheld reader using a wireless transponder interface. The two-chip sensor system was implemented in a 0.35 µm CMOS technology. The system consists of an integrated nano-potentiostat that performs the actual measurements and an ISO 18000-3 compliant frontend that enables wireless telemetric data transmission and powering of the entire sensor system. The system was manufactured in combination with a chronoamperometric glucose sensor which allows the measurement of the glucose content in tear fluid and thus a non-invasive determination of the blood sugar level. For a range of sensor currents from 0.1 µA to 10 µA, the potentiostat achieved an accuracy of better than 5 % with a total power dissipation of less than 600 µW. With the realized antenna geometry a wireless communication distance of more than 7 cm has been achieved.


Subject(s)
Biosensing Techniques/methods , Wireless Technology , Telemetry/methods
4.
Sensors (Basel) ; 18(12)2018 Dec 08.
Article in English | MEDLINE | ID: mdl-30544791

ABSTRACT

Light detection and ranging (LiDAR) systems based on silicon single-photon avalanche diodes (SPAD) offer several advantages, like the fabrication of system-on-chips with a co-integrated detector and dedicated electronics, as well as low cost and high durability due to well-established CMOS technology. On the other hand, silicon-based detectors suffer from high background light in outdoor applications, like advanced driver assistance systems or autonomous driving, due to the limited wavelength range in the infrared spectrum. In this paper we present a novel method based on the adaptive adjustment of photon coincidence detection to suppress the background light and simultaneously improve the dynamic range. A major disadvantage of fixed parameter coincidence detection is the increased dynamic range of the resulting event rate, allowing good measurement performance only at a specific target reflectance. To overcome this limitation we have implemented adaptive photon coincidence detection. In this technique the parameters of the photon coincidence detection are adjusted to the actual measured background light intensity, giving a reduction of the event rate dynamic range and allowing the perception of high dynamic scenes. We present a 192 × 2 pixel CMOS SPAD-based LiDAR sensor utilizing this technique and accompanying outdoor measurements showing the capability of it. In this sensor adaptive photon coincidence detection improves the dynamic range of the measureable target reflectance by over 40 dB.