Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Phys Med ; 124: 103420, 2024 Jul 05.
Article in English | MEDLINE | ID: mdl-38970950

ABSTRACT

PURPOSE: The purpose of this study is to investigate the dosimetric characteristics of a collimator for minibeam radiotherapy (MBRT) with film dosimetry and Monte Carlo (MC) simulations. The outcome of MBRT with respect to conventional RT using a glioma preclinical model was also evaluated. METHODS: A multi-slit collimator was designed to be used with commercial small animal irradiator. The collimator was built by aligning 0.6 mm wide and 5 mm thick parallel lead leaves at 0.4 mm intervals. Dosimetry characteristics were evaluated by Gafchromic (CG) films and TOPAS Monte Carlo (MC) code. An in vivo experiment was performed using a glioma preclinical model by injecting two million GL261cells subcutaneously and treating with 25 Gy, single fraction, with MBRT and conventional RT. Survival curves and acute radiation damage were measured to compare both treatments. RESULTS: A satisfactory agreement between experimental results and MC simulations were obtained, the measured FWHM and distance between the peaks were respectively 0.431 and 1.098 mm. In vivo results show that MBRT can provide local tumor control for three weeks after RT treatment and a similar survival fraction of open beam radiotherapy. No severe acute effects were seen for the MBRT group. CONCLUSIONS: We developed a minibeam collimator and presented its dosimetric features. Satisfactory agreement between MC and GC films was found with differences consistent with uncertainties due to fabrication and set-up errors. The survival curves of MBRT and open field RT are similar while atoxicity is dramatically lower with MBRT, preliminarily confirming the expected effect.

2.
Appl Radiat Isot ; 189: 110416, 2022 Nov.
Article in English | MEDLINE | ID: mdl-36030759

ABSTRACT

In breast cancer radiotherapy treatment with Volumetric Modulated Arc Therapy (VMAT), the respiratory motion may lead to underdosing of the target and overdosing of critical organs such as the heart and lungs. This study aims to investigate the effect of using Virtual Bolus with different thicknesses on VMAT plan quality for patients with 20 advanced left-sided breast cancers. The result of the study showed that using Virtual Bolus for VMAT treatment planning is a viable method to avoid any missing target coverage.


Subject(s)
Breast Neoplasms , Radiotherapy, Intensity-Modulated , Unilateral Breast Neoplasms , Breast Neoplasms/radiotherapy , Female , Humans , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/methods , Unilateral Breast Neoplasms/radiotherapy
SELECTION OF CITATIONS
SEARCH DETAIL
...